Dimensions are in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.

Panel Mounted Molded Case Circuit Breaker

Click to enlarge - 140G_G--panel-mount-dims


‡ Overall dimensions of optional wiring ducts
§ Required 25 mm insulating phase barriers provided


Description No. of Poles A
With flange 3…4 74
Without flange 3…4 71
3…4 79
  

DIN Rail Mounted Molded Case Circuit Breaker

Click to enlarge - 140G_G-DIN-mount-dims


⋆ Mounting bracket
‡ Overall dimensions of optional wiring ducts
§ Required 25 mm insulating phase barriers provided
♣ Optional front cover for DIN Rail


Drilling Template for Molded Case Circuit Breaker Mounting

Click to enlarge - 140G_G-drilling_3poles   Click to enlarge - 140G_G-drilling_4poles   Click to enlarge - 140G_G-drilling_sideview
3 Poles   4 Poles    

Cat. Nos. 140G-G-ECM, -ECM4 Terminals

Click to enlarge - 140G-G-ECM_dims


⋆ Mounting bracket
♠ Required 25 mm insulating phase barriers provided


Cat. Nos. 140G-G-EXT3, -EXT4 Extended Terminals

Click to enlarge - 140G-G-EXT_dims


‡ Extended terminals
§ Optional Terminal covers with IP40 protection provided
∆ Required 100 mm insulating phase barriers provided
▶ Internal insulating plate required with phase barriers (customer provided) when mounted through the enclosure door


Cat. Nos. 140G-G-EXS3, -EXS4 Spreader Terminals

Click to enlarge - 140G-G-EXS_dims


♣ Extended spread terminals for busbar connection
♦ Required 200 mm insulating phase barriers provided


Cat. Nos. 140G-G-TLC13, 140G-G-TLC14 Terminals (Copper Only Lug)

Click to enlarge - 140G-G-terminal3_dims


‡ Front terminals


Cat. No. 140G-G-MTL63, -MTL64 Terminal (Multi-Cable Terminal Lug)

Click to enlarge - 140G-G-terminal4_dims


♣ Required terminal covers with IP40 protection provided
∆ Terminal lugs for multi-cable connection


Cat. No. 140G-G-RMB or 140G-G-RMY Direct Rotary Operating Handle

Click to enlarge - 140G-G-RMB_RMY_dims


‡ Rotary handle operating mechanism on molded case circuit breaker
♣ Door drilling template with direct rotary handle
♦ Required 25 mm insulating phase barriers provided


Cat. No. 140G-G-EOP… Motor Operator

Click to enlarge - 140G-G-EOP_dims


♣ Motor operator
∆ Door drilling template (without flange)
♦ Door drilling template (with flange)
♠ Cable connection
▶ Required 25 mm insulating phase barriers provided


Cat. No. 140G-G-ELP1603 Residual Current Release Module for 3-Pole Molded Case Circuit Breakers

Click to enlarge - 140G-G-ELP1603_dims


Description No. of Poles A
With flange 3 74
Without flange 3 71
  

⋆ Terminals for busbar connection
‡ IP40 terminal covers
§ Drilling template — door with direct rotary mechanism and flange
♣ Drilling template — door with direct rotary mechanism, without flange
∆ Drilling template — molded case circuit breaker mounting on mounting plate


Cat. No. 140G-G-ELP1604 Residual Current Release Module for 4-Pole Molded Case Circuit Breakers

Click to enlarge - 140G-G-ELP1604_dims


Description No. of Poles A
With flange 4 74
Without flange 4 71
  

⋆ Terminals for busbar connection
‡ IP40 terminal covers
§ Drilling template — door with direct rotary mechanism and flange
♣ Drilling template — door with direct rotary mechanism, without flange
∆ Drilling template — molded case circuit breaker mounting on mounting plate


Dimensions are in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.

Panel Mounted Molded Case Circuit Breaker

Click to enlarge - 140G_H-panel-mount-dims


‡ Overall dimensions of optional wiring ducts
§ Required 25 mm insulating phase barriers provided


Description No. of Poles A
With flange 3…4 86
Without flange 3…4 83.5
3…4 91.5
  

DIN Rail Mounted Molded Case Circuit Breaker

Click to enlarge - 140G_H-DIN-mount-dims


⋆ Mounting bracket
§ Required 25 mm insulating phase barriers provided


Drilling Template for Molded Case Circuit Breaker Mounting

Click to enlarge - 140G_H-drilling_3poles   Click to enlarge - 140G_H-drilling_4poles   Click to enlarge - 140G_H-drilling_sideview
3 Poles   4 Poles    

Cat. Nos. 140G-H-ECM, -ECM4 Terminals

Click to enlarge - 140G_H-ECM-dims


⋆ Required 25 mm insulating phase barriers provided
‡ Front terminals for busbar connection


Cat. Nos. 140G-H-EXT3, -EXT4 Extended Terminals

Click to enlarge - 140G_H-EXT-dims


§ Extended terminals
♣ Optional terminal covers with IP40 protection provided
∆ Required 100 mm insulating phase barriers provided
♦ Required internal insulating plate provided for breakers with Ue>440V
♠ Drilling template for 3-pole molded case circuit breaker, Ue>440V (required)
▶ Drilling template for 4-pole molded case circuit breaker, Ue>440V (required)


Cat. Nos. 140G-H-EXS3, -EXS4 Spreader Terminals

Click to enlarge - 140G_H-EXS-dims


Click to enlarge - 140G_H-EXS-drillingdims_4poles   Click to enlarge - 140G_H-EXS-drillingdims_3poles
4 Poles   3 Poles

⋆ Drilling template for 3-pole molded case circuit breaker, Ue>440V (required)
‡ Drilling template for 4-pole molded case circuit breaker, Ue>440V (required)
§ Extended spread terminals
♣ Required 200 mm insulating phase barriers provided
∆ Required insulated plate provided for breakers, with Ue>440V


Cat. Nos. 140G-H-TLC13, -TLC14 Terminals

Click to enlarge - 140G_H-TLC-dims


§ Required 25 mm insulating phase barriers provided
♦ Copper terminals.


Cat. Nos. 140G-H-MTL63, -MTL64 Terminals

Click to enlarge - 140G_H-MTL6-dims


♦ Multi-cable terminals


Cat. No. 140G-H-RMB, -RMY Direct Rotary Operating Handle

Click to enlarge - 140G-H-RMB_RMY-dims


‡ Rotary handle operating mechanism on molded case circuit breaker
♦ Required 25 mm insulating phase barriers provided


Click to enlarge - 140G-H-RMX


Cat. No. 140G-H-EOP… Motor Operator

Click to enlarge - 140G_H-EOP-dims


⋆ Motor operator
∆ Drilling template for 3-pole molded case circuit breaker, mounted on mounting plate
♦ Drilling template for 4-pole molded case circuit breaker, mounted on mounting plate
♠ Required 25 mm insulating phase barriers provided


Cat. No. 140G-H-ELP1604 Residual Current Release Module

Click to enlarge - 140G_H-ELP1604-dims


Description No. of Poles A
With flange 4 86
Without flange 4 83.5
  

⋆ Residual current module
‡ Front terminals
♠ Drilling template — door with direct rotary mechanism and flange
▶ Drilling template — door with direct rotary mechanism, without flange
& Drilling template — molded case circuit breaker mounting on mounting plate


Dimensions are in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.

Panel Mounted Molded Case Circuit Breaker

Click to enlarge - 140G_I-panel-mount-dims


‡ Overall dimensions of optional wiring ducts
§ Required 25 mm insulating phases barriers provided


Description No. of Poles A
With flange 3…4 74
Without flange 3…4 71
3…4 79
  

DIN Rail Mounted Molded Case Circuit Breaker

Click to enlarge - 140G_I-DIN-mount-dims


⋆ Mounting bracket
‡ Optional wiring ducts
§ Optional front cover for DIN Rail
♣ Required 25 mm insulating phase barriers provided


Drilling Template for Molded Case Circuit Breaker Mounting

Click to enlarge - 140G_I-drilling_3poles   Click to enlarge - 140G_I-drilling_4poles   Click to enlarge - 140G_I-drilling_sideview
3 Poles   4 Poles    

Cat. Nos. 140G-I-ECM, -ECM4 Terminals

Click to enlarge - 140G-I-ECM-dims


⋆ Front terminals for busbar connection
‡ Required 25 mm insulating phase barriers provided


Cat. Nos. 140G-J-EXS3, -EXS4 Terminals

Click to enlarge - 140G-I-terminal_1-dims


♣ Extended spread terminals
♦ Required 200 mm insulating phase barriers provided


Cat. Nos. 140G-I-EXT3, -EXT4 Extended Terminals

Click to enlarge - 140G-I-EXT-dims


‡ Extended terminals
§ Optional terminal covers with IP40 protection provided
∆ Required 100 mm insulating phase barriers provided


Cat. Nos. 140G-I-TLA1A3, -TLA1A4 Terminals

Click to enlarge - 140G-I-TLA3-4-dims


⋆ 30…150 mm2 terminals
‡ Required 25 mm insulating phase barriers provided


Cat. Nos. 140G-I-TLA3, -TLA4 Terminals

Click to enlarge - 140G-I-TLA13-14-dims


⋆ 1x90…185 mm2 terminal
§ Required 25 mm insulating phase barriers provided


Cat. Nos. 140G-I-TLC13, -TLC14 Terminals

Click to enlarge - 140G-I-TLC13-14-dims


♦ Front terminals
& Required 25 mm insulating phase barriers provided


Cat. Nos. 140G-I-MTL63, -MTL64 Terminals

Click to enlarge - 140G-I-MTLA63-64-dims


§ Optional terminal covers with IP40 protection provided
∆ Multi-cable terminal lugs


Cat. No. 140G-G-RMB, -RMY Direct Rotary Operating Handle (For I- and G-Frame Molded Case Circuit Breaker)

Click to enlarge - 140G-G-RMB_RMY_I-frame


‡ Rotary handle operating mechanism on molded case circuit breaker
♣ Door drilling template with direct rotary handle
♦ Required 25 mm insulating phase barriers provided


Cat. No. 140G-G-EOP… Motor Operator (I-Frame)

Click to enlarge - 140G-I-EOP-dims


♣ Motor operator
♠ Required 25 mm insulating phase barriers provided


Cat. No. 140G-I-ELP2503 Residual Current Release Module

Click to enlarge - 140G-I-ELP2503-dims


Description No. of Poles A
With flange 3 74
Without flange 3 71
  

⋆ Terminals for cable connection
‡ Terminal covers with IP40 protection
∆ Drilling template — molded case circuit breaker mounting on mounting plate


Cat. No. 140G-I-ELP2504 Residual Current Release Module for 4-Pole Molded Case Circuit Breakers

Click to enlarge - 140G-I-ELP2504-dims


Description No. of Poles A
With flange 4 74
Without flange 4 71
  

⋆ Terminals for busbar connection
‡ Terminal covers with IP40 protection
∆ Drilling template — molded case circuit breaker mounting on mounting plate


Dimensions are in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.

Panel Mounted Molded Case Circuit Breaker

Click to enlarge - 140G_J-panel_mount


‡ Overall dimensions of optional wiring ducts.
§ Required 25 mm insulating phase barriers provided.


Description No. of Poles A
With flange 3…4 86
Without flange 3…4 83.5
3…4 91.5
  

DIN Rail Mounted Molded Case Circuit Breaker

Click to enlarge - 140G_J-DIN_mount


⋆ Mounting bracket
§ Required 25 mm insulating phase barriers provided


Drilling Template for Molded Case Circuit Breaker Mounting

Click to enlarge - 140G_J-drilling_3poles   Click to enlarge - 140G_J-drilling_4poles   Click to enlarge - 140G_J-drilling_sideview
3 Poles   4 Poles    

Cat. Nos. 140G-J-ECM, -ECM4 Terminals

Click to enlarge - 140G-J-ECM-4_dims


⋆ Required 25 mm insulating phase barriers provided
‡ Terminals for busbar connection


Cat. Nos. 140G-J-EXT3, -EXT4 Extended Terminals

Click to enlarge - 140G-J-EXT3-4_dims


§ Extended terminals
♣ Optional terminal covers with IP40 protection provided
∆ Required 100 mm insulating phase barriers provided
♦ Required insulating plate provided for molded case circuit breaker with Ue>440V
♠ Drilling template for 3-pole molded case circuit breaker
▶ Drilling template for 4-pole molded case circuit breaker


Cat. Nos. 140G-J-EXS3, -EXS4 Spreader Terminals

Click to enlarge - 140G-J-EXS3-4_dims


⋆ Drilling template for 3-pole molded case circuit breaker
‡ Drilling template for 4-pole molded case circuit breaker
§ Extended spread terminals
♣ Required 200 mm insulating phase barriers provided
∆ Required insulated plate provided for molded case circuit breaker with Ue>440V


Cat. Nos. 140G-J-TLA13, -TLA14 Terminal Lugs

Aluminum Conductor: 6…350 MCM (2.5…185 mm)
Copper Conductor: 10…350 MCM (6…185 mm)


Click to enlarge - 140G-J-TLA13-14_dims


⋆ 1x1…185 mm2 front terminal
§ Required 25 mm insulating phase barriers provided


Cat. Nos. 140G-J-TLC13, -TLC14 Terminal Lugs

10…350 MCM (6…185 mm)

Click to enlarge - 140G-J-TLC13-14_dims


⋆ External terminals
♣ Required 25 mm insulating phase barriers provided


Cat. Nos. 140G-J-MTL63, -MTL64 Terminals

Click to enlarge - 140G-J-MTL63-64_dims


‡ Multi-cable terminal lugs
§ Optional terminal covers with IP40 protection provided


Cat. No. 140G-H-RMB, -RMY Direct Rotary Operating Handle (For H- and J-Frame Molded Case Circuit Breaker)

Click to enlarge - 140G-H-RMB_RMY-dims


‡ Rotary handle operating mechanism on molded case circuit breaker
♦ Required 25 mm insulating phase barriers provided


Click to enlarge - 140G-H-RMB_RMY_DrillTemplate
Flange Mount Drill Template


Cat. No. 140G-H-EOP… Motor Operator – For H- & J-Frame Molded Case Circuit Breaker

Click to enlarge - 140G-H-EOP_J-frame


⋆ Motor operator
§ Drilling template for door with motor operator with flange
♣ Drilling template for door with motor operator without flange
∆ Drilling template for 3-pole molded case circuit breaker, mounted on mounting plate
♦ Drilling template for 4-pole molded case circuit breaker, mounted on mounting plate
♠ Required 25 mm insulating phase barriers provided


Cat. No. 140G-J-EP2504 Residual Current Release Module for 4-Pole Molded Case Circuit Breakers

Click to enlarge - 140G-J-EP2504_dims


Description No. of Poles A
With flange 4 86
Without flange 4 83.5
  

⋆ Residual current module
‡ Front terminals
♠ Drilling template — door with direct rotary mechanism and flange
▶ Drilling template — door with direct rotary mechanism, without flange
& Drilling template — molded case circuit breaker mounting on mounting plate


Dimensions are in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.

Panel Mounted Molded Case Circuit Breaker

Click to enlarge - 140G-K_panel mount


⋆ Overall dimensions with cabled accessories mounted
‡ Overall dimensions with cabled auxiliary contacts mounted


Drilling Templates for Molded Case Circuit Breaker Mounting

Flange for compartment door

Click to enlarge - 140G-K_flange


Drilling template for compartment door

Click to enlarge - 140G-K_drill_door_flange   Click to enlarge - 140G-K_drill_door_noflange
with flange
(3…4 poles)
  without flange
(3…4 poles)

Drilling template for mounting plate

Click to enlarge - 140G-K-IBP3_dims
3 Poles


Click to enlarge - 140G-K-IBP4_dims
4 Poles


Cat. Nos. 140G-K-ECM, -ECM4 Terminals

Click to enlarge - 140G-K-ECM_ECM4


Cat. Nos. 140G-K-TLC13, -TLC14 Terminals

250…500 MCM (120…240 mm2)

Click to enlarge - 140G-K-TLC13_14


Cat. Nos. 140G-K-TLA23, -TLA24, -TLC23, -TLC24 Terminals

(2) 2/0…250 MCM ((2) 95…120 mm2)

Click to enlarge - 140G-K-TLA23_24


⋆ Terminal covers with IP40 protection


Cat. Nos. 140G-K-TLA13, -TLA14 Terminals

250…500 MCM (120…240 mm2)

Click to enlarge - 140G-K-TLA13_14_dims


Cat. Nos. 140G-K-EXT3, -EXT4 Extended Terminals

Click to enlarge - 140G-K-EXT3_4


⋆ Terminal covers with IP40 protection
‡ Required 100 mm insulating phase barriers provided


Cat. Nos. 140G-K-EXS3, -EXS4 Spreader Terminals

Click to enlarge - 140G-K-EXS3_4


⋆ Required 200 mm insulating phase barriers provided


Cat. No. 140G-K-RMB, -RMY Rotary Handle Operating Mechanism — Door Mounted

Click to enlarge - 140G-K-RMB_RMY


⋆ Rotary handle operating mechanism on molded case circuit breaker
‡ Padlock device for open position (max. 3 padlocks; user provided)
§ Dimensions with cabled early make contact
♣ Compartment door lock


Cat. No. 140G-K-ELP Residual Current Release Module for 4-Pole Molded Case Circuit Breakers

Click to enlarge - 140G-K-ELP


⋆ Overall dimensions with cabled auxiliary contacts mounted


Dimensions are in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.

Panel Mounted Molded Case Circuit Breaker

Click to enlarge - 140G-M_panel


⋆ Overall dimensions with cabled accessories mounted
‡ Overall dimensions with cabled auxiliary contacts mounted


Drilling Templates for Molded Case Circuit Breaker Mounting

Flange for compartment door

Click to enlarge - 140G-M_flange


Drilling template for compartment door

Click to enlarge - 140G-M_drill_door_flange   Click to enlarge - 140G-M_drill_door_noflange
with flange   without flange

Drilling template for mounting plate

Click to enlarge - 140G-M_plate_drill_3poles
3 Poles


Click to enlarge - 140G-M_plate_drill_4poles
4 Poles


Cat. No. 140G-M-ECM Terminals

Click to enlarge - 140G-M-ECM


Cat. No. 140G-M-TLA23, -TLA24, -TLC23, -TLC24 Terminals

Click to enlarge - 140G-M-TLA33


Cat. Nos. 140G-M-EXT3, -EXT4 Extended Terminals

Click to enlarge - 140G-M-EXT3_4


Cat. Nos. 140G-M-EXSLI3, -EXSLO3, -EXS4 Spreader Terminals

Click to enlarge - 140G-M-EXS


Cat. No. 140G-M-RMB, -RMY Rotary Handle Operating Mechanism — Door Mounted

Click to enlarge - 140G-M-RMB_RMY


⋆ Rotary handle operating mechanism on molded case circuit breaker
‡ Padlock device for open position (max. 3 padlocks; user provided)
§ Dimension with cabled early make contact
♣ Compartment door lock


Flange for compartment door

Click to enlarge - 140G-M-RMB_flange


Drilling template for compartment door

Click to enlarge - 140G-M-RMB_drill_door_flange   Click to enlarge - 140G-M-RMB_drill_door_noflange
with flange   without flange

Cat. No. 140G-M-EOP, -ECOP Motor Operator

Click to enlarge - 140G-M-EOP_ECOP


⋆ Overall dimension with cabled accessories mounted
‡ Overall dimension with cabled auxiliary contacts mounted


Flange for compartment door

Click to enlarge - 140G-M-EOP_flange


Drilling template for compartment door

Click to enlarge - 140G-M-EOP_drill_door_flange   Click to enlarge - 140G-M-EOP_drill_door_noflange
with flange   without flange

Drilling template for mounting plate

Click to enlarge - 140G-M-EOP_plate_drill


Dimensions are in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.

Panel Mounted Molded Case Circuit Breaker

Click to enlarge - 140G-N_panel


⋆ Front terminals for flat connection
‡ Busbars
§ Door flange
∆ Tightening torque: 18 N•m
♠ Padlock (optional)
▶ Tightening torque: 2.5 N•m
& Terminal for auxiliary contacts


Description A
With flange 125…141
Without flange 147
  

Drilling Templates for Molded Case Circuit Breaker Mounting

Flange for compartment door

Click to enlarge - 140G-N_flange


§ Door flange
# Reduced flange for compartment door


Drilling template for compartment door

Click to enlarge - 140G-N_drill_door_reducedflange   Click to enlarge - 140G-N_drill_door_front190x105
with reduced flange   Front 190 x 105
     
Click to enlarge - 140G-N_drill_door_flange   Click to enlarge - 140G-N_drill_door_front206x204
with flange   Front 206 x 204

Drilling template for mounting plate

Click to enlarge - 140G-N_plate_drill


No. of Poles C
3 70
4 140
  

Cat. Nos. 140G-N-TLH3, -TLV3, TLH4, TLV4 Terminals

Click to enlarge - 140G-N-TLH_V


⋆ Rear horizontal terminals
‡ Rear vertical terminals
♠ Tightening torque: 20 N•m


Drilling template for mounting plate

Click to enlarge - 140G-N-TL_drill


No. of Poles B C
3 70 192.5
4 140 262.5
  

Cat. No. 140G-N-EXT3, -EXT4 Extended Front Terminals

Click to enlarge - 140G-N-EXT3_4


⋆ Extended terminals
▶ Required 100 mm insulating phase barriers provided
♠ Tightening torque: 18 N•m
& Required insulating plate provided for molded case circuit breaker


Cat. Nos. 140G-N-EXSL13 Top (3-Pole), 140G-N-EXS4 (4-Pole) Rear Spread Terminals

Click to enlarge - 140G-N-EXS3


‡ Extended spread terminals
# Required 200 mm insulating phase barriers provided
♠ Tightening torque: 18 N•m
§ Terminal for auxiliary contacts
& Required insulating plate provided for molded case circuit breaker


Cat. No. 140G-N-RMB, -RMY Rotary Handle Operating Mechanism

Click to enlarge - 140G-N-RMB_RMY


⋆ Rotary handle operating mechanism on molded case circuit breaker
‡ Compartment door interlock
§ Door flange
♦ Tightening torque: 2.5 N•m
♠ Terminal for auxiliary contacts
▶ Reduced flange of rotary handle for door (optional)


Description A
With flange 125…141
Without flange 147
  

Cat. No. 140G-N-TLA43, -TLA44, -TLC43, -TLC44 Terminals

Click to enlarge - 140G-N-TLA43_44


⋆ Terminal lugs for cables
‡ Tightening torque: 43 N•m
♠ Tightening torque: 18 N•m
▶ Required insulating plate provided for molded case circuit breaker


Dimensions are in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.

Panel Mounted Molded Case Circuit Breaker

Click to enlarge - 140G-NS_breaker


⋆ Front terminals for busbar connection
‡ Busbars
§ Door flange
∆ Drilling template for fixing onto mounting plate
♦ Tightening torque: 18 N•m
♠ Key lock (optional)
▶ Padlock (optional)
& Tightening torque: 2.5 N•m
# Compartment door with flange sheet drilling
※ Compartment door without flange sheet drilling
∇ Terminal for auxiliary contacts


Description A
With flange 125…184 (4.92…7.24)
Without flange 170 (6.7)
 
Description B
Standard 208 (8.19)
 
No. of Poles C
3 70 (2.76)
4 140 (5.51)
  

Drilling Templates for Molded Case Circuit Breaker Mounting

Click to enlarge - 140G-NS_drilling_CompartmentDoor_template   Click to enlarge - 140G-NS_drilling_CompartmentDoor_Flange   Click to enlarge - 140G-NS_drilling_MountingPlate_template
Drilling template for compartment door   Flange for compartment door   Drilling template for mounting plate

Cat. Nos. 140G-N-TLA63, -TLA64, -TLC63, -TLC64 Terminals

Click to enlarge - 140G-N-TL_63-64


⋆ Front terminals for cables
‡ Tightening torque: 43 N•m
♠ Tightening torque: 18 N•m
▶ Required insulating plates provided for molded case circuit breaker


Cat. Nos. 140G-N-TLV3, -TLV4, -TLH3, -TLH4 Rear Terminals

Click to enlarge - 140G-N-TLV-H_3-4


⋆ Rear horizontal terminals
‡ Rear vertical terminals
♠ Tightening torque: 20 N•m


Drilling template for mounting plate

Click to enlarge - 140G-N-TLV-H_3-4_drill


No. of Poles B C
3 70 (2.76) 192.5 (7.58)
4 140 (5.51) 262.5 (10.33)
  

Cat. No. 140G-N-EXSLI3, -EXSL03, -EXS4 Extended Front Spreader Terminals

Click to enlarge - 140G-N-EXS_NS


⋆ Extended spread terminals
‡ Tightening torque: 18 N•m
§ Required 200 mm insulating phase barriers provided
∆ Required insulating plate provided


Cat. Nos. 140G-N-EXT3, -EXT4 Extended Front Terminals

Click to enlarge - 140G-N-EXT_NS


‡ Tightening torque: 18 N•m
♣ Required insulating plate provided
∆ Extended terminals
♦ Required 100 mm insulating phase barriers provided
♠ Terminal for auxiliary contacts


Dimensions are in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.

Panel Mounted Breakers

2500 A Breakers

Click to enlarge - 140G-R_breaker


Drilling Templates

Click to enlarge - 140G-R_breaker_drill-4poles   Click to enlarge - 140G-R_breaker_drill-3poles
Mounting Plate
(4 Poles)
  Mounting Plate
(3 Poles)

3000 A Breakers

Click to enlarge - 140G-R-3000_breaker


Drilling Templates

Click to enlarge - 140G-R-3000_breaker_Drill-4pole   Click to enlarge - 140G-R-3000_breaker_Drill-3pole   Click to enlarge - 140G-R-BC12
Mounting Plate
(4 Poles)
  Mounting Plate
(3 Poles)
  Compartment Door

Drilling template for compartment door

Click to enlarge - 140G-R-BC12