Molded Case Circuit Breakers

Catalogs > Industrial Controls Catalog > Motor Control, IEC > Molded Case Circuit Breakers > Bulletin 140UE J-Frame

Bulletin 140UE J-Frame

Product Selection — 250 A, J-Frame Operating Handles (Accepts 3 Padlocks) Approximate Dimensions
Product Selection — 250 A, J-Frame

Click to enlarge - 140U-39-3



Note: Terminal box lugs and mounting hardware included.

Circuit breakers can be assembled from a circuit breaker frame and a trip unit, or purchased as assembled units.



Example:

Cat. No. 140UE-J2X3 (frame) + Cat. No. 140UE-JTF3-C80 (trip unit) = Cat. No. 140UE-J2F3-C80 (equivalent assembled circuit breaker)


Breaker Frames

Rated
Current
In [A]
Breaking Capacity (50 Hz)
Icu /Ics [kA]
NEMA Interrupt Rating (60 Hz)
[kA]
Cat. No.
220…240V 380…415V 500V 690V 240V 480V 600V 3-Pole 4-Pole
250 65 65 25 25 20 12 12 6 65 25 18 140UE-J2X3 140UE-J2X4
85 85 40 40 35 20 12 6 85 35 18 140UE-J4X3 140UE-J4X4
100 100 70 70 42 20 14 7 100 65 25 140UE-J7X3 140UE-J7X4
  

Trip Units, Thermal-Magnetic

Rated Current In [A] Adjustment Range [A] Protection Type Cat. No.
Thermal Trip Adjusment Range
Ir = 0.8…1.0 In
Magnetic Trip
Im = 5…10 x In
3-Pole 4-Pole ⋆ 
80 64…80 400…800 AA 140UE-JTF3-C80 140UE-JTF4-C80
100 80…100 500…1000 AA 140UE-JTF3-D10 140UE-JTF4-D10
125 100…125 625…1250 AA 140UE-JTF3-D12 140UE-JTF4-D12
160 128…160 800…1600 AA 140UE-JTF3-D16 140UE-JTF4-D16
200 160…200 1000…2000 AA 140UE-JTF3-D20 140UE-JTF4-D20
250 200…250 1250…2500 AA 140UE-JTF3-D25 140UE-JTF4-D25
  
⋆ 4th pole neutral — 0/100% protected

Trip Units, Electronic

Rated Current In [A] Adjustment Range [A] Protection Type⋆  Ground Fault Functions Cat. No.
Thermal Trip
Ir = 0.4…1.0 x In
Magnetic Trip
Im = 2…10 x In
IG=0.2…1.0IN TG=ms 3-Pole 4-Pole
50 20…50 40…700 LS 140UE-JTL3-C50 140UE-JTL4-C50
50 20…50 40…700 LSI 140UE-JTH3-C50 140UE-JTH4-C50
50 20…50 40…700 LSG 10…50 Inst., 120, 300 140UE-JTG3-C50 140UE-JTG4-C50
50 20…50 40…700 LSIG 10…50 Inst., 120, 300 140UE-JTI3-C50 140UE-JTI4-C50
100 40…100 80…1400 LS 140UE-JTL3-D10 140UE-JTL4-D10
100 40…100 80…1400 LSI 140UE-JTH3-D10 140UE-JTH4-D10
100 40…100 80…1400 LSG 20…100 Inst., 120, 300 140UE-JTG3-D10 140UE-JTG4-D10
100 40…100 80…1400 LSIG 20…100 Inst., 120, 300 140UE-JTI3-D10 140UE-JTI4-D10
160 63…160 126…2240 LS 140UE-JTL3-D16 140UE-JTL4-D16
160 63…160 126…2240 LSI 140UE-JTH3-D16 140UE-JTH4-D16
160 63…160 126…2240 LSG 32…160 Inst., 120, 300 140UE-JTG3-D16 140UE-JTG4-D16
160 63…160 126…2240 LSIG 32…160 Inst., 120, 300 140UE-JTI3-D16 140UE-JTI4-D16
250 100…250 200…3500 LS 140UE-JTL3-D25 140UE-JTL4-D25
250 100…250 200…3500 LSI 140UE-JTH3-D25 140UE-JTH4-D25
250 100…250 200…3500 LSG 50…250 Inst., 120, 300 140UE-JTG3-D25 140UE-JTG4-D25
250 100…250 200…3500 LSIG 50…250 Inst., 120, 300 140UE-JTI3-D25 140UE-JTI4-D25
  
Adjustable long-time delay: 2…24s @ 6 times Ir
Adjustable short-time delay: Inst., 120 ms, 300 ms

Assembled Circuit Breakers, Thermal-Magnetic Trip Units

Rated Current In [A] Protection Type
In
Breaking Capacity 380…415V (50 Hz)
3 Poles 4 Poles
25 kA 40 kA 70 kA 25 kA 40 kA 70 kA
Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No.
80 AA 140UE-J2F3-C80 140UE-J4F3-C80 140UE-J7F3-C80 140UE-J2F4-C80 140UE-J4F4-C80 140UE-J7F4-C80
100 AA 140UE-J2F3-D10 140UE-J4F3-D10 140UE-J7F3-D10 140UE-J2F4-D10 140UE-J4F4-D10 140UE-J7F4-D10
125 AA 140UE-J2F3-D12 140UE-J4F3-D12 140UE-J7F3-D12 140UE-J2F4-D12 140UE-J4F4-D12 140UE-J7F4-D12
160 AA 140UE-J2F3-D16 140UE-J4F3-D16 140UE-J7F3-D16 140UE-J2F4-D16 140UE-J4F4-D16 140UE-J7F4-D16
200 AA 140UE-J2F3-D20 140UE-J4F3-D20 140UE-J7F3-D20 140UE-J2F4-D20 140UE-J4F4-D20 140UE-J7F4-D20
250 AA 140UE-J2F3-D25 140UE-J4F3-D25 140UE-J7F3-D25 140UE-J2F4-D25 140UE-J4F4-D25 140UE-J7F4-D25
  

Assembled Circuit Breakers, Electronic Trip Units

Rated Current In [A] Protection Type Breaking Capacity 380…415V (50 Hz)
3 Poles 4 Poles
25 kA 40 kA 70 kA 25 kA 40 kA 70 kA
Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No.
50 LS 140UE-J2L3-C50 140UE-J4L3-C50 140UE-J7L3-C50 140UE-J2L4-C50 140UE-J4L4-C50 140UE-J7L4-C50
50 LSI 140UE-J2H3-C50 140UE-J4H3-C50 140UE-J7H3-C50 140UE-J2H4-C50 140UE-J4H4-C50 140UE-J7H4-C50
50 LSG 140UE-J2G3-C50 140UE-J4G3-C50 140UE-J7G3-C50 140UE-J2G4-C50 140UE-J4G4-C50 140UE-J7G4-C50
50 LSIG 140UE-J2I3-C50 140UE-J4I3-C50 140UE-J7I3-C50 140UE-J2I4-C50 140UE-J4I4-C50 140UE-J7I4-C50
100 LS 140UE-J2L3-D10 140UE-J4L3-D10 140UE-J7L3-D10 140UE-J2L4-D10 140UE-J4L4-D10 140UE-J7L4-D10
100 LSI 140UE-J2H3-D10 140UE-J4H3-D10 140UE-J7H3-D10 140UE-J2H4-D10 140UE-J4H4-D10 140UE-J7H4-D10
100 LSIG 140UE-J2G3-D10 140UE-J4G3-D10 140UE-J7G3-D10 140UE-J2G4-D10 140UE-J4G4-D10 140UE-J7G4-D10
100 LSIG 140UE-J2I3-D10 140UE-J4I3-D10 140UE-J7I3-D10 140UE-J2I4-D10 140UE-J4I4-D10 140UE-J7I4-D10
160 LS 140UE-J2L3-D16 140UE-J4L3-D16 140UE-J7L3-D16 140UE-J2L4-D16 140UE-J4L4-D16 140UE-J7L4-D16
160 LSI 140UE-J2H3-D16 140UE-J4H3-D16 140UE-J7H3-D16 140UE-J2H4-D16 140UE-J4H4-D16 140UE-J7H4-D16
160 LSG 140UE-J2G3-D16 140UE-J4G3-D16 140UE-J7G3-D16 140UE-J2G4-D16 140UE-J4G4-D16 140UE-J7G4-D16
160 LSIG 140UE-J2I3-D16 140UE-J4I3-D16 140UE-J7I3-D16 140UE-J2I4-D16 140UE-J4I4-D16 140UE-J7I4-D16
250 LS 140UE-J2L3-D25 140UE-J4L3-D25 140UE-J7L3-D25 140UE-J2L4-D25 140UE-J4L4-D25 140UE-J7L4-D25
250 LSI 140UE-J2H3-D25 140UE-J4H3-D25 140UE-J7H3-D25 140UE-J2H4-D25 140UE-J4H4-D25 140UE-J7H4-D25
250 LSG 140UE-J2G3-D25 140UE-J4G3-D25 140UE-J7G3-D25 140UE-J2G4-D25 140UE-J4G4-D25 140UE-J7G4-D25
250 LSIG 140UE-J2I3-D25 140UE-J4I3-D25 140UE-J7I3-D25 140UE-J2I4-D25 140UE-J4I4-D25 140UE-J7I4-D25
  

Isolation Disconnector — IEC 60947-3

Rated Current
In [A]
Thermal Trip
Ir = In [A]
Magnetic Trip [A]
Im = 10 x In
Breaking Capacity (50 Hz)
Icu /Ics [kA]
Interrupting Rating
(60 Hz) [kA]
Cat. No.
220…240V 380…415V 500V 690V 240V 480V 600V 3-Pole 4-Pole
250 2500 100 100 70 70 25 10 14 7 100 65 25 140UE-J7S3-D25 140UE-J7S4-D25