Bulletin 140U M-Frame

Product Selection — 800 A, M-Frame

Click to enlarge - 140U-39-6



Note: Terminal box lugs must be ordered separately. See

Breaker Frames

Rated Current In [A] Breaking Capacity (50 Hz) Icu /Ics [kA] Interrupting Rating (60 Hz) [kA] Cat. No.
220…240V 380…415V 525V 690V 240V 480V 600V
800 65 65 50 50 50 25 20 10 65 50 25 140U-M5X3
100 100 70 70 70 50 25 13 100 65 35 140U-M6X3
  

Trip Units and Rating Plugs

Thermal-Magnetic
Rated Current In [A] Adjustment Range [A] Cat. No.
Thermal Trip
Ir = In
Magnetic Trip
Im = 5…10 x In
300 300 1500…3000 140U-MTD3-D30
350 350 1750…3500 140U-MTD3-D35
400 400 2000…4000 140U-MTD3-D40
450 450 2250…4500 140U-MTD3-D45
500 500 2500…5000 140U-MTD3-D50
600 600 3000…6000 140U-MTD3-D60
700 700 3500…7000 140U-MTD3-D70
800 800 4000…8000 140U-MTD3-D80

Electronic
Rated Current In [A] Adjustment Range [A] Protection Type Cat. No.
Thermal Trip
Ir = 0.5…1.0 x In
Magnetic Trip
Im = 2…8 x In
800A 400…800¬  800…6400 400…800 A LS Electronic Trip Unit 140U-MTL3-D80
400…800 A LSI Electronic Trip Unit 140U-MTH3-D80
400…800 A LSG Electronic Trip Unit 140U-MTG3-D80
400…800 A LSIG Electronic Trip Unit 140U-MTI3-D80
  
Select proper rating plug to cover thermal trip requirement.

Rating Plugs
Thermal Trip
In [A]
Cat. No. Thermal Trip
In [A]
Cat. No.
400 140U-MRP3-D40 700 140U-MRP3-D70
500 140U-MRP3-D50 800 140U-MRP3-D80
600 140U-MRP3-D60
  

Assembled Circuit Breakers, Thermal-Magnetic Trip Units

Rated Current In [A] Thermal Trip
Ir = In
Breaking Capacity/Interrupting Rating [kA]T  Cat. No. Breaking Capacity/Interrupting Rating [kA]T  Cat. No.
400V 480V 400V 480V
300 300 50 50 140U-M5D3-D30 70 65 140U-M6D3-D30
350 350 50 50 140U-M5D3-D35 70 65 140U-M6D3-D35
400 400 50 50 140U-M5D3-D40 70 65 140U-M6D3-D40
450 450 50 50 140U-M5D3-D45 70 65 140U-M6D3-D45
500 500 50 50 140U-M5D3-D50 70 65 140U-M6D3-D50
600 600 50 50 140U-M5D3-D60 70 65 140U-M6D3-D60
700 700 50 50 140U-M5D3-D70 70 65 140U-M6D3-D70
800 800 50 50 140U-M5D3-D80 70 65 140U-M6D3-D80
  
T Full ratings are found in the breaker frames table on Breaker Frames

Assembled Circuit Breakers, Electronic Trip Units

Rated Current In [A] Thermal Trip
Ir = 0.5…1.0 x In
Protection Type Breaking Capacity/
Interrupting Rating [kA]T 
Cat. No. Breaking Capacity/
Interrupting Rating [kA]T 
Cat. No.
400V 480V 400V 480V
800 200…800¬  LS 50 50 140U-M5L3-D80 70 65 140U-M6L3-D80
LSI 50 50 140U-M5H3-D80 70 65 140U-M6H3-D80
LSG 50 50 140U-M5G3-D80 70 65 140U-M6G3-D80
  
¬ Select proper rating plug to cover thermal trip requirement.
T Full ratings are found in the breaker frames table on Breaker Frames

Molded Case Switch — UL 489

Rated Current In [A] Magnetic Trip [A]
Im = 10 x In
Breaking Capacity (50 Hz) Icu /Ics [kA] Interrupting Rating (60 Hz) [kA] Cat. No.
220…240V 380…415V 500V 690V 240V 480V 600V
800 8000 100 100 70 70 70 50 25 13 100 65 35 140U-M6S3-D80

Accessories — 800 A, M-Frame

Internal Control Modules — Field Installed

  Description Mounting Location Diagram Cat. No.
Click to enlarge - 140U-51-1 Auxiliary Contact (AX)
Electrically indicates "ON/OFF" status of breakers
(1) 1a-1b Click to enlarge - 140U-51-2 Click to enlarge - 140U-43-3 140U-M-EA1
(2) 1a-1b Left AND Right Side 140U-M-EA2
Alarm Contact (AL)
Electrically indicates when the breaker is in the "TRIPPED" state
(1) 1M (make)-1B (break) Click to enlarge - 140U-43-2 Click to enlarge - 140U-43-5 140U-M-ER1
Right Side Only
Click to enlarge - 140U-51-6 Auxiliary/Alarm Contact (AX/AL)
Combination

Combination of auxiliary contact and alarm contact
(1) 1a-1b
(1) 1M (make)-1B (break)
Click to enlarge - 140U-43-2 Click to enlarge - 140U-43-8 140U-M-EA1R1
Right Side Only
Click to enlarge - 140U-51-9 Shunt Trip (SNT)
Provides remote tripping of the circuit breaker
Undervoltage trip not available when shunt trip is used
12…24V, 50/60/DC Click to enlarge - 140U-43-10 Click to enlarge - 140U-43-11 140U-M-SNJ
110…240V AC, 110…125V DC 140U-M-SND
380…440V AC, 220…250V DC 140U-M-SNN
480…600V, 50/60 Hz Left Side Only 140U-M-SNB
Undervoltage Release (UVT)
Automatically trips breaker when voltage falls between preset value, 35…70%
Shunt trip is not available when undervoltage release is used
24V, 50/60 Hz Click to enlarge - 140U-43-10 Click to enlarge - 140U-43-13 140U-M-UJ
110…127V, 50/60 Hz 140U-M-UD
208…240V, 50/60 Hz 140U-M-UA
380…500V, 50/60 Hz Left Side Only 140U-M-UB
  

Note: For Factory-Installed internal control modules, please see Internal Control Modules — Factory Installed

For use with H-, J-, K-, L-, M-, and N-Frame Molded Case Circuit Breakers


External Accessories

  Description Cat. No.
Click to enlarge - 140U-52-3 Flex-Cable Operating Mechanism
Includes handle, cable, operating, and bail mechanism
Pre-assembled and adjusted
UL Type 1/3/12/4/4X
Flange-Mount Operating Handle
Non-Metallic
4 ft (1.3 m) Cable 140U-M-FCX04
6 ft (1.8 m) Cable 140U-M-FCX06
10 ft (3.0 m) Cable 140U-M-FCX10
Flex-Cable Operating Mechanism
Includes handle, cable, operating, and bail mechanism
Pre-assembled and adjusted
UL Type 4/4X
Flange-Mount Operating Handle
Stainless Steel
4 ft (1.3 m) Cable 140U-M-FCS04
6 ft (1.8 m) Cable 140U-M-FCS06
10 ft (3.0 m) Cable 140U-M-FCS10
Flex-Cable Operating Mechanism
Includes handle, cable, operating, and bail mechanism
Pre-assembled and adjusted
Painted metal — Type 1/12
Flange mount operating handle
4 ft (1.2 m) Cable 140U-M-FMX04
6 ft (1.9 m) Cable 140U-M-FMX06
10 ft (3.0 m) Cable 140U-M-FMX10
Click to enlarge - 140U-52-4 Rotary, Variable-Depth Operating Mechanism
UL Type 3/12/4/4X, IP 66 Rotary Handle
12 in. (30.48 cm) operating rod
Black Handle 140U-M-RVM12B
Red/Yellow Handle 140U-M-RVM12R
Rotary, Variable-Depth Operating Mechanism
UL Type 3/12/4/4X, IP 66 Rotary Handle
21 in. (53.34 cm) operating rod
Black Handle 140U-M-RVM21B
Red/Yellow Handle 140U-M-RVM21R
Rotary, Variable-Depth Operating Mechanism with Internal NFPA79 Operating Handle
External UL Type 3/12/4/4X, IP 66 Rotary Handle
12 in. (30.48 cm) operating rod
Black Handle 140U-M-NVM12B
Red/Yellow Handle 140U-M-NVM12R
Rotary, Variable-Depth Operating Mechanism with Internal NFPA79 Operating Handle
External UL Type 3/12/4/4X, IP 66 Rotary Handle
21 in. (53.34 cm) operating rod
Black Handle 140U-M-NVM21B
Red/Yellow Handle 140U-M-NVM21R
Click to enlarge - 140M-21-9 Terminal Lugs Copper lug, Cu wire Only
(3) 3/0…300 MCM
or (3) 95…135 mm2
Qty: 1 140U-M-TLC3
Aluminum lug, Al or Cu wire
(3) 3/0…400 MCM
or (3) 95…185 mm2
Qty: 1 140U-M-TLA3
Click to enlarge - 140U_M_TLA2_right_bw Terminal Lugs Aluminum lug, Al or Cu wire
(2) 1…500 MCM
or (2) 50…240 mm2
Qty: 1 140U-M-TLA2
Click to enlarge - 140U_M_TLC2A_right_bw Aluminum lug, Al or Cu wire
(2) 500…750 MCM
or (2) 240…400 mm2
Qty: 1 140U-M-TLA2A
Click to enlarge - 140U_M_TLC2_right_bw Copper lug, Cu wire only
(2) 2/0…500 MCM
or (2) 70…240 mm2
Qty: 1 140U-M-TLC2
Click to enlarge - 140M-20-5 Phase Barriers
Provides additional phase clearance when special connections that extend past the circuit breaker housing are required
Qty: 2 140U-M-PB
Click to enlarge - 140M-20-3 Padlock Kit
Padlocking Hasp
Lock-OFF only
Qty: 1 140U-M-PL
Click to enlarge - 140R-M-MHM_bw Replacement Mounting Hardware
(4) M8 - 1 x 35 mm § 
For use with 3- or 4-Pole MCCBs 140U-M-MHM
  
§ Supplied with breaker.

Approximate Dimensions — 800 A, M-Frame

Dimensions are in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.

Click to enlarge - 140U-61-1