| Rated Operational Current (Ie) [A]
|
Motor Current Adjustment Range [A]
|
Magnetic Trip Current [A]
|
Ultimate Interrupting Current [kA] (Icu)
|
Max. 3-phase Hp Ratings¬
|
Max. kW, 3-Phase¬
|
Cat. No.
|
| 400V
|
480V
|
200V
|
230V
|
460V
|
575V
|
230V
|
400/415V
|
500V
|
690V
|
| C-Frame
|
| 0.16
|
0.10…0.16
|
2.1
|
100
|
65
|
—
|
—
|
—
|
—
|
—
|
0.02
|
—
|
—
|
140M-C2E-A16
|
| 0.25
|
0.16…0.25
|
3.3
|
100
|
65
|
—
|
—
|
—
|
—
|
—
|
0.06
|
—
|
—
|
140M-C2E-A25
|
| 0.4
|
0.25…0.40
|
5.2
|
100
|
65
|
—
|
—
|
—
|
—
|
—
|
0.09
|
—
|
—
|
140M-C2E-A40
|
| 0.63
|
0.40…0.63
|
8.2
|
100
|
65
|
—
|
—
|
—
|
—
|
0.09
|
0.18
|
0.18
|
0.25
|
140M-C2E-A63
|
| 1
|
0.63…1.0
|
13
|
100
|
65
|
—
|
—
|
0.5
|
0.75
|
0.12
|
0.25
|
0.37
|
0.55
|
140M-C2E-B10
|
| 1.6
|
1.0…1.6
|
21
|
100
|
65
|
—
|
—
|
0.5…1
|
0.75…1
|
0.25
|
0.55
|
0.75
|
1.1
|
140M-C2E-B16
|
| 2.5
|
1.6…2.5
|
33
|
100
|
65
|
0.5
|
0.75
|
0.75…1.5
|
1…2
|
0.37
|
0.75
|
1.1
|
1.8
|
140M-C2E-B25
|
| 4
|
2.5…4.0
|
52
|
100
|
65
|
1
|
1
|
1.5…3
|
2…3
|
0.75
|
1.5
|
2.2
|
3
|
140M-C2E-B40
|
| 6.3
|
4.0…6.3
|
82
|
100
|
65
|
1.5
|
2
|
3…5
|
5
|
1.5
|
2.2
|
3
|
4
|
140M-C2E-B63
|
| 10
|
6.3…10
|
130
|
100
|
65
|
3
|
3
|
5…7.5
|
7.5…10
|
2.2
|
4
|
6.3
|
7.5
|
140M-C2E-C10
|
| 16
|
10…16
|
208
|
50
|
30
|
5
|
5
|
7.5…10
|
10…15
|
4
|
7.5
|
10
|
13
|
140M-C2E-C16
|
| 20
|
14.5…20
|
260
|
15
|
30
|
5
|
7.5
|
15
|
20
|
5.5
|
10
|
11
|
17
|
140M-C2E-C20
|
| 25
|
18…25
|
325
|
15
|
25
|
7.5
|
7.5
|
15
|
20
|
—
|
11
|
15
|
22
|
140M-C2E-C25
|
| D-Frame
|
| 2.5
|
1.6…2.5
|
33
|
100
|
65
|
0.5
|
0.75
|
0.75…1.5
|
1…2
|
0.37
|
0.75
|
1.1
|
1.8
|
140M-D8E-B25
|
| 4
|
2.5…4.0
|
52
|
100
|
65
|
1
|
1
|
1.5…3
|
2…3
|
0.75
|
1.5
|
2.2
|
3
|
140M-D8E-B40
|
| 6.3
|
4.0…6.3
|
82
|
100
|
65
|
1.5
|
2
|
3…5
|
5
|
1.5
|
2.2
|
3
|
4
|
140M-D8E-B63
|
| 10
|
6.3…10
|
130
|
100
|
65
|
3
|
3
|
5…7.5
|
7.5…10
|
2.2
|
4
|
6.3
|
7.5
|
140M-D8E-C10
|
| 16
|
10…16
|
208
|
100
|
65
|
5
|
5
|
7.5…10
|
10…15
|
4
|
7.5
|
10
|
13
|
140M-D8E-C16
|
| 20
|
14.5…20
|
260
|
50
|
65
|
5
|
7.5
|
15
|
20
|
5.5
|
10
|
11
|
17
|
140M-D8E-C20
|
| 25
|
18…25
|
325
|
50
|
30
|
7.5
|
7.5
|
15
|
20
|
—
|
11
|
15
|
22
|
140M-D8E-C25
|
| F-Frame
|
| 10
|
6.3…10
|
130
|
65
|
65
|
3
|
3
|
5…7.5
|
7.5…10
|
2.2
|
4
|
6.3
|
7.5
|
140M-F8E-C10
|
| 16
|
10…16
|
208
|
65
|
65
|
5
|
5
|
7.5…10
|
10…15
|
4
|
7.5
|
10
|
13
|
140M-F8E-C16
|
| 20
|
14.5…20
|
260
|
65
|
65
|
5
|
7.5
|
15
|
15…20
|
5.5
|
10
|
11
|
17
|
140M-F8E-C20
|
| 25
|
18…25
|
325
|
65
|
65
|
7.5
|
10
|
15…20
|
25
|
6.3
|
11
|
15
|
22
|
140M-F8E-C25
|
| 32
|
23…32
|
416
|
65
|
65
|
7.5
|
10
|
20…25
|
25…30
|
7.5
|
15
|
20
|
25
|
140M-F8E-C32
|
| 45
|
32…45
|
585
|
65
|
65
|
10
|
15
|
30
|
40
|
13
|
22
|
30
|
40
|
140M-F8E-C45
|
| CMN-Frame
|
| 25
|
16…25
|
350
|
65
|
65
|
5
|
7.5
|
15
|
20
|
7.5
|
13
|
15
|
22
|
140-CMN-2500
|
| 40
|
25…40
|
560
|
65
|
65
|
10
|
10
|
30
|
30
|
11
|
22
|
25
|
30
|
140-CMN-4000
|
| 63
|
40…63
|
882
|
65
|
42
|
20
|
20
|
40
|
60
|
20
|
32
|
40
|
55
|
140-CMN-6300
|
| 90
|
63…90
|
1260
|
50
|
35
|
25
|
30
|
60
|
75
|
25
|
45
|
55
|
75
|
140-CMN-9000
|
|
|
¬ Horsepower/kW ratings shown in the table above are for reference. The final selection of the MPCB depends on the actual motor full load current.
|
| Rated Operational Current [A] (Ie)
|
Motor Current Adjustment Range [A]
|
Magnetic Trip Current [A]
|
Ultimate Interrupting Current [kA] (Icm)
|
3-phase Hp Ratings¬
|
Max. kW, 3-Phase¬
|
Cat. No.
|
| 400V
|
480V
|
200V
|
230V
|
460V
|
575V
|
230V
|
400/415V
|
500V
|
690V
|
| I-Frame
|
| 80
|
40…80
|
1200
|
70T
|
65
|
25
|
30
|
60
|
75
|
22
|
37
|
55
|
75
|
140M-I8E-C80T
|
| 100
|
80…100
|
1500
|
70T
|
65
|
30
|
40
|
75
|
100
|
30
|
55
|
55
|
90
|
140M-I8E-D10T
|
| 160
|
100…160
|
2400
|
70T
|
65
|
50
|
60
|
125
|
150
|
45
|
75
|
110
|
132
|
140M-I8E-D16T
|
| 205
|
160…205
|
2665
|
70T
|
65
|
60
|
75
|
150
|
200
|
55
|
110
|
132
|
200
|
140M-I8E-D20T §
|
| J-Frame
|
| 50
|
20…50
|
700
|
25
|
25
|
25
|
30
|
60
|
75
|
15
|
22
|
30
|
45
|
140M-J2E-C50
|
| 100
|
40…100
|
1400
|
25
|
25
|
30
|
40
|
75
|
100
|
30
|
55
|
55
|
90
|
140M-J2E-D10
|
| 160
|
64…160
|
2240
|
25
|
25
|
50
|
60
|
125
|
150
|
45
|
90
|
110
|
160
|
140M-J2E-D16
|
| 250
|
100…250
|
3500
|
25
|
25
|
75
|
100
|
200
|
250
|
55
|
132
|
160
|
250
|
140M-J2E-D25
|
|
|
| 50
|
20…50
|
700
|
70
|
65
|
25
|
30
|
60
|
75
|
15
|
22
|
30
|
45
|
140M-J8E-C50
|
| 100
|
40…100
|
1400
|
70
|
65
|
30
|
40
|
75
|
100
|
30
|
55
|
55
|
90
|
140M-J8E-D10
|
| 160
|
64…160
|
2240
|
70
|
65
|
50
|
60
|
125
|
150
|
45
|
90
|
110
|
160
|
140M-J8E-D16
|
| 250
|
100…250
|
3500
|
70
|
65
|
75
|
100
|
200
|
250
|
55
|
132
|
160
|
250
|
140M-J8E-D25
|
| L-Frame
|
| 250
|
100…250
|
3000
|
40
|
35
|
75
|
100
|
200
|
250
|
55
|
132
|
160
|
250
|
140M-L2E-D25
|
| 400
|
160…400
|
4800
|
40
|
35
|
125
|
150
|
300
|
400
|
132
|
200
|
250
|
400
|
140M-L2E-D40
|
| 630
|
250…630
|
7580
|
40
|
35
|
200
|
250
|
500
|
600
|
200
|
355
|
450
|
630
|
140M-L2E-D63
|
|
|
| 250
|
100…250
|
3000
|
70
|
65
|
75
|
100
|
200
|
250
|
55
|
132
|
160
|
250
|
140M-L8E-D25
|
| 400
|
160…400
|
4800
|
70
|
65
|
150
|
150
|
350
|
450
|
132
|
200
|
250
|
400
|
140M-L8E-D40
|
| 630
|
250…630
|
7560
|
70
|
65
|
200
|
250
|
500
|
600
|
200
|
355
|
450
|
630
|
140M-L8E-D63
|
|
|
| ¬ Horsepower/kW ratings shown in the table above are for reference. The final selection of the MPCB depends on the actual motor full load current.
|
| T For IEC approvals and CE marking, add an "E" to the end of the Cat. No. Example: 140M-18E-C80E.
|
| Overload Protection — adjustable Trip Class 5, 10, 15, or 20.
|
| § Overload Protection — fixed Trip Class 10.
|
| Rated Operational Current [A] (Ie)
|
Motor Current Adjustment Range [A]
|
Magnetic Trip Current [A]
|
Ultimate Interrupting Current [kA] (Icm)
|
Max. 3-phase Hp Ratings¬
|
Max kW, 3-Phase¬
|
Cat. No.
|
| 400V
|
480V
|
200V
|
230V
|
460V
|
575V
|
230V
|
400/415V
|
500V
|
690V
|
| C-Frame
|
| 0.16
|
0.10…0.16
|
3.3
|
100
|
65
|
—
|
—
|
—
|
—
|
—
|
0.02
|
—
|
—
|
140M-C2T-A16
|
| 0.25
|
0.16…0.25
|
5.2
|
100
|
65
|
—
|
—
|
—
|
—
|
—
|
0.06
|
—
|
—
|
140M-C2T-A25
|
| 0.4
|
0.25…0.40
|
8.2
|
100
|
65
|
—
|
—
|
—
|
—
|
—
|
0.09
|
—
|
—
|
140M-C2T-A40
|
| 0.63
|
0.40…0.63
|
13
|
100
|
65
|
—
|
—
|
—
|
—
|
0.09
|
0.18
|
0.18
|
0.25
|
140M-C2T-A63
|
| 1
|
0.63…1.0
|
21
|
100
|
65
|
—
|
—
|
0.5
|
0.75
|
0.12
|
0.25
|
0.37
|
0.55
|
140M-C2T-B10
|
| 1.6
|
1.0…1.6
|
33
|
100
|
65
|
—
|
—
|
1
|
1
|
0.25
|
0.55
|
0.75
|
1.1
|
140M-C2T-B16
|
| 2.5
|
1.6…2.5
|
52
|
100
|
65
|
0.5
|
0.75
|
1.5
|
2
|
0.37
|
0.75
|
1.1
|
1.8
|
140M-C2T-B25
|
| 4
|
2.5…4
|
82
|
100
|
65
|
1
|
1
|
3
|
3
|
0.75
|
1.5
|
2.2
|
3
|
140M-C2T-B40
|
| 6.3
|
4…6.3
|
130
|
100
|
65
|
1.5
|
2
|
5
|
5
|
1.5
|
2.2
|
3
|
4
|
140M-C2T-B63
|
| 10
|
6.3…10
|
208
|
50
|
30
|
3
|
3
|
7.5
|
10
|
2.2
|
4
|
6.3
|
7.5
|
140M-C2T-C10
|
| 16
|
10…16
|
260
|
15
|
30
|
5
|
5
|
10
|
15
|
4
|
7.5
|
10
|
13
|
140M-C2T-C16
|
| D-Frame
|
| 16
|
10…16
|
260
|
50
|
65
|
5
|
5
|
10
|
15
|
4
|
7.5
|
10
|
13
|
140M-D8T-C16
|
| 20
|
14.5…20
|
325
|
50
|
30
|
5
|
7.5
|
15
|
20
|
5.5
|
10
|
11
|
17
|
140M-D8T-C20
|
| F-Frame
|
| 25
|
18…25
|
416
|
65
|
65
|
7.5
|
10
|
20
|
25
|
6.3
|
11
|
15
|
22
|
140M-F8T-C25
|
| 32
|
23…32
|
585
|
65
|
65
|
7.5
|
10
|
25
|
30
|
7.5
|
15
|
20
|
25
|
140M-F8T-C32
|
|
|
| ¬ Horsepower/kW ratings shown in the table above are for reference. The final selection of the MPCB depends on the actual motor full load current and, in North America, service factor.
|