Overload Relays

Catalogs > Industrial Controls Catalog > Motor Control, IEC > Overload Relays > Bulletin 193 E1 Plus Solid-State Overload Relays

Bulletin 193 E1 Plus Solid-State Overload Relays

Introduction Standards Compliance and Certifications Product Overview Catalog Number Explanation Product Selection
Side-Mount Expansion Modules⋆  Accessories Specifications Approximate Dimensions
Side-Mount Expansion Modules⋆ 

Function E1 Plus§ 
(Cat. No. 193/592-EE_)
E1 Plus w/ Jam Module
(Cat. No. 193-EJM)
E1 Plus w/ Ground Fault Module⋆ 
(Cat. No. 193-EGF)
E1 Plus w/ Ground Fault/Jam Module⋆ 
(Cat. No. 193-EGJ)
E1 Plus w/ PTC Module
(Cat. No. 193-EPT)
E1 Plus w/ Remote Reset Module
(Cat. No. 193-ERR)
E1 Plus w/ DeviceNet Module
(Cat. No. 193-EDN)
E1 Plus w/ EtherNet/IP Module
(Cat. No. 193-ETN)
E1 Plus w/ Profibus Module
(Cat. No. 193-EPRB)
Manual/Automatic Reset X X X X X X X X X
Selectable Trip Class 10 X X X X X X X X
15 X X X X X X X X
20 X X X X X X X X
30 X X X X X X X X
Jam Protection On or Off X X X X X
Trip Level Adjustable 150/200/300/400% Fixed @ 400% Adjustable 150…600% FLA Adjustable 150…600% FLA Adjustable 150…600% FLA
Trip Delay Adjustable 0.5/1.0/2.0/4.0 s Fixed @ 0.5 s Adjustable 0.5…25 s Adjustable 0.5…25 s Adjustable 0.5…25 s
Inhibit Dynamic Inhibit§  Dynamic Inhibit§  Dynamic Inhibit§  Dynamic Inhibit§  Dynamic Inhibit§ 
Ground Fault Protection Type Core-Balanced Ground Fault Protection⋆  Core-Balanced Ground Fault Protection⋆ 
On or Off X X
Trip Level Adjustable 20 mA…5 A&  Adjustable 20 mA…5 A& 
Trip Delay Fixed @
50 ms ± 20 ms
Fixed @
50 ms ± 20 ms
Inhibit Dynamic Inhibit§  Dynamic Inhibit§ 
PTC Protection PTC Overtemperature Trip X
PTC Open Circuit X
PTC Short Circuit X
Remote Reset Capability X X X X X X X X
Fault Indication X X X X X X
  
§ Dynamic Inhibit: Protective function is enabled after the motor current goes above 150% and then falls to below 125%.
⋆ Requires use of an external ground fault sensor, Cat. No. 193-CBCT_.
& From 20…100 mA for resistive loads only.

  Description For Use With Pkg. Quantity Cat. No.
Click to enlarge - devicenet_193EDN_cmyk E1 Plus DeviceNet and Protection Module
Communicates motor diagnostic data via DeviceNet, includes additional I/O, and provides enhanced motor protection options.⋆ 
193-EE (all),
592-EE (all),
193S-EE (all),
592S-EE (all)
1 193-EDN
Click to enlarge - 193_ETN_A_right E1 Plus EtherNet/IP and Protection Module
Communicates motor diagnostic data via EtherNet/IP, includes additional I/O, and provides enhanced motor protection options.⋆ 
193-EE (all),
592-EE (all),
193S-EE (all),
592S-EE (all)
1 193-ETN
Click to enlarge - 193-EPRB_right_4c E1 Plus PROFIBUS and Protection Module
Communicates motor diagnostic data via PROFIBUS, includes additional I/O, and provides enhanced motor protection options.⋆ 
193-EE (all),
592-EE (all),
193S-EE (all),
592S-EE (all)
1 193-EPRB
Click to enlarge - Jam r-17387_nosrcew E1 Plus Jam Protection Module
Provides Jam protection with adjustable trip level and trip delay setting. The module also provides an input to allow remote reset of a trip.⋆ 
193-EE (all),
592-EE (all),
193S-EE (all),
592S-EE (all)
1 193-EJM
Click to enlarge - 193_EGF_right E1 Plus Ground Fault Module
Provides adjustable 20 mA…5 A ground fault protection. The module also provides an input to allow remote reset of a trip.⋆ 
193-EE (all), 592-EE (all), 193S-EE (all), 592S-EE (all) 1 §  193-EGF
Click to enlarge - 193_EGJ_right E1 Plus Ground Fault/Jam Module
Provides adjustable 20 mA…5 A ground fault and fixed jam protection. The module also provides an input to allow remote reset of a trip.⋆ 
193-EE (all), 592-EE (all), 193S-EE (all), 592S-EE (all) 1 §  193-EGJ
Click to enlarge - 193_EPT_right E1 Plus PTC Module
Provides terminals for connection up to six PTC thermistor sensors. Sensors react to actual temperature and therefore provide enhanced motor protection. Module also provides an input to allow remote reset of a trip.⋆ 
193-EE (all),
592-EE (all),
193S-EE (all),
592S-EE (all)
1 193-EPT
Click to enlarge - 193_ERR_right E1 Plus Remote Reset Module
Provides an input to allow remote reset of a trip.⋆ 
193-EE (all),
592-EE (all),
193S-EE (all),
592S-EE (all)
1 193-ERR
Click to enlarge - 193_ERID_AB_right E1 Plus Remote Indicator Display
Displays the status of an E1 Plus from the front of a panel and features a reset button. Mounts in a standard 22 mm push button cutout.⋆ 
193-EGF,
193-EJM,
193-EGJ,
193-PTC,
193-ERR (Ser. B or later)
1 193-ERID
  Module Adjustment Cover
Prevents inadvertent adjustment of setting. Must be ordered in multiples of package quantity.
193-EJM 25 193-EMC
  
⋆ Only one module may be added.
§ Requires use of an external ground fault sensor (Cat. No. 193-CBCT_).