Bulletin 109-C IEC Non-Reversing Starters

Introduction Standards Compliance and Certifications Catalog Number Explanation Product Selection Bulletin 100 Line Starter Accessories Modifications Bul. 100 Line Starters Approximate Dimensions
Product Selection

Product Selection — AC-Operated Starters

Standard Enclosed Type — Sheet Metal

Ratings (AC3, AC4) IP42 (Type 1)
General Purpose
Sheet Metal Enclosure (Liftoff Cover)
IP66 (Type 3, 4, 12)
Watertight, Dusttight
Sheet Metal Enclosure
(Hinged Cover)
Max Ie
[A]
kW Hp
3-Phase 1-Phase 3-Phase Cat. No. Cat. No.
380V/415V 115V 230V 200V 230V 460V 575V
9 4 1/2 1-1/2 2 2 5 7-1/2 109-C09Aĵ 109-C09Fĵ
12 5-1/2 1/2 2 3 3 7-1/2 10 109-C12Aĵ 109-C12Fĵ
16 7-1/2 1 3 5 5 10 15 109-C16Aĵ 109-C16Fĵ
23 11 2 3 5 7-1/2 15 15 109-C23Aĵ 109-C23Fĵ
30 15 2 5 7-1/2 10 20 25 109-C30Aĵ 109-C30Fĵ
37 18-1/2 3 5 10 10 25 30 109-C37Aĵ 109-C37Fĵ
43 22 3 7-1/2 10 15 30 30 109-C43Aĵ 109-C43Fĵ
60 30 5 10 15 20 40 50 109-C60Aĵ 109-C60Fĵ
72 37 5 15 20 25 50 60 109-C72Aĵ 109-C72Fĵ
85 45 7-1/2 15 25 30 60 60 109-C85Aĵ 109-C85Fĵ
  

Ä Coil Voltage Code

The Cat. No. as listed is incomplete. Select a Coil Voltage Code from the table below to complete the Cat. No. Example: Cat. No. 109-C09Aĵ becomes Cat. No.109-C09ABµ.

AC Voltage [V] 24 48 110 120 208 208…240 220 240 277 380…400 400…415 440 480 500 600
Common Control§ 
Coil Voltage Code
50 Hz A T N G B M
60 Hz H L A N B C
Separate Control (without transformer)
Coil Voltage Code
50 Hz K Y D
60 Hz J X D T
  

µ Overload Relay Code

The Cat. No. as listed is incomplete. Select an overload relay code from Bulletin 193 E1 Plus electronic overload relay for 3-phase applications:
Selectable Trip Class 10, 15, 20, 30, selectable manual/auto reset
to complete the Cat. No. Select an overload relay code from E1 Plus Overload Relay for 3Æ Applications: Phase Loss Protection, Class 10 or 20 to complete the Cat. No. Bimetal overload relays are not available in molded plastic enclosed starters.


§ When selecting a factory-installed control circuit transformer (see Full Voltage Non-Reversing Starters and Lighting Contactors (Bulletins 109 with metal enclosures, 100L)), use the Common Control Coil Voltage Code to denote the transformer primary voltage. The starter coil and transformer secondary voltage will both be 120V by default. Example: Cat. No. 109-C09FBµ-6P will have a transformer with a 480V primary/120V secondary and a 120V starter coil. If a starter coil voltage other than 120V is desired, a second Coil Voltage Code must be added to denote the coil/transformer secondary voltage. Example: Cat. No. 109-C09FBJµ-6P will have a transformer with a 480V primary/24V secondary and a 24V starter coil. Control Circuit transformers are not available in molded plastic enclosures