Enclosed Starters

Catalogs > Industrial Controls Catalog > Motor Control, IEC > Enclosed Starters > Bulletin 109-C IEC Non-Reversing Starters

Bulletin 109-C IEC Non-Reversing Starters

Introduction Standards Compliance and Certifications Catalog Number Explanation Product Selection Bulletin 100 Line Starter Accessories Modifications Bul. 100 Line Starters Approximate Dimensions
Catalog Number Explanation

Examples given in this section are for reference purposes. This basic explanation should not be used for product selection; not all combinations will produce a valid cat. no. Refer to the tables on the following pages for descriptions of options.

IEC Non-Reversing Starters in Plastic Enclosures

109 CA    K    D    2 E1P 4G 7
a    b    c    d    e    f    g    g

a    b    c    d
Bulletin No. Contactor Size Enclosure Coil Voltage Code — AC Voltage
Code Description Code Description Code Description Code Description
109 IEC Non-reversing starter CA 100-C09 K Plastic Encl. PC, IP66, Type 12K/4/4X Q 12V, 60 Hz
  CB 100-C12   R 12V, 50 Hz
CC 100-C16 J 24V, 60 Hz
CD 100-C23 K 24V, 50 Hz
  KJ 24V, 50/60 Hz
V 32V, 50 Hz / 36V, 60 Hz
W 36V, 50 Hz
X 42V, 50 Hz / 48V, 60 Hz
Y 48V, 50 Hz
KY 48V, 50/60 Hz
KP 100V, 50 Hz / 100...110V, 60 Hz
D 110V, 50 Hz / 120V, 60 Hz
KD 110V, 50/60 Hz
P 120V, 50 Hz
S 127V, 50 Hz
KG 200V, 50 Hz / 200…220V, 60 Hz
KL 200…230V, 50/60 Hz
L 208...240V, 60 Hz
F 220...230V, 50 Hz
KF 230V, 50/60 Hz
A 240V, 60 Hz
T 240V, 50 Hz / 277V, 60 Hz
E 380V, 60 Hz
N 380...400V, 50 Hz / 440V, 60 Hz
KN 400V, 50/60 Hz
G 400...415V, 50 Hz
KB 440V, 50/60 Hz
B 440V, 50 Hz / 480V, 60 Hz
M 500V, 50 Hz
C 550V, 50/60 Hz0V, 60 Hz
      
e    f    g     
Auxiliary Contacts Overload Relay Modifications and Accessories
Code Description 193-ED/ -EE 3-phase Electronic Overload Relay Code Description
0 N.O. Aux.Contact used in Start/Stop Circuit Code Description R Surge Suppressor RC
2 N.O. for Customer Use with Reset Option only D1_ Cl.10, Man. Reset (add additional code suffix below) V Surge Suppressor Varistor
  E1_ Aut./Man.Reset, Adj. Class (add additional code suffix below) 2 Push Buttons, START/ raised STOP/RESET (green/red)
Adj. Range/Contactor Size 7 Push Button, RESET (blue)
Code Description MC With Pushbutton Latch for Maintained Control
_A 0.1…0.5 A, 100-C09…C23 Pilot Lights IP66, Type 4/4X/12K
_B 0.2…1.0 A, 100-C09…C23 Code Description
_C 1.0…5.0 A, 100-C09…C23 4G Pilot Light "RUN", Green
_D 3.2…16 A, 100-C09…C23 4R Pilot Light "RUN", Red
_E 5.4…27 A, 100-C16…C23 4Y Pilot Light "Failure", Yellow
193-EE Single-phase Electron. Overload Relay  
Code Description
E1P 1.0...5.0 A, 100-C09…C23
E1R 3.2...16 A, 100-C09…C23
E1S 5.4…27 A, 100-C16…C23