Molded Case Circuit Breakers

Catalogs > Industrial Controls Catalog > Motor Control, IEC > Molded Case Circuit Breakers > Bulletin 140U Product Line Overview

Bulletin 140U Product Line Overview

Introduction Standards Compliance and Certifications Catalog Number Explanation
Catalog Number Explanation

Examples given in this section are for reference purposes. This basic explanation should not be used for product selection; not all combinations will produce a valid cat. no. Refer to the tables on the following pages for descriptions of options.

Complete Circuit Breaker Assemblies

140U H    6    C    3 C50 H      
a    b    c    d    e    f    g    h

a    b    c    d
Bulletin Number Frame/Rating Interrupting Rating / Breaking Capacity Protection Type
Code Description Code Description Code Description Code Description
140U Molded Case Circuit Breaker H 125 A 2 20…29 kA C Fixed Thermal/Fixed Magnetic
  J 250 A 3 30…39 kA D Fixed Thermal/Adjust Magnetic
K 400 A 5 50…59 kA E Adjust Thermal/Fixed Magnetic
L 600 A 6 60…69 kA F Adjust Thermal/Adjust Magnetic
M 800 A 8 80…89 kA G Electronic (LSG — Long, short,
ground fault)
N 1200 A 0 ³100 kA H Electronic (LSI — Long, short,
high instant)
    I Electronic (LSIG — Long, short,
high instant, ground fault)
L Electronic (LS — Long and Short time)
S Molded Case Switch (Isolator)
  
e    f    g    h
Poles Current Range Internal Control Modules Voltage Code
Code Description Code Description Code Description See the following for voltage code descriptions:
1 1 poles C 10 rr. A A 1 Auxiliary contact All frame sizes Internal Control Modules — Factory Installed
For use with H-, J-, K-, L-, M-, and N-Frame Molded Case Circuit Breakers
2 2 poles D 100 rr0 A B 2 Auxiliary contacts  
3 3 poles E 1000 rr00 A D 1 Alarm contact
    F 1 Auxiliary + 1 Alarm contact
G Undervoltage release only
P Shunt trip only
Control Module Combinations
Code Description
H 1 Auxiliary contact + undervoltage release
J 2 Auxiliary contacts + undervoltage release
L 1 Auxiliary + 1 Alarm contact + undervoltage release
N 1 Alarm contact + undervoltage release
Q 1 Auxiliary contact + shunt trip
R 2 Auxiliary contacts + shunt trip
T 1 Auxiliary + 1 Alarm contact + shunt trip
V 1 Alarm contact + shunt trip

Examples given in this section are for reference purposes. This basic explanation should not be used for product selection; not all combinations will produce a valid cat. no. Refer to the tables on the following pages for descriptions of options.

Frames

140U J    3    X    3
a    b    c    d    e

a    b    c    d
Bulletin Number Frame/Rating Interrupting Rating / Breaking Capacity Protection Type
Code Description Code Description Code Description Code Description
140U Molded Case Circuit Breaker J 250 A 2 20…29 kA X Frame Only
  K 400 A 3 30…39 kA  
Q 600 A 5 50…59 kA
M 800 A 6 60…69 kA
  8 80…89 kA
0 ³100 kA
  
e     
Poles
Code Description
3 3 poles

Trip Units

140U J    T    D    3 D25
a    b    c    d    e    f

a    b    c    d
Bulletin Number Frame/Rating Trip Unit Protection Type
Code Description Code Description Code Description Code Description
140U Molded Case Circuit Breaker J 250 A T Trip Unit C Fixed Thermal/Fixed Magnetic
  K 400 A   D Fixed Thermal/Adjust Magnetic
L 600 A E Adjust Thermal/Fixed Magnetic
M 800 A F Adjust Thermal/Adjust Magnetic
  G Electronic (LSG — Long, short,
ground fault)
H Electronic (LSI — Long, short,
high instant)
I Electronic (LSIG — Long, short,
high instant, ground fault)
L Electronic (LS — Long and Short time)
S Molded Case Switch (isolator)
  
e    f     
Poles Current Range
Code Description Code Description
3 3 poles C 10 rr. A
  D 100 rr0 A
E 1000 rr00 A