Description
|
Mounting Location
|
Diagram
|
Cat. No.
|
|
Auxiliary Contact (AX) Electrically indicates "ON/OFF" status of breakers
|
(1) 1a-1b
|
|
|
140U-M-EA1
|
| (2) 1a-1b
|
Left AND Right side
|
140U-M-EA2
|
Alarm Contact (AL) Electrically indicates when the breaker is in the "TRIPPED" state
|
(1) 1M (make)-1B (break)
|
|
|
140U-M-ER1
|
| Right side ONLY
|
|
Auxiliary/Alarm Contact (AX/AL) Combination Combination of auxiliary contact and alarm contact
|
(1) 1a-1b (1) 1M (make)-1B (break)
|
|
|
140U-M-EA1R1
|
| Right side ONLY
|
|
Shunt Trip (SNT) Provides remote tripping of the circuit breaker Undervoltage trip not available when shunt trip is used
|
12…24V, 50/60/DC
|
|
|
140U-M-SNJ
|
| 110…240V AC, 110…125V DC
|
140U-M-SND
|
| 380…440V AC, 220…250V DC
|
140U-M-SNN
|
| 480…600V, 50/60 Hz
|
Left side ONLY
|
140U-M-SNB
|
Undervoltage Release (UVT) Automatically trips breaker when voltage falls between preset value, 35…70% Shunt trip is not available when undervoltage release is used
|
24V, 50/60 Hz
|
|
|
140U-M-UJ
|
| 110…127V, 50/60 Hz
|
140U-M-UD
|
| 208…240V, 50/60 Hz
|
140U-M-UA
|
| 380…500V, 50/60 Hz
|
Left side ONLY
|
140U-M-UB
|
|
|
Auxiliary and Alarm Contacts
|
Suffix
|
| (1) AX
|
- A
|
| (2) AX
|
- B
|
| (1) AL
|
- D
|
| (1) AX + (1) AL
|
- F
|
|
|
| Shunt Trip Combinations
|
Suffix
|
| (1) SNT only
|
- PÄ
|
| (1) AX + (1) SNT
|
- QÄ
|
| (2) AX + (1) SNT
|
- RÄ
|
| (1) AX + (1) AL + (1) SNT
|
- TÄ
|
| (1) AL + (1) SNT
|
- VÄ
|
| ÄStandard Voltage Suffix Codes¬
|
| Voltage [V]
|
12…24
|
110…240
|
380…440
|
480…600
|
AC, 50/60 Hz
|
J
|
D
|
N
|
B
|
| Voltage [V]
|
12…24
|
110…125
|
220…250
|
—
|
| DC
|
J
|
D
|
N
|
—
|
|
|
| Undervoltage Release Combinations
|
Suffix
|
| (1) UVT only
|
- GÄ
|
| (1) AX + (1) UVT
|
- HÄ
|
| (2) AX + (1) UVT
|
- JÄ
|
| (1) AX + (1) AL + (1) UVT
|
- LÄ
|
| (1) AL + (1) UVT
|
- NÄ
|
| ÄStandard Voltage Suffix Codes¬
|
| Voltage [V]
|
24
|
110…127
|
208…240
|
380…480
|
AC, 50/60 Hz
|
J
|
D
|
A
|
B
|
| Voltage [V]
|
—
|
—
|
—
|
—
|
| DC
|
—
|
—
|
—
|
—
|
|
|
|
|
Description
|
Cat. No.
|
|
Flex-Cable Operating Mechanism Includes handle, cable, operating, and bail mechanism Pre-assembled and adjusted UL Type 1/3/12/4/4X Flange-Mount Operating Handle Non-Metallic
|
4 ft (1.3 m) Cable
|
140U-M-FCX04
|
| 6 ft (1.8 m) Cable
|
140U-M-FCX06
|
| 10 ft (3.0 m) Cable
|
140U-M-FCX10
|
Flex-Cable Operating Mechanism Includes handle, cable, operating, and bail mechanism Pre-assembled and adjusted UL Type 4/4X Flange-Mount Operating Handle Stainless Steel
|
4 ft (1.3 m) Cable
|
140U-M-FCS04
|
| 6 ft (1.8 m) Cable
|
140U-M-FCS06
|
| 10 ft (3.0 m) Cable
|
140U-M-FCS10
|
|
Rotary, Variable-Depth Operating Mechanism UL Type 3/12/4/4X, IP 66 Rotary Handle 12 in. (30.48 cm) operating rod
|
Black Handle
|
140U-M-RVM12B
|
| Red/Yellow Handle
|
140U-M-RVM12R
|
Rotary, Variable-Depth Operating Mechanism UL Type 3/12/4/4X, IP 66 Rotary Handle 21 in. (53.34 cm) operating rod
|
Black Handle
|
140U-M-RVM21B
|
| Red/Yellow Handle
|
140U-M-RVM21R
|
|
Terminal Lugs
|
Copper lug, Cu wire Only (3) 3/0…300 MCM or (3) 95…135 mm2
|
Qty: 1
|
140U-M-TLC3
|
Aluminum lug, Al or Cu wire (3) 3/0…400 MCM or (3) 95…185 mm2
|
Qty: 1
|
140U-M-TLA3
|
|
Terminal Lugs
|
Aluminum lug, Al or Cu wire (2) 1…500 MCM or (2) 50…240 mm2
|
Qty: 1
|
140U-M-TLA2
|
|
Terminal Lugs
|
Aluminum lug, Al or Cu wire (2) 500…750 MCM or (2) 240…400 mm2
|
Qty: 1
|
140U-M-TLA2A
|
|
Terminal Lugs
|
Copper lug, Cu wire only (2) 2/0…500 MCM or (2) 70…240 mm2
|
Qty: 1
|
140U-M-TLC2
|
|
Phase Barriers Provides additional phase clearance when special connections that extend past the circuit breaker housing are required
|
Qty: 2
|
140U-M-PB
|
|
Padlock Kit Padlocking Hasp Lock-OFF only
|
Qty: 1
|
140U-M-PL
|
|
Operating Handle Extension Provides handle extension for ease of operation
|
Qty: 1
|
140U-M-OHE
|
|
Replacement Mounting Hardware (4) M8 - 1 x 35 mm
|
Qty: 1
|
140U-M-MHM
|
|
|