| Description
|
Connection Diagram T
|
For Use With
|
Cat. No.
|
|
|
Operator Position ¬
|
Term. No.
|
Description
|
| OFF
|
ON
|
Tripped
|
|
|
|
|
Front-Mounted Auxiliary Contact 1-pole or 2-pole No additional space required -One only per MPCB
|
O
|
X
|
O
|
13-14
|
N.O. Aux
|
|
140M-C, D, F
|
140M-C-AFA10
|
| X
|
O
|
X
|
11-12
|
N.C. Aux
|
|
140M-C, D, F
|
140M-C-AFA01
|
|
O
|
X
|
O
|
13-14
|
N.O. Aux
|
|
140M-C, D, F
|
140M-C-AFA11
|
| X
|
O
|
X
|
21-22
|
N.C. Aux
|
| O
|
X
|
O
|
13-14
|
N.O. Aux
|
|
140M-C, D, F
|
140M-C-AFA20
|
| O
|
X
|
O
|
23-24
|
N.O. Aux
|
| X
|
O
|
X
|
11-12
|
N.C. Aux
|
|
140M-C, D, F
|
140M-C-AFA02
|
| X
|
O
|
X
|
21-22
|
N.C. Aux
|
|
Right Side-Mounted Auxiliary Contact 2-pole Adds 9 mm to the width of the device -Two per MPCB
|
O
|
X
|
O
|
33-34
|
N.O. Aux
|
|
140M-C, D, F
|
140M-C-ASA20
|
| O
|
X
|
O
|
43-44
|
N.O. Aux
|
| X
|
O
|
X
|
31-32
|
N.C. Aux
|
|
140M-C, D, F
|
140M-C-ASA02
|
| X
|
O
|
X
|
41-42
|
N.C. Aux
|
| O
|
X
|
O
|
33-34
|
N.O. Aux
|
|
140M-C, D, F
|
140M-C-ASA11
|
| X
|
O
|
X
|
41-42
|
N.C. Aux
|
|
|
| ¬ X = Contact Closed; O = Contact Open
|
| T
|
|
| Description
|
Connection Diagram T
|
|
|
For Use With
|
Cat. No.
|
|
|
Operator Position ¬
|
Term. No.
|
Description
|
| OFF
|
ON
|
Tripped
|
|
|
|
N.O.
|
N.C.
|
|
Front-Mounted Trip Contact 2-pole Indicates tripping of device No additional space required
|
O
|
X
|
O
|
13-14
|
N.O. Aux
|
|
2
|
0
|
140M-C, D, F
|
140M-C-AFAR10A10
|
| O
|
O
|
X
|
27-28
|
N.O. Trip (Short-Circuit & Overload)
|
| X
|
O
|
X
|
11-12
|
N.C. Aux
|
|
1
|
1
|
140M-C, D, F
|
140M-C-AFAR10A01
|
| O
|
O
|
X
|
27-28
|
N.O. Trip (Short-Circuit & Overload)
|
|
Right-Side Mounted Trip Contact 2-pole Indicates tripping of Motor Protection Circuit Breaker Adds 9 mm to the width of the circuit breaker -One only per MPCB -A right-side mounted auxiliary contact may be tandem mounted on top of this Trip Contact
|
O
|
O
|
X
|
57-58
|
N.O. Trip (Short-Circuit & Overload)
|
|
2
|
0
|
140M-C, D, F
|
140M-C-ASAR10M10
|
| O
|
O
|
X
|
67-68
|
N.O. Trip (Short-Circuit)
|
| O
|
O
|
X
|
57-58
|
N.O. Trip (Short-Circuit & Overload)
|
|
1
|
1
|
140M-C, D, F
|
140M-C-ASAR10M01
|
| X
|
X
|
O
|
65-66
|
N.C. Trip (Short-Circuit)
|
| X
|
X
|
O
|
55-56
|
N.C. Trip (Short-Circuit & Overload)
|
|
1
|
1
|
140M-C, D, F
|
140M-C-ASAR01M10
|
| O
|
O
|
X
|
67-68
|
N.O. Trip (Short-Circuit)
|
| X
|
X
|
O
|
55-56
|
N.C. Trip (Short-Circuit & Overload)
|
|
0
|
2
|
140M-C, D, F
|
140M-C-ASAR01M01
|
| X
|
X
|
O
|
65-66
|
N.C. Trip (Short-Circuit)
|
| O
|
O
|
X
|
77-78
|
N.O. Trip (Short-Circuit)
|
|
1
|
1
|
140M-C, D, F
|
140M-C-ASAM11
|
| X
|
X
|
O
|
65-66
|
N.C. Trip (Short-Circuit)
|
|
|
| ¬ X = Contact Closed; O = Contact Open
|
| T
|
|
| Description
|
Connection DiagramT
|
|
|
For Use With
|
Cat. No.
|
|
|
Operator Position¬
|
Term. No.
|
Description
|
| OFF
|
ON
|
Tripped
|
|
|
|
N.O.
|
N.C.
|
|
Front-Mounted Auxiliary Contact Internal 2-pole -One per MPCB
|
O
|
X
|
O
|
13-14
|
N.O. Aux
|
|
2
|
0
|
140-CMN
|
140-CA20
|
| O
|
X
|
O
|
23-24
|
N.O. Aux
|
| X
|
O
|
X
|
11-12
|
N.C. Aux
|
|
0
|
2
|
140-CMN
|
140-CA02
|
| X
|
O
|
X
|
21-22
|
N.C. Aux
|
| O
|
X
|
O
|
13-14
|
N.O. Aux
|
|
1
|
1
|
140-CMN
|
140-CA11
|
| X
|
O
|
X
|
21-22
|
N.C. Aux
|
|
Front-Mounted Trip-Indicating Auxiliary Contact Internal 2-pole -One per MPCB
|
O
|
O
|
X
|
37-38
|
N.O. Trip (Overload)
|
|
2
|
0
|
140-CMN
|
140-CT10-10
|
| O
|
O
|
X
|
43-44
|
N.O. Trip (Short-Circuit)
|
| X
|
X
|
O
|
35-36
|
N.C. Trip (Overload)
|
|
0
|
2
|
140-CMN
|
140-CT01-01
|
| X
|
X
|
O
|
41-42
|
N.C. Trip (Short-Circuit)
|
| X
|
X
|
O
|
35-36
|
N.C. Trip (Overload)
|
|
1
|
1
|
140-CMN
|
140-CT01-10
|
| O
|
O
|
X
|
43-44
|
N.O. Trip (Short-Circuit)
|
| O
|
O
|
X
|
37-38
|
N.O. Trip (Overload)
|
|
1
|
1
|
140-CMN
|
140-CT10-01
|
| X
|
X
|
O
|
41-42
|
N.C. Trip (Short-Circuit)
|
|
|
¬ X = Contact Closed O = Contact Open
|
| T
|
|
| Description
|
Connection Diagram¬
|
Trip Rating
|
For Use With
|
Cat. No.
|
|
Undervoltage Trip Left-side mounted Adds 18 mm to the width of the circuit breaker Automatically trips MPCB/MCP when voltage falls below 35…70%
|
|
24V, 60 Hz
|
140M-C, D, F
|
140M-C-UXJ
|
| 24V, 50 Hz
|
140M-C-UXK
|
| 120V, 60 Hz
|
140M-C-UXD
|
| 110V, 50 Hz
|
140M-C-UXC
|
| 208V, 60 Hz
|
140M-C-UXH
|
| 220…230V, 50 Hz
|
140M-C-UXF
|
| 240…260V, 60 Hz
|
140M-C-UXA
|
| 277V, 60 Hz
|
140M-C-UXT
|
| 380…400V, 50 Hz
|
140M-C-UXN
|
| 480V, 60 Hz/415V, 50 Hz
|
140M-C-UXB
|
| 575V, 60 Hz/500V, 50 Hz
|
140M-C-UXM
|
| 600V, 60 Hz
|
140M-C-UXVC
|
Undervoltage Trip Left-side mounted 2 early make contacts integrated Adds 18 mm to the width of the circuit breaker Automatically trips MPCB/MCP when voltage falls below 35…70%
|
|
24V, 60 Hz
|
140M-C, D, F
|
140M-C-UCJ
|
| 24V, 50 Hz
|
140M-C-UCK
|
| 120V, 60 Hz
|
140M-C-UCD
|
| 110V, 50 Hz
|
140M-C-UCC
|
| 208V, 60 Hz
|
140M-C-UCH
|
| 220…230V, 50 Hz
|
140M-C-UCF
|
| 240…260V, 60 Hz
|
140M-C-UCA
|
| 277V, 60 Hz
|
140M-C-UCT
|
| 380…400V, 50 Hz
|
140M-C-UCN
|
| 480V, 60 Hz/415V, 50 Hz
|
140M-C-UCB
|
| 575V, 60 Hz/500V, 50 Hz
|
140M-C-UCM
|
| 600V, 60 Hz
|
140M-C-UCVC
|
Shunt Trip Left-side mounted Adds 18 mm to the width of the circuit breaker Provides remote tripping of the MPCB/MCP
|
|
24V, 60 Hz
|
140M-C, D, F
|
140M-C-SNJ
|
| 24V, 50 Hz
|
140M-C-SNK
|
| 110V, 50 Hz/120V, 60 Hz
|
140M-C-SND
|
| 208V, 60 Hz
|
140M-C-SNH
|
| 220…230V, 50 Hz
|
140M-C-SNF
|
| 240…260V, 60 Hz
|
140M-C-SNA
|
| 277V, 60 Hz
|
140M-C-SNT
|
| 380…400V, 50 Hz
|
140M-C-SNN
|
| 480V, 60 Hz/415V, 50 Hz
|
140M-C-SNB
|
| 575V, 60 Hz/500V, 50 Hz
|
140M-C-SNM
|
| 600V, 60 Hz
|
140M-C-SNVC
|
| 24V DC
|
140M-C-SNZJ
|
|
Undervoltage Trip Unit Internal, front-mounted Integrated short-circuit trip indication Automatically trips MPCB when voltage falls below 35…70%
|
|
24V, 50/60 Hz
|
140-CMN
|
140-CUV-KJ
|
| 110V, 50 Hz/120V, 60 Hz
|
140-CUV-D
|
| 220V, 50 Hz/240V, 60 Hz
|
140-CUV-A
|
|
Shunt Trip Unit Internal, front-mounted Integrated short-circuit trip indication Provides remote tripping of the MPCB
|
|
24V, 50/60 Hz
|
140-CMN
|
140-CRT-KJ
|
| 110V, 50 Hz/120V, 60 Hz
|
140-CRT-D
|
| 220V, 50 Hz/240V, 60 Hz
|
140-CRT-A
|
|
|
| ¬
|
|
Package Quantity = 1 Discount Group = MAC
|
| Description
|
For Use With
|
PQ
|
Cat. No.
|
|
Anti-Tamper Shield Provides protection against inadvertent adjustment of the current setting
|
10 pcs/pkg
|
140M-C, D, F
|
10
|
140M-C-CA
|
|
Lockable Twist Knob For one padlock 4…6 mm (1/4 in.) dia. shackle Can be locked in OFF position
|
Black
|
140M-C, D, F
|
1
|
140M-C-KN
|
| Red/Yellow
|
140M-C/-D
|
1
|
140M-C-KRY
|
| Red/Yellow
|
140M-F
|
1
|
140M-F-KRY
|
|
Padlockable Operating Knob Accepts 8 mm (5/16 in.) dia. padlock — up to three padlocks Permits padlocking in the off position
|
Black
|
140-CMN
|
1
|
140-KN
|
| Red/Yellow
|
1
|
140-KRY
|
|
Door Coupling Handle For three padlocks 4…8 mm (5/16 in.) dia. IP66 Protection/Type 1, 4, 4X, 12 Interlock override capability Can be modified for locking in ON position Ships with coupling — order extension shaft and legend plate separately Mounting depth (front of DIN Rail to front of enclosure door): 140M-C: 105.5 mm ± 5 mm (4.15 in. ± 3/16 in.) 140M-D: 114.5 mm ± 5 mm (4.5 in. ± 3/16 in.) 140M-F: 137.1 mm ± 5 mm (5.4 in. ± 3/16 in.) 140-CMN: 169 mm +/- 5 mm (6.7 in. +/- 3/16 in.)
|
Black
|
140M-C, D, F
|
1
|
140M-C-DN66
|
| 140-CMN
|
1
|
140-CDN66
|
|
Red/Yellow
|
140M-C, D, F
|
1
|
140M-C-DRY66
|
| 140-CMN
|
1
|
140-CDRY66
|
|
Extension Shaft Cut to required length for mounting depth (front of DIN Rail to front of enclosure door): 140M-C: 117…338 mm (4.6.…13.3 in.) 140M-D: 126…347 mm (5.0.…13.7 in.) 140M-F: 149…369 mm (5.9.…14.5 in.) 140-CMN: 180…403 mm (7.1.…15.9 in.)
|
140M-C-DN66, 140M-C-DRY66, 140-CDN66, 140-CDRY66
|
1
|
140M-C-DS
|
Extension Shaft (Extended Length) Cut to required length for mounting depth (front of DIN Rail to front of enclosure door): 140M-C: 117…488 mm (4.6…19.2 in.) 140M-D: 126…497 mm (5.0…19.6 in.) 140M-F: 149…519 mm (5.9…20.4 in.) 140-CMN: 180…553 mm (7.1…21.8 in.)
|
140M-C-DN66, 140M-C-DRY66, 140-CDN66, 140-CDRY66
|
1
|
140M-C-DSL
|
|
Coupler Included with Cat. Nos. 140M-C-DN66 and 140M-C-DRY66
|
140M-C, D, F
|
1
|
140M-C-DNC
|
|
Legend Plate Marking: "Hauptschalter" and "Main Switch" Marking: "Not-Aus" and "Emergency Off"
|
140-CDN66
|
1
|
140M-C-DFCN
|
| 140-CDRY66
|
1
|
140M-C-DFCRY
|
|
Locking Tag Padlock attachment to the lockable handles Up to three padlocks 4…8 mm (5/16 in.) dia. shackle
|
140M-C-KN 140M-C-KRY 140M-F-KRY
|
1
|
140M-C-M3
|
|
IP65 Non-Metallic Enclosure Knockouts for M20 and M25 fittings Suitable for flexible cable with internal ground wire or conduit when externally grounded around the outside of the enclosure (no UL approval)
|
Black Handle
|
140M-C
|
1
|
198E-AYTG2
|
| Red/Yellow Handle
|
140M-C
|
1
|
198E-AYTJ2
|
|
Terminal Cover For covering of unused commoning link terminals IP2X finger protection
|
140M-C, 140M-D
|
1
|
140M-C-WS
|
| 140M-F
|
1
|
140M-F-WS
|
|
Screw Adapter For screw arrangement of a Motor Protection Circuit Breaker
|
10 pcs/pkg
|
140M-C, D, F
|
10
|
140M-C-N45
|
|
|
PQ = Package Quantity Discount Group = MAC
|
| Description
|
For Use With
|
Cat. No.
|
|
ECO Connecting Module — 12 and 25 A For DOL and reversing starters Eco-starters mount on single DIN Rail (140M on DIN Rail) Electrical and mechanical interconnection of 140M MPCB and 100-K contactors
|
140M-C to 100-K
|
140M-C-PEK12
|
ECO Connecting Modules — 25 A Eco-starters mount on single DIN Rail (140M on DIN Rail) Electrical and mechanical interconnection of 140M MPCB and 100-C (with AC coils or 24V DC electronic coils) contactors
|
140M-C to 100-C09…C23
|
140M-C-PEC23
|
| 140M-D to 100-C09…C23
|
140M-D-PEC23
|
Connecting Modules — 25 and 45 A Contactor and MPCB MUST BE mounted separately on (2) DIN Rails Electrical interconnection between 140M MPCB and 100-C contactors (with AC coils)
|
140M-C to 100-C09…C23
|
140M-C-PNC23
|
| 140M-D to 100-C09…C23
|
140M-D-PNC23
|
| 140M-D to 100-C30…C37
|
140M-D-PNC37
|
| 140M-F to 100-C30…C37
|
140M-F-PNC37
|
| 140M-F to 100-C43
|
140M-F-PNC43
|
Coil Modules — 25 A and 45 A For use with Bulletin 103T/107T 3-component starters
|
140M-C, -D to 100-C09…C23
|
140M-C-PSC23
|
| 140M-D, -F to 100-C30…C43
|
140M-F-PSC43
|
|
Spacing Adapter Required for Self-Protected combination motor controller (Type E) applications of Bul. 140M-C, -D, and -F MPCBs
|
140M-C, -D
|
140M-C-TE1
|
| 140M-F
|
140M-F-TE
|
|
Compact Busbar Feeder Block Supply of compact busbars Increases terminal capacity
|
140M-C, -D
|
140M-C-WBE
|
| 140M-F
|
140M-F-WBE
|
|
Compact Busbar Feeder Terminal For supply of commoning links Top feed — overlaps commoning link Meets UL Type E spacing requirements
|
140M-C, -D
|
140M-C-WTE
|
| 140M-F
|
140M-F-WTE
|
|
Three-Phase Compact Busbar for 25 A Motor Protection Circuit Breakers — 63 A Max. Continuous Current 45 mm spacing For use with front-mounted auxiliary contact
|
2 connections
|
140M-C, -D
|
140M-C-W452
|
| 3 connections
|
140M-C-W453
|
| 4 connections
|
140M-C-W454
|
| 5 connections
|
140M-C-W455
|
Three-Phase Compact Busbar for 25 A Motor Protection Circuit Breakers — 63 A Max. Continuous Current 54 mm spacing For use with side-mounted auxiliary contact
|
2 connections
|
140M-C, -D
|
140M-C-W542
|
| 3 connections
|
140M-C-W543
|
| 4 connections
|
140M-C-W544
|
| 5 connections
|
140M-C-W545
|
Three-Phase Compact Busbar for 25 A Motor Protection Circuit Breakers — 63 A Max. Continuous Current 63 mm spacing For use with side-mounted undervoltage trip and shunt trip
|
2 connections
|
140M-C, -D
|
140M-C-W632
|
| 3 connections
|
140M-C-W633
|
| 4 connections
|
140M-C-W634
|
| 5 connections
|
140M-C-W635
|
|
Jumper for 140M-D to 140M-C Accommodates difference in depth from Bul. 140M-D to 140M-C 54 mm spacing Can be used with all other commoning links
|
2 connections
|
140M-D to 140M-C
|
140M-C-WD542
|
|
Three-Phase Compact Busbar for 45 A Motor Protection Circuit Breakers — 115 A Max. Continuous Current 54 mm spacing For use with front-mounted auxiliary contact
|
2 connections
|
140M-F
|
140M-F-W542
|
| 3 connections
|
140M-F-W543
|
| 4 connections
|
140M-F-W544
|
Three-Phase Compact Busbar for 45 A Motor Protection Circuit Breakers — 115 A Max. Continuous Current 63 mm spacing For use with side-mounted auxiliary contact
|
2 connections
|
140M-F
|
140M-F-W632
|
| 3 connections
|
140M-F-W633
|
| 4 connections
|
140M-F-W634
|
|
DIN (#3) Symmetrical Rail 35 x 7.5 x 1 m
|
10 pcs/kg
|
140M-D 140M-F
|
199-DR1
|
|
DIN (#3) Symmetrical Rail 35 mm x 15 mm x 1 m long Top Hat Rail (DIN #3 Symmetrical Rail)
|
5 pcs/kg
|
140M-C 140M-D 140M-F 140-CMN
|
1492-DR9
|
|
|
| Description
|
For Use With
|
Pkg. Quantity
|
Cat. No.
|
|
Terminal End Cover — 0.25 in.
|
140M-I
|
1
|
140U-I-TC2
|
| Terminal End Cover — 0.41 in.
|
140U-I-TC4
|
|
Terminal Shields (Plastic) IP20 Ingress Protection
|
140M-I
|
1
|
140U-I-TS1
|
|
Padlockable Handle Lock Hasp — Off only Padlocking Hasp Lock-OFF only
|
140M-I
|
1
|
140U-I-PL
|
|
End Cap Kit Provides 3-phase connections for terminal or bolt-on connections Metric Hardware
|
140M-I
|
1
|
140U-I-ECM
|
|
Phase Barriers Provides additional phase clearance when special connections are required
|
140M-I
|
2
|
140U-I-PB
|
|
Terminal Lugs Steel Terminal Copper/Aluminum wire #4-4/0 AWG
|
140M-I
|
3
|
140U-I-TLS1
|
Terminal Lugs Stainless Steel Terminal Copper/Aluminum wire #4-4/0 AWG
|
140U-I-TLS2
|
|
Rotary Close Couple Handle International Black handle
|
140M-I
|
1
|
140U-I-RCB
|
Rotary Close Couple Handle International Red/Yellow handle
|
140U-I-RCR
|
|
Operating Mechanism for External Handles
|
140M-I
|
1
|
198-H2
|
|
External Handles
|
|
|
|
Black/Grey IP66 (Type 3/3R/4/4X/12)
|
140M-I
|
1
|
190-HM4
|
Red/Yellow IP66 (Type 3/3R/4/4X/12)
|
190-HM4E
|
Black/Grey IP55 (Type 1)
|
190-HM1
|
Red/Yellow IP55 (Type 1)
|
190-HM1E
|
|
Overload Pre-trip Auxiliary Contact (AX) Opens contactor coil circuit on overload before MPCB trips (Automatic reset)
|
140M-J, -L (MPCB only)
|
1
|
140U-J-ER1RX
|
|
|
| Description
|
For Use With
|
Pkg. Quantity
|
Cat. No.
|
|
Extension Shafts
|
140M-I
|
5
|
194R-R3
|
| Standard Enclosure Working Depth [mm (in.)]
|
| Minimum
|
203 (8)
|
| Maximum
|
305 (12)
|
| Extended
|
194R-R4
|
| Minimum
|
203 (8)
|
| Maximum
|
508 (20)
|
|
|
Package Quantity = 1 Discount Group = MAC ¬ May be ordered in quantities of 20. Add the letter M to the end of the cat. no. (Example: 140M-C-PEM12M).
|
| Description
|
For Use With
|
Pkg. Quantity
|
Cat. No.
|
|
Flex-Cable Operating Mechanism NEMA Type 1/3/12/4/4X Flange-Mount Handle
|
3 ft. (0.9 m) Cable
|
140M-I
|
1
|
140U-I-FCX03
|
| 4 ft. (1.2 m) Cable
|
140U-I-FCX04
|
| 6 ft. (1.9 m) Cable
|
140U-I-FCX06
|
| 10 ft. (3.0 m) Cable
|
140U-I-FCX10
|
Flex-Cable Operating Mechanism Stainless Steel - Type 4/4X Flange Mount Handle
|
3 ft. (0.9 m) Cable
|
140U-I-FCS03
|
| 4 ft. (1.2 m) Cable
|
140U-I-FCS04
|
| 6 ft. (1.9 m) Cable
|
140U-I-FCS06
|
| 10 ft. (3.0 m) Cable
|
140U-I-FCS10
|
|
|
|
|
Description
|
Diagram
|
Mounting Location
|
For Use With
|
Cat. No.
|
|
Auxiliary Contact (AX) Electrically indicates "ON/OFF" status of breakers
|
(1) 1a-1b
|
|
|
140M-H, -J, -L
|
140U-H-EA1
|
| 140M-N
|
140U-N-EA1
|
| (2) 1a-1b
|
140M-H, -J, -L
|
140U-H-EA2
|
| Left AND Right side
|
140M-N
|
140U-N-EA2
|
| (1) 1a-1b
|
|
140M-I (Note: adding this part in the field voids UL/CSA on the MPCB)
|
140U-I-EA1RX
|
| Right side only
|
Alarm Contact (AL) Electrically indicates when the breaker is in the "TRIPPED" state
|
(1) 1M (make)-1B (break)
|
|
|
140M-H
|
140U-H-ER1
|
| 140M-J, -L
|
140U-J-ER1
|
| Right side ONLY
|
140M-N
|
140U-N-ER1
|
|
140M-I (Note: adding this part in the field voids UL/CSA on the MPCB)
|
140U-I-ER1LX
|
| Left side ONLY
|
|
Auxiliary/Alarm Contact (AX/AL) Combination Combination of auxiliary contact and alarm contact
|
(1) 1a-1b (1) 1M (make)-1B (break)
|
|
|
140M-H
|
140U-H-EA1R1
|
| 140M-J, -L
|
140U-J-EA1R1
|
| Right side only
|
140M-N
|
140U-N-EA1R1
|
|
Overload Pre-trip Auxiliary Contact (AX) Opens contactor coil circuit on overload before MPCB trips (Automatic reset)
|
(1) 1a-1b
|
|
|
140M-J, -L (MPCB only)
|
140U-J-ER1RX
|
| Right side only
|
|
Shunt Trip (SNT) Provides remote tripping of the circuit breaker Undervoltage trip not available when shunt trip is used
|
24…60 V, 50/60/DC
|
|
|
140M-H, -J, -L
|
140U-H-SNJ
|
| 12…24V, 50/60/DC
|
140M-N
|
140U-N-SNJ
|
| 110…240V, 50/60/DC
|
140M-H, -J, -L
|
140U-H-SND
|
| 110…240V AC
|
140M-N
|
140U-N-SND
|
| 380…440V AC, 220…250V DC
|
140M-H, -J, -L
|
140U-H-SNN
|
| 380…440V AC, 220…250V DC
|
140M-N
|
140U-N-SNN
|
| 380…600V, 50/60 Hz
|
Left side ONLY
|
140M-H, -J, -L
|
140U-H-SNB
|
| 480…600V, 50/60 Hz
|
140M-N
|
140U-N-SNB
|
Undervoltage Release (UVT) Automatically trips breaker when voltage falls between preset value, 35…70% Shunt trip is not available when undervoltage release is used
|
24V, 50/60 Hz
|
|
|
140M-H, -J, -L
|
140U-H-UJ
|
| =17,1114339
|
140M-N
|
140U-N-UJ
|
| 110…127V, 50/60 Hz
|
140M-H, -J, -L
|
140U-H-UD
|
| =19,1114339
|
140M-N
|
140U-N-UD
|
| 208…240V, 50/60 Hz
|
140M-H, -J, -L
|
140U-H-UA
|
| =23,1114339
|
140M-N
|
140U-N-UA
|
| 380…500V, 50/60 Hz
|
Left side ONLY
|
140M-H, -J, -L
|
140U-H-UB
|
| =21,1114339
|
140M-N
|
140U-N-UB
|
| 525…600V, 50/60 Hz
|
140M-H, -J, -L
|
140U-H-UC
|
|
|
|
|
Description
|
For Use With
|
Cat. No.
|
|
Terminal End Cover 6.4 mm (0.25 in.) diameter cable entry
|
140M-H
|
140U-H-TC2
|
| 140M-I
|
140U-I-TC2
|
Terminal End Cover 10.4 mm (0.41 in.) diameter cable entry
|
140M-H
|
140U-H-TC4
|
| 140M-I
|
140U-I-TC4
|
|
Terminal Shields IP20 Ingress Protection Rating
|
140M-H
|
140U-H-TS
|
| 140M-I
|
140U-I-TS1
|
| 140M-J
|
140U-J-TS
|
| 140M-L
|
140U-L-TS
|
|
Flex-Cable Operating Mechanism Includes handle, cable, operating, and bail mechanism Pre-assembled and adjusted Non-Metallic - UL IP66, Type 1/3/12/4/4X Flange Mount Operating Handle
|
3 ft (0.9 m) Cable
|
140M-H
|
140U-H-FCX03
|
| 4 ft (1.3 m) Cable
|
140U-H-FCX04
|
| 6 ft (1.8 m) Cable
|
140U-H-FCX06
|
| 10 ft (3.0 m) Cable
|
140U-H-FCX10
|
| 3 ft. (0.9 m) Cable
|
140M-I
|
140U-I-FCX03
|
| 4 ft. (1.2 m) Cable
|
140U-I-FCX04
|
| 6 ft. (1.9 m) Cable
|
140U-I-FCX06
|
| 10 ft. (3.0 m) Cable
|
140U-I-FCX10
|
| 3 ft (0.9 m) Cable
|
140M-J
|
140U-J-FCX03
|
| 4 ft (1.3 m) Cable
|
140U-J-FCX04
|
| 6 ft (1.8 m) Cable
|
140U-J-FCX06
|
| 10 ft (3.0 m) Cable
|
140U-J-FCX10
|
| 4 ft (1.2 m) Cable
|
140M-L
|
140U-L-FCX04
|
| 6 ft (1.9 m) Cable
|
140U-L-FCX06
|
| 10 ft (3.0 m) Cable
|
140U-L-FCX10
|
| 4 ft. (1.2 m) Cable
|
140M-N
|
140U-N-FCX04
|
| 6 ft. (1.9 m) Cable
|
140U-N-FCX06
|
| 10 ft. (3.0 m) Cable
|
140U-N-FCX10
|
Flex-Cable Operating Mechanism Includes handle, cable, operating, and bail mechanism Pre-assembled and adjusted Stainless Steel - Type 4/4X Flange Mount Operating Handle
|
3 ft (0.9 m) Cable
|
140M-H
|
140U-H-FCS03
|
| 4 ft (1.3 m) Cable
|
140U-H-FCS04
|
| 6 ft (1.8 m) Cable
|
140U-H-FCS06
|
| 10 ft (3.0 m) Cable
|
140U-H-FCS10
|
| 3 ft. (0.9 m) Cable
|
140M-I
|
140U-I-FCS03
|
| 4 ft. (1.2 m) Cable
|
140U-I-FCS04
|
| 6 ft. (1.9 m) Cable
|
140U-I-FCS06
|
| 10 ft. (3.0 m) Cable
|
140U-I-FCS10
|
| 3 ft (0.9 m) Cable
|
140M-J
|
140U-J-FCS03
|
| 4 ft (1.3 m) Cable
|
140U-J-FCS04
|
| 6 ft (1.8 m) Cable
|
140U-J-FCS06
|
| 10 ft (3.0 m) Cable
|
140U-J-FCS10
|
| 4 ft (1.2 m) Cable
|
140M-L
|
140U-L-FCS04
|
| 6 ft (1.9 m) Cable
|
140U-L-FCS06
|
| 10 ft (3.0 m) Cable
|
140U-L-FCS10
|
|
|
|
|
Description
|
For Use With
|
Cat. No.
|
|
Rotary, Variable-Depth Operating Mechanism Rotary handle - IP66, UL Type 3/12/4/4X 12 in. (30.48 cm) operating rod
|
Black Handle
|
140M-H
|
140U-H-RVM12B
|
| Red/Yellow Handle
|
140U-H-RVM12R
|
| Black Handle
|
140M-J
|
140U-J-RVM12B
|
| Red/Yellow Handle
|
140U-J-RVM12R
|
| Black Handle
|
140M-L
|
140U-L-RVM12B
|
| Red/Yellow Handle
|
140U-L-RVM12R
|
| Black Handle
|
140M-N
|
140U-N-RM12B
|
Rotary, Variable-Depth Operating Mechanism UL Type 3/12/4/4X, IP 66 Rotary handle 21 in. (53.34 cm) operating rod
|
Black Handle
|
140M-H
|
140U-H-RVM21B
|
| Red/Yellow Handle
|
140U-H-RVM21R
|
| Black Handle
|
140M-J
|
140U-J-RVM21B
|
| Red/Yellow Handle
|
140U-J-RVM21R
|
| Black Handle
|
140M-L
|
140U-L-RVM21B
|
| Red/Yellow Handle
|
140U-L-RVM21R
|
|
Rotary, Variable-Depth Operating Mechanism with Internal NFPA 79 Operating Handle External Type 3/4/4X/12 IP66 Rotary Handle 12 in. (30.48 cm) operating rod
|
Black Handle
|
140M-H
|
140U-H-NVM12B
|
| Red/Yellow Handle
|
140U-H-NVM12R
|
| Black Handle
|
140M-J
|
140U-J-NVM12B
|
| Red/Yellow Handle
|
140U-J-NVM12R
|
| Black Handle
|
140M-L
|
140U-L-NVM12B
|
| Red/Yellow Handle
|
140U-L-NVM12R
|
Rotary, Variable-Depth Operating Mechanism with Internal NFPA 79 Operating Handle External Type 3/4/4X/12 IP66 Rotary Handle 21 in. (53.34 cm) operating rod
|
Black Handle
|
140M-H
|
140U-H-NVM21B
|
| Red/Yellow Handle
|
140U-H-NVM21R
|
| Black Handle
|
140M-J
|
140U-J-NVM21B
|
| Red/Yellow Handle
|
140U-J-NVM21R
|
| Black Handle
|
140M-L
|
140U-L-NVM21B
|
| Red/Yellow Handle
|
140U-L-NVM21R
|
|
|
|
|
Description
|
For Use With
|
Cat. No.
|
|
Operating Mechanism for External Handles
|
140M-I
|
198-H2
|
|
External Operating Handle
|
Black/Grey Handle IP66 (Type 3/3R/4/4X/12)
|
140M-I
|
190-HM4
|
Red/Yellow Handle IP66 (Type 3/3R/4/4X/12)
|
190-HM4E
|
Black/Grey Handle IP55 (Type 1)
|
190-HM1
|
Red/Yellow Handle IP55 (Type 1)
|
190-HM1E
|
|
Extension Shaft Standard length — Enclosure Working Depth Minimum: 8 in. (203 mm) Maximum: 12 in (305 mm)
|
140M-I
|
194R-R3
|
Extension Shaft Extended length — Enclosure Working Depth Minimum: 8 in. (203 mm) Maximum: 20 in (508 mm)
|
194R-R4
|
|
Motor Operator Remotely opens, closes, and resets the MPCB or MCP
|
For use with 3- or 4-Pole MCCBs, 110…240V AC/DC
|
140M-H
|
140U-H-EOPD
|
| For use with 3- or 4-Pole MCCBs, 24V DC
|
140U-H-EOPZ
|
| For use with 3- or 4-Pole MCCBs, 110…240V AC/DC
|
140M-J
|
140U-J-EOPD
|
| For use with 3- or 4-Pole MCCBs, 24V DC
|
140U-J-EOPZ
|
| For use with 3- or 4-Pole MCCBs, 110…240V AC/DC
|
140M-L
|
140U-L-EOPD
|
| For use with 3- or 4-Pole MCCBs, 24V DC
|
140U-L-EOPZ
|
| For use with 3- or 4-Pole MCCBs, 110…240V AC/DC
|
140M-N
|
140U-N-EOPD
|
| For use with 3- or 4-Pole MCCBs, 230…240V AC/DC
|
140U-N-EOPA
|
| For use with 3- or 4-Pole MCCBs, 24V DC
|
140U-N-EOPZ
|
|
Rotary, Direct Couple Operating Mechanism Rotary handle - IP42 UL Type 1 Breaker mounted
|
Black Handle
|
140M-H
|
140U-H-RCB
|
| Black Handle
|
140U-H-RCB
|
| Black Handle
|
140M-I
|
140U-I-RCB
|
| Red/Yellow Handle
|
140U-I-RCR
|
| Black Handle
|
140M-J
|
140U-J-RCB
|
| Red/Yellow Handle
|
140U-J-RCR
|
| For use with 3- or 4-Pole MCCBs
|
140M-L
|
140U-L-RMX
|
|
End Cap Kit Provides three-phase connections for terminal or bolt-on connections Metric hardware provided
|
140M-H
|
140U-H-ECM
|
| 140M-I
|
140U-I-ECM
|
| 140M-J
|
140U-J-ECM
|
| 140M-L
|
140U-L-ECM
|
|
Padlock Kit Padlocking hasp Lock-OFF only
|
140M-H
|
140U-H-PL
|
| 140M-I
|
140U-I-PL
|
| 140M-J
|
140U-J-PL
|
| 140M-N
|
140U-N-PL
|
|
DIN Rail Adapter Allows H-frame MCCB to mount to 35 mm DIN Rail
|
140M-H
|
140U-H-DRA
|
|
Phase Barriers Provides additional phase clearance when special connections that extend past the circuit breaker housing are required
|
Qty: 2
|
140M-H
|
140U-H-PB
|
| 140M-I
|
140U-I-PB
|
| 140M-J
|
140U-J-PB
|
| 140M-L
|
140U-K-PB
|
| 140M-N
|
140U-N-PB
|
|
Plug-in Base Adapters Plug-in provides power terminations and adapter for applications where the ability to quickly remove or replace the circuit breakers is required
|
140M-H
|
140U-H-PAD3
|
Plug-in Base Auxiliary Contacts Provides auxiliary contact functions to detect breaker installation status
|
140M-H
|
140U-H-PDK
|
|
Replacement Mounting Hardware
|
(4) M4 - 0.7 x 75 mm
|
140M-H
|
140U-H-MHM
|
| Replacement Mounting Hardware
|
(4) M4 - 0.7 x 90 mm
|
140M-J
|
140U-J-MHM
|
| Replacement Mounting Hardware
|
(4) M5 - 0.8 x 100 mm
|
140M-L
|
140U-L-MHM
|
| Replacement Mounting Hardware
|
(4) M8 - 1 x 35 mm
|
140M-N
|
140U-N-MHM
|
|
|
|
|
Description
|
Frame Size
|
Cat. No.
|
|
Terminal Lugs
|
Steel Terminal Copper/Aluminum wire #4-4/0 AWG
|
Qty: 3
|
I
|
140U-I-TLS1
|
Stainless Steel Terminal Copper/Aluminum wire #4-4/0 AWG
|
Qty: 3
|
I
|
140U-I-TLS2
|
|
Terminal Lugs
|
Aluminum lugs, Al or Cu wire (1) 4…350 MCM or (1) 25…185 mm2
|
Qty: 1
|
J
|
140U-J-TLA1
|
Stainless Steel Box Lugs, Cu wire Only (1) 4…350 MCM or (1) 25…185 mm2
|
Qty: 1
|
J
|
140U-J-TLS1
|
|
Terminal Lugs
|
Aluminum lug, Al or Cu wire (1) 2…500 MCM or (1) 35…240 mm2
|
Qty: 1
|
L
|
140U-L-TL4A1
|
Copper lug, Cu wire only (1) 2…500 MCM or (1) 35…240 mm2
|
Qty: 1
|
140U-L-TL4C1
|
Aluminum lug, Al or Cu wire (1) 500…750 MCM or (1) 240…380 mm2
|
Qty: 3 (includes shield)
|
140U-L-TL6A1
|
Copper lug, Cu wire only (1) 500…750 MCM or (1) 240…380 mm2
|
Qty: 3 (includes shield)
|
140U-L-TL6C1
|
|
Terminal Lugs
|
Aluminum lug, Al or Cu wire (2) 2…500 MCM or (2) 35…240 mm2
|
Qty: 3 (includes shield)
|
L
|
140U-L-TL6A2
|
Copper lug, Cu wire only (2) 2…500 MCM or (2) 35…240 mm2
|
Qty: 3 (includes shield)
|
140U-L-TL6C2
|
|
|
|
|
|
Description
|
Frame Size
|
Cat. No.
|
|
Terminal Lugs
|
Aluminum lug, Al or Cu wire (2) 1…500 MCM or (2) 50…240 mm2
|
Qty: 1
|
N
|
140U-N-TLA2
|
Aluminum lug, Al or Cu wire (3) 3/0…400 MCM or (3) 95…185 mm2
|
Qty: 1
|
N
|
140U-N-TLA3
|
Aluminum lug, Al or Cu wire (4) 4/0…500 MCM or (4) 120…300 mm2
|
Qty: 1
|
N
|
140U-N-TLA4
|
Aluminum lug, Al or Cu wire (3) 500…750 MCM or (3) 300…400 mm2
|
Qty: 1
|
N
|
140U-N-TLA3A
|
Copper lug, Cu wire only (2) 2/0…500 MCM or (2) 70…240 mm2
|
Qty: 1
|
N
|
140U-N-TLC2
|
Copper lug, Cu wire only (3) 3/0…500 MCM or (3) 95…240 mm2
|
Qty: 1
|
140U-N-TLC3
|
Copper lug, Cu wire only (4) 3/0…400 MCM or (4) 95…185 mm2
|
Qty: 1
|
140U-N-TLC4
|
|
|
| f
|
| Miscellaneous
|
| Code
|
Description
|
Frame Size
|
| KN
|
Black Lockable Knob
|
C, D, F, CMN
|
| KY
|
Red/Yellow Lockable Knob
|
C, D, F, CMN
|
| TE
|
Spacing Adapter for Self-Protected Starters (Type E)
|
C, D, F
|
| MT
|
STD Bus Bar Mount, Top
|
C, D, F, H, CMN
|
| MU
|
STD Bus Bar Mount, Universal
|
J, K, L
|
| g
|
| Aux / Trip Contacts - C, D, F
|
| 1st Code
|
Description
|
2nd Code
|
Description
|
| Bottom Front
|
Right Side
|
| X
|
Placeholder
|
X
|
Placeholder
|
| A
|
1 N.C.
|
C
|
1 N.O. + 1 N.C.
|
| B
|
1 N.O.
|
D
|
2 N.O.
|
| C
|
1 N.O. + 1 N.C.
|
E
|
2 N.C.
|
| D
|
2 N.O.
|
K
|
1 N.C. (SC+OL) + 1 N.C. (SC)
|
| E
|
2 N.C.
|
L
|
1 N.O. (SC+OL) + 1 N.O. (SC)
|
| R
|
1 N.C. + 1 N.O. (SC+OL)
|
M
|
1 N.C. (SC+OL) + 1 N.O. (SC)
|
| S
|
1 N.O. + 1 N.O. (SC+OL)
|
N
|
1 N.O. (SC+OL) + 1 N.C. (SC)
|
|
|
|
Q
|
1 N.O. (SC) + 1 N.C. (SC)
|
| g
|
| Aux / Trip Contacts - CMN
|
| 1st Code
|
Description
|
2nd Code
|
Description
|
| Bottom Front
|
Top Front
|
| X
|
Placeholder
|
X
|
Placeholder
|
| C
|
1 N.O. + 1 N.C.
|
K
|
1 N.C. (OL) + 1 N.C. (SC)
|
| D
|
2 N.O.
|
L
|
1 N.O. (OL) + 1 NO (SC)
|
| E
|
2 N.C.
|
M
|
1 N.C. (OL) + 1 N.O. (SC)
|
|
|
|
N
|
1 N.O. (OL) + 1 N.C. (SC)
|
|
|
| g
|
| Aux / Trip Contacts - H, J, L
|
| 1st Code
|
Description
|
2nd Code
|
Description
|
| Bottom Front
|
Right Side
|
| X
|
Placeholder
|
X
|
Placeholder
|
| C
|
1 N.O. + 1 N.C.
|
| RT
|
1 N.O. + 1 N.C. (Overload Function)
|
| F¬
|
2 N.O. + 2 N.C.
|
| N¬
|
1 N.O. (SC+OL) + 1 N.C. (SC)
|
| T¬
|
1 N.O. + 1 N.C. and 1 N.O. + 1 N.C. (SC+OL)
|
| g
|
| Aux / Trip Contacts - I, N
|
| 1st Code
|
Description
|
2nd Code
|
Description
|
| Left Side
|
Right Side
|
| X
|
Placeholder
|
X
|
Placeholder
|
| C
|
1 N.O. + 1 N.C.
|
C
|
1 N.O. + 1 N.C.
|
| F
|
2 N.O. + 2 N.C.
|
F¬
|
2 N.O. + 2 N.C.
|
| N
|
1 N.O. (SC+OL) + 1 N.C. (SC)
|
N¬
|
1 N.O. (SC+OL) + 1 N.C. (SC)
|
| T
|
1 N.O. + 1 N.C. and 1 N.O. + 1 N.C. (SC+OL)
|
T¬
|
1 N.O. + 1 N.C. and 1 N.O. + 1 N.C. (SC+OL)
|
| h
|
| UV and Shunt Trips - C, D, F
|
| 1st Code
|
Description
|
2nd Code
|
Description
|
| Left Side
|
Voltage
|
| G
|
Undervoltage Trip
|
J
|
24V AC, 60 Hz
|
| P
|
Shunt Trip
|
K
|
24V AC, 50 Hz
|
| D
|
120V AC, 60 Hz
|
| C
|
110V AC, 50 Hz
|
| H
|
208V AC, 60 Hz
|
| F
|
220…230V AC, 50 Hz
|
| A
|
240V AC, 60 Hz
|
| T
|
277V AC, 50 Hz
|
| N
|
380…400V AC, 50 Hz
|
| B
|
480V AC, 60 Hz and 415V AC, 50 Hz
|
| VC
|
600V AC, 60 Hz
|
| M
|
575V AC, 60 Hz and 500V AC, 50 Hz
|
| ZR
|
9V DC
|
| ZQ
|
12V DC
|
| ZJ
|
24V DC
|
| ZW
|
36V DC
|
| ZY
|
48V DC
|
| ZZ
|
60V DC
|
| ZB
|
64V DC
|
| ZG
|
72V DC
|
| ZE
|
80V DC
|
| h
|
| UV and Shunt Trips - CMN
|
| 1st Code
|
Description
|
2nd Code
|
Description
|
| Top Front
|
Voltage
|
| G
|
Undervoltage Trip
|
KJ
|
24V AC, 60 Hz and 24V AC, 50 Hz
|
| P
|
Shunt Trip
|
D
|
120V AC, 60 Hz and 110V AC, 50 Hz
|
| A
|
240V AC, 60 Hz and 220…230V AC, 50 Hz
|
|
|
| Cannot be combined with option "g".
|
| h
|
| UV and Shunt Trips - H, J, L
|
| 1st Code
|
Description
|
2nd Code
|
Description
|
| Left Front
|
UV Voltage
|
| G
|
Undervoltage Trip
|
J
|
24V AC/DC
|
| D
|
110…127V AC
|
| A
|
208…240V AC
|
| B
|
380…500V AC
|
| C
|
525…600V AC
|
| Left Front
|
Shunt Voltage
|
| P
|
Shunt Trip
|
J
|
12…60V AC/DC
|
| D
|
110…240V AC/DC
|
| B
|
380…600V AC
|
| h
|
| UV and Shunt Trips - I
|
| 1st Code
|
Description
|
2nd Code
|
Description
|
| Left Front
|
UV Voltage
|
| G
|
Undervoltage Trip
|
J
|
24V AC
|
| D
|
110…127V AC
|
| A
|
208…240V AC
|
| B
|
380…480V AC
|
| Left Front
|
Shunt Voltage
|
| P
|
Shunt Trip
|
J
|
12…24V AC/DC
|
| D
|
48…127V AC and 48…60V DC
|
| N
|
208…380V AC and 110…127V DC
|
| B
|
415…600V AC and 220…250V DC
|
| h
|
| UV and Shunt Trips - N
|
| 1st Code
|
Description
|
2nd Code
|
Description
|
| Left Front
|
UV Voltage
|
| G
|
Undervoltage Trip
|
J
|
24V AC
|
| D
|
110…127V AC
|
| A
|
208…240V AC
|
| B
|
380…480V AC
|
| Left Front
|
Shunt Voltage
|
| P
|
Shunt Trip
|
J
|
12…24V AC/DC
|
| D
|
110…240V AC and 110…125V DC
|
| N
|
380…440V AC and 220…250V DC
|
| B
|
480…600V AC
|