Enclosed Starters

Catalogs > Industrial Controls Catalog > Motor Control, IEC > Enclosed Starters > Bulletin 120E-C IEC Multi-Speed Starters

Bulletin 120E-C IEC Multi-Speed Starters

Introduction Standards Compliance and Certifications Product Selection Bulletin 100 Line Starter Accessories Modifications Bul. 100 Line Starters Approximate Dimensions
Product Selection

Enclosed Type — AC Operated

2-Speed Separate Winding, Constant or Variable Torque (Constant Horsepower—Consult your local Rockwell Automation sales office or Allen-Bradley distributor)

Ratings (AC3, AC4) IP42 (Type 1)
General Purpose
Sheet Metal Enclosure
(Lift-off Cover through 120E-C72)
IP66 (Type 3/4/12)
Watertight, Dusttight
Sheet Metal Enclosure
(Hinged Cover)
Max Ie
[A]
kW Hp
3Æ 1Ƭ  3Æ Cat. No. Cat. No.
380V/415V 115V 230V 200V 230V 460V 575V
9 4 1/2 1-1/2 2 2 5 7-1/2 120E-C09Aĵµ 120E-C09Fĵµ
12 5-1/2 1/2 2 3 3 7-1/2 10 120E-C12Aĵµ 120E-C12Fĵµ
16 7-1/2 1 3 5 5 10 15 120E-C16Aĵµ 120E-C16Fĵµ
23 11 2 3 5 7-1/2 15 15 120E-C23Aĵµ 120E-C23Fĵµ
30 15 2 5 7-1/2 10 20 25 120E-C30Aĵµ 120E-C30Fĵµ
37 18-1/2 3 5 10 10 25 30 120E-C37Aĵµ 120E-C37Fĵµ
43 22 3 7-1/2 10 15 30 30 120E-C43Aĵµ 120E-C43Fĵµ
60 30 5 10 15 20 40 50 120E-C60Aĵµ 120E-C60Fĵµ
72 37 5 10 20 25 50 60 120E-C72Aĵµ 120E-C72Fĵµ
85 45 7-1/2 15 25 30 60 60 120E-C85Aĵµ 120E-C85Fĵµ
  

Ä Coil Voltage Code

The Cat. No. as listed is incomplete. Select a Coil Voltage Code from the table below to complete the Cat. No. Example:
Cat. No. 120E-C09Aĵµµ becomes Cat. No. 120E-C09ABµµ.


AC Voltage [V] 24 48 110 120 208 208…
240
220 240 277 380…
400
400…
415
440 480 500 600
Common ControlT 
Coil Voltage Code
50 Hz A T N G B M
60 Hz H L A N B C
Separate Control (without transformer)
Coil Voltage Code
50 Hz K Y D
60 Hz J X D T
  

µ Overload Relay Code

The Cat. No. as listed is incomplete. Select two overload relay codes from Bulletin 193 E1 Plus electronic overload relay for 3-phase applications:
Selectable Trip Class 10, 15, 20, 30, selectable manual/auto reset
to complete the Cat. No. The first code will denote the high speed overload relay, and the second code will denote the low speed overload relay.


¬ For single-phase (1Æ) applications, consult your local Rockwell Automation sales office or Allen-Bradley distributor.
T When selecting a factory-installed control circuit transformer (see Modifications), use the Common Control Coil Voltage Code to denote the transformer primary voltage. The starter coil and transformer secondary voltage will both be 120V by default. Example: Cat. No. 120E-C09FBµµ-6P will have a transformer with a 480V primary/120V secondary and a 120V starter coil. If a starter coil voltage other than 120V is desired, a second Coil Voltage Code must be added to denote the coil/transformer secondary voltage. Example: Cat. No. 12E-C09FBJµµ-6P will have a transformer with a 480V primary/24V secondary and a 24V starter coil.