Description
|
Mounting Location
|
Diagram
|
Cat. No.
|
|
Auxiliary Contact (AX) Electrically indicates "ON/OFF" status of breakers
|
(1) 1a-1b
|
|
|
140U-H-EA1
|
| (2) 1a-1b
|
Right Side Only
|
140U-H-EA2
|
Alarm Contact (AL) Electrically indicates when the breaker is in the "TRIPPED" state
|
(1) 1M (make)-1B (break)
|
|
|
140U-H-ER1
|
| Right Side Only
|
|
Auxiliary/Alarm Contact (AX/AL) Combination Combination of auxiliary contact and alarm contact
|
(1) 1a-1b (1) 1M (make)-1B (break)
|
|
|
140U-H-EA1R1
|
| Right Side Only
|
|
Shunt Trip (SNT) Provides remote tripping of the circuit breaker Undervoltage trip not available when shunt trip is used
|
24…60 V, 50/60/DC
|
|
|
140U-H-SNJ
|
| 110…240V, 50/60/DC
|
140U-H-SND
|
| 380…600V, 50/60 Hz
|
Left Side Only
|
140U-H-SNB
|
Undervoltage Release (UVT) Automatically trips breaker when voltage falls between preset value, 35…70% Shunt trip is not available when undervoltage release is used
|
24V, 50/60Hz AC; 24V DC
|
|
|
140U-H-UJ
|
| 110…127V, 50/60 Hz
|
140U-H-UD
|
| 208…240V, 50/60 Hz
|
140U-H-UA
|
| 380…500V, 50/60 Hz
|
140U-H-UB
|
| 525…600V, 50/60 Hz
|
Left Side Only
|
140U-H-UC
|
|
|
Auxiliary and Alarm Contacts
|
Suffix
|
| (1) AX
|
- A
|
| (2) AX
|
- B
|
| (1) AL
|
- D
|
| (1) AX + (1) AL
|
- F
|
|
|
Shunt Trip Combinations
|
Suffix
|
| (1) SNT only
|
- PÄ
|
| (1) AX + (1) SNT
|
- QÄ
|
| (2) AX + (1) SNT
|
- RÄ
|
| (1) AX + (1) AL + (1) SNT
|
- TÄ
|
| (1) AL + (1) SNT
|
- VÄ
|
| ÄStandard Voltage Suffix Codes¬
|
| Voltage [V]
|
24…60
|
110…240
|
380…600
|
AC, 50/60 Hz
|
J
|
D
|
B
|
| DC
|
J
|
D
|
—
|
|
|
| Undervoltage Release Combinations
|
Suffix
|
| (1) UVT only
|
- GÄ
|
| (1) AX + (1) UVT
|
- HÄ
|
| (2) AX + (1) UVT
|
- JÄ
|
| (1) AX + (1) AL + (1) UVT
|
- LÄ
|
| (1) AL + (1) UVT
|
- NÄ
|
| ÄStandard Voltage Suffix Codes¬
|
| Voltage [V]
|
24
|
110…127
|
208…240
|
380…500
|
525…600
|
AC, 50/60 Hz
|
J
|
D
|
A
|
B
|
C
|
| DC
|
J
|
—
|
—
|
—
|
—
|
|
|
|
|
Description
|
For Use With
|
Cat. No.
|
|
Terminal End Cover 6.4 mm (0.25 in.) diameter cable entry
|
Qty: 1
|
3-Pole MCCBs
|
140U-H-TC2
|
Terminal End Cover 10.4 mm (0.41 in.) diameter cable entry
|
3-Pole MCCBs
|
140U-H-TC4
|
|
Terminal Shields IP20 Ingress Protection Rating
|
Qty: 1
|
3-Pole MCCBs
|
140U-H-TS
|
| Qty: 1
|
4-Pole MCCBs
|
140U-H-TS4
|
|
Rotary, Variable-Depth Operating Mechanism Rotary handle - IP66, UL Type 3/12/4/4X 21 in. (53.34 cm) operating rod
|
Black Handle 12 in. (30.5 cm)Shaft
|
3- or 4-Pole MCCBs
|
140U-H-RVM12B
|
Red/Yellow Handle 12 in. (30.5 cm)Shaft
|
140U-H-RVM12R
|
Black Handle 21 in. (53.4 cm)Shaft
|
140U-H-RVM21B
|
Red/Yellow Handle 21 in. (53.4 cm)Shaft
|
140U-H-RVM21R
|
|
Flex-Cable Operating Mechanism Includes handle, cable, operating, and bail mechanism Pre-assembled and adjusted Non-Metallic - UL IP66, Type 1/3/12/4/4X Flange Mount Operating Handle
|
1.5 ft (0.46 m) Cable
|
3-Pole MCCBs
|
140U-H-FCX01
|
| 3 ft (0.9 m) Cable
|
140U-H-FCX03
|
| 4 ft (1.3 m) Cable
|
140U-H-FCX04
|
| 6 ft (1.8 m) Cable
|
140U-H-FCX06
|
| 10 ft (3.0 m) Cable
|
140U-H-FCX10
|
|
Rotary, Direct Couple Operating Mechanism Rotary handle - IP42 UL Type 1 Breaker mounted
|
Black Handle
|
3- or 4-Pole MCCBs
|
140U-H-RCB
|
| Red/Yellow Handle
|
140U-H-RCR
|
|
End Cap Kit Provides three-phase connections for terminal or bolt-on connections Metric hardware provided
|
Qty: 1
|
3-Pole MCCBs
|
140U-H-ECM
|
| Qty: 1
|
4-Pole MCCBs
|
140U-H-ECM4
|
|
Multi-Tap Terminal Lugs
|
(3) #14…2 AWG or (3) 2.5…35 mm2
|
Qty: 3
|
3-Pole MCCBs
|
140U-H-MTL3AN
|
(6) #14…6 AWG or (6) 2.5…10 mm2
|
Qty: 3
|
3-Pole MCCBs
|
140U-H-MTL6AN
|
(3) #14…2 AWG or (3) 2.5…35 mm2
|
Qty: 3 with terminal shield
|
3-Pole MCCBs
|
140U-H-MTL3A
|
(6) #14…6 AWG or (6) 2.5…10 mm2
|
Qty: 3 with terminal shield
|
3-Pole MCCBs
|
140U-H-MTL6A
|
| Cat. No. 140U-H-MTL3AN
|
(3) #14…2 AWG or (3) 2.5…35 mm2
|
Qty: 4
|
4-Pole MCCBs
|
140U-H-MTL3A4
|
|
|
(6) #14…6 AWG or (6) 2.5…10 mm2
|
Qty: 4
|
4-Pole MCCBs
|
140U-H-MTL6A4
|
|
|
|
|
Description
|
For Use With
|
Cat. No.
|
|
Phase Barriers Provides additional phase clearance when special connections that extend past the circuit breaker housing are required
|
Qty: 2
|
3-Pole MCCBs
|
140U-H-PB
|
| Qty: 3
|
4-Pole MCCBs
|
140U-H-PB4
|
|
Padlock Kit Padlocking hasp Lock-OFF only
|
Qty: 1
|
3- or 4-Pole MCCBs
|
140U-H-PL
|
|
DIN Rail Adapter Allows H-frame MCCB to mount to 35 mm DIN Rail
|
Qty: 1
|
3-Pole H-Frame MCCBs
|
140U-H-DRA
|
|
Plug-in Base Adapters Plug-in provides power terminations and adapter for applications where the ability to quickly remove or replace the circuit breakers is required
|
Qty: 1
|
3-Pole MCCBs
|
140U-H-PAD3
|
| 4-Pole MCCBs
|
140U-H-PAD4
|
Plug-in Base Auxiliary Contacts Provides auxiliary contact functions to detect breaker installation status
|
Qty: 1
|
3- or 4-Pole MCCBs
|
140U-H-PDK
|
|
Replacement Mounting Hardware (4) M4 - 0.7 x 75 mm
|
Qty: 1
|
3- or 4-Pole MCCBs
|
140U-H-MHM
|
|
Motor Operator Remotely opens, closes, and resets the circuit breaker 110…240V AC
|
Qty: 1
|
3- or 4-Pole MCCBs, 110…240V AC/DC
|
140U-H-EOPD
|
| 3- or 4-Pole MCCBs, 24V DC
|
140U-H-EOPZ
|
|
Slide Bar Interlock
|
Qty: 1
|
—
|
140U-H-SBLK
|
|
|