Bulletin 120E-C IEC Multi-Speed Starters
| Introduction | Standards Compliance and Certifications | Product Selection | Bulletin 100 Line Starter Accessories | Modifications | Bul. 100 Line Starters Approximate Dimensions |
Enclosed Type — AC Operated
2-Speed Separate Winding, Constant or Variable Torque (Constant Horsepower—Consult your local Rockwell Automation sales office or Allen-Bradley distributor)
| Ratings (AC3, AC4) | IP42 (Type 1) General Purpose Sheet Metal Enclosure (Lift-off Cover through 120E-C72) |
IP66 (Type 3/4/12) Watertight, Dusttight Sheet Metal Enclosure (Hinged Cover) |
|||||||
| Max Ie [A] |
kW | Hp | |||||||
| 3Æ | 1Ƭ | 3Æ | Cat. No. | Cat. No. | |||||
| 380V/415V | 115V | 230V | 200V | 230V | 460V | 575V | |||
| 9 | 4 | 1/2 | 1-1/2 | 2 | 2 | 5 | 7-1/2 | 120E-C09Aĵµ | 120E-C09Fĵµ |
| 12 | 5-1/2 | 1/2 | 2 | 3 | 3 | 7-1/2 | 10 | 120E-C12Aĵµ | 120E-C12Fĵµ |
| 16 | 7-1/2 | 1 | 3 | 5 | 5 | 10 | 15 | 120E-C16Aĵµ | 120E-C16Fĵµ |
| 23 | 11 | 2 | 3 | 5 | 7-1/2 | 15 | 15 | 120E-C23Aĵµ | 120E-C23Fĵµ |
| 30 | 15 | 2 | 5 | 7-1/2 | 10 | 20 | 25 | 120E-C30Aĵµ | 120E-C30Fĵµ |
| 37 | 18-1/2 | 3 | 5 | 10 | 10 | 25 | 30 | 120E-C37Aĵµ | 120E-C37Fĵµ |
| 43 | 22 | 3 | 7-1/2 | 10 | 15 | 30 | 30 | 120E-C43Aĵµ | 120E-C43Fĵµ |
| 60 | 30 | 5 | 10 | 15 | 20 | 40 | 50 | 120E-C60Aĵµ | 120E-C60Fĵµ |
| 72 | 37 | 5 | 10 | 20 | 25 | 50 | 60 | 120E-C72Aĵµ | 120E-C72Fĵµ |
| 85 | 45 | 7-1/2 | 15 | 25 | 30 | 60 | 60 | 120E-C85Aĵµ | 120E-C85Fĵµ |
Ä Coil Voltage Code
The Cat. No. as listed is incomplete. Select a Coil Voltage Code from the table below to complete the Cat. No. Example:
Cat. No. 120E-C09Aĵµµ becomes Cat. No. 120E-C09ABµµ.
| AC Voltage [V] | 24 | 48 | 110 | 120 | 208 | 208… 240 |
220 | 240 | 277 | 380… 400 |
400… 415 |
440 | 480 | 500 | 600 | |
| Common ControlT Coil Voltage Code |
50 Hz | — | — | — | — | — | — | A | T | — | N | G | B | — | M | — |
| 60 Hz | — | — | — | — | H | L | — | A | — | — | — | N | B | — | C | |
| Separate Control (without transformer) Coil Voltage Code |
50 Hz | K | Y | D | — | — | — | — | — | — | — | — | — | — | — | — |
| 60 Hz | J | X | — | D | — | — | — | — | T | — | — | — | — | — | — | |
µ Overload Relay Code
The Cat. No. as listed is incomplete. Select two overload relay codes from Bulletin 193 E1 Plus electronic overload relay for 3-phase applications:
Selectable Trip Class 10, 15, 20, 30, selectable manual/auto reset to complete the Cat. No. The first code will denote the high speed overload relay, and the second code will denote the low speed overload relay.
¬ For single-phase (1Æ) applications, consult your local Rockwell Automation sales office or Allen-Bradley distributor.
T When selecting a factory-installed control circuit transformer (see Modifications), use the Common Control Coil Voltage Code to denote the transformer primary voltage. The starter coil and transformer secondary voltage will both be 120V by default. Example: Cat. No. 120E-C09FBµµ-6P will have a transformer with a 480V primary/120V secondary and a 120V starter coil. If a starter coil voltage other than 120V is desired, a second Coil Voltage Code must be added to denote the coil/transformer secondary voltage. Example: Cat. No. 12E-C09FBJµµ-6P will have a transformer with a 480V primary/24V secondary and a 24V starter coil.