Bulletin 106-C IEC Reversing Combination Starters Fusible Disconnect Type

Click to enlarge - 106-263-1


Click to enlarge - 106-263-2
Cat. No. 106-C30FBA1H-4RW-6PIP66 (Type 3,4,12)Metal Enclosure with Hinged Cover


Bulletin 106 IEC Reversing Combination Starters


Bulletin 106 Combination starters use a Bulletin 104 reversing contactor, a Bulletin 193 bimetallic (Class 10) or solid-state overload relay, and a Bulletin 194R rotary disconnect switch. Reversing starters (9 A…72 A) incorporate a “dual” interlock that provides both mechanical and electrical interlocking in a single unit. A normally open auxiliary contact is also included on each contactor.

Standards Compliance and Certifications

Standards Compliance

EN/IEC 60947-4-1
VDE 0660
CSA C22.2 No. 14
UL 508


Certifications

cULus Listed (File E3125, Guide NLDX, NLDX7)

Product Selection

Your order must include: Cat. No. of the reversing combination starter selected, coil voltage code, overload relay suffix code, and, if required, factory-installed modifications suffix code and/or Cat. No. of any accessories.

Fusible Disconnect Type
AC Operated


Ratings (AC3, AC4) IP42 (Type 1)
General-Purpose
Sheet Metal Enclosure
(Hinged Cover)
IP66 (Type 3, 4, 12)
Watertight, Dusttight
Sheet Metal Enclosure
(Hinged Cover)
Max Ie
[A]
kW Hp Fuse Clip Rating
Amperes/UL Class
3Æ 3Æ Cat. No. Cat. No.
380…415V 200V 230V 460V 575V
9 4 2 2 5 7-1/2 30 A/Class CC 106-C09Aĵ 106-C09Fĵ
12 5-1/2 3 3 7-1/2 10 30 A/Class J 106-C12Aĵ 106-C12Fĵ
23 11 5 7-1/2 15 15 30 A/Class J 106-C23Aĵ 106-C23Fĵ
30 15 7-1/2 10 20 25 60 A/Class J 106-C30Aĵ 106-C30Fĵ
43 22 10 15 30 30 60 A/Class J 106-C43Aĵ 106-C43Fĵ
60 30 15 20 40 50 100 A/Class J 106-C60Aĵ 106-C60Fĵ
72 37 20 25 50 60 100 A/Class J 106-C72Aĵ 106-C72Fĵ
  

Ä Coil Voltage Code

    The Cat. No. as listed is incomplete. Select a Coil Voltage Code from the table below to complete the Cat. No. Example:
Cat. No. 106-C09Aĵ becomes Cat. No. 106-C09ABµ.


Voltage 208V 230…240V 460…480V 575…600V
Common Control ¬  Coil Voltage Code 60 Hz H A B C
120V — Separate Control (without transformer)
Coil Voltage Code
AD AD CD CD
  

µ Overload Relay Code

    The Cat. No. as listed is incomplete. Select an overload relay code from Bulletin 193 E1 Plus electronic overload relay for 3-phase applications:
Selectable Trip Class 10, 15, 20, 30, selectable manual/auto reset
to complete the Cat. No.


¬ When selecting a factory-installed control circuit transformer (see Modifications Full Voltage Non-Reversing Starters and Lighting Contactors (Bulletins 109, 100L)), use the Common Control Coil Voltage Code to denote the transformer primary voltage. The starter coil and transformer secondary voltage will both be 120V by default. Example: Cat. No. 106-C09FBµ-6P will have a transformer with a 480V primary/120V secondary and a 120V starter coil. If a starter coil voltage other than 120V is desired, a second Coil Voltage Code must be added to denote the coil/transformer secondary voltage. Example: Cat. No. 106-C09FBJµ-6P will have a transformer with a 480V primary/24V secondary and a 24V starter coil.


Bulletin 100 Line Starter Accessories

For Bulletins 105, 106, 109, 112, 113, 120E, 132, and 133

Click to enlarge - 800F_N6R Description For Use With Enclosure Type Cat. No.
Red "ON" Pilot Light¬ 
Full Voltage Type
120V All Metal Lift-off, Metal Hinged, and Molded Plastic T  198-PL21R
208V T  198-PL25R
240V T  198-PL22R
Click to enlarge - 800F_N6R Dual "ON" Pilot Light¬ 
Forward — Red
Reverse — White
Full Voltage Type
120V 105, 106 Metal Hinged 198-PL21RW
240V 198-PL22RW
Click to enlarge - 100_Line-267-4 Pilot Device Mounting Bracket
(required when mounting pilot devices in metal lift-off enclosures)
105, 109, 120E Metal Lift-off 198-BR1
Click to enlarge - 100_Line-267-5 Control Circuit Transformer
With Top-Mounted Fuse Block
All Metal Lift-off and Metal Hinged    
Click to enlarge - 100_Line-267-6 Control Circuit Fuse Block
For Class CC rejection type fuses (fuses not included)
All Metal Lift-off and Metal Hinged 1491-R162
Click to enlarge - 100_Line-267-7 Grounding Bushing
Adapts to 1/2 in. N.P.T., PG 16.5 & BS20 mm threads
109 Molded Plastic 198-GR1
Click to enlarge - 100_Line-267-8 Single Pole N.O. Auxiliary Contact for Disconnect Switch 106, 112 Metal Hinged ‡  195-GA10
Click to enlarge - 100_Line-267-9 Fuse Cover for Disconnect Switch 106,112,132-C09…C23 Metal Hinged 194R-FCA2
106,112,132-C30…C43 194R-FCJ60
106,112,132-C60…C72 §  194R-FCC1
Click to enlarge - 100_Line-267-10 Closing Button
For 22.5mm Round Panel Hole
All All 198-N1
Click to enlarge - Push_Button_right "OFF-ON" Selector Switch
2-Position Maintained
All Metal Lift-off and Metal Hinged T  198-MT3
  
¬ Does not include legend plate. See Two-Color Molded Legend Caps — Non-Illuminated Push Buttons for Bulletin 800F Legend Plate. Legend Plates for use on metal-hinged enclosures only.
T Requires mounting bracket Cat. No. 198-BR1 when using metal lift-off enclosures.
‡ An auxiliary contact adaptor, Cat. No. 194R-AA, is required when installing auxiliary contact, Cat. No. 195-GA10.
§ 3 required for disconnect switch.

For Bulletins 105, 106, 109, 112, 113, 120E, 132, and 133

Click to enlarge - 198_MT1 Description For Use With Enclosure Type Cat. No.
"HAND-OFF-AUTO" Selector Switch
3-Position Maintained, Includes Legend Plate
All Metal Lift-off and Metal Hinged ¬  198-MT1
"FORWARD-OFF-REVERSE" Selector Switch
3-Position Maintained
105, 106 Metal Lift-off and Metal Hinged ¬  198-MT2
Click to enlarge - 198_MS3 "START-STOP" Push Button
Flush green "I/START"
Extended red "O/STOP"
105, 109, 120E Metal Lift-off ¬  198-MS3
Click to enlarge - 198_MS13 "START" Push Button
Flush green "START"
All Metal Hinged 198-MS13
Click to enlarge - 198_MS6 "ON-OFF" Push Button 105, 109, 120E Metal Lift-off ¬  198-MS6
Click to enlarge - 198_MS7 "FORWARD, REVERSE-STOP" Push Button 105 Metal Lift-off ¬  198-MS7
  
¬ Requires mounting bracket Cat. No. 198-BR1 when using metal lift-off enclosures.

For Bulletins 105, 106, 109, 112, 113, 120E, 132, and 133

Click to enlarge - 198_MS8 Description For Use With Enclosure Type Cat. No.
"HIGH, LOW-STOP" Push Button 120E Metal Lift-off ¬  198-MS8
Click to enlarge - 198_MS8 "FAST, SLOW-STOP" Push Button 120E Metal Lift-off ¬  198-MS9
Click to enlarge - 198_MS14 "STOP" Push Button
Extended red "STOP"
All Metal Hinged 198-MS14
Click to enlarge - 198_MS15 "ON" Push Button
Flush green "ON"
All Metal Hinged 198-MS15
Click to enlarge - 198_MS16 "OFF" Push Button
Extended red "OFF"
All Metal Hinged 198-MS16
Click to enlarge - 198_MS17 "FORWARD, REVERSE-STOP"
Push Buttons
105, 106 Metal Hinged 198-MS17
Click to enlarge - 198_MS18 "HIGH, LOW-STOP"
Push Buttons
120E Metal Hinged 198-MS18
Click to enlarge - 100_Line-269-8 "RESET" Push Button All Metal Hinged 198-MR6
Click to enlarge - 100_Line-269-10 "RESET" Push Button 105, 109, 120E Metal Lift-off and Metal Hinged 198-MR3
  
¬ Requires mounting bracket Cat. No. 198-BR1 when using metal lift-off enclosures.

Modifications

Full Voltage Non-Reversing Starters and Lighting Contactors (Bulletins 109, 100L)

Listed on this and the following pages are factory-installed modifications and special features which are available for the low voltage (600V maximum) starters listed in this catalog. To order, add a dash followed by the suffix number listed in these tables to the end of the product Cat. No. Example: Cat. No. 109-C09ADA1E-1

Description of Modification Suffix Code Enclosure Design C09/CA C12/CB C16/CC 100L-C20 C23/CD C30 C37 C43 C60 C72 C85
START-STOP Push Button 1 Metal Lift-off A A A NA A A A A A A A
Metal Hinged A A A NA A A A A A A A
ON-OFF Push Button 1E Metal Lift-off A A A A A A A A A A A
Metal Hinged A A A A A A A A A A A
HAND-OFF-AUTO Selector Switch 3 Metal Lift-off A A A A A A A A A A A
Metal Hinged A A A A A A A A A A A
OFF-ON Selector Switch 3E Metal Lift-off A A A A A A A A A A A
Metal Hinged A A A A A A A A A A A
RUN-Red Pilot Light¬  4R Plastic Lift-off A A A NA A A A A A A A
RUN-Green Pilot Light¬  4G A A A NA A A A A A A A
RUN-Yellow Pilot Light¬  4Y A A A NA A A A A A A A
Red LED Pilot Light (120V) 4R1 Plastic Lift-off A A A NA A NA NA NA NA NA NA
Red LED Pilot Light (240V) 4R2 Plastic Lift-off A A A NA A NA NA NA NA NA NA
Control Circuit Transformer 2 Primary and 1 Secondary Fuse Provided (Standard Capacity) 6PT  Metal Lift-off A A A A A A A A A A A
Metal Hinged A A A A A A A A A A A
External Reset 7 Plastic Lift-off A A A NA A NA NA NA NA NA NA
Metal Lift-off A A A NA A A A A A A A
Metal Hinged A A A NA A A A A A A A
Control Circuit Fuse Block 2 Fuses Provided 22 Metal Lift-off A A A A A A A A A A A
Metal Hinged A A A A A A A A A A A
Additional 1 N.O. – 1 N.C. (Side Mount) Auxiliary Contact on Contactor (100L only) 90 Metal Lift-off NA NA NA A NA NA NA NA NA NA NA
Metal Hinged NA NA NA A NA NA NA NA NA NA NA
Additional 1 N.O. – 1 N.C. (Side Mount) Auxiliary Contact on Contactor 901 Metal Lift-off A A A A A A A A A A A
Metal Hinged A A A A A A A A A A A
Additional 1 N.O. – 1 N.C. (Front Mount) Auxiliary Contact on Contactor 901T Metal Lift-off A A A A A A A A A A A
Metal Hinged A A A A A A A A A A A
  
¬ With Bulletin 800F Integrated LED Module. Pilot light is available for control voltages of 240Vor less. If applicable, seelct a transformer. For starters with molded plastic lift-off enclosures, the voltage of the LED module must equal the starter's coil voltage.

Non-Reversing Circuit Breaker Combination Starters (Bulletin 113, 133)

Description of Modification Suffix
Code
Enclosure
Design
C09 C12 C16 C23 C30 C37 C43 C60 C72 C85
START-STOP Push Button (113 Only) 1 ALL NA NA NA NA A NA A A A NA
HAND-OFF-AUTO (113 Only) 3 ALL NA NA NA NA A NA A A A NA
Red Pilot Light¬  4R ALL NA NA NA NA A NA A A A NA
Control Circuit Transformer 2 Primary and 1 Secondary Fuse Provided (Standard Capacity) 6PT  ALL NA NA NA NA A NA A A A NA
External Reset 7 ALL NA NA NA NA A NA A A A NA
Control Circuit Fuse Block 2 Fuses Provided 22 ALL NA NA NA NA A NA A A A NA
Additional 1 N.O. - 1 N.C. (Side Mount) Auxiliary Contact on Contactor 901 ALL NA NA NA NA A NA A A A NA
Additional 1 N.O. - 1 N.C. (Front Mount) Auxiliary Contact on Contactor 901T ALL NA NA NA NA A NA A A A NA
  
A=Available Option
NA=Not Available
¬ Transformer Type.
T When ordering in Canada, use suffix 6. Primary fusing is not required by the Canadian Electrical Code.

Full Voltage Reversing and Multi-Speed Starters (Bulletins 105, 120E)

Description of Modification Suffix
Code
Enclosure Design C09 C12 C16 C23 C30 C37 C43 C60 C72 C85
FOR-REV-STOP Push Buttons (105 Only) 1 Metal Lift-off A A A A A A A A A NA
Metal Hinged A A A A A A A A A A
HIGH-LOW-STOP Push Buttons (120E Only) 1 Metal Lift-off A A A A A A A A A NA
Metal Hinged A A A A A A A A A A
FOR-OFF-REV Selector Switch (105 Only) 3 Metal Lift-off A A A A A A A A A NA
Metal Hinged A A A A A A A A A A
HIGH-OFF-LOW Selector Switch (120E Only) 3 Metal Lift-off A A A A A A A A A NA
Metal Hinged A A A A A A A A A A
Red FOR/ White REV Pilot Lights¬  (105 Only) 4RW Metal Hinged A A A A A A A A A A
A A A A A A A A A A
Red HIGH/White LOW Pilot Lights¬  (120E Only) 4RW Metal Hinged A A A A A A A A A A
A A A A A A A A A A
Control Circuit Transformer 2 Primary and 1 Secondary Fuse Provided (Standard Capacity) 6PT  ALL A A A A A A A A A A
1 External Reset (105 Only) 7 ALL A A A A A A A A A A
2 External Resets (120E Only) 7 ALL A A A A A A A A A A
Control Circuit Fuse Block 2 Fuses Provided 22 ALL A A A A A A A A A A
Additional 1 N.O. – 1 N.C. (Side Mount) Auxiliary Contact on Each Contactor 901 ALL A A A A A A A A A A
Additional 1 N.O. – 1 N.C. (Front Mount) Auxiliary Contact on Each Contactor 901T ALL A A A A A A A A A A
  

Reversing and Non-Reversing Fusible Combination Starters (Bulletins 106, 112, 132)

Description of Modification Suffix
Code
Enclosure
Design
C09 C12 C16 C23 C30 C37 C43 C60 C72 C85
START-STOP Push Button (112 Only) 1 ALL A A NA A A NA A A A NA
FOR-REV-STOP Push Buttons (106 Only) 1 ALL A A NA A A NA A A A NA
HAND-OFF-AUTO Selector Switch (112 Only) 3 ALL A A NA A A NA A A A NA
FOR-REV-STOP Selector Switch (106 Only) 3 ALL A A NA A A NA A A A NA
Red Pilot Light¬  4R ALL A A NA A A NA A A A NA
Red FOR/ White REV Pilot Lights¬  (106 Only) 4RW ALL A A NA A A NA A A A NA
Control Circuit Transformer 2 Primary and 1 Secondary Fuse Provided (Standard Capacity) 6PT  ALL A A NA A A NA A A A NA
External Reset 7 ALL A A NA A A NA A A A NA
Fuse Cover For Disconnect Switch 8 ALL A A NA A A NA A A A NA
Control Circuit Fuse Block 2 Fuses Provided 22 ALL A A NA A A NA A A A NA
N.O. Auxiliary Contact On Disconnect Switch 98 ALL A A NA A A NA A A A NA
Additional 1 N.O. – 1 N.C. (Side Mount) Auxiliary Contact on Contactor (112 and 132 Only) 901 ALL A A NA A A NA A A A NA
Additional 1 N.O. – 1 N.C. (Side Mount) Auxiliary Contact on each Contactor (106 Only) 901 ALL A A NA A A NA A A A NA
Additional 1 N.O. – 1 N.C. (Front Mount) Auxiliary Contact on Contactor (112 and 132 Only) 901T ALL A A NA A A NA A A A NA
Additional 1 N.O. – 1 N.C. (Front Mount) Auxiliary Contact on each Contactor (106 Only) 901T ALL A A NA A A NA A A A NA
  
A=Available Option
NA=Not Available
¬ Transformer Type.
T When ordering in Canada, use suffix 6. Primary fusing is not required by the Canadian Electrical Code.

Bul. 100 Line Starters Approximate Dimensions

Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.

Bulletin 109 Plastic Lift-Off Enclosure

Click to enlarge - 109_plastic_dim


Bulletin 109 Metal Lift-Off Enclosures Type 1 (IP42)

Click to enlarge - 100_Line-273-3


Contactor Size A Height B Width C Depth D E F
IP42 (Type 1) General Purpose Metal Lift-Off Enclosure for Bulletin 109 (Without Transformer)
C09…C23 315
(12-27/64)
188
(7-23/64)
203
(8)
270
(10-5/8)
140
(5-33/64)
24
(15/16)
C30…C43
C60…C72 305
(12)
178
(7)
203
(8)
270
(10-5/8)
140
(5-33/64)
24
(15/16)
C85 585
(23-1/32)
257
(10-7/64)
203
(8)
540
(21-17/64)
210
(8-17/64)
23.5
(59/64)
IP42 (Type 1) General Purpose Metal Lift-Off Enclosure for Bulletin 109 (With Transformer)
C09…C23 305
(12)
178
(7)
203
(8)
245
(9-41/64)
140
(5-33/64)
24
(15/16)
C30…C43 290
(11-27/64)
270
(10-5/8)
152
(5-31/32)
245
(9-41/64)
225
(8-55/64)
22.5
(57/64)
C60…C72 315
(12-27/64)
325
(12-51/64)
203
(8)
270
(10-5/8)
280
(11-1/64)
22.5
(57/64)
C85 585
(23-1/32)
257
(10-7/64)
203
(8)
540
(21-17/64)
210
(8-17/64)
23.5
(59/64)
  

Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.

Bulletins 105 and 120E Metal Lift-Off Enclosures Type 1 (IP42)

Click to enlarge - 100_Line-274-1
Metal Lift-Off


Contactor Size A Height B Width C Depth D E F G (dia)
IP42 (Type 1) General Purpose Metal Lift-off Enclosure for Bulletin 105 and 120E (Without Transformer)
C09…C23 220
(8-21/32)
235
(9-1/4)
152
(5-31/32)
175
(6-57/64)
190
(7-31/64)
22.5
(57/64)
C30…C43 290
(11-27/64)
270
(10-5/8)
152
(5-31/32)
245
(9-41/32)
225
(8-55/64)
22.5
(57/64)
C60…C72 315
(12-27/64)
325
(12-51/64)
203
(8)
270
(10-5/8)
280
(11-1/64)
22.5
(57/64)
C85 610
(24)
406
(16)
230
(9-1/16)
572
(22-1/2)
368
(14-1/2)
19
(3/4)
11
(7-16)
IP42 (Type 1) General Purpose Metal Lift-Off Enclosure for Bulletin 105 and 120E (With Transformer)
C09…C23 290
(11-27/64)
270
(10-5/8)
152
(5-31/32)
245
(9-41/64)
225
(8-55/64)
22.5
(57/64)
C30…C43 315
(12-27/64)
325
(12-51/64)
203
(8)
270
(10-5/8)
280
(11-1/64)
22.5
(57/64)
  

Bulletins 106, 112, and 113 Metal Hinged Enclosures Type 1 (IP42), Type 3/4/12 (IP66)

Click to enlarge - 100_Line-274-2


Contactor Size A Height B Width C Depth D E F G (dia)
IP42 (Type 1) and IP66 (Type 3/4/12) General Purpose Metal Hinged Enclosure for Bulletin 106 (With and Without Transformer)
C30…C43 350
(13-25/32)
400
(15-3/4)
200
(7-7/8)
315
(12-13/32)
178
(7)
62
(2-7/16)
6.4
(1/4)
C60…C72 610
(24)
406
(16)
224
(8-13/16)
572
(22-1/2)
368
(14-1/2)
19
(3/4)
12.7
(1/2)
IP42 (Type 1) and IP66 (Type 3/4/12) General Purpose Metal Hinged Enclosure for Bulletin 112 (With and Without Transformer)
C09…C23 350
(13-25/32)
200
(7-7/8)
200
(7-7/8)
315
(12-13/32)
76
(3)
62
(2-7/16)
6.4
(1/4)
C30…C43 350
(13-25/32)
400
(15-3/4)
200
(7-7/8)
315
(12-13/32)
178
(7)
111
(4-3/8)
6.4
(1/4)
C60…C72 610
(24)
406
(16)
224
(8-13/16)
572
(22-1/2)
368
(14-1/2)
19
(3/4)
12.7
(1/2)
IP42 (Type 1) and IP66 (Type 3/4/12) General Purpose Metal Hinged Enclosure for Bulletin 113 (With and Without Transformer)
C30…C72 610
(24)
406
(16)
224
(8-13/16)
572
(22-1/2)
368
(14-1/2)
19
(3/4)
12.7
(1/2)
  

Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.

Bulletin 109 Metal Hinged Enclosures Type 3/4/12 (IP66)

Click to enlarge - 100_Line-275-1


Contactor Size A Height B Width C Depth D E F G (dia)
IP66 (Type 3/4/12) Metal Hinged Enclosure for Bulletin 109 (Without Transformer)
C09…C43 300
(11-13/16)
200
(7-7/8)
160
(6-5/16)
265
(10-7/16)
76
(3)
62
(2-7/16)
5.5
(7/32)
C60…C72 350
(13/25/32)
200
(7-7/8)
210
(8-9/32)
315
(12-13/32)
76
(3)
62
(2-7/16)
5.5
(7/32)
C85 762
(30)
305
(12)
276
(10-7/8)
724
(28-1/2)
267
(10-1/2)
19
(3/4)
11
(7/16)
IP66 (Type 3/4/12) Metal Hinged Enclosure for Bulletin 109 (With Transformer)
C09…C23 300
(11-13/16)
200
(7-7/8)
160
(6-5/16)
265
(10-7/16)
76
(3)
62
(2-7/16)
5.5
(7/32)
C30…C43 300
(11-13/16)
300
(11-13/16)
160
(6-5/16)
236
(9-5/16)
178
(7)
61
(2-13/32)
5.5
(7/32)
C60…C72 350
(13-25/32)
400
(15-3/4)
210
(8-9/32)
315
(12-13/32)
178
(7)
111
(4-3/8)
5.5
(7/32)
C85 610
(24)
406
(16)
230
(9-1/16)
572
(22-1/2)
368
(14-1/2)
19
(3/4)
11
(7/16)
  

Bulletins 105 and 120E Metal Hinged Enclosures Type 3/4/12 (IP66)

Click to enlarge - 100_Line-275-2


Contactor Size A Height B Width C Depth D E (Mtg.) F G (dia)
IP66 (Type 3/4/12) Metal Hinged Enclosure for Bulletins 105 and 120E (Without Transformer)
C09…C23 250
(9-13/16)
250
(9-13/16)
160
(6-5/16)
186
(7-5/16)
76
(3)
87
(3-13/32)
5.5
(7/32)
C30…C43 300
(11-13/16)
300
(11-13/16)
160
(6-5/16)
236
(9-5/16)
178
(7)
61
(2-13/32)
5.5
(7/32)
C60…C72 350
(13/25/32)
400
(15-3/4)
210
(8-9/32)
315
(12-13/32)
178
(7)
111
(4-3/8)
5.5
(7/32)
C85 610
(24)
406
(16)
230
(9-1/06)
572
(22-1/2)
368
(14-1/2)
19
(3/4)
11
(7/16)
IP66 (Type 3/4/12) Metal Hinged Enclosure for Bulletins 105 and 120E (With Transformer)
C09…C23 300
(11-13/16)
300
(11-13/16)
160
(6-5/16)
236
(9-5/16)
178
(7)
61
(2-13/32)
5.5
(7/32)
C30…C43 350
(13-25/32)
400
(15-3/4)
210
(8-9/32)
315
(12-13/32)
178
(7)
111
(4-3/8)
5.5
(7/32)
C60…C72 610
(24)
406
(16)
230
(9-1/06)
572
(22-1/2)
368
(14-1/2)
19
(3/4)
11
(7/16)
C85 762
(30)
610
(24)
281
(11-1/16)
724
(28-1/2)
572
(22-1/2)
19
(3/4)
11
(7/16)
  

Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.

Bulletins 132 and 133 Metal Hinged Enclosures with Extra Space Type 3R (IP32)

Click to enlarge - 198_d


Contactor Size A Height B Width C Depth D E F G H J K
IP 32 (Type 3R) Rainproof Metal Hinged Enclosure for Bulletins 132 and 133 (With and Without Transformer)
C09…C43 584
(23)
320
(12-19/32)
187
(7-5/16)
711
(28)
105
(4-1/8)
108
(4-1/4)
679
(26-3/4)
667
(26-1/4)
105
(4-1/8)
105
(4-1/8)
C60…C72 864
(34)
447
(17-19/32)
238
(9-5/16)
991
(39)
105
(4-1/8)
171
(6-3/4)
959
(37-3/4)
946
(37-1/4)
105
(4-1/8)
169
(6-12/32)
B110 1067
(42)
762
(30)
305
(12)
1118
(44)
686
(27)
38
(1-1/2)
1092
(43)
1092
(43)
B180…B250 1219
(48)
914
(36)
305
(12)
1270
(50)
686
(27)
114
(4-1/2)
1245
(49)
1245
(49)