Bulletin 140U J-Frame

Product Selection — 250 A, J-Frame

Click to enlarge - 140U-39-3



Note: Terminal box lugs must be ordered separately. See External Accessories

Breaker Frames

Rated
Current
In [A]
Breaking Capacity (50 Hz)
Icu /Ics [kA]
Interrupting Rating (60 Hz)
[kA]
Cat. No.
220…240V 380…415V 525V 690V 240V 480V 600V
250 65 65 25 25 18 12 12 6 65 25 18 140U-J2X3
85 85 45 45 18 12 12 6 85 35 18 140U-J3X3
100 100 70 70 25 13 14 7 100 65 25 ‡  140U-J6X3
200 200 100 100 35 18 16 12 200 100 35 ‡  140U-J0X3
  
‡ Current Limiting

Trip Units

Thermal-Magnetic
Rated Current In [A] Adjustment Range [A] Cat. No.
Thermal Trip
Ir = In (Fixed)
Magnetic Trip
Im = 5…10 x Ir
90 90 450…900 140U-JTD3-C90
100 100 500…1000 140U-JTD3-D10
125 125 600…1250 140U-JTD3-D12
150 150 750…1500 140U-JTD3-D15
175 175 875…1750 140U-JTD3-D17
200 200 1000…2000 140U-JTD3-D20
225 225 1125…2250 140U-JTD3-D22
250 250 1250…2500 140U-JTD3-D25
  

Electronic
Rated Current In [A] Adjustment Range [A] Protection Type Cat. No.
Thermal Trip
Ir = 0.4…1.0 x In
Magnetic Trip
Im = 2…14 x Ir
50 20…50 40…700 LS 140U-JTL3-C50
50 20…50 40…700 LSI 140U-JTH3-C50
50 20…50 40…700 LSG 140U-JTG3-C50
50 20…50 40…700 LSIG 140U-JTI3-C50
100 40…100 80…1400 LS 140U-JTL3-D10
100 40…100 80…1400 LSI 140U-JTH3-D10
100 40…100 80…1400 LSG 140U-JTG3-D10
100 40…100 80…1400 LSIG 140U-JTI3-D10
160 63…160 126…2240 LS 140U-JTL3-D16
160 63…160 126…2240 LSI 140U-JTH3-D16
160 63…160 126…2240 LSG 140U-JTG3-D16
160 63…160 126…2240 LSIG 140U-JTI3-D16
250 100…250 200…3500 LS 140U-JTL3-D25
250 100…250 200…3500 LSI 140U-JTH3-D25
250 100…250 200…3500 LSG 140U-JTG3-D25
250 100…250 200…3500 LSIG 140U-JTI3-D25
  

Assembled Circuit Breakers with Thermal-Magnetic Trip Units

Rated Current In [A] Breaking Capacity/
Interrupting Rating [kA]T 
Cat. No. Breaking Capacity/
Interrupting Rating [kA]T 
Cat. No. Breaking Capacity/
Interrupting Rating [kA]T 
Cat. No.
400V 480V 400V 480V 400V 480V
90 25 25 140U-J2D3-C90 40 35 140U-J3D3-C90 70 65 140U-J6D3-C90
100 25 25 140U-J2D3-D10 40 35 140U-J3D3-D10 70 65 140U-J6D3-D10
125 25 25 140U-J2D3-D12 40 35 140U-J3D3-D12 70 65 140U-J6D3-D12
150 25 25 140U-J2D3-D15 40 35 140U-J3D3-D15 70 65 140U-J6D3-D15
175 25 25 140U-J2D3-D17 40 35 140U-J3D3-D17 70 65 140U-J6D3-D17
200 25 25 140U-J2D3-D20 40 35 140U-J3D3-D20 70 65 140U-J6D3-D20
225 25 25 140U-J2D3-D22 40 35 140U-J3D3-D22 70 65 140U-J6D3-D22
250 25 25 140U-J2D3-D25 40 35 140U-J3D3-D25 70 65 140U-J6D3-D25
  
T Full ratings are found in the breaker frames table on Breaker Frames

Assembled Circuit Breakers with Electronic Trip Units

Rated Current In [A] Protection Type Breaking Capacity/
Interrupting Rating [kA]T 
Cat. No. Breaking Capacity/
Interrupting Rating [kA]T 
Cat. No. Breaking Capacity/
Interrupting Rating [kA]T 
Cat. No.
400V 480V 400V 480V 400V 480V
50 LS 25 25 140U-J2L3-C50 40 35 140U-J3L3-C50 70 65 140U-J6L3-C50
50 LSI 25 25 140U-J2H3-C50 40 35 140U-J3H3-C50 70 65 140U-J6H3-C50
50 LSG 25 25 140U-J2G3-C50 40 35 140U-J3G3-C50 70 65 140U-J6G3-C50
50 LSIG 25 25 140U-J2I3-C50 40 35 140U-J3I3-C50 70 65 140U-J6I3-C50
100 LS 25 25 140U-J2L3-D10 40 35 140U-J3L3-D10 70 65 140U-J6L3-D10
100 LSI 25 25 140U-J2H3-D10 40 35 140U-J3H3-D10 70 65 140U-J6H3-D10
100 LSG 25 25 140U-J2G3-D10 40 35 140U-J3G3-D10 70 65 140U-J6G3-D10
100 LSIG 25 25 140U-J2I3-D10 40 35 140U-J3I3-D10 70 65 140U-J6I3-D10
160 LS 25 25 140U-J2L3-D16 40 35 140U-J3L3-D16 70 65 140U-J6L3-D16
160 LSI 25 25 140U-J2H3-D16 40 35 140U-J3H3-D16 70 65 140U-J6H3-D16
160 LSG 25 25 140U-J2G3-D16 40 35 140U-J3G3-D16 70 65 140U-J6G3-D16
160 LSIG 25 25 140U-J2I3-D16 40 35 140U-J3I3-D16 70 65 140U-J6I3-D16
250 LS 25 25 140U-J2L3-D25 40 35 140U-J3L3-D25 70 65 140U-J6L3-D25
250 LSI 25 25 140U-J2H3-D25 40 35 140U-J3H3-D25 70 65 140U-J6H3-D25
250 LSI 25 25 140U-J2G3-D25 40 35 140U-J3H3-D25 70 65 140U-J6G3-D25
250 LSIG 25 25 140U-J2I3-D25 40 35 140U-J3I3-D25 70 65 140U-J6I3-D25
  
T Full ratings are found in the breaker frames table on Breaker Frames

Molded Case Switch — UL 489

Rated Current In [A] Thermal Trip
Ir = In [A]
Magnetic Trip [A]
Im = 10 x In
Breaking Capacity (50 Hz)
Icu /Ics [kA]
Interrupting Rating
(60 Hz) [kA]
Cat. No.
220…240V 380…415V 500V 690V 240V 480V 600V
250 2500 100 100 70 70 42 20 7 3 100 65 25 140U-J6S3-D25
  

Accessories — 250 A, J-Frame

Internal Control Modules — Field Installed

  Description Diagram Mounting Location Cat. No.
Click to enlarge - 58_125AAux_006287_bw Auxiliary Contact (AX)
Electrically indicates "ON/OFF" status of breakers
(1) 1a-1b Click to enlarge - 140U-43-3 Click to enlarge - 140U-51-2 140U-H-EA1
(2) 1a-1b Left AND Right side 140U-H-EA2
Alarm Contact (AL)
Electrically indicates when the breaker is in the "TRIPPED" state
(1) 1M (make)-1B (break) Click to enlarge - 140U-43-5 Click to enlarge - 140U-43-2 140U-J-ER1
Right side ONLY
Click to enlarge - 60_125ACombo_006283_bw Auxiliary/Alarm Contact (AX/AL)
Combination

Combination of auxiliary contact and alarm contact
(1) 1a-1b
(1) 1M (make)-1B (break)
Click to enlarge - 140U-43-8 Click to enlarge - 140U-43-2 140U-J-EA1R1
Right side ONLY
Click to enlarge - 140U-51-9 Shunt Trip (SNT)
Provides remote tripping of the circuit breaker
Undervoltage trip not available when shunt trip is used
12V DC Click to enlarge - 140U-43-11 Click to enlarge - 140U-43-10 140U-H-SNZQ
24…60 V, 50/60/DC 140U-H-SNJ
110…240V, 50/60/DC 140U-H-SND
380…600V, 50/60 Hz Left side ONLY 140U-H-SNB
Undervoltage Release (UVT)
Automatically trips breaker when voltage falls between preset value, 35…70%
Shunt trip is not available when undervoltage release is used
24V, 50/60 Hz Click to enlarge - 140U-43-13 Click to enlarge - 140U-43-10 140U-H-UJ
110…127V, 50/60 Hz 140U-H-UD
208…240V, 50/60 Hz 140U-H-UA
380…500V, 50/60 Hz 140U-H-UB
525…600V, 50/60 Hz Left side ONLY 140U-H-UC
  

Note: For Factory-Installed internal control modules, please see Internal Control Modules — Factory Installed

For use with H-, J-, K-, L-, M-, and N-Frame Molded Case Circuit Breakers


Terminal Lugs

  Description Frame Size Cat. No.
Click to enlarge - 140U-J-TLS1_C Terminal Lugs Aluminum lugs, Al or Cu wire
(1) 4…350 MCM
or (1) 25…185 mm2
Qty: 1 J 140U-J-TLA1
Stainless Steel Box Lugs,
Cu wire Only
(1) 4…350 MCM
or (1) 25…185 mm2
Qty: 1 J 140U-J-TLS1
  

External Accessories

  Description Cat. No.
Click to enlarge - ab_cover_006589_bw Terminal Shields
IP20 Ingress Protection Rating
140U-J-TS
Click to enlarge - 140U-H-FCX03_R_bw Flex-Cable Operating Mechanism
Includes handle, cable, operating, and bail mechanism
Pre-assembled and adjusted
Non-Metallic - UL IP66, Type 1/3/12/4/4X
Flange Mount Operating Handle
3 ft (0.9 m) Cable 140U-J-FCX03
4 ft (1.3 m) Cable 140U-J-FCX04
6 ft (1.9 m) Cable 140U-J-FCX06
10 ft (3.0 m) Cable 140U-J-FCX10
Flex-Cable Operating Mechanism
Stainless Steel IP66/ UL Type 1/3/12/4/4X
Flange-Mount Operating Handle
3 ft (0.9 m) Cable 140U-J-FCS03
4 ft (1.2 m) Cable 140U-J-FCS04
6 ft (1.9 m) Cable 140U-J-FCS06
10 ft (3.0 m) Cable 140U-J-FCS10
Flex-Cable Operating Mechanism
Includes handle, cable, operating, and bail mechanism
Pre-assembled and adjusted
Painted metal — Type 1/12
Flange mount operating handle
3 ft (0.9 m) Cable 140U-J-FMX03
4 ft (1.2 m) Cable 140U-J-FMX04
6 ft (1.9 m) Cable 140U-J-FMX06
10 ft (3.0 m) Cable 140U-J-FMX10
Click to enlarge - 140U-H-RVM12R_C_bw Rotary, Variable-Depth Operating Mechanism
UL Type 3/12/4/4X, IP 66 Rotary handle
12 in. (30.48 cm) operating rod
Black Handle 140U-J-RVM12B
Red/Yellow Handle 140U-J-RVM12R
Rotary, Variable-Depth Operating Mechanism
UL Type 3/12/4/4X, IP 66 Rotary handle
21 in. (53.34 cm) operating rod
Black Handle 140U-J-RVM21B
Red/Yellow Handle 140U-J-RVM21R
Click to enlarge - NFPA_lockout sml_bw Rotary, Variable-Depth Operating Mechanism with Internal NFPA 79 Operating Handle
External Type 3/4/4X/12 IP66 Rotary Handle
12 in. (30.48 cm) operating rod
Black Handle 140U-J-NVM12B
Red/Yellow Handle 140U-J-NVM12R
Rotary, Variable-Depth Operating Mechanism with Internal NFPA 79 Operating Handle
External Type 3/4/4X/12 IP66 Rotary Handle
21 in. (53.34 cm) operating rod
Black Handle 140U-J-NVM21B
Red/Yellow Handle 140U-J-NVM21R
Click to enlarge - NFPA_handle_bw Rotary, Direct Couple Operating Mechanism
Breaker mounted
Black Handle 140U-J-RCB
Red/Yellow Handle 140U-J-RCR
Click to enlarge - 140U-H-ECM_C_bw End Cap Kit
Provides 3-phase connections for
terminal or bolt-on connections
Metric hardware
140U-J-ECM
Click to enlarge - 140U-H-PB_C_bw Phase Barriers
Provides additional phase clearance when special connections that extend past the circuit breaker housing are required
Qty: 2 140U-J-PB
Click to enlarge - 140U-H-PL_C_bw Padlock Kit
Padlocking hasp
Lock-OFF only
Qty: 1 140U-J-PL
Click to enlarge - 140U_H_MTL3AN_right_bw Multi-Tap Terminal Lug Kit — with IP20 terminal cover (3) #14…2 AWG
or (3) 2.5…25 mm2
Qty: 3 140U-J-MTL3A
Click to enlarge - 140U_H_MTL6AN_right_bw (6) #14…6 AWG
or (6) 2.5…10 mm2
Qty: 3 140U-J-MTL6A
Click to enlarge - 140U-J-ELP_front_a_bw Ground Fault Leakage Module
Current pickup settings are selectable from 0.03…10 A with time delays up to. Time delays are also selectable from Instantaneous…1.0 s for 0.10 A settings and above. A current pickup setting of 0.03 A defaults to an Instantaneous time setting regardless of the time dial’s position. Two alarm contacts come as standard: a 50% pretrip and a 100% after trip contact, both based only on earth leakage current levels.
150 A For use with J-Frame 3 pole MCCBs up to 150 A 140U-J-GFP1503
250 A For use with J-Frame 3-pole MCCBs up to 250 A 140U-J-GFP2503
Click to enlarge - ab_switch-21474_bw Motor Operator
Remotely opens, closes, and resets the circuit breaker
110…240V AC
For use with 3- or 4-Pole MCCBs, 110…240V AC/DC 140U-J-EOPD
For use with 3- or 4-Pole MCCBs, 24V DC 140U-J-EOPZ
Click to enlarge - 140U-J-MHM_bw Replacement Mounting Hardware
(4) M4 - 0.7 x 90 mm § 
For use with 3- or 4-Pole MCCBs 140U-J-MHM
  
§ Supplied with breaker.

Approximate Dimensions — 250 A, J-Frame

Dimensions are in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.

Click to enlarge - 140U-49-1