Catalogs > Industrial Controls Catalog > Motor Control, IEC > Molded Case Circuit Breakers > Bulletin 140U Product Line Overview
Bulletin 140U Product Line Overview
Examples given in this section are for reference purposes. This basic explanation should not be used for product selection; not all combinations will produce a valid cat. no. Refer to the tables on the following pages for descriptions of options.Complete Circuit Breaker Assemblies
| 140U | | H | 6 | C | 3 | | C50 | | H | |||||
| a | b | c | d | e | f | g | h |
| a | b | c | d | |||||||
| Bulletin Number | Frame/Rating | Interrupting Rating/Breaking Capacity (based on Ic at 480V) |
Protection Type | |||||||
| Code | Description | Code | Description | Code | Description | Code | Description | |||
| 140U | Molded Case Circuit Breaker | D | 30 A | 2 | 20…29 kA | C | Fixed thermal/fixed magnetic | |||
| G | 100 A | 3 | 30…39 kA | D | Fixed thermal/adjust magnetic | |||||
| H | 125 A | 5 | 50…59 kA | E | Adjust thermal/fixed magnetic | |||||
| J | 250 A | 6 | 60…69 kA | F | Adjust thermal/adjust magnetic | |||||
| K | 400 A | 8 | 80…89 kA | G | Electronic (LSG — long, short, ground fault) |
|||||
| L | 600 A | 0 | ³100 kA | H | Electronic (LSI — long, short, high instant) |
|||||
| M | 800 A | I | Electronic (LSIG — long, short, high instant, ground fault) |
|||||||
| N | 1200 A | J | Electronic (LSII — long, short, high instant, instantaneous maintenance mode) |
|||||||
| R | 2500 A | K | Electronic (LSIIG — long, short, high instant, instantaneous maintenance mode, ground fault) |
|||||||
| L | Electronic (LS — long and short time) | |||||||||
| S | Molded case switch (Isolator) | |||||||||
| e | f | g | h | |||||||
| Poles | Current Range | Internal Control Modules | Voltage Code | |||||||
| Code | Description | Code | Description | Code | Description | See the following for voltage code descriptions: | ||||
| 1 | 1 poles | C | 10 rr. A | A | 1 auxiliary contact | All frame sizes Internal Control Modules — Factory Installed For use with H-, J-, K-, L-, M-, and N-Frame Molded Case Circuit Breakers |
||||
| 2 | 2 poles | D | 100 rr0 A | B | 2 auxiliary contacts | |||||
| 3 | 3 poles | E | 1000 rr00 A | D | 1 alarm contact | |||||
| F | 1 auxiliary + 1 alarm contact | |||||||||
| G | Undervoltage release only | |||||||||
| P | Shunt trip only | |||||||||
| Control Module Combinations | ||||||||||
| Code | Description | |||||||||
| H | 1 auxiliary contact + undervoltage release | |||||||||
| J | 2 auxiliary contacts + undervoltage release | |||||||||
| L | 1 auxiliary + 1 alarm contact + undervoltage release | |||||||||
| N | 1 alarm contact + undervoltage release | |||||||||
| Q | 1 auxiliary contact + shunt trip | |||||||||
| R | 2 auxiliary contacts + shunt trip | |||||||||
| T | 1 auxiliary + 1 alarm contact + shunt trip | |||||||||
| V | 1 alarm contact + shunt trip | |||||||||
Examples given in this section are for reference purposes. This basic explanation should not be used for product selection; not all combinations will produce a valid cat. no. Refer to the tables on the following pages for descriptions of options.
Frames
| 140U | | J | 3 | X | 3 | |||
| a | b | c | d | e |
| a | b | c | d | |||||||
| Bulletin Number | Frame/Rating | Interrupting Rating / Breaking Capacity | Protection Type | |||||||
| Code | Description | Code | Description | Code | Description | Code | Description | |||
| 140U | Molded Case Circuit Breaker | J | 250 A | 2 | 20…29 kA | X | Frame Only | |||
| K | 400 A | 3 | 30…39 kA | |||||||
| Q | 600 A | 5 | 50…59 kA | |||||||
| M | 800 A | 6 | 60…69 kA | |||||||
| 8 | 80…89 kA | |||||||||
| 0 | ³100 kA | |||||||||
| e | ||||||||||
| Poles | ||||||||||
| Code | Description | |||||||||
| 3 | 3 poles | |||||||||
Trip Units
| 140U | | J | T | D | 3 | | D25 | |||
| a | b | c | d | e | f |
| a | b | c | d | |||||||
| Bulletin Number | Frame/Rating | Trip Unit | Protection Type | |||||||
| Code | Description | Code | Description | Code | Description | Code | Description | |||
| 140U | Molded Case Circuit Breaker | J | 250 A | T | Trip unit | C | Fixed thermal/fixed magnetic | |||
| K | 400 A | D | Fixed thermal/adjust magnetic | |||||||
| L | 600 A | E | Adjust thermal/fixed magnetic | |||||||
| M | 800 A | F | Adjust thermal/adjust magnetic | |||||||
| G | Electronic (LSG — long, short, ground fault) |
|||||||||
| H | Electronic (LSI — long, short, high instant) |
|||||||||
| I | Electronic (LSIG — long, short, high instant, ground fault) |
|||||||||
| J | Electronic (LSII — long, short, high instant, instantaneous maintenance mode) |
|||||||||
| K | Electronic (LSIIG — long, short, high instant, instantaneous maintenance mode, ground fault) |
|||||||||
| L | Electronic (LS — long and short time) | |||||||||
| S | Molded case switch (Isolator) | |||||||||
| e | f | |||||||||
| Poles | Current Range | |||||||||
| Code | Description | Code | Description | |||||||
| 3 | 3 poles | C | 10 rr. A | |||||||
| D | 100 rr0 A | |||||||||
| E | 1000 rr00 A | |||||||||