Bulletin 109-C IEC Non-Reversing Starters
|
|
| Cat. No. 109-C09ABA1F-1-4R-6P IP42 (Type 1) Metal Enclosure with Lift-off Cover |
Cat. No. 109-CAKD2-E1A-7 Molded Plastic Enclosure |
Bulletin 109 IEC Non-Reversing Starters
- Impact-resistant molded enclosures (9…23 A)
IP66 (Type 4/4X/12)
- Selection of metal enclosures (9…85 A)
IP42 (Type 1)
IP66 (Type 3/4/12)
- Bimetallic Class 10 overload relays
- Solid-state overload relays
- Compact design
- Meets international standards
Bulletin 109 enclosed starters are designed using Bulletin 100 contactors (9…85 A) and Bulletin 193 bimetallic (Class 10) or solid-state overload relays in a metal or molded plastic enclosure.
Your order must include: Cat. No. of the starter selected, coil voltage code, overload relay suffix code, and, if required, factory-installed modifications suffix code and/or cat. no. of any accessories.
Standards Compliance and Certifications
Standards Compliance
EN/IEC 60947-4-1
VDE 0660
CSA C22.2 No. 14
UL 508
Certifications
cULus Listed (File E3125,
Guide NLDX, NLDX7)
Catalog Number Explanation
Examples given in this section are for reference purposes. This basic explanation should not be used for product selection; not all combinations will produce a valid cat. no. Refer to the tables on the following pages for descriptions of options.
IEC Non-Reversing Starters in Plastic Enclosures
| 109 | | CA | K | D | 2 | | E1P | | 4G | | 7 | |||
| a | b | c | d | e | f | g | g |
| a | b | c | d | |||||||||
| Bulletin No. | Contactor Size | Enclosure | Coil Voltage Code — AC Voltage | |||||||||
| Code | Description | Code | Description | Code | Description | Code | Description | |||||
| 109 | IEC Non-reversing starter | CA | 100-C09 | K | Plastic Encl. PC, IP66, Type 12K/4/4X | Q | 12V, 60 Hz | |||||
| CB | 100-C12 | R | 12V, 50 Hz | |||||||||
| CC | 100-C16 | J | 24V, 60 Hz | |||||||||
| CD | 100-C23 | K | 24V, 50 Hz | |||||||||
| KJ | 24V, 50/60 Hz | |||||||||||
| V | 32V, 50 Hz / 36V, 60 Hz | |||||||||||
| W | 36V, 50 Hz | |||||||||||
| X | 42V, 50 Hz / 48V, 60 Hz | |||||||||||
| Y | 48V, 50 Hz | |||||||||||
| KY | 48V, 50/60 Hz | |||||||||||
| KP | 100V, 50 Hz / 100...110V, 60 Hz | |||||||||||
| D | 110V, 50 Hz / 120V, 60 Hz | |||||||||||
| KD | 110V, 50/60 Hz | |||||||||||
| P | 120V, 50 Hz | |||||||||||
| S | 127V, 50 Hz | |||||||||||
| KG | 200V, 50 Hz / 200…220V, 60 Hz | |||||||||||
| KL | 200…230V, 50/60 Hz | |||||||||||
| L | 208...240V, 60 Hz | |||||||||||
| F | 220...230V, 50 Hz | |||||||||||
| KF | 230V, 50/60 Hz | |||||||||||
| A | 240V, 60 Hz | |||||||||||
| T | 240V, 50 Hz / 277V, 60 Hz | |||||||||||
| E | 380V, 60 Hz | |||||||||||
| N | 380...400V, 50 Hz / 440V, 60 Hz | |||||||||||
| KN | 400V, 50/60 Hz | |||||||||||
| G | 400...415V, 50 Hz | |||||||||||
| KB | 440V, 50/60 Hz | |||||||||||
| B | 440V, 50 Hz / 480V, 60 Hz | |||||||||||
| M | 500V, 50 Hz | |||||||||||
| C | 550V, 50/60 Hz0V, 60 Hz | |||||||||||
| e | f | g | ||||||||||
| Auxiliary Contacts | Overload Relay | Modifications and Accessories | ||||||||||
| Code | Description | 193-ED/ -EE 3-phase Electronic Overload Relay | Code | Description | ||||||||
| 0 | N.O. Aux.Contact used in Start/Stop Circuit | Code | Description | R | Surge Suppressor RC | |||||||
| 2 | N.O. for Customer Use with Reset Option only | D1_ | Cl.10, Man. Reset (add additional code suffix below) | V | Surge Suppressor Varistor | |||||||
| E1_ | Aut./Man.Reset, Adj. Class (add additional code suffix below) | 2 | Push Buttons, START/ raised STOP/RESET (green/red) | |||||||||
| Adj. Range/Contactor Size | 7 | Push Button, RESET (blue) | ||||||||||
| Code | Description | MC | With Pushbutton Latch for Maintained Control | |||||||||
| _A | 0.1…0.5 A, 100-C09…C23 | Pilot Lights IP66, Type 4/4X/12K | ||||||||||
| _B | 0.2…1.0 A, 100-C09…C23 | Code | Description | |||||||||
| _C | 1.0…5.0 A, 100-C09…C23 | 4G | Pilot Light "RUN", Green | |||||||||
| _D | 3.2…16 A, 100-C09…C23 | 4R | Pilot Light "RUN", Red | |||||||||
| _E | 5.4…27 A, 100-C16…C23 | 4Y | Pilot Light "Failure", Yellow | |||||||||
| 193-EE Single-phase Electron. Overload Relay | ||||||||||||
| Code | Description | |||||||||||
| E1P | 1.0...5.0 A, 100-C09…C23 | |||||||||||
| E1R | 3.2...16 A, 100-C09…C23 | |||||||||||
| E1S | 5.4…27 A, 100-C16…C23 | |||||||||||
Product Selection
Product Selection — AC-Operated Starters
Enclosed Type — Molded Plastic
| Ratings (AC3, AC4) | IP66 (Type 4, 4X, 12) Watertight, Dusttight Corrosion Resistant Molded Plastic Enclosure |
||||||||
| Max Ie [A] |
kW | Hp | With integral Start/Stop Push Butotn | With integral Reset Push Butotn | |||||
| 3Æ | 1Æ | 3Æ | |||||||
| 380V/415V | 115V | 230V | 200V | 230V | 460V | 575V | Cat. No.¬ | Cat. No.¬ | |
| 9 | 4 | 1/2 | 1-1/2 | 2 | 2 | 5 | 7-1/2 | 109-CAKÄ0-µ-2 | 109-CAKÄ0-µ-7 |
| 12 | 5-1/2 | 1/2 | 2 | 3 | 3 | 7-1/2 | 10 | 109-CBKÄ0-µ-2 | 109-CBKÄ0-µ-7 |
| 16 | 7-1/2 | 1 | 3 | 5 | 5 | 10 | 15 | 109-CCKÄ0-µ-2 | 109-CCKÄ0-µ-7 |
| 23 | 11 | 2 | 3 | 5 | 7-1/2 | 15 | 15 | 109-CDKÄ0-µ-2 | 109-CDKÄ0-µ-7 |
| ¬ N.O. auxiliary contact is used as holding contact with the START/STOP option. N.O. auxiliary contact is available for customer use with RESET option. |
|||||||||
Enclosed Type — Sheet Metal
| Ratings (AC3, AC4) | IP42 (Type 1) General Purpose Sheet Metal Enclosure (Liftoff Cover) |
IP66 (Type 3, 4, 12) Watertight, Dusttight Sheet Metal Enclosure (Hinged Cover) |
|||||||
| Max Ie [A] |
kW | Hp | |||||||
| 3Æ | 1Æ | 3Æ | Cat. No. | Cat. No. | |||||
| 380V/415V | 115V | 230V | 200V | 230V | 460V | 575V | |||
| 9 | 4 | 1/2 | 1-1/2 | 2 | 2 | 5 | 7-1/2 | 109-C09Aĵ | 109-C09Fĵ |
| 12 | 5-1/2 | 1/2 | 2 | 3 | 3 | 7-1/2 | 10 | 109-C12Aĵ | 109-C12Fĵ |
| 16 | 7-1/2 | 1 | 3 | 5 | 5 | 10 | 15 | 109-C16Aĵ | 109-C16Fĵ |
| 23 | 11 | 2 | 3 | 5 | 7-1/2 | 15 | 15 | 109-C23Aĵ | 109-C23Fĵ |
| 30 | 15 | 2 | 5 | 7-1/2 | 10 | 20 | 25 | 109-C30Aĵ | 109-C30Fĵ |
| 37 | 18-1/2 | 3 | 5 | 10 | 10 | 25 | 30 | 109-C37Aĵ | 109-C37Fĵ |
| 43 | 22 | 3 | 7-1/2 | 10 | 15 | 30 | 30 | 109-C43Aĵ | 109-C43Fĵ |
| 60 | 30 | 5 | 10 | 15 | 20 | 40 | 50 | 109-C60Aĵ | 109-C60Fĵ |
| 72 | 37 | 5 | 15 | 20 | 25 | 50 | 60 | 109-C72Aĵ | 109-C72Fĵ |
| 85 | 45 | 7-1/2 | 15 | 25 | 30 | 60 | 60 | 109-C85Aĵ | 109-C85Fĵ |
Ä Coil Voltage Code
The Cat. No. as listed is incomplete. Select a Coil Voltage Code from the table below to complete the Cat. No. Example: Cat. No. 109-C09Aĵ becomes Cat. No.109-C09ABµ.
| AC Voltage [V] | 24 | 48 | 110 | 120 | 208 | 208…240 | 220 | 240 | 277 | 380…400 | 400…415 | 440 | 480 | 500 | 600 | |
| Common Control Coil Voltage Code |
50 Hz | — | — | — | — | — | — | A | T | — | N | G | B | — | M | — |
| 60 Hz | — | — | — | — | H | L | — | A | — | — | — | N | B | — | C | |
| Separate Control (without transformer) Coil Voltage Code |
50 Hz | K | Y | D | — | — | — | — | — | — | — | — | — | — | — | — |
| 60 Hz | J | X | — | D | — | — | — | — | T | — | — | — | — | — | — | |
µ Overload Relay Code
The Cat. No. as listed is incomplete. Select an overload relay code from Bulletin 193 E1 Plus electronic overload relay for 3-phase applications:
Selectable Trip Class 10, 15, 20, 30, selectable manual/auto reset to complete the Cat. No. Select an overload relay code from E1 Plus Overload Relay for 3Æ Applications: Phase Loss Protection, Class 10 or 20 to complete the Cat. No. Bimetal overload relays are not available in molded plastic enclosed starters.
When selecting a factory-installed control circuit transformer (see Modifications), use the Common Control Coil Voltage Code to denote the transformer primary voltage. The starter coil and transformer secondary voltage will both be 120V by default. Example: Cat. No. 109-C09FBµ-6P will have a transformer with a 480V primary/120V secondary and a 120V starter coil. If a starter coil voltage other than 120V is desired, a second Coil Voltage Code must be added to denote the coil/transformer secondary voltage. Example: Cat. No. 109-C09FBJµ-6P will have a transformer with a 480V primary/24V secondary and a 24V starter coil. Control Circuit transformers are not available in molded plastic enclosures
Bulletin 100 Line Starter Accessories
For Bulletins 105, 106, 109, 112, 113, 120E, 132, and 133
|
Description | For Use With | Enclosure Type | Cat. No. | ||
| Red "ON" Pilot Light¬ Full Voltage Type |
120V | All | Metal Lift-off, Metal Hinged, and Molded Plastic | T | 198-PL21R | |
| 208V | T | 198-PL25R | ||||
| 240V | T | 198-PL22R | ||||
|
Dual "ON" Pilot Light¬ Forward — Red Reverse — White Full Voltage Type |
120V | 105, 106 | Metal Hinged | 198-PL21RW | |
| 240V | 198-PL22RW | |||||
|
Pilot Device Mounting Bracket (required when mounting pilot devices in metal lift-off enclosures) |
105, 109, 120E | Metal Lift-off | 198-BR1 | ||
|
Control Circuit Transformer With Top-Mounted Fuse Block |
All | Metal Lift-off and Metal Hinged | |||
|
Control Circuit Fuse Block For Class CC rejection type fuses (fuses not included) |
All | Metal Lift-off and Metal Hinged | 1491-R162 | ||
|
Grounding Bushing Adapts to 1/2 in. N.P.T., PG 16.5 & BS20 mm threads |
109 | Molded Plastic | 198-GR1 | ||
|
Single Pole N.O. Auxiliary Contact for Disconnect Switch | 106, 112 | Metal Hinged | | 195-GA10 | |
|
Fuse Cover for Disconnect Switch | 106,112,132-C09…C23 | Metal Hinged | 194R-FCA2 | ||
| 106,112,132-C30…C43 | 194R-FCJ60 | |||||
| 106,112,132-C60…C72 | § | 194R-FCC1 | ||||
|
Closing Button For 22.5mm Round Panel Hole |
All | All | 198-N1 | ||
|
"OFF-ON" Selector Switch 2-Position Maintained |
All | Metal Lift-off and Metal Hinged | T | 198-MT3 | |
| ¬ Does not include legend plate. See Two-Color Molded Legend Caps — Non-Illuminated Push Buttons for Bulletin 800F Legend Plate. Legend Plates for use on metal-hinged enclosures only. | ||||||
| T Requires mounting bracket Cat. No. 198-BR1 when using metal lift-off enclosures. | ||||||
| An auxiliary contact adaptor, Cat. No. 194R-AA, is required when installing auxiliary contact, Cat. No. 195-GA10. | ||||||
| § 3 required for disconnect switch. | ||||||
For Bulletins 105, 106, 109, 112, 113, 120E, 132, and 133
For Bulletins 105, 106, 109, 112, 113, 120E, 132, and 133
Modifications
Full Voltage Non-Reversing Starters and Lighting Contactors (Bulletins 109, 100L)
Listed on this and the following pages are factory-installed modifications and special features which are available for the low voltage (600V maximum) starters listed in this catalog. To order, add a dash followed by the suffix number listed in these tables to the end of the product Cat. No. Example: Cat. No. 109-C09ADA1E-1
| Description of Modification | Suffix Code | Enclosure Design | C09/CA | C12/CB | C16/CC | 100L-C20 | C23/CD | C30 | C37 | C43 | C60 | C72 | C85 |
| START-STOP Push Button | 1 | Metal Lift-off | A | A | A | NA | A | A | A | A | A | A | A |
| Metal Hinged | A | A | A | NA | A | A | A | A | A | A | A | ||
| ON-OFF Push Button | 1E | Metal Lift-off | A | A | A | A | A | A | A | A | A | A | A |
| Metal Hinged | A | A | A | A | A | A | A | A | A | A | A | ||
| HAND-OFF-AUTO Selector Switch | 3 | Metal Lift-off | A | A | A | A | A | A | A | A | A | A | A |
| Metal Hinged | A | A | A | A | A | A | A | A | A | A | A | ||
| OFF-ON Selector Switch | 3E | Metal Lift-off | A | A | A | A | A | A | A | A | A | A | A |
| Metal Hinged | A | A | A | A | A | A | A | A | A | A | A | ||
| RUN-Red Pilot Light¬ | 4R | Plastic Lift-off | A | A | A | NA | A | A | A | A | A | A | A |
| RUN-Green Pilot Light¬ | 4G | A | A | A | NA | A | A | A | A | A | A | A | |
| RUN-Yellow Pilot Light¬ | 4Y | A | A | A | NA | A | A | A | A | A | A | A | |
| Red LED Pilot Light (120V) | 4R1 | Plastic Lift-off | A | A | A | NA | A | NA | NA | NA | NA | NA | NA |
| Red LED Pilot Light (240V) | 4R2 | Plastic Lift-off | A | A | A | NA | A | NA | NA | NA | NA | NA | NA |
| Control Circuit Transformer 2 Primary and 1 Secondary Fuse Provided (Standard Capacity) | 6PT | Metal Lift-off | A | A | A | A | A | A | A | A | A | A | A |
| Metal Hinged | A | A | A | A | A | A | A | A | A | A | A | ||
| External Reset | 7 | Plastic Lift-off | A | A | A | NA | A | NA | NA | NA | NA | NA | NA |
| Metal Lift-off | A | A | A | NA | A | A | A | A | A | A | A | ||
| Metal Hinged | A | A | A | NA | A | A | A | A | A | A | A | ||
| Control Circuit Fuse Block 2 Fuses Provided | 22 | Metal Lift-off | A | A | A | A | A | A | A | A | A | A | A |
| Metal Hinged | A | A | A | A | A | A | A | A | A | A | A | ||
| Additional 1 N.O. 1 N.C. (Side Mount) Auxiliary Contact on Contactor (100L only) | 90 | Metal Lift-off | NA | NA | NA | A | NA | NA | NA | NA | NA | NA | NA |
| Metal Hinged | NA | NA | NA | A | NA | NA | NA | NA | NA | NA | NA | ||
| Additional 1 N.O. 1 N.C. (Side Mount) Auxiliary Contact on Contactor | 901 | Metal Lift-off | A | A | A | A | A | A | A | A | A | A | A |
| Metal Hinged | A | A | A | A | A | A | A | A | A | A | A | ||
| Additional 1 N.O. 1 N.C. (Front Mount) Auxiliary Contact on Contactor | 901T | Metal Lift-off | A | A | A | A | A | A | A | A | A | A | A |
| Metal Hinged | A | A | A | A | A | A | A | A | A | A | A | ||
| ¬ With Bulletin 800F Integrated LED Module. Pilot light is available for control voltages of 240Vor less. If applicable, seelct a transformer. For starters with molded plastic lift-off enclosures, the voltage of the LED module must equal the starter's coil voltage. | |||||||||||||
Non-Reversing Circuit Breaker Combination Starters (Bulletin 113, 133)
| Description of Modification | Suffix Code |
Enclosure Design |
C09 | C12 | C16 | C23 | C30 | C37 | C43 | C60 | C72 | C85 |
| START-STOP Push Button (113 Only) | 1 | ALL | NA | NA | NA | NA | A | NA | A | A | A | NA |
| HAND-OFF-AUTO (113 Only) | 3 | ALL | NA | NA | NA | NA | A | NA | A | A | A | NA |
| Red Pilot Light¬ | 4R | ALL | NA | NA | NA | NA | A | NA | A | A | A | NA |
| Control Circuit Transformer 2 Primary and 1 Secondary Fuse Provided (Standard Capacity) | 6PT | ALL | NA | NA | NA | NA | A | NA | A | A | A | NA |
| External Reset | 7 | ALL | NA | NA | NA | NA | A | NA | A | A | A | NA |
| Control Circuit Fuse Block 2 Fuses Provided | 22 | ALL | NA | NA | NA | NA | A | NA | A | A | A | NA |
| Additional 1 N.O. - 1 N.C. (Side Mount) Auxiliary Contact on Contactor | 901 | ALL | NA | NA | NA | NA | A | NA | A | A | A | NA |
| Additional 1 N.O. - 1 N.C. (Front Mount) Auxiliary Contact on Contactor | 901T | ALL | NA | NA | NA | NA | A | NA | A | A | A | NA |
| A=Available Option | ||||||||||||
| NA=Not Available | ||||||||||||
| ¬ Transformer Type. | ||||||||||||
| T When ordering in Canada, use suffix 6. Primary fusing is not required by the Canadian Electrical Code. | ||||||||||||
Full Voltage Reversing and Multi-Speed Starters (Bulletins 105, 120E)
| Description of Modification | Suffix Code |
Enclosure Design | C09 | C12 | C16 | C23 | C30 | C37 | C43 | C60 | C72 | C85 |
| FOR-REV-STOP Push Buttons (105 Only) | 1 | Metal Lift-off | A | A | A | A | A | A | A | A | A | NA |
| Metal Hinged | A | A | A | A | A | A | A | A | A | A | ||
| HIGH-LOW-STOP Push Buttons (120E Only) | 1 | Metal Lift-off | A | A | A | A | A | A | A | A | A | NA |
| Metal Hinged | A | A | A | A | A | A | A | A | A | A | ||
| FOR-OFF-REV Selector Switch (105 Only) | 3 | Metal Lift-off | A | A | A | A | A | A | A | A | A | NA |
| Metal Hinged | A | A | A | A | A | A | A | A | A | A | ||
| HIGH-OFF-LOW Selector Switch (120E Only) | 3 | Metal Lift-off | A | A | A | A | A | A | A | A | A | NA |
| Metal Hinged | A | A | A | A | A | A | A | A | A | A | ||
| Red FOR/ White REV Pilot Lights¬ (105 Only) | 4RW | Metal Hinged | A | A | A | A | A | A | A | A | A | A |
| A | A | A | A | A | A | A | A | A | A | |||
| Red HIGH/White LOW Pilot Lights¬ (120E Only) | 4RW | Metal Hinged | A | A | A | A | A | A | A | A | A | A |
| A | A | A | A | A | A | A | A | A | A | |||
| Control Circuit Transformer 2 Primary and 1 Secondary Fuse Provided (Standard Capacity) | 6PT | ALL | A | A | A | A | A | A | A | A | A | A |
| 1 External Reset (105 Only) | 7 | ALL | A | A | A | A | A | A | A | A | A | A |
| 2 External Resets (120E Only) | 7 | ALL | A | A | A | A | A | A | A | A | A | A |
| Control Circuit Fuse Block 2 Fuses Provided | 22 | ALL | A | A | A | A | A | A | A | A | A | A |
| Additional 1 N.O. 1 N.C. (Side Mount) Auxiliary Contact on Each Contactor | 901 | ALL | A | A | A | A | A | A | A | A | A | A |
| Additional 1 N.O. 1 N.C. (Front Mount) Auxiliary Contact on Each Contactor | 901T | ALL | A | A | A | A | A | A | A | A | A | A |
Reversing and Non-Reversing Fusible Combination Starters (Bulletins 106, 112, 132)
| Description of Modification | Suffix Code |
Enclosure Design |
C09 | C12 | C16 | C23 | C30 | C37 | C43 | C60 | C72 | C85 |
| START-STOP Push Button (112 Only) | 1 | ALL | A | A | NA | A | A | NA | A | A | A | NA |
| FOR-REV-STOP Push Buttons (106 Only) | 1 | ALL | A | A | NA | A | A | NA | A | A | A | NA |
| HAND-OFF-AUTO Selector Switch (112 Only) | 3 | ALL | A | A | NA | A | A | NA | A | A | A | NA |
| FOR-REV-STOP Selector Switch (106 Only) | 3 | ALL | A | A | NA | A | A | NA | A | A | A | NA |
| Red Pilot Light¬ | 4R | ALL | A | A | NA | A | A | NA | A | A | A | NA |
| Red FOR/ White REV Pilot Lights¬ (106 Only) | 4RW | ALL | A | A | NA | A | A | NA | A | A | A | NA |
| Control Circuit Transformer 2 Primary and 1 Secondary Fuse Provided (Standard Capacity) | 6PT | ALL | A | A | NA | A | A | NA | A | A | A | NA |
| External Reset | 7 | ALL | A | A | NA | A | A | NA | A | A | A | NA |
| Fuse Cover For Disconnect Switch | 8 | ALL | A | A | NA | A | A | NA | A | A | A | NA |
| Control Circuit Fuse Block 2 Fuses Provided | 22 | ALL | A | A | NA | A | A | NA | A | A | A | NA |
| N.O. Auxiliary Contact On Disconnect Switch | 98 | ALL | A | A | NA | A | A | NA | A | A | A | NA |
| Additional 1 N.O. 1 N.C. (Side Mount) Auxiliary Contact on Contactor (112 and 132 Only) | 901 | ALL | A | A | NA | A | A | NA | A | A | A | NA |
| Additional 1 N.O. 1 N.C. (Side Mount) Auxiliary Contact on each Contactor (106 Only) | 901 | ALL | A | A | NA | A | A | NA | A | A | A | NA |
| Additional 1 N.O. 1 N.C. (Front Mount) Auxiliary Contact on Contactor (112 and 132 Only) | 901T | ALL | A | A | NA | A | A | NA | A | A | A | NA |
| Additional 1 N.O. 1 N.C. (Front Mount) Auxiliary Contact on each Contactor (106 Only) | 901T | ALL | A | A | NA | A | A | NA | A | A | A | NA |
| A=Available Option | ||||||||||||
| NA=Not Available | ||||||||||||
| ¬ Transformer Type. | ||||||||||||
| T When ordering in Canada, use suffix 6. Primary fusing is not required by the Canadian Electrical Code. | ||||||||||||
Bul. 100 Line Starters Approximate Dimensions
Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.
Bulletin 109 Plastic Lift-Off Enclosure
|
Bulletin 109 Metal Lift-Off Enclosures Type 1 (IP42)
|
| Contactor Size | A Height | B Width | C Depth | D | E | F |
| IP42 (Type 1) General Purpose Metal Lift-Off Enclosure for Bulletin 109 (Without Transformer) | ||||||
| C09…C23 | 315 (12-27/64) |
188 (7-23/64) |
203 (8) |
270 (10-5/8) |
140 (5-33/64) |
24 (15/16) |
| C30…C43 | ||||||
| C60…C72 | 305 (12) |
178 (7) |
203 (8) |
270 (10-5/8) |
140 (5-33/64) |
24 (15/16) |
| C85 | 585 (23-1/32) |
257 (10-7/64) |
203 (8) |
540 (21-17/64) |
210 (8-17/64) |
23.5 (59/64) |
| IP42 (Type 1) General Purpose Metal Lift-Off Enclosure for Bulletin 109 (With Transformer) | ||||||
| C09…C23 | 305 (12) |
178 (7) |
203 (8) |
245 (9-41/64) |
140 (5-33/64) |
24 (15/16) |
| C30…C43 | 290 (11-27/64) |
270 (10-5/8) |
152 (5-31/32) |
245 (9-41/64) |
225 (8-55/64) |
22.5 (57/64) |
| C60…C72 | 315 (12-27/64) |
325 (12-51/64) |
203 (8) |
270 (10-5/8) |
280 (11-1/64) |
22.5 (57/64) |
| C85 | 585 (23-1/32) |
257 (10-7/64) |
203 (8) |
540 (21-17/64) |
210 (8-17/64) |
23.5 (59/64) |
Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.
Bulletins 105 and 120E Metal Lift-Off Enclosures Type 1 (IP42)
|
| Contactor Size | A Height | B Width | C Depth | D | E | F | G (dia) |
| IP42 (Type 1) General Purpose Metal Lift-off Enclosure for Bulletin 105 and 120E (Without Transformer) | |||||||
| C09…C23 | 220 (8-21/32) |
235 (9-1/4) |
152 (5-31/32) |
175 (6-57/64) |
190 (7-31/64) |
22.5 (57/64) |
— |
| C30…C43 | 290 (11-27/64) |
270 (10-5/8) |
152 (5-31/32) |
245 (9-41/32) |
225 (8-55/64) |
22.5 (57/64) |
— |
| C60…C72 | 315 (12-27/64) |
325 (12-51/64) |
203 (8) |
270 (10-5/8) |
280 (11-1/64) |
22.5 (57/64) |
— |
| C85 | 610 (24) |
406 (16) |
230 (9-1/16) |
572 (22-1/2) |
368 (14-1/2) |
19 (3/4) |
11 (7-16) |
| IP42 (Type 1) General Purpose Metal Lift-Off Enclosure for Bulletin 105 and 120E (With Transformer) | |||||||
| C09…C23 | 290 (11-27/64) |
270 (10-5/8) |
152 (5-31/32) |
245 (9-41/64) |
225 (8-55/64) |
22.5 (57/64) |
— |
| C30…C43 | 315 (12-27/64) |
325 (12-51/64) |
203 (8) |
270 (10-5/8) |
280 (11-1/64) |
22.5 (57/64) |
— |
Bulletins 106, 112, and 113 Metal Hinged Enclosures Type 1 (IP42), Type 3/4/12 (IP66)
|
| Contactor Size | A Height | B Width | C Depth | D | E | F | G (dia) |
| IP42 (Type 1) and IP66 (Type 3/4/12) General Purpose Metal Hinged Enclosure for Bulletin 106 (With and Without Transformer) | |||||||
| C30…C43 | 350 (13-25/32) |
400 (15-3/4) |
200 (7-7/8) |
315 (12-13/32) |
178 (7) |
62 (2-7/16) |
6.4 (1/4) |
| C60…C72 | 610 (24) |
406 (16) |
224 (8-13/16) |
572 (22-1/2) |
368 (14-1/2) |
19 (3/4) |
12.7 (1/2) |
| IP42 (Type 1) and IP66 (Type 3/4/12) General Purpose Metal Hinged Enclosure for Bulletin 112 (With and Without Transformer) | |||||||
| C09…C23 | 350 (13-25/32) |
200 (7-7/8) |
200 (7-7/8) |
315 (12-13/32) |
76 (3) |
62 (2-7/16) |
6.4 (1/4) |
| C30…C43 | 350 (13-25/32) |
400 (15-3/4) |
200 (7-7/8) |
315 (12-13/32) |
178 (7) |
111 (4-3/8) |
6.4 (1/4) |
| C60…C72 | 610 (24) |
406 (16) |
224 (8-13/16) |
572 (22-1/2) |
368 (14-1/2) |
19 (3/4) |
12.7 (1/2) |
| IP42 (Type 1) and IP66 (Type 3/4/12) General Purpose Metal Hinged Enclosure for Bulletin 113 (With and Without Transformer) | |||||||
| C30…C72 | 610 (24) |
406 (16) |
224 (8-13/16) |
572 (22-1/2) |
368 (14-1/2) |
19 (3/4) |
12.7 (1/2) |
Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.
Bulletin 109 Metal Hinged Enclosures Type 3/4/12 (IP66)
|
| Contactor Size | A Height | B Width | C Depth | D | E | F | G (dia) |
| IP66 (Type 3/4/12) Metal Hinged Enclosure for Bulletin 109 (Without Transformer) | |||||||
| C09…C43 | 300 (11-13/16) |
200 (7-7/8) |
160 (6-5/16) |
265 (10-7/16) |
76 (3) |
62 (2-7/16) |
5.5 (7/32) |
| C60…C72 | 350 (13/25/32) |
200 (7-7/8) |
210 (8-9/32) |
315 (12-13/32) |
76 (3) |
62 (2-7/16) |
5.5 (7/32) |
| C85 | 762 (30) |
305 (12) |
276 (10-7/8) |
724 (28-1/2) |
267 (10-1/2) |
19 (3/4) |
11 (7/16) |
| IP66 (Type 3/4/12) Metal Hinged Enclosure for Bulletin 109 (With Transformer) | |||||||
| C09…C23 | 300 (11-13/16) |
200 (7-7/8) |
160 (6-5/16) |
265 (10-7/16) |
76 (3) |
62 (2-7/16) |
5.5 (7/32) |
| C30…C43 | 300 (11-13/16) |
300 (11-13/16) |
160 (6-5/16) |
236 (9-5/16) |
178 (7) |
61 (2-13/32) |
5.5 (7/32) |
| C60…C72 | 350 (13-25/32) |
400 (15-3/4) |
210 (8-9/32) |
315 (12-13/32) |
178 (7) |
111 (4-3/8) |
5.5 (7/32) |
| C85 | 610 (24) |
406 (16) |
230 (9-1/16) |
572 (22-1/2) |
368 (14-1/2) |
19 (3/4) |
11 (7/16) |
Bulletins 105 and 120E Metal Hinged Enclosures Type 3/4/12 (IP66)
|
| Contactor Size | A Height | B Width | C Depth | D | E (Mtg.) | F | G (dia) |
| IP66 (Type 3/4/12) Metal Hinged Enclosure for Bulletins 105 and 120E (Without Transformer) | |||||||
| C09…C23 | 250 (9-13/16) |
250 (9-13/16) |
160 (6-5/16) |
186 (7-5/16) |
76 (3) |
87 (3-13/32) |
5.5 (7/32) |
| C30…C43 | 300 (11-13/16) |
300 (11-13/16) |
160 (6-5/16) |
236 (9-5/16) |
178 (7) |
61 (2-13/32) |
5.5 (7/32) |
| C60…C72 | 350 (13/25/32) |
400 (15-3/4) |
210 (8-9/32) |
315 (12-13/32) |
178 (7) |
111 (4-3/8) |
5.5 (7/32) |
| C85 | 610 (24) |
406 (16) |
230 (9-1/06) |
572 (22-1/2) |
368 (14-1/2) |
19 (3/4) |
11 (7/16) |
| IP66 (Type 3/4/12) Metal Hinged Enclosure for Bulletins 105 and 120E (With Transformer) | |||||||
| C09…C23 | 300 (11-13/16) |
300 (11-13/16) |
160 (6-5/16) |
236 (9-5/16) |
178 (7) |
61 (2-13/32) |
5.5 (7/32) |
| C30…C43 | 350 (13-25/32) |
400 (15-3/4) |
210 (8-9/32) |
315 (12-13/32) |
178 (7) |
111 (4-3/8) |
5.5 (7/32) |
| C60…C72 | 610 (24) |
406 (16) |
230 (9-1/06) |
572 (22-1/2) |
368 (14-1/2) |
19 (3/4) |
11 (7/16) |
| C85 | 762 (30) |
610 (24) |
281 (11-1/16) |
724 (28-1/2) |
572 (22-1/2) |
19 (3/4) |
11 (7/16) |
Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.
Bulletins 132 and 133 Metal Hinged Enclosures with Extra Space Type 3R (IP32)
|
| Contactor Size | A Height | B Width | C Depth | D | E | F | G | H | J | K |
| IP 32 (Type 3R) Rainproof Metal Hinged Enclosure for Bulletins 132 and 133 (With and Without Transformer) | ||||||||||
| C09…C43 | 584 (23) |
320 (12-19/32) |
187 (7-5/16) |
711 (28) |
105 (4-1/8) |
108 (4-1/4) |
679 (26-3/4) |
667 (26-1/4) |
105 (4-1/8) |
105 (4-1/8) |
| C60…C72 | 864 (34) |
447 (17-19/32) |
238 (9-5/16) |
991 (39) |
105 (4-1/8) |
171 (6-3/4) |
959 (37-3/4) |
946 (37-1/4) |
105 (4-1/8) |
169 (6-12/32) |
| B110 | 1067 (42) |
762 (30) |
305 (12) |
1118 (44) |
686 (27) |
38 (1-1/2) |
1092 (43) |
1092 (43) |
— | — |
| B180…B250 | 1219 (48) |
914 (36) |
305 (12) |
1270 (50) |
686 (27) |
114 (4-1/2) |
1245 (49) |
1245 (49) |
— | — |