Molded Case Circuit Breakers

Catalogs > Industrial Controls Catalog > Motor Control, IEC > Molded Case Circuit Breakers > Bulletin 140U K-Frame

Bulletin 140U K-Frame

Product Selection — 400 A, K-Frame Accessories — 400 A, K-Frame Approximate Dimensions — 400 A, K-Frame
Product Selection — 400 A, K-Frame

Click to enlarge - 140U-39-4



Note: Terminal lugs must be ordered separately. See Optional Terminal Lug Kits

Breaker Frames

Rated Current In [A] Breaking Capacity (50 Hz)
Icu /Ics [kA]
Interrupting Rating (60 Hz) [kA] Cat. No.
220…240V 380…415V 500V 690V 240V 480V 600V
400 65 65 40 40 30 30 10 5 65 35 25 140U-K3X3
100 100 35 35 50 38 13 6 100 65 35 140U-K6X3
200 200 100 100 65 49 18 9 200 100 65 140U-K0X3
  

Trip Units and Rating Plugs

Thermal-Magnetic
Rated Current In [A] Adjustment Range [A] Cat. No.
Thermal Trip [A]
Ir = In (Fixed)
Magnetic Trip
Im = 5…10 x In
100 100 500…1000 140U-KTD3-D10
125 125 625…1250 140U-KTD3-D12
150 150 750…1500 140U-KTD3-D15
175 175 895…1750 140U-KTD3-D17
200 200 1000…2000 140U-KTD3-D20
225 225 1125…2250 140U-KTD3-D22
250 250 1250…2500 140U-KTD3-D25
300 300 1500…3000 140U-KTD3-D30
350 350 1750…3500 140U-KTD3-D35
400 400 2000…4000 140U-KTD3-D40
  

Electronic
Rated Current In [A] Adjustment Range [A] Protection Type Cat. No.
Thermal Trip
Ir = 0.5…1.0 x In
Magnetic Trip
Im = 2…8 x Ir
400 200…400¬  400…3200 LS 140U-KTL3-D40
LSI 140U-KTH3-D40
LSG 140U-KTG3-D40
LSIG 140U-KTI3-D40
  
Electronic trip units require the use of a rating plug. Select proper rating plug to cover thermal trip requirement.

Rating Plugs
Thermal Trip In [A] Cat. No. Thermal Trip In [A] Cat. No.
200 140U-KRP3-D20 300 140U-KRP3-D30
225 140U-KRP3-D22 350 140U-KRP3-D35
250 140U-KRP3-D25 400 140U-KRP3-D40
  

Assembled Circuit Breakers, Thermal-Magnetic Trip Units

Rated Current In [A] Breaking Capacity/
Interrupting Rating [kA]T 
Cat. No. Breaking Capacity/
Interrupting Rating [kA]T 
Cat. No. Breaking Capacity/
Interrupting Rating [kA]T 
Cat. No.
400V 480V 400V 480V 400V 480V
100 40 35 140U-K3D3-D10 65 65 140U-K6D3-D10 100 100 140U-K0D3-D10
125 40 35 140U-K3D3-D12 65 65 140U-K6D3-D12 100 100 140U-K0D3-D12
150 40 35 140U-K3D3-D15 65 65 140U-K6D3-D15 100 100 140U-K0D3-D15
175 40 35 140U-K3D3-D17 65 65 140U-K6D3-D17 100 100 140U-K0D3-D17
200 40 35 140U-K3D3-D20 65 65 140U-K6D3-D20 100 100 140U-K0D3-D20
225 40 35 140U-K3D3-D22 65 65 140U-K6D3-D22 100 100 140U-K0D3-D22
250 40 35 140U-K3D3-D25 65 65 140U-K6D3-D25 100 100 140U-K0D3-D25
300 40 35 140U-K3D3-D30 65 65 140U-K6D3-D30 100 100 140U-K0D3-D30
350 40 35 140U-K3D3-D35 65 65 140U-K6D3-D35 100 100 140U-K0D3-D35
400 40 35 140U-K3D3-D40 65 65 140U-K6D3-D40 100 100 140U-K0D3-D40
  
Assembled circuit breakers can be created by adding a trip unit and rating plugs (electronic only) to a circuit breaker frame. Example: Cat. No. 140U-K3X3 + 140U-KTL3-D40 + 140U-KRP3-D35
T Full ratings are found in the breaker frames table on Breaker Frames

Assembled Circuit Breakers, Electronic Trip Units

Rated Current In [A] Thermal Trip
Ir = 0.5…1.0 x In
Protection Type Breaking Capacity/
Interrupting Rating [kA]T 
Cat. No. Breaking Capacity/
Interrupting Rating [kA]T 
Cat. No. Breaking Capacity/
Interrupting Rating [kA]T 
Cat. No.
400V 480V 400V 480V 400V 480V
400 100…400¬  LS 40 35 140U-K3L3-D40 65 65 140U-K6L3-D40 100 100 140U-K0L3-D40
LSI 40 35 140U-K3H3-D40 65 65 140U-K6H3-D40 100 100 140U-K0H3-D40
LSG 40 35 140U-K3G3-D40 65 65 140U-K6G3-D40 100 100 140U-K0G3-D40
  
¬ Select proper rating plug to cover thermal trip requirement.
T Full ratings are found in the breaker frames table on Breaker Frames

Molded Case Switch — UL 489

Rated Current In [A] Magnetic Trip
10 x In
Breaking Capacity (50 Hz) Icu /Ics [kA] Interrupting Rating (60 Hz) [kA] Cat. No.
220…240V 380…415V 500V 690V 240V 480V 600V
400 4000 100 100 65 65 50 38 13 6 100 65 35 140U-K6S3-D40
  

Optional Terminal Lug Kits

  Description Pkg. Quantity Cat. No.
Click to enlarge - 140U_K_TLA1A_right_bw Terminal Lugs Aluminum lug, Al or Cu wire
(1) 3…350 MCM
or (1) 30…185 mm2
1 140U-K-TLA1A
Aluminum lug, Al or Cu wire
(1) 250…500 MCM
or (1) 120…240 mm2
140U-K-TLA1
Aluminum lug, Al or Cu wire
(2) 3/0…250 MCM
or (2) 95…120 mm2
3 (includes shield) 140U-K-TLA2
Click to enlarge - 140U_K_TLA2_right_bw Terminal Lugs Copper lug, Cu wire only
(1) 3…350 MCM
or (1) 30…185 mm2
1 140U-K-TLC1A
Copper lug, Cu wire only
(1) 250…500 MCM
or (1) 120…240 mm2
140U-K-TLC1
Copper lug, Cu wire only
(2) 3/0…250 MCM
or (2) 95…120 mm2
3 (includes shield) 140U-K-TLC2
Aluminum lug, Al or Cu wire
(2) 2/0…250 MCM
or (1) 2/0…500 MCM,
(2) 70…120 mm2
or (1) 70…240 mm2
3 (includes shield) 140U-K-TLA2A
Aluminum lug, Al or Cu wire
(1) 500…750 MCM
or (1) 300…400 mm2
140U-K-TLA1B
Click to enlarge - 140U_K_TLC1B_right_bw Terminal Lugs Copper lug, Cu wire only
(1) 500…750 MCM
or (1) 300…400 mm2
3 (includes shield) 140U-K-TLC1B
Click to enlarge - 140U_H_MTL3AN_right_bw Multi-Tap Terminal Lug Kit — with IP20 terminal cover (3) #12…2/0 AWG
or (3) 4…67 mm2
3 140U-K-MTL3A
(6) #14…2 AWG
or (6) 2.5…33 mm2
3 140U-K-MTL6A