Catalogs > Industrial Controls Catalog > Motor Control, IEC > Enclosed Starters > Bulletin 105-C IEC Reversing Starters
Bulletin 105-C IEC Reversing Starters
| Introduction | Standards Compliance and Certifications | Product Selection | Bulletin 100 Line Starter Accessories | Modifications | Bul. 100 Line Starters Approximate Dimensions |
Product Selection
AC-Operated
| Ratings (AC3, AC4) | IP42 (Type 1) General Purpose Sheet Metal Enclosure (Lift-off cover through 105-C72) |
IP66 (Type 3/4/12) Watertight, Dusttight Sheet Metal Enclosure (Hinged Cover) |
|||||||
| Max Ie [A] |
kW | Hp | |||||||
| 3Æ | 1Æ ¬ | 3Æ | Cat. No. | Cat. No. | |||||
| 380V/ 415V |
115V | 230V | 200V | 230V | 460V | 575V | |||
| 9 | 4 | 1/2 | 1-1/2 | 2 | 2 | 5 | 7-1/2 | 105-C09Aĵ | 105-C09Fĵ |
| 12 | 5-1/2 | 1/2 | 2 | 3 | 3 | 7-1/2 | 10 | 105-C12Aĵ | 105-C12Fĵ |
| 16 | 7-1/2 | 1 | 3 | 5 | 5 | 10 | 15 | 105-C16Aĵ | 105-C16Fĵ |
| 23 | 11 | 2 | 3 | 5 | 7-1/2 | 15 | 15 | 105-C23Aĵ | 105-C23Fĵ |
| 30 | 15 | 2 | 5 | 7-1/2 | 10 | 20 | 25 | 105-C30Aĵ | 105-C30Fĵ |
| 37 | 18-1/2 | 3 | 5 | 10 | 10 | 25 | 30 | 105-C37Aĵ | 105-C37Fĵ |
| 43 | 22 | 3 | 7-1/2 | 10 | 15 | 30 | 30 | 105-C43Aĵ | 105-C43Fĵ |
| 60 | 30 | 5 | 10 | 15 | 20 | 40 | 50 | 105-C60Aĵ | 105-C60Fĵ |
| 72 | 37 | 5 | 15 | 20 | 25 | 50 | 60 | 105-C72Aĵ | 105-C72Fĵ |
| 85 | 45 | 7-1/2 | 15 | 25 | 30 | 60 | 60 | 105-C85Aĵ | 105-C85Fĵ |
Ä Coil Voltage Code
The Cat. No. as listed is incomplete. Select a Coil Voltage Code from the table below to complete the Cat. No. Example:
Cat. No. 105-C09Aĵ becomes Cat. No. 105-C09ABµ.
| AC Voltage | 24 | 48 | 110 | 120 | 208 | 208… 240 |
220 | 240 | 277 | 380… 400 |
400… 415 |
440 | 480 | 500 | 600 | |
| Common ControlT Coil Voltage Code |
50 Hz | — | — | — | — | — | — | A | T | — | N | G | B | — | M | — |
| 60Hz | — | — | — | — | H | L | — | A | — | — | — | N | B | — | C | |
| Separate Control (without transformer) Coil Voltage Code |
50 Hz | K | Y | D | — | — | — | — | — | — | — | — | — | — | — | — |
| 60Hz | J | X | — | D | — | — | — | — | T | — | — | — | — | — | — | |
µ Overload Relay Code
The Cat. No. as listed is incomplete. Select an overload relay code from Bulletin 193 E1 Plus electronic overload relay for 3-phase applications:
Selectable Trip Class 10, 15, 20, 30, selectable manual/auto reset to complete the Cat. No.
¬ For single-phase (1Æ) applications, consult your local Rockwell Automation sales office or Allen-Bradley distributor.
T When selecting a factory-installed control circuit transformer (see Modifications Full Voltage Non-Reversing Starters and Lighting Contactors (Bulletins 109, 100L)), use the Common Control Coil Voltage Code to denote the transformer primary voltage. The starter coil and transformer secondary voltage will both be 120V by default. Example: Cat. No. 105-C09FBµ-6P will have a transformer with a 480V primary/120V secondary and a 120V starter coil. If a starter coil voltage other than 120V is desired, a second Coil Voltage Code must be added to denote the coil/transformer secondary voltage. Example: Cat. No. 105-C09FBJµ-6P will have a transformer with a 480V primary/24V secondary and a 24V starter coil.
