Enclosed Starters

Catalogs > Industrial Controls Catalog > Motor Control, IEC > Enclosed Starters > Bulletin 113-C IEC Combination Starters

Bulletin 113-C IEC Combination Starters

Introduction Standards Compliance and Certifications Product Selection Bulletin 100 Line Starter Accessories Modifications Bul. 100 Line Starters Approximate Dimensions
Product Selection

Circuit Breaker Type - AC Operated

Ratings (AC3, AC4) IP42 (Type 1)
General Purpose
Sheet Metal Enclosure
(Hinged Cover)
IP66 (Type 3/4/12)
Watertight, Dusttight
Sheet Metal Enclosure
(Hinged Cover)
Max Ie
[A]
Hp¬ 
3Æ Cat. No.¬  Cat. No.¬ 
200V 230V 460V 575V
30 1/2 1/2 113-C30Aĵ-33 113-C30Fĵ-33
3/4…1 3/4…1 1/2…1 113-C30Aĵ-35 113-C30Fĵ-35
1/2…1-1/2 113-C30Aĵ-36 113-C30Fĵ-36
1-1/2…3 1-1/2…3 1-1/2…3 2…3 113-C30Aĵ-38 113-C30Fĵ-38
5 113-C30Aĵ-39 113-C30Fĵ-39
7-1/2 5…7-1/2 5…7-1/2 113-C30Aĵ-40 113-C30Fĵ-40
10 5…10 113-C30Aĵ-41 113-C30Fĵ-41
10 113-C30Aĵ-42 113-C30Fĵ-42
20 15…20 113-C30Aĵ-43 113-C30Fĵ-43
25 113-C30Aĵ-44 113-C30Fĵ-44
43 7-1/2…10 10 113-C43Aĵ-41 113-C43Fĵ-41
15 113-C43Aĵ-42 113-C43Fĵ-42
20…25 113-C43Aĵ-44 113-C43Fĵ-44
30 25…30 113-C43Aĵ-45 113-C43Fĵ-45
60 15 113-C60Aĵ-42 113-C60Fĵ-42
15…20 113-C60Aĵ-43 113-C60Fĵ-43
40 40 113-C60Aĵ-46 113-C60Fĵ-46
72 15…20 113-C72Aĵ-43 113-C72Fĵ-43
20…25 113-C72Aĵ-44 113-C72Fĵ-44
40…50 113-C72Aĵ-47 113-C72Fĵ-47
40…60 113-C72Aĵ-48 113-C72Fĵ-48
  

Ä Coil Voltage Code

The Cat. No. as listed is incomplete. Select a Coil Voltage Code from the table below to complete the Cat. No. Example:
Cat. No. 113-C30Aĵ-33 becomes Cat. No. 113-C30ABµ-33.


Voltage [V] 208 230…240 460…480 575…600
Common ControlT 
Coil Voltage Code
60 Hz H A B C
120V — Separate Control (without transformer)
Coil Voltage Code
HD AD BD CD
  

µ Overload Relay Code

The Cat. No. as listed is incomplete. Select an overload relay code from Bulletin 193 E1 Plus electronic overload relay for 3-phase applications:
Selectable Trip Class 10, 15, 20, 30, selectable manual/auto reset
to complete the Cat. No.


¬ For design “E” motor applications, consult your local Rockwell Automation sales office or Allen-Bradley distributor.
T When selecting a factory-installed control circuit transformer (see Modifications Full Voltage Non-Reversing Starters and Lighting Contactors (Bulletins 109, 100L)), use the Common Control Coil Voltage Code to denote the transformer primary voltage. The starter coil and transformer secondary voltage will both be 120V by default. Example: Cat. No. 113-C30FB3µ-6P will have a transformer with a 480V primary/120V secondary and a 120V starter coil. If a starter coil voltage other than 120V is desired, a second Coil Voltage Code must be added to denote the coil/transformer secondary voltage. Example: Cat. No. 113-C30FBJµ-6P will have a transformer with a 480V primary/24V secondary and a 24V starter coil.