Open Type Starters

Catalogs > Industrial Controls Catalog > Motor Control, IEC > Open Type Starters > Bulletin 105-C Reversing Starter Open Type — Eutectic Alloy

Bulletin 105-C Reversing Starter Open Type — Eutectic Alloy

Introduction Standards Compliance and Certifications Product Selection — Open Type, Eutectic Alloy Overload Relay, AC Operated Approximate Dimensions
Your order must include: 1) Cat. No. of reversing starter selected, 2) coil voltage code.

Product Selection — Open Type, Eutectic Alloy Overload Relay, AC Operated

Reversing Starters with AC Coils — Prices do not include heater elements. Starters require 3 overload heater elements. See the Industrial Control Catalog for selection tables.

Ratings (AC3, AC4) Open Type
Max
Ie
[A]
kW Hp
3Æ 1Æ 3Æ Cat. No.
380V/415V 115V 230V 200V 230V 460V 575V
9 4 1/3 1 2 2 5 7-1/2 105-C09NÄJOV
12 5-1/2 1/2 2 3 3 7-1/2 10 105-C12NÄJOV
16 7-1/2 1 3 5 5 10 15 105-C16NÄJOV
23 11 2 3 5 7-1/2 15 15 105-C23NÄJOV
30 15 2 5 7-1/2 10 20 25 105-C30NÄKOV
37 18-1/2 3 5 10 10 25 30 105-C37NÄCOV
43 22 3 7-1/2 10 15 30 30 105-C43NÄCOV
60 30 5 10 15 20 40 50 105-C60NÄCOV
72 37 5 15 20 25 50 60 105-C72NÄDOV
110 55 30 40 75 100 105-B110NÄDOV
  

µ Coil Voltage Code

The Cat. No. as listed is incomplete. Select a Coil Voltage Code from the table below to complete the Cat. No. Example: Cat. No. 105-C09NÄJOV becomes Cat. No. 105-C09NDJOV.

For 105-C Starters
AC Voltage 24 48 110 120 208 208...
240
220 240 277 380...
400
400...
415
440 480 500 600
Common Control
Coil Voltage Code
50 Hz A T N G B M
60 Hz H L A N B C
Separate Control (without transformer)
Coil Voltage Code
50 Hz K Y D
60 Hz J X D T
For 105-B Starters
AC Voltage 24 48 110 120 208 208...
240
220 240 277 380 415 440 480 500 600
Common Control
Coil Voltage Code
50 Hz A T N I B M
60 Hz H L A G B C
Separate Control (without transformer)
Coil Voltage Code
50 Hz K Y D
60 Hz J X D F
  

For 105-B Starters
AC Voltage 24 48 110 120 208 208...
240
220 240 277 380 415 440 480 500 600
Common Control
Coil Voltage Code
50 Hz A T N I B M
60 Hz H L A G B C
Separate Control (without transformer)
Coil Voltage Code
50 Hz K Y D
60 Hz J X D F
  

Product Selection

Reversing Starters with DC Coils — Prices do not include heater elements. Starters require 3 overload heater elements. See the Industrial Control Catalog for selection tables.

Ratings (AC3, AC4) Open Type
Max Ie
[A]
kW Hp
3Æ 1Æ 3Æ Cat. No.
380V/415V 115V 230V 200V 230V 460V 575V
9 4 1/3 1 2 2 5 7-1/2 105-C09NZÄJOV
12 5-1/2 1/2 2 3 3 7-1/2 10 105-C12NZÄJOV
16 7-1/2 1 3 5 5 10 15 105-C16NZÄJOV
23 11 2 3 5 7-1/2 15 15 105-C23NZÄJOV
30 15 2 5 7-1/2 10 20 25 105-C30NZÄKOV
37 18-1/2 3 5 10 10 25 30 105-C37NZÄCOV
43 22 3 7-1/2 10 15 30 30 105-C43NZÄCOV
60 30 5 10 15 20 40 50 105-C60NDÄCOV
72 37 5 15 20 25 50 60 105-C72NDÄDOV
110 55 30 40 75 100 105-B110NZÄDOV
  

µ Coil Voltage Code

The Cat. No. as listed is incomplete. Select a Coil Voltage Code from the table below to complete the Cat. No. Example: Cat. No. 105-C09NZÄJOV becomes Cat. No. 105-C09NZJJOV.

DC Voltage 12V 24V 48V 64V 80V 115V 125V 230V 250V
105-C Starter Coil Voltage Code Q J Y B E P S F T
105-B110 Starter Coil Voltage Code 12 24 48 64 80 01 03 23 25