Bulletin 109-C IEC Non-Reversing Starters

Click to enlarge - 109-259-1 Click to enlarge - enclosure_start-stop_top_right Click to enlarge - DSCN0868
Cat. No. 109-C09ABA1F-1-4R-6P
IP42 (Type 1)
Metal Enclosure with Lift-off Cover
Molded Plastic Enclosures

Bulletin 109 IEC Non-Reversing Starters — Compact and Standard


Bulletin 109 enclosed starters are designed using Bulletin 100 contactors (9…85 A) and Bulletin 193 bimetallic (Class 10) or solid-state overload relays in a metal or molded plastic enclosure.

Your order must include: Cat. No. of the starter selected, coil voltage code, overload relay suffix code, and, if required, factory-installed modifications suffix code and/or cat. no. of any accessories.

Standards Compliance and Certifications

Standards Compliance

EN/IEC 60947-4-1
VDE 0660
CSA C22.2 No. 14
UL 508


Certifications

cULus Listed (File E3125,
Guide NLDX, NLDX7)


Catalog Number Explanation

Examples given in this section are for reference purposes. This basic explanation should not be used for product selection; not all combinations will produce a valid cat. no. Refer to the tables on the following pages for descriptions of options.

IEC Non-Reversing Starters in Plastic Enclosures

109 CA    K    D    2 E1P 4G 7
a    b    c    d    e    f    g    g

a    b    c    d
Bulletin No. Contactor Size Enclosure Coil Voltage Code — AC Voltage
Code Description Code Description Code Description Code Description
109 IEC Non-reversing starter CA 100-C09 K Plastic Encl. PC, IP66, Type 12K/4/4X Q 12V, 60 Hz
  CB 100-C12   R 12V, 50 Hz
CC 100-C16 J 24V, 60 Hz
CD 100-C23 K 24V, 50 Hz
  KJ 24V, 50/60 Hz
V 32V, 50 Hz / 36V, 60 Hz
W 36V, 50 Hz
X 42V, 50 Hz / 48V, 60 Hz
Y 48V, 50 Hz
KY 48V, 50/60 Hz
KP 100V, 50 Hz / 100...110V, 60 Hz
D 110V, 50 Hz / 120V, 60 Hz
KD 110V, 50/60 Hz
P 120V, 50 Hz
S 127V, 50 Hz
KG 200V, 50 Hz / 200…220V, 60 Hz
KL 200…230V, 50/60 Hz
L 208...240V, 60 Hz
F 220...230V, 50 Hz
KF 230V, 50/60 Hz
A 240V, 60 Hz
T 240V, 50 Hz / 277V, 60 Hz
E 380V, 60 Hz
N 380...400V, 50 Hz / 440V, 60 Hz
KN 400V, 50/60 Hz
G 400...415V, 50 Hz
KB 440V, 50/60 Hz
B 440V, 50 Hz / 480V, 60 Hz
M 500V, 50 Hz
C 550V, 50/60 Hz0V, 60 Hz
      
e    f    g     
Auxiliary Contacts Overload Relay Modifications and Accessories
Code Description 193-ED/ -EE 3-phase Electronic Overload Relay Code Description
0 N.O. Aux.Contact used in Start/Stop Circuit Code Description R Surge Suppressor RC
2 N.O. for Customer Use with Reset Option only D1_ Cl.10, Man. Reset (add additional code suffix below) V Surge Suppressor Varistor
  E1_ Aut./Man.Reset, Adj. Class (add additional code suffix below) 2 Push Buttons, START/ raised STOP/RESET (green/red)
Adj. Range/Contactor Size 7 Push Button, RESET (blue)
Code Description MC With Pushbutton Latch for Maintained Control
_A 0.1…0.5 A, 100-C09…C23 Pilot Lights IP66, Type 4/4X/12K
_B 0.2…1.0 A, 100-C09…C23 Code Description
_C 1.0…5.0 A, 100-C09…C23 4G Pilot Light "RUN", Green
_D 3.2…16 A, 100-C09…C23 4R Pilot Light "RUN", Red
_E 5.4…27 A, 100-C16…C23 4Y Pilot Light "Failure", Yellow
193-EE Single-phase Electron. Overload Relay  
Code Description
E1P 1.0...5.0 A, 100-C09…C23
E1R 3.2...16 A, 100-C09…C23
E1S 5.4…27 A, 100-C16…C23

Product Selection

Product Selection — AC-Operated Starters

Standard Enclosed Type — Sheet Metal

Ratings (AC3, AC4) IP42 (Type 1)
General Purpose
Sheet Metal Enclosure (Liftoff Cover)
IP66 (Type 3, 4, 12)
Watertight, Dusttight
Sheet Metal Enclosure
(Hinged Cover)
Max Ie
[A]
kW Hp
3-Phase 1-Phase 3-Phase Cat. No. Cat. No.
380V/415V 115V 230V 200V 230V 460V 575V
9 4 1/2 1-1/2 2 2 5 7-1/2 109-C09Aĵ 109-C09Fĵ
12 5-1/2 1/2 2 3 3 7-1/2 10 109-C12Aĵ 109-C12Fĵ
16 7-1/2 1 3 5 5 10 15 109-C16Aĵ 109-C16Fĵ
23 11 2 3 5 7-1/2 15 15 109-C23Aĵ 109-C23Fĵ
30 15 2 5 7-1/2 10 20 25 109-C30Aĵ 109-C30Fĵ
37 18-1/2 3 5 10 10 25 30 109-C37Aĵ 109-C37Fĵ
43 22 3 7-1/2 10 15 30 30 109-C43Aĵ 109-C43Fĵ
60 30 5 10 15 20 40 50 109-C60Aĵ 109-C60Fĵ
72 37 5 15 20 25 50 60 109-C72Aĵ 109-C72Fĵ
85 45 7-1/2 15 25 30 60 60 109-C85Aĵ 109-C85Fĵ
  

Ä Coil Voltage Code

The Cat. No. as listed is incomplete. Select a Coil Voltage Code from the table below to complete the Cat. No. Example: Cat. No. 109-C09Aĵ becomes Cat. No.109-C09ABµ.

AC Voltage [V] 24 48 110 120 208 208…240 220 240 277 380…400 400…415 440 480 500 600
Common Control§ 
Coil Voltage Code
50 Hz A T N G B M
60 Hz H L A N B C
Separate Control (without transformer)
Coil Voltage Code
50 Hz K Y D
60 Hz J X D T
  

µ Overload Relay Code

The Cat. No. as listed is incomplete. Select an overload relay code from Bulletin 193 E1 Plus electronic overload relay for 3-phase applications:
Selectable Trip Class 10, 15, 20, 30, selectable manual/auto reset
to complete the Cat. No. Select an overload relay code from E1 Plus Overload Relay for 3Æ Applications: Phase Loss Protection, Class 10 or 20 to complete the Cat. No. Bimetal overload relays are not available in molded plastic enclosed starters.


§ When selecting a factory-installed control circuit transformer (see Full Voltage Non-Reversing Starters and Lighting Contactors (Bulletins 109 with metal enclosures, 100L)), use the Common Control Coil Voltage Code to denote the transformer primary voltage. The starter coil and transformer secondary voltage will both be 120V by default. Example: Cat. No. 109-C09FBµ-6P will have a transformer with a 480V primary/120V secondary and a 120V starter coil. If a starter coil voltage other than 120V is desired, a second Coil Voltage Code must be added to denote the coil/transformer secondary voltage. Example: Cat. No. 109-C09FBJµ-6P will have a transformer with a 480V primary/24V secondary and a 24V starter coil. Control Circuit transformers are not available in molded plastic enclosures


Bulletin 100 Line Starter Accessories

For Bulletins 105, 106, 109, 112, and 113

Click to enlarge - 800F_N6R Description For Use With Bulletin No. Enclosure Type Cat. No.
Red "ON" Pilot Light⋆ 
Full Voltage Type
120V All Metal Lift-off, Metal Hinged, and Molded Plastic ‡  198-PL21R
208V ‡  198-PL25R
240V ‡  198-PL22R
24V 103H Metal Hinged ‡  198-PL26R
120V ‡  198-PL27R
240V ‡  198-PL28R
Click to enlarge - 800F_N6G Green Pilot Light⋆ 
Full Voltage Type
24V All Metal Lift-off, Metal Hinged, and Molded Plastic ‡  198-PL26G
120V All ‡  198-PL21G
240V All ‡  198-PL22G
Click to enlarge - 800F_N6R Dual "ON" Pilot Light⋆ 
Forward — Red
Reverse — White
Full Voltage Type
120V 105, 106 Metal Hinged 198-PL21RW
240V 198-PL22RW
Click to enlarge - 100_Line-267-4 Pilot Device Mounting Bracket
(required when mounting pilot devices in metal lift-off enclosures)
105, 109 Metal Lift-off 198-BR1
Click to enlarge - 100_Line-267-6 Control Circuit Fuse Block
For Class CC rejection type fuses (fuses not included)
All Metal Lift-off and Metal Hinged 1491-R162
Click to enlarge - 100_Line-267-7 Grounding Bushing
Adapts to 1/2 in. N.P.T., PG 16.5 & BS20 mm threads
109 Molded Plastic 198-GR1
Click to enlarge - 100_Line-267-8 Single Pole N.O. Auxiliary Contact for Disconnect Switch 106, 112 Metal Hinged §  195-GA10
Click to enlarge - 100_Line-267-10 Closing Button
For 22.5mm Round Panel Hole
All All 198-N1
Click to enlarge - Push_Button_right "OFF-ON" Selector Switch
2-Position Maintained
All Metal Lift-off and Metal Hinged ‡  198-MT3
  
⋆ Does not include legend plate. See Two-Color Molded Legend Caps — Non-Illuminated Push Buttons for Bulletin 800F Legend Plate. Legend Plates for use on metal-hinged enclosures only.
‡ Requires mounting bracket Cat. No. 198-BR1 when using metal lift-off enclosures.
§ An auxiliary contact adaptor, Cat. No. 194R-AA, is required when installing auxiliary contact, Cat. No. 195-GA10.
♣ 3 required for disconnect switch.

For Bulletins 105, 106, 109, 112, and 113

Click to enlarge - 198_MT1 Description For Use With Bulletin No. Enclosure Type Cat. No.
"HAND-OFF-AUTO" Selector Switch
3-Position Maintained, Includes Legend Plate
105, 106, 109, 112, 113 Metal Lift-off and Metal Hinged ⋆  198-MT1
103H Metal Hinged 198-MT4
"FORWARD-OFF-REVERSE" Selector Switch
3-Position Maintained
105, 106 Metal Lift-off and Metal Hinged ⋆  198-MT2
Click to enlarge - 198_MS3 "START-STOP" Push Button
Flush green "I/START"
Extended red "O/STOP"
105, 109 Metal Lift-off ⋆  198-MS3
103H Metal Hinged 198-MS23
Click to enlarge - 198_MS13 "START" Push Button
Flush green "START"
All Metal Hinged 198-MS13
Click to enlarge - 198_MS6 "ON-OFF" Push Button 105, 109 Metal Lift-off ⋆  198-MS6
Click to enlarge - 198_MS7 "FORWARD, REVERSE-STOP" Push Button 105 Metal Lift-off ⋆  198-MS7
Click to enlarge - 198_MS14 "STOP" Push Button
Flush red "STOP"
All Metal Hinged 198-MS14
Click to enlarge - 198_MS15 "ON" Push Button
Flush green "ON"
All Metal Hinged 198-MS15
Click to enlarge - 198_MS16 "OFF" Push Button
Flush red "OFF"
All Metal Hinged 198-MS16
Click to enlarge - 198_MS17 "FORWARD, REVERSE-STOP"
Push Buttons
105, 106 Metal Hinged 198-MS17
Click to enlarge - 198_MS13 "START" Push Button
Flush green "START"
and
"STOP" Push Button
Flush red "STOP"
103H Metal Hinged 198-MS22
Click to enlarge - 198_MS14
Click to enlarge - 100_Line-269-10 "RESET" Push Button All Metal Lift-off and Metal Hinged ‡  198-MR3
  Wiring Kit for Starters
IEC ModCenter
103H 198-W103H
109 198-W109
112 198-W112
Wiring Kit for Transformers
IEC ModCenter
103H 198-WT2
109, 112 198-WT1
  
⋆ Requires mounting bracket Cat. No. 198-BR1 when using metal lift-off enclosures.
‡ Requires reset adapter Cat. No. 193-RA3 for 193-T1 bimetallic overload relay and reset adapter Cat. No. 193-ERA for Bulletin 193 E1 Plus electronic overload relay.

Modifications

Full Voltage Non-Reversing Starters and Lighting Contactors (Bulletins 109 with metal enclosures, 100L)

Listed on this and the following pages are factory-installed modifications and special features which are available for the low voltage (600V maximum) starters listed in this catalog. To order, add a dash followed by the suffix number listed in these tables to the end of the product Cat. No. Example: Cat. No. 109-C09ADA1E-1

Description of Modification Suffix Code Enclosure Design C09/CA C12/CB C16/CC 100L-C20 C23/CD C30 C37 C43 C60 C72 C85
START-STOP Push Button 1 Metal Lift-off A A A NA A A A A A A A
Metal Hinged A A A NA A A A A A A A
ON-OFF Push Button 1E Metal Lift-off A A A A A A A A A A A
Metal Hinged A A A A A A A A A A A
HAND-OFF-AUTO Selector Switch 3 Metal Lift-off A A A A A A A A A A A
Metal Hinged A A A A A A A A A A A
OFF-ON Selector Switch 3E Metal Lift-off A A A A A A A A A A A
Metal Hinged A A A A A A A A A A A
RUN-Red Pilot Light⋆  4R Plastic Lift-off A A A NA A A A A A A A
RUN-Green Pilot Light⋆  4G A A A NA A A A A A A A
RUN-Yellow Pilot Light⋆  4Y A A A NA A A A A A A A
Red LED Pilot Light (120V) 4R1 Plastic Lift-off A A A NA A NA NA NA NA NA NA
Red LED Pilot Light (240V) 4R2 Plastic Lift-off A A A NA A NA NA NA NA NA NA
Control Circuit Transformer 2 Primary and 1 Secondary Fuse Provided (Standard Capacity) 6P‡  Metal Lift-off A A A A A A A A A A A
Metal Hinged A A A A A A A A A A A
External Reset 7 Plastic Lift-off A A A NA A NA NA NA NA NA NA
Metal Lift-off A A A NA A A A A A A A
Metal Hinged A A A NA A A A A A A A
Control Circuit Fuse Block 2 Fuses Provided 22 Metal Lift-off A A A A A A A A A A A
Metal Hinged A A A A A A A A A A A
Additional 1 N.O. – 1 N.C. (Side Mount) Auxiliary Contact on Contactor (100L only) 90 Metal Lift-off NA NA NA A NA NA NA NA NA NA NA
Metal Hinged NA NA NA A NA NA NA NA NA NA NA
Additional 1 N.O. – 1 N.C. (Side Mount) Auxiliary Contact on Contactor 901 Metal Lift-off A A A A A A A A A A A
Metal Hinged A A A A A A A A A A A
Additional 1 N.O. – 1 N.C. (Front Mount) Auxiliary Contact on Contactor 901T Metal Lift-off A A A A A A A A A A A
Metal Hinged A A A A A A A A A A A
  
⋆ With Bulletin 800F Integrated LED Module. Pilot light is available for control voltages of 240Vor less. If applicable, seelct a transformer. For starters with molded plastic lift-off enclosures, the voltage of the LED module must equal the starter's coil voltage.

Non-Reversing Circuit Breaker Combination Starters (Bulletin 113)

Description of Modification Suffix
Code
Enclosure
Design
C09 C12 C16 C23 C30 C37 C43 C60 C72 C85
START-STOP Push Button 1 ALL NA NA NA NA A NA A A A NA
HAND-OFF-AUTO 3 ALL NA NA NA NA A NA A A A NA
Red Pilot Light§  4R ALL NA NA NA NA A NA A A A NA
Control Circuit Transformer 2 Primary and 1 Secondary Fuse Provided (Standard Capacity) 6P‡  ALL NA NA NA NA A NA A A A NA
External Reset 7 ALL NA NA NA NA A NA A A A NA
Control Circuit Fuse Block 2 Fuses Provided 22 ALL NA NA NA NA A NA A A A NA
Additional 1 N.O. - 1 N.C. (Side Mount) Auxiliary Contact on Contactor 901 ALL NA NA NA NA A NA A A A NA
Additional 1 N.O. - 1 N.C. (Front Mount) Auxiliary Contact on Contactor 901T ALL NA NA NA NA A NA A A A NA
  
A=Available Option
NA=Not Available
§ Transformer Type.
‡ When ordering in Canada, use suffix 6. Primary fusing is not required by the Canadian Electrical Code.

Full Voltage Reversing and Multi-Speed Starters (Bulletin 105 with metal enclosures)

Description of Modification Suffix
Code
Enclosure Design C09 C12 C16 C23 C30 C37 C43 C60 C72 C85
FOR-REV-STOP Push Buttons (105 Only) 1 Metal Lift-off A A A A A A A A A NA
Metal Hinged A A A A A A A A A A
FOR-OFF-REV Selector Switch (105 Only) 3 Metal Lift-off A A A A A A A A A NA
Metal Hinged A A A A A A A A A A
Red FOR/ White REV Pilot Lights⋆  (105 Only) 4RW Metal Hinged A A A A A A A A A A
A A A A A A A A A A
Control Circuit Transformer 2 Primary and 1 Secondary Fuse Provided (Standard Capacity) 6P‡  ALL A A A A A A A A A A
1 External Reset (105 Only) 7 ALL A A A A A A A A A A
Control Circuit Fuse Block 2 Fuses Provided 22 ALL A A A A A A A A A A
Additional 1 N.O. – 1 N.C. (Side Mount) Auxiliary Contact on Each Contactor 901 ALL A A A A A A A A A A
Additional 1 N.O. – 1 N.C. (Front Mount) Auxiliary Contact on Each Contactor 901T ALL A A A A A A A A A A
  

Reversing and Non-Reversing Fusible Combination Starters (Bulletins 106, 112)

Description of Modification Suffix
Code
Enclosure
Design
C09 C12 C16 C23 C30 C37 C43 C60 C72 C85
START-STOP Push Button (112 Only) 1 ALL A A NA A A NA A A A NA
FOR-REV-STOP Push Buttons (106 Only) 1 ALL A A NA A A NA A A A NA
HAND-OFF-AUTO Selector Switch (112 Only) 3 ALL A A NA A A NA A A A NA
FOR-REV-STOP Selector Switch (106 Only) 3 ALL A A NA A A NA A A A NA
Red Pilot Light⋆  (112 Only) 4R ALL A A NA A A NA A A A NA
Red FOR/ White REV Pilot Lights⋆  (106 Only) 4RW ALL A A NA A A NA A A A NA
Control Circuit Transformer 2 Primary and 1 Secondary Fuse Provided (Standard Capacity) 6P‡  ALL A A NA A A NA A A A NA
External Reset 7 ALL A A NA A A NA A A A NA
Fuse Cover For Disconnect Switch 8 ALL A A NA A A NA A A A NA
Control Circuit Fuse Block 2 Fuses Provided 22 ALL A A NA A A NA A A A NA
N.O. Auxiliary Contact On Disconnect Switch 98 ALL A A NA A A NA A A A NA
Additional 1 N.O. – 1 N.C. (Side Mount) Auxiliary Contact on Contactor (112 Only) 901 ALL A A NA A A NA A A A NA
Additional 1 N.O. – 1 N.C. (Side Mount) Auxiliary Contact on each Contactor (106 Only) 901 ALL A A NA A A NA A A A NA
Additional 1 N.O. – 1 N.C. (Front Mount) Auxiliary Contact on Contactor (112 Only) 901T ALL A A NA A A NA A A A NA
Additional 1 N.O. – 1 N.C. (Front Mount) Auxiliary Contact on each Contactor (106 Only) 901T ALL A A NA A A NA A A A NA
  
A=Available Option
NA=Not Available
⋆ Transformer Type.
‡ When ordering in Canada, use suffix 6. Primary fusing is not required by the Canadian Electrical Code.

Bul. 100 Line Starters Approximate Dimensions

Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.

Bulletin 109 Plastic Lift-Off Enclosure

Click to enlarge - 109_plastic_dim


Cat. Nos. 198E-C2S4, -C0S4R, and -C0C4R Plastic Enclosures

Approximate dimensions are shown in millimeters (inches). Dimensions are not to be used for manufacturing purposes.

Click to enlarge - Dim 198E-C0C4R V2
Cat. No. 198E-C0C4R


Click to enlarge - Dim 198E-C0S4R
Cat. No. 198E-C0S4R


Approximate dimensions are shown in millimeters (inches). Dimensions are not to be used for manufacturing purposes.

Click to enlarge - Dim 198E-C2S4 V2
Cat. No. 198E-C2S4


Bulletin 109 Metal Lift-Off Enclosures Type 1 (IP42)

Click to enlarge - 100_Line-273-3


Contactor Size A Height B Width C Depth D E F
IP42 (Type 1) General Purpose Metal Lift-Off Enclosure for Bulletin 109 (Without Transformer)
C09…C23 315
(12-27/64)
188
(7-23/64)
203
(8)
270
(10-5/8)
140
(5-33/64)
24
(15/16)
C30…C43
C60…C72 305
(12)
178
(7)
203
(8)
270
(10-5/8)
140
(5-33/64)
24
(15/16)
C85 585
(23-1/32)
257
(10-7/64)
203
(8)
540
(21-17/64)
210
(8-17/64)
23.5
(59/64)
IP42 (Type 1) General Purpose Metal Lift-Off Enclosure for Bulletin 109 (With Transformer)
C09…C23 305
(12)
178
(7)
203
(8)
245
(9-41/64)
140
(5-33/64)
24
(15/16)
C30…C43 290
(11-27/64)
270
(10-5/8)
152
(5-31/32)
245
(9-41/64)
225
(8-55/64)
22.5
(57/64)
C60…C72 315
(12-27/64)
325
(12-51/64)
203
(8)
270
(10-5/8)
280
(11-1/64)
22.5
(57/64)
C85 585
(23-1/32)
257
(10-7/64)
203
(8)
540
(21-17/64)
210
(8-17/64)
23.5
(59/64)
  

Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.

Bulletins 105 and 120E Metal Lift-Off Enclosures Type 1 (IP42)

Click to enlarge - 100_Line-274-1
Metal Lift-Off


Contactor Size A Height B Width C Depth D E F G (dia.)
IP42 (Type 1) General Purpose Metal Lift-off Enclosure for Bulletin 105 and 120E (Without Transformer)
C09…C23 220
(8-21/32)
235
(9-1/4)
152
(5-31/32)
175
(6-57/64)
190
(7-31/64)
22.5
(57/64)
C30…C43 290
(11-27/64)
270
(10-5/8)
152
(5-31/32)
245
(9-41/32)
225
(8-55/64)
22.5
(57/64)
C60…C72 315
(12-27/64)
325
(12-51/64)
203
(8)
270
(10-5/8)
280
(11-1/64)
22.5
(57/64)
C85 610
(24)
406
(16)
230
(9-1/16)
572
(22-1/2)
368
(14-1/2)
19
(3/4)
11
(7-16)
IP42 (Type 1) General Purpose Metal Lift-Off Enclosure for Bulletin 105 and 120E (With Transformer)
C09…C23 290
(11-27/64)
270
(10-5/8)
152
(5-31/32)
245
(9-41/64)
225
(8-55/64)
22.5
(57/64)
C30…C43 315
(12-27/64)
325
(12-51/64)
203
(8)
270
(10-5/8)
280
(11-1/64)
22.5
(57/64)
  

Bulletins 106, 112, and 113 Metal Hinged Enclosures Type 1 (IP42), Type 3/4/12 (IP66)

Click to enlarge - 100_Line-274-2


Contactor Size A Height B Width C Depth D E F G (dia.)
IP42 (Type 1) and IP66 (Type 3/4/12) General Purpose Metal Hinged Enclosure for Bulletin 106 (With and Without Transformer)
C30…C43 350
(13-25/32)
400
(15-3/4)
200
(7-7/8)
315
(12-13/32)
178
(7)
62
(2-7/16)
6.4
(1/4)
C60…C72 610
(24)
406
(16)
224
(8-13/16)
572
(22-1/2)
368
(14-1/2)
19
(3/4)
12.7
(1/2)
IP42 (Type 1) and IP66 (Type 3/4/12) General Purpose Metal Hinged Enclosure for Bulletin 112 (With and Without Transformer)
C09…C23 350
(13-25/32)
200
(7-7/8)
200
(7-7/8)
315
(12-13/32)
76
(3)
62
(2-7/16)
6.4
(1/4)
C30…C43 350
(13-25/32)
400
(15-3/4)
200
(7-7/8)
315
(12-13/32)
178
(7)
111
(4-3/8)
6.4
(1/4)
C60…C72 610
(24)
406
(16)
224
(8-13/16)
572
(22-1/2)
368
(14-1/2)
19
(3/4)
12.7
(1/2)
IP42 (Type 1) and IP66 (Type 3/4/12) General Purpose Metal Hinged Enclosure for Bulletin 113 (With and Without Transformer)
C30…C72 610
(24)
406
(16)
224
(8-13/16)
572
(22-1/2)
368
(14-1/2)
19
(3/4)
12.7
(1/2)
  

Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.

Bulletin 109 Metal Hinged Enclosures Type 3/4/12 (IP66)

Click to enlarge - 100_Line-275-1


Contactor Size A Height B Width C Depth D E F G (dia.)
IP66 (Type 3/4/12) Metal Hinged Enclosure for Bulletin 109 (Without Transformer)
C09…C43 300
(11-13/16)
200
(7-7/8)
160
(6-5/16)
265
(10-7/16)
76
(3)
62
(2-7/16)
5.5
(7/32)
C60…C72 350
(13/25/32)
200
(7-7/8)
210
(8-9/32)
315
(12-13/32)
76
(3)
62
(2-7/16)
5.5
(7/32)
C85 762
(30)
305
(12)
276
(10-7/8)
724
(28-1/2)
267
(10-1/2)
19
(3/4)
11
(7/16)
IP66 (Type 3/4/12) Metal Hinged Enclosure for Bulletin 109 (With Transformer)
C09…C23 300
(11-13/16)
200
(7-7/8)
160
(6-5/16)
265
(10-7/16)
76
(3)
62
(2-7/16)
5.5
(7/32)
C30…C43 300
(11-13/16)
300
(11-13/16)
160
(6-5/16)
236
(9-5/16)
178
(7)
61
(2-13/32)
5.5
(7/32)
C60…C72 350
(13-25/32)
400
(15-3/4)
210
(8-9/32)
315
(12-13/32)
178
(7)
111
(4-3/8)
5.5
(7/32)
C85 610
(24)
406
(16)
230
(9-1/16)
572
(22-1/2)
368
(14-1/2)
19
(3/4)
11
(7/16)
  

Bulletins 105 and 120E Metal Hinged Enclosures Type 3/4/12 (IP66)

Click to enlarge - 100_Line-275-2


Contactor Size A Height B Width C Depth D E (Mtg.) F G (dia.)
IP66 (Type 3/4/12) Metal Hinged Enclosure for Bulletins 105 and 120E (Without Transformer)
C09…C23 250
(9-13/16)
250
(9-13/16)
160
(6-5/16)
186
(7-5/16)
76
(3)
87
(3-13/32)
5.5
(7/32)
C30…C43 300
(11-13/16)
300
(11-13/16)
160
(6-5/16)
236
(9-5/16)
178
(7)
61
(2-13/32)
5.5
(7/32)
C60…C72 350
(13/25/32)
400
(15-3/4)
210
(8-9/32)
315
(12-13/32)
178
(7)
111
(4-3/8)
5.5
(7/32)
C85 610
(24)
406
(16)
230
(9-1/06)
572
(22-1/2)
368
(14-1/2)
19
(3/4)
11
(7/16)
IP66 (Type 3/4/12) Metal Hinged Enclosure for Bulletins 105 and 120E (With Transformer)
C09…C23 300
(11-13/16)
300
(11-13/16)
160
(6-5/16)
236
(9-5/16)
178
(7)
61
(2-13/32)
5.5
(7/32)
C30…C43 350
(13-25/32)
400
(15-3/4)
210
(8-9/32)
315
(12-13/32)
178
(7)
111
(4-3/8)
5.5
(7/32)
C60…C72 610
(24)
406
(16)
230
(9-1/06)
572
(22-1/2)
368
(14-1/2)
19
(3/4)
11
(7/16)
C85 762
(30)
610
(24)
281
(11-1/16)
724
(28-1/2)
572
(22-1/2)
19
(3/4)
11
(7/16)
  

Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.

Bulletins 132 and 133 Metal Hinged Enclosures with Extra Space Type 3R (IP32)

Click to enlarge - 198_d


Contactor Size A Height B Width C Depth D E F G H J K
IP 32 (Type 3R) Rainproof Metal Hinged Enclosure for Bulletins 132 and 133 (With and Without Transformer)
C09…C43 584
(23)
320
(12-19/32)
187
(7-5/16)
711
(28)
105
(4-1/8)
108
(4-1/4)
679
(26-3/4)
667
(26-1/4)
105
(4-1/8)
105
(4-1/8)
C60…C72 864
(34)
447
(17-19/32)
238
(9-5/16)
991
(39)
105
(4-1/8)
171
(6-3/4)
959
(37-3/4)
946
(37-1/4)
105
(4-1/8)
169
(6-12/32)
B110 1067
(42)
762
(30)
305
(12)
1118
(44)
686
(27)
38
(1-1/2)
1092
(43)
1092
(43)
B180…B250 1219
(48)
914
(36)
305
(12)
1270
(50)
686
(27)
114
(4-1/2)
1245
(49)
1245
(49)