Bulletin 140G Product Selection

Product Selection — 125 A, G-Frame Product Selection — 125 A, H-Frame Product Selection — 225 A I-Frame Product Selection — 250 A J-Frame Product Selection — 400 A K-Frame
Product Selection — 800 A M-Frame Product Selection — 1200 A N-Frame Product Selection — 1200 A NS-Frame Product Selection — 2500…3000 A R-Frame
Product Selection — 800 A M-Frame

Click to enlarge - breaker_frame_generic + Click to enlarge - 140G-MTF3-D80-01 TU = Click to enlarge - 140G-M6F3-D80 Facing Right
Frame   Trip Unit   MCCB

Breaker Frames & Trip Units

Breaker Frames, 800 A Rated Current

Interrupting Rating (50/60 Hz), UL 489/CSA C22.2-5, No. 5-02 [kA] Breaking Capacity (50/60 Hz), IEC 60947-2 Breaking Capacity (DC), IEC 60947-2 §  Cat. No.
240V 480V 600V 3-Pole in series 220V⋆  415V 690V 750V DC (3-pole in series)
600V DC Icu [kA] Ics [%Icu] Icu [kA] Ics [%Icu] Icu [kA] Ics [%Icu] Icu [kA] Ics [%Icu] 3 Poles 4 Poles
100 50 25 20 85 100 50 100 22 75 16 75 140G-M5X3 140G-M5X4
200 65 35 35 100 100 70 100 25 75 36 75 140G-M6X3 140G-M6X4
200 100 42 50 200 75 100 75 30 75 50 75 140G-M0X3 140G-M0X4
  
⋆ These ratings have not been tested for the CCC listing.
‡ See table below for Cat. No. selection
§ DC rating is applicable for thermal-magnetic trip unit only.

Trip Units, Thermal-Magnetic

Rated
Current
In [A]
Thermal Trip [A]
Ir = In
Magnetic Trip [A]
Im
Protection Type Cat. No.
3 Poles 4 Poles
600 420…630 3000…6000 F (Adjustable Thermal/ Adjustable Magnetic) 140G-MTF3-D60 140G-MTF3-D60
800 560…800 4000…8000 F (Adjustable Thermal/ Adjustable Magnetic) 140G-MTF3-D80 140G-MTF4-D80
  

Trip Units, Electronic LSI (Long, Short, Instantaneous)

Rated
Current
In [A]
Protection Type Cat. No.
L S I 3 Poles 4 Poles
I1=0.4…1 x In t1=sec. I2=0.6…10 x In t2=sec. I3=1.5…12 x In
600 240…600 3, 6, 9, 18 360…6000 0.05, 0.1, 0.25, 0.5 900…7200 140G-MTH3-D60 140G-MTH4-D60
800 320…800 3, 6, 9, 18 480…8000 0.05, 0.1, 0.25, 0.5 800…8400 140G-MTH3-D80 140G-MTH4-D80
  

Trip Units, Electronic LSIG (Long, Short, Instantaneous, Ground Fault)

Rated
Current
In [A]
Protection Type Cat. No.
L S I G 3 Poles 4 Poles
I1=0.4…1 x In t1=sec. I2=0.6…10 x In t2=sec. I3=1.5…12 x In I4=0.2…1 x In t4=sec.
600 240…600 3, 6, 9, 18 360…6000 0.05, 0.1, 0.25, 0.5 900…7200 120…600 0.1, 0.2, 0.4, 0.8 140G-MTI3-D60 140G-MTI4-D60
800 320…800 3, 6, 9, 18 480…8000 0.05, 0.1, 0.25, 0.5 800…8400 160…800 0.1, 0.2, 0.4, 0.8 140G-MTI3-D80 140G-MTI4-D80
  

Trip Units, Electronic LSIG-MM (Long, Short, Instantaneous, Ground Fault - Maintenance Mode)

Rated
Current
In [A]
Protection Type Cat. No.
L S I G 3 Poles 4 Poles
I1=0.4…1 x In t1=sec. I2=0.6…10 x In t2=sec. I3=1.5…12 x In I4=0.2…1 x In t4=sec.
600 240…600 3, 6, 9, 18 360…6000 0.05, 0.1, 0.25, 0.5 900…7200 120…600 0.1, 0.2, 0.4, 0.8 140G-MTK3-D60 140G-MTK4-D60
800 320…800 3, 6, 9, 18 480…8000 0.05, 0.1, 0.25, 0.5 800…8400 160…800 0.1, 0.2, 0.4, 0.8 140G-MTK3-D80 140G-MTK4-D80
  

Assembled Molded Case Circuit Breakers — 800 A M-Frame

Interrupting Rating/Breaking Capacity — Thermal-Magnetic Circuit Breakers

Click to enlarge - 140G-M6F3-D80 Facing Right


Interrupting Rating (50/60 Hz), UL 489/CSA C22.2-5, No. 5-02 [kA] Breaking Capacity (50/60 Hz), IEC 60947-2 Breaking Capacity (DC), IEC 60947-2 Interrupting Code‡ 
240V 480V 600V 3-Pole in series 220V⋆  415V 690V 750V DC (3-pole in series)
600V DC Icu [kA] Ics [%Icu] Icu [kA] Ics [%Icu] Icu [kA] Ics [%Icu] Icu [kA] Ics [%Icu]
100 50 25 20 85 100 50 100 22 75 16 75 M5
200 65 35 35 100 100 70 100 25 75 36 75 M6
200 100 42 50 200 75 100 75 30 75 50 75 M0
  
⋆ These ratings have not been tested for the CCC listing.
‡ See table below for Cat. No. selection

Thermal-Magnetic, Adjustable & Adjustable

Rated
Current
In [A]
Thermal Trip [A]
Ir = In
Magnetic Trip [A]
Im
Protection Type Interrupting Code M5 Interrupting Code M6 Interrupting Code M0
Cat. No. Cat. No. Cat. No.
3 Poles 4 Poles 3 Poles 4 Poles 3 Poles 4 Poles
600 420…630 3000…6000 F (Adjustable Thermal/Adjustable Magnetic) 140G-M5F3-D60 140G-M5F4-D60 140G-M6F3-D60 140G-M6F4-D60 140G-M0F3-D60 140G-M0F4-D60
630 §  441…630 3150…6300 140G-M5F3-D63 140G-M5F4-D63 140G-M6F3-D63 140G-M6F4-D63 140G-M0F3-D63 140G-M0F4-D63
800 560…800 4000…8000 140G-M5F3-D80 140G-M5F4-D80 140G-M6F3-D80 140G-M6F4-D80 140G-M0F3-D80 140G-M0F4-D80
  
§ IEC only.

Interrupting Rating/Breaking Capacity — Electronic Circuit Breakers

Click to enlarge - 140G-M6H3-D80 Facing Right


Interrupting Rating (50/60 Hz), UL 489/CSA C22.2-5, No. 5-02 [kA] Breaking Capacity (50/60 Hz), IEC 60947-2 Breaking Capacity (DC), IEC 60947-2 Interrupting Code‡ 
240V 480V 600V 3-Pole in series 220V⋆  415V 690V 750V DC (3-pole in series)
600V DC Icu [kA] Ics [%Icu] Icu [kA] Ics [%Icu] Icu [kA] Ics [%Icu] Icu [kA] Ics [%Icu]
100 50 25 20 85 100 50 100 22 75 16 75 M5
200 65 35 35 100 100 70 100 25 75 36 75 M6
200 100 42 50 200 75 100 75 30 75 50 75 M0
  
⋆ These ratings have not been tested for the CCC listing.
‡ See table below for Cat. No. selection

Electronic LSI (Long, Short, Instantaneous)

Rated
Current
In [A]
Protection Type Interrupting Code M5 Interrupting Code M6
L S I Cat. No. Cat. No. Cat. No.
I1=0.4…1 x In t1=sec. I2=1…10 x In t2=sec. I3=1…10 x In 3 Poles 4 Poles 4 Poles 3 Poles
600 240…600 3, 6, 9, 18 360…6000 0.05, 0.1, 0.25, 0.5 900…7200 140G-M5H3-D60 140G-M5H4-D60 140G-M6H3-D60 140G-M6H4-D60
630 §  252…630 3, 6, 9, 18 378…6300 0.05, 0.1, 0.25, 0.5 945…7560 140G-M5H3-D63 140G-M5H4-D63 140G-M6H3-D63 140G-M6H4-D63
800 320…800 3, 6, 9, 18 480…8000 0.05, 0.1, 0.25, 0.5 800…8400 140G-M5H3-D80 140G-M5H4-D80 140G-M6H3-D80 140G-M6H4-D80
  
§ IEC only.

Rated
Current
In [A]
Protection Type Interrupting Code M0
L S I Cat. No.
I1=0.4…1 x In t1=sec. I2=1…10 x In t2=sec. I3=1…10 x In 3 Poles 4 Poles
600 240…600 3, 6, 9, 18 360…6000 0.05, 0.1, 0.25, 0.5 900…7200 140G-M0H3-D60 140G-M0H4-D60
630 §  252…630 3, 6, 9, 18 378…6300 0.05, 0.1, 0.25, 0.5 945…7560 140G-M0H3-D63 140G-M0H4-D63
800 320…800 3, 6, 9, 18 480…8000 0.05, 0.1, 0.25, 0.5 800…8400 140G-M0H3-D80 140G-M0H4-D80
  
§ IEC only.

Electronic LSIG (Long, Short, Instantaneous, Ground Fault)

Rated
Current
In [A]
Protection Type Interrupting Code M5 Interrupting Code M6
L S I G Cat. No. Cat. No.
I1=0.4…1 x In t1=sec. I2=1…10 x In t2=sec. I3=1…10 x In I4=0.2…1 x In t4=sec. 3 Poles 4 Poles 3 Poles 4 Poles
600 240…600 3, 6, 9, 18 360…6000 0.05, 0.1, 0.25, 0.5 900…7200 120…600 0.1, 0.2, 0.4, 0.8 140G-M5I3-D60 140G-M5I4-D60 140G-M6I3-D60 140G-M6I4-D60
630 §  252…630 3, 6, 9, 18 378…6300 0.05, 0.1, 0.25, 0.5 945…7560 126…630 0.1, 0.2, 0.4, 0.8 140G-M5I3-D63 140G-M5I4-D63 140G-M6I3-D63 140G-M6I4-D63
800 320…800 3, 6, 9, 18 480…8000 0.05, 0.1, 0.25, 0.5 800…8400 160…800 0.1, 0.2, 0.4, 0.8 140G-M5I3-D80 140G-M5I4-D80 140G-M6I3-D80 140G-M6I4-D80
  
§ IEC only.

Rated
Current
In [A]
Protection Type Interrupting Code M0
L S I G Cat. No.
I1=0.4…1 x In t1=sec. I2=1…10 x In t2=sec. I3=1…10 x In I4=0.2…1 x In t4=sec. 3 Poles 4 Poles
600 240…600 3, 6, 9, 18 360…6000 0.05, 0.1, 0.25, 0.5 900…7200 120…600 0.1, 0.2, 0.4, 0.8 140G-M0I3-D60 140G-M0I4-D60
630 §  252…630 3, 6, 9, 18 378…6300 0.05, 0.1, 0.25, 0.5 945…7560 126…630 0.1, 0.2, 0.4, 0.8 140G-M0I3-D63 140G-M0I4-D63
800 320…800 3, 6, 9, 18 480…8000 0.05, 0.1, 0.25, 0.5 800…8400 160…800 0.1, 0.2, 0.4, 0.8 140G-M0I3-D80 140G-M0I4-D80
  
§ IEC only.

Electronic LSIG-MM (Long, Short, Instantaneous, Ground Fault - Maintenance Mode)

Click to enlarge - 140G-M6K3-D80 Facing Right


Rated
Current
In [A]
Protection Type Interrupting Code M5 Interrupting Code M6
L S I G Cat. No. Cat. No.
I1=0.4…1 x In t1=sec. I2=1…10 x In t2=sec. I3=1…10 x In I4=0.2…1 x In t4=sec. 3 Poles 4 Poles 3 Poles 4 Poles
600 240…600 3, 6, 9, 18 360…6000 0.05, 0.1, 0.25, 0.5 900…7200 120…600 0.1, 0.2, 0.4, 0.8 140G-M5K3-D60 140G-M5K4-D60 140G-M6K3-D60 140G-M6K4-D60
630 §  252…630 3, 6, 9, 18 378…6300 0.05, 0.1, 0.25, 0.5 945…7560 126…630 0.1, 0.2, 0.4, 0.8 140G-M5K3-D63 140G-M5K4-D63 140G-M6K3-D63 140G-M6K4-D63
800 320…800 3, 6, 9, 18 480…8000 0.05, 0.1, 0.25, 0.5 800…8400 160…800 0.1, 0.2, 0.4, 0.8 140G-M5K3-D80 140G-M5K4-D80 140G-M6K3-D80 140G-M6K4-D80
  
§ IEC only.

Rated
Current
In [A]
Protection Type Interrupting Code M0
L S I G Cat. No.
I1=0.4…1 x In t1=sec. I2=1…10 x In t2=sec. I3=1…10 x In I4=0.2…1 x In t4=sec. 3 Poles 4 Poles
600 240…600 3, 6, 9, 18 360…6000 0.05, 0.1, 0.25, 0.5 900…7200 120…600 0.1, 0.2, 0.4, 0.8 140G-M0K3-D60 140G-M0K4-D60
630 §  252…630 3, 6, 9, 18 378…6300 0.05, 0.1, 0.25, 0.5 945…7560 126…630 0.1, 0.2, 0.4, 0.8 140G-M0K3-D63 140G-M0K4-D63
800 320…800 3, 6, 9, 18 480…8000 0.05, 0.1, 0.25, 0.5 800…8400 160…800 0.1, 0.2, 0.4, 0.8 140G-M0K3-D80 140G-M0K4-D80
  
§ IEC only.

Maintenance Mode (MM)

Maintenance Mode (MM) offers a preset set of protection parameters. MM allows systems testing when the molded case circuit breaker is energized or ON. This feature is a manual adjustment on the molded case circuit breaker, via a DIP switch. The following table illustrates the preset values for Maintenance Mode.

Rated
Current
In [A]
L S I G MM
I1=1 x In t1=MAX sec. I2=OFF t2=OFF sec. I3=4 x In I4=OFF t4=OFF sec. I5=2.5 x In
600 600 18 2400 1500
630 §  630 18 2520 1575
800 800 18 3200 2000
  
§ IEC only.

Molded Case Switch — UL489

Click to enlarge - 140G-M6S3-D80 Facing Right


Rated
Current
In [A]
Magnetic Trip [A]
Im
Cat. No.
3 Poles 4 Poles
800 10 000 140G-M6S3-D80 140G-M6S4-D80
  

Catalog Number Explanation

Complete Circuit Breaker Assemblies — 800 A, M-Frame

Examples given in this section are not intended to be used for product selection. Use ProposalWorks to configure the molded case circuit breaker. These configurations are for selection of all factory-installed options for shunt trips, undervoltage release units, auxiliary contacts, and alarm contacts. Use the codes from Table g to add on to the molded case circuit breaker cat. no. selected on the previous pages to form a complete cat. no. for a complete assembly with factory-installed options.

Click to enlarge - 140G-M6H3-D80 Facing Right


140G M    6    K    3 D60 SD AA
a    b    c    d    e    f    g

a    b    c    d
Bulletin Number Frame/Rating Interrupting Rating/Breaking Capacity
(based on Ic at 480V)
Protection Type
Code Description Code Description Code Description Code Description
140G Global Molded Case Circuit Breaker M 800 A 5 50 kA F Adjust thermal/ adjust magnetic
    6 65 kA H Electronic LSI -long, short, instant
0 100 kA I Electronic LSIG -long, short, instant & ground fault
T Trip unit K Electronic LSIG-MM -long, short, instant, ground fault & MM
  X Breaker frame
        S Molded case switch (isolator)
  
e    f    g    g, cont'd.
Poles Current Range Factory-Installed Internal Options♦  Factory-Installed Internal Options♦ 
Code Description Code Description Shunt Trip and Undervoltage Release Units Auxiliary and Alarm Contacts, Trip Units
Code Description Code Description
3 3 poles D60 e.g., 600 A SJ Shunt Trip, 24…30V AC/DC AA 1 Aux., 1 Alarm Contact, 250V
4 4 poles D63 e.g., 630 A SK Shunt Trip, 48…60V AC/DC CA 3 Aux., 1 Alarm Contact, 250V
  D80 e.g., 800 A SD Shunt Trip, 110…127V AC; 110…125V DC FB 2 Aux. Contacts, 400V
Blank Frame only SA Shunt Trip, 220…240V AC; 220…250V DC AB 1 Aux., 1 Alarm Contact, 400V
  SB Shunt Trip, 380…440V AC CJ 3 Aux., 1 Alarm Contact, 24V
SC Shunt Trip, 480…525V AC  
UJ Undervoltage Release, 24…30V AC/DC
UR Undervoltage Release, 48V AC/DC
UY Undervoltage Release, 60V AC/DC
UD Undervoltage Release, 110…127V AC; 110…125V DC
UA Undervoltage Release, 220…240V AC; 220…250V DC
UB Undervoltage Release, 380…440V AC
UC Undervoltage Release, 480…525V AC
No Digit No Selection
  
♦ Select up to two internal options: 1 for left side mounting (shunt trip or undervoltage release), 1 for right (auxiliary or alarm contact). Consult your local Rockwell automation sales office or Allen-Bradley distributor for further assistance.