Catalogs > Industrial Controls Catalog > Motor Control, IEC > Open Type Starters > Bulletin 105-C Reversing Starter Open Type — Eutectic Alloy
Bulletin 105-C Reversing Starter Open Type — Eutectic Alloy
| Introduction | Standards Compliance and Certifications | Product Selection — Open Type, Eutectic Alloy Overload Relay, AC Operated | Approximate Dimensions |
Product Selection — Open Type, Eutectic Alloy Overload Relay, AC Operated
Reversing Starters with AC Coils — Prices do not include heater elements. Starters require 3 overload heater elements. See the Industrial Control Catalog for selection tables.
| Ratings (AC3, AC4) | Open Type | |||||||
| Max Ie [A] |
kW | Hp | ||||||
| 3Æ | 1Æ | 3Æ | Cat. No. | |||||
| 380V/415V | 115V | 230V | 200V | 230V | 460V | 575V | ||
| 9 | 4 | 1/3 | 1 | 2 | 2 | 5 | 7-1/2 | 105-C09NÄJOV |
| 12 | 5-1/2 | 1/2 | 2 | 3 | 3 | 7-1/2 | 10 | 105-C12NÄJOV |
| 16 | 7-1/2 | 1 | 3 | 5 | 5 | 10 | 15 | 105-C16NÄJOV |
| 23 | 11 | 2 | 3 | 5 | 7-1/2 | 15 | 15 | 105-C23NÄJOV |
| 30 | 15 | 2 | 5 | 7-1/2 | 10 | 20 | 25 | 105-C30NÄKOV |
| 37 | 18-1/2 | 3 | 5 | 10 | 10 | 25 | 30 | 105-C37NÄCOV |
| 43 | 22 | 3 | 7-1/2 | 10 | 15 | 30 | 30 | 105-C43NÄCOV |
| 60 | 30 | 5 | 10 | 15 | 20 | 40 | 50 | 105-C60NÄCOV |
| 72 | 37 | 5 | 15 | 20 | 25 | 50 | 60 | 105-C72NÄDOV |
| 110 | 55 | — | — | 30 | 40 | 75 | 100 | 105-B110NÄDOV |
µ Coil Voltage Code
The Cat. No. as listed is incomplete. Select a Coil Voltage Code from the table below to complete the Cat. No. Example: Cat. No. 105-C09NÄJOV becomes Cat. No. 105-C09NDJOV.
| For 105-C Starters | ||||||||||||||||
| AC Voltage | 24 | 48 | 110 | 120 | 208 | 208... 240 |
220 | 240 | 277 | 380... 400 |
400... 415 |
440 | 480 | 500 | 600 | |
| Common Control Coil Voltage Code |
50 Hz | — | — | — | — | — | — | A | T | — | N | G | B | — | M | — |
| 60 Hz | — | — | — | — | H | L | — | A | — | — | — | N | B | — | C | |
| Separate Control (without transformer) Coil Voltage Code |
50 Hz | K | Y | D | — | — | — | — | — | — | — | — | — | — | — | — |
| 60 Hz | J | X | — | D | — | — | — | — | T | — | — | — | — | — | — | |
| For 105-B Starters | ||||||||||||||||
| AC Voltage | 24 | 48 | 110 | 120 | 208 | 208... 240 |
220 | 240 | 277 | 380 | 415 | 440 | 480 | 500 | 600 | |
| Common Control Coil Voltage Code |
50 Hz | — | — | — | — | — | — | A | T | — | N | I | B | — | M | — |
| 60 Hz | — | — | — | — | H | L | — | A | — | — | — | G | B | — | C | |
| Separate Control (without transformer) Coil Voltage Code |
50 Hz | K | Y | D | — | — | — | — | — | — | — | — | — | — | — | — |
| 60 Hz | J | X | — | D | — | — | — | — | F | — | — | — | — | — | — | |
| For 105-B Starters | ||||||||||||||||
| AC Voltage | 24 | 48 | 110 | 120 | 208 | 208... 240 |
220 | 240 | 277 | 380 | 415 | 440 | 480 | 500 | 600 | |
| Common Control Coil Voltage Code |
50 Hz | — | — | — | — | — | — | A | T | — | N | I | B | — | M | — |
| 60 Hz | — | — | — | — | H | L | — | A | — | — | — | G | B | — | C | |
| Separate Control (without transformer) Coil Voltage Code |
50 Hz | K | Y | D | — | — | — | — | — | — | — | — | — | — | — | — |
| 60 Hz | J | X | — | D | — | — | — | — | F | — | — | — | — | — | — | |
Product Selection
Reversing Starters with DC Coils — Prices do not include heater elements. Starters require 3 overload heater elements. See the Industrial Control Catalog for selection tables.
| Ratings (AC3, AC4) | Open Type | |||||||
| Max Ie [A] |
kW | Hp | ||||||
| 3Æ | 1Æ | 3Æ | Cat. No. | |||||
| 380V/415V | 115V | 230V | 200V | 230V | 460V | 575V | ||
| 9 | 4 | 1/3 | 1 | 2 | 2 | 5 | 7-1/2 | 105-C09NZÄJOV |
| 12 | 5-1/2 | 1/2 | 2 | 3 | 3 | 7-1/2 | 10 | 105-C12NZÄJOV |
| 16 | 7-1/2 | 1 | 3 | 5 | 5 | 10 | 15 | 105-C16NZÄJOV |
| 23 | 11 | 2 | 3 | 5 | 7-1/2 | 15 | 15 | 105-C23NZÄJOV |
| 30 | 15 | 2 | 5 | 7-1/2 | 10 | 20 | 25 | 105-C30NZÄKOV |
| 37 | 18-1/2 | 3 | 5 | 10 | 10 | 25 | 30 | 105-C37NZÄCOV |
| 43 | 22 | 3 | 7-1/2 | 10 | 15 | 30 | 30 | 105-C43NZÄCOV |
| 60 | 30 | 5 | 10 | 15 | 20 | 40 | 50 | 105-C60NDÄCOV |
| 72 | 37 | 5 | 15 | 20 | 25 | 50 | 60 | 105-C72NDÄDOV |
| 110 | 55 | — | — | 30 | 40 | 75 | 100 | 105-B110NZÄDOV |
µ Coil Voltage Code
The Cat. No. as listed is incomplete. Select a Coil Voltage Code from the table below to complete the Cat. No. Example: Cat. No. 105-C09NZÄJOV becomes Cat. No. 105-C09NZJJOV.
| DC Voltage | 12V | 24V | 48V | 64V | 80V | 115V | 125V | 230V | 250V |
| 105-C Starter Coil Voltage Code | Q | J | Y | B | E | P | S | F | T |
| 105-B110 Starter Coil Voltage Code | 12 | 24 | 48 | 64 | 80 | 01 | 03 | 23 | 25 |