Enclosed Starters

Catalogs > Industrial Controls Catalog > Motor Control, IEC > Enclosed Starters > Bulletin 112-C IEC Combination Starters

Bulletin 112-C IEC Combination Starters

Introduction Standards Compliance and Certifications Product Selection Bulletin 100 Line Starter Accessories Modifications Bul. 100 Line Starters Approximate Dimensions
Product Selection

Product Selection — AC-Operated Starters

Fusible Disconnect Type

Ratings (AC3, AC4) IP42 (Type 1) General Purpose Sheet Metal Enclosure (Hinged Cover) IP66 (Type 3/4/12) Watertight, Dusttight Sheet Metal Enclosure (Hinged Cover)
Max Ie
[A]
Hp Fuse Clip Rating
Amperes/ UL Class
3-Phase Cat. No. Cat. No.
200V 230V 460V 575V
9 2 2 5 7-1/2 30 A/Class CC 112-C09Aĵ 112-C09Fĵ
12 3 3 7-1/2 10 30 A/Class J 112-C12Aĵ 112-C12Fĵ
23 5 7-1/2 15 15 30 A/Class J 112-C23Aĵ 112-C23Fĵ
30 7-1/2 10 20 25 60 A/Class J 112-C30Aĵ 112-C30Fĵ
43 10 15 30 30 60 A/Class J 112-C43Aĵ 112-C43Fĵ
60 15 20 40 50 100 A/Class J ‡  112-C60Aĵ ‡  112-C60Fĵ
72 20 25 50 60 100 A/Class J ‡  112-C72Aĵ ‡  112-C72Fĵ
  

Non-Fusible Disconnect Type

Ratings (AC3, AC4) IP42 (Type 1) General Purpose Sheet Metal Enclosure (Hinged Cover) IP66 (Type 3/4/12) Watertight, Dusttight Sheet Metal Enclosure (Hinged Cover)
Max Ie
[A]
Hp
3-Phase Cat. No. Cat. No.
200V 230V 460V 575V
9 2 2 5 7-1/2 112-C09Aĵ-DNF 112-C09Fĵ-DNF
12 3 3 7-1/2 10 112-C12Aĵ-DNF 112-C12Fĵ-DNF
23 5 7-1/2 15 15 112-C23Aĵ-DNF 112-C23Fĵ-DNF
30 7-1/2 10 20 25 112-C30Aĵ-DNF 112-C30Fĵ-DNF
43 10 15 30 30 112-C43Aĵ-DNF 112-C43Fĵ-DNF
60 15 20 40 50 ‡  112-C60Aĵ-DNF ‡  112-C60Fĵ-DNF
72 20 25 50 60 ‡  112-C72Aĵ-DNF ‡  112-C72Fĵ-DNF
  

Ä Coil Voltage Code

The Cat. No. as listed is incomplete. Select a Coil Voltage Code from the table below to complete the Cat. No. Example: Cat. No. 112-C09Aĵ becomes Cat. No. 112-C09ABµ.

Voltage [V] 208 230…240 460…480 575…600
Common Control⋆ 
Coil Voltage Code
60 Hz H A B C
120V — Separate Control (without transformer)
Coil Voltage Code
HD AD BD CD
  

µ Overload Relay Code

The Cat. No. as listed is incomplete. Select an overload relay code from Bulletin 193 E1 Plus electronic overload relay for 3-phase applications:
Selectable Trip Class 10, 15, 20, 30, selectable manual/auto reset
to complete the Cat. No.


⋆ When selecting a factory-installed control circuit transformer (see Modifications Full Voltage Non-Reversing Starters and Lighting Contactors (Bulletins 109 with metal enclosures, 100L)), use the Common Control Coil Voltage Code to denote the transformer primary voltage. The starter coil and transformer secondary voltage will both be 120V by default. Example: Cat. No. 112-C09FB-µ-6P will have a transformer with a 480V primary/120V secondary and a 120V starter coil. If a starter coil voltage other than 120V is desired, a second Coil Voltage Code must be added to denote the coil/transformer secondary voltage. Example: Cat. No. 112-C09FBJ-µ-6P will have a transformer with a 480V primary/24V secondary and a 24V starter coil.
‡ The Bul. 193-TI bi-metallic overload relays are not available for this product selection.