Catalogs > Industrial Controls Catalog > Motor Control, IEC > Overload Relays > Bulletin 193 E1 Plus Solid-State Overload Relays
Bulletin 193 E1 Plus Solid-State Overload Relays
| Introduction | Standards Compliance and Certifications | Product Overview | Catalog Number Explanation |
| Product Selection | Accessories | Specifications | Approximate Dimensions |
Bulletin 193-ED Three-Phase Devices
- Fixed Trip Class 10
- Manual reset
- Screw-type control terminals
| Mounts to Contactor | Adjustment Range [A] | Cat. No. |
| 100-C09…100-C23 | 0.1…0.5 | 193-ED1AB |
| 0.2…1.0 | 193-ED1BB | |
| 1.0…5.0 | 193-ED1CB | |
| 3.2…16 | 193-ED1DB | |
| 5.4…27 | 193-ED1EB | |
| 100-C30…100-C43 | 5.4…27 | 193-ED1ED |
| 9…45 | 193-ED1FD | |
| Integrated panel/DIN Rail mount and pass-thru wiring | 1.0…5.0 | 193-ED1CP |
| 3.2…16 | 193-ED1DP | |
| 5.4…27 | 193-ED1EP | |
Bulletin 193-EE Three-Phase Devices
- Selectable Trip Class (10, 15, 20, 30)
- Selectable manual/auto-manual reset
- Screw-type control terminals
| Mounts to Contactor | Adjustment Range [A] | Cat. No. | |
| 100-C09…100-C23 | 0.1…0.5 | | 193-EEAB |
| 0.2…1.0 | | 193-EEBB | |
| 1.0…5.0 | | 193-EECB | |
| 3.2…16 | | 193-EEDB | |
| 5.4…27 | | 193-EEEB | |
| 100-C30…100-C43 | 5.4…27 | | 193-EEED |
| 9…45 | | 193-EEFD | |
| 100-C60…100-C85 | 18…90 | | 193-EEGE |
| 100-D95…100-D180 | 18…90 | T | 193-EEGF |
| 30…150 | T | 193-EEHF | |
| 40…200 | T | 193-EEJF | |
| 55…110 | T | 193-EEVF | |
| 100-D210…100-D420 | 40…200 | T | 193-EEJG |
| 60…300 | T | 193-EEKG | |
| 100…500 | T | 193-EELG | |
| 100-D630…100-D860 | 120…600 | T | 193-EEMH |
| 160…800 | T | 193-EENH | |
| Integrated panel/DIN Rail mount and pass-thru wiring | 1.0…5.0 | | 193-EECP |
| 3.2…16 | | 193-EEDP | |
| 5.4…27 | | 193-EEEP | |
| Package Quantity = 1 | |||
| Spring Clamp Control Terminals To order, change the Bulletin number in the listed cat. no. from 193 to 193R (Example: Cat. No. 193-EEFD becomes Cat. No. 193R-EEFD). | |||
| T Does not include terminal lugs. See Accessories. | |||
Bulletin 193S-EE Single-Phase Devices
- Selectable Trip Class (10, 15, 20, 30)
- Selectable manual/auto-manual reset
- Screw-type control terminals
| Mounts to Contactor | Adjustment Range [A] | Cat. No. |
| 100-C09…100-C23 | 1.0…5.0 | 193S-EEPB |
| 3.2…16 | 193S-EERB | |
| 5.4…27 | 193S-EESB | |
| 100-C30…100-C43 | 9…45 | 193S-EETD |
| 100-C60…100-C85 | 18…90 | 193S-EEUE |
| Integrated panel/DIN Rail mount and pass-thru wiring | 1.0…5.0 | 193S-EEPP |
| 3.2…16 | 193S-EERP | |
| 5.4…27 | 193S-EESP | |
Bulletin 193 Panel Mount Devices for use with External Current Transformers § §
- Selectable Trip Class (10, 15, 20, 30)
- Selectable manual/auto-manual reset
| CT Ratio | Adjustment Range [A] | Cat. No. |
| 150:5 | 30…150 | 193-EEHZ |
| 200:5 | 40…200 | 193-EEJZ |
| 300:5 | 60…300 | 193-EEKZ |
| 400:5 | 80…400 | 193-EEWZ |
| 500:5 | 100…500 | 193-EELZ |
| 600:5 | 120…600 | 193-EEMZ |
| 800:5 | 160…800 | 193-EENZ |
§ Current Transformers supplied by customer, refer to Specifications for proper current transformer selection.
§ Order panel adapter, Cat. No. 193-EPB, separately.