Bulletin 190/191E Eco and Bulletin 190/191S Compact Combination Starters

Catalogs > Industrial Controls Catalog > Motor Control, IEC > Open Type Starters > Bulletin 190/191E Eco and Bulletin 190/191S Compact Combination Starters > Bulletin 190/191S Compact Combination Starters

Bulletin 190/191S Compact Combination Starters

Bulletin 190S Direct On-Line Compact Starters

Click to enlarge - 190E-163-1 Click to enlarge - DC_symbol


Click to enlarge - 190S_pp_18_1 Click to enlarge - 103S_wd_13_1

Group Motor, Type E and Type F Combination Motor Controllers (UL/CSA)

The 190S/191S motor controllers can be used in a variety of applications. These starters can be used in a group motor application or as a stand alone product without any additional short-circuit protection in the motor branch circuits.



Most of the 140M-C/D motor protection circuit breakers used in the 190S/191S starters are UL Listed as a manual Type E self-protected combination motor controller. Although there are many tests involved, one of the critical tests a self-protected combination motor controller must pass, is to perform 6000 electrical ops. and an additional 4000 mechanical ops. after a short circuit.



By definition, a Type F combination motor controller consists of a Type E manual self protected combination motor controller and a magnetic or solid-state motor controller (such as a 100-C contactor or an SMC). As with a manual Type E self-protected combination motor controller, additional short-circuit protection is not required for the individual motor circuits.



A combination of a 140M manual self protected combination motor controller and 100-C contactor can be listed as a Type E self-protected combination motor controller. In this case, the 140M and 100-C must pass the additional 6000 electrical and 4000 mechanical operational test. In some cases, this may require over sizing of the 140M motor protection circuit breaker or the 100-C contactor to achieve weld-free performance and meet the additional life requirements.


Note: Verify that the motor protection circuit breaker can be set to the rated motor current.

Product Selection and Coordination Ratings — UL/CSA in Group Motor Installations

Motor Current Adjustment Range [A] UL/CSA Hp Ratings (60 Hz) Max. Fuse or Circuit Breaker per NEC [A] Max. Short-Circuit Current [kA] DOL Starter Reversing Starter
(AC coils only)
Hp Ratings as a UL508 Motor Controller in Group Motor Installations§  Type 1 Coordination Type 2 Coordination
200V 230V 460V 575V 480V 600V 480V 600V Cat. No. Cat. No.
C-Frame with Bulletin 100-C/104-C Contactors
0.10…0.16 450 65 47 65 47 190S-ANÄ2-CA16C 191S-ANÄ3-CA16C
0.16…0.25 450 65 47 65 47 190S-ANÄ2-CA25C 191S-ANÄ3-CA25C
0.25…0.40 450 65 47 65 47 190S-ANÄ2-CA40C 191S-ANÄ3-CA40C
0.40…0.63 450 65 47 65 47 190S-ANÄ2-CA63C 191S-ANÄ3-CA63C
0.63…1.00 1/2 3/4 450 65 47 65 47 190S-ANÄ2-CB10C 191S-ANÄ3-CB10C
1.00…1.60 1/2…1 3/4...1 450 65 47 65 47 190S-ANÄ2-CB16C 191S-ANÄ3-CB16C
1.60…2.50 1/2 1/2...3/4 3/4…1-1/2 1…2 450 65 30 65 10 190S-ANÄ2-CB25C 191S-ANÄ3-CB25C
2.50…4.00 1/2…1 3/4...1 1-1/2…3 2…3 450 65 30 50 190S-ANÄ2-CB40C 191S-ANÄ3-CB40C
4.00…6.30 1...1-1/2 1…2 3...5 5 450 65 30 50 190S-ANÄ2-CB63C 191S-ANÄ3-CB63C
6.30…9.00 1-1/2…2 2 5 7-1/2 450 65 30 50 190S-ANÄ2-CC10C 191S-ANÄ3-CC10C
6.30…10.0 1-1/2…3 2...3 5...7-1/2 7-1/2...10 450 65 30 50 190S-BNÄ2-CC10C 191S-BNÄ3-CC10C
10.0…12.0 3 3 7-1/2 10 450 30 30 190S-BNÄ2-CC16C 191S-BNÄ3-CC16C
10.0…16.0 3...5 5 7-1/2…10 10 450 30 30 190S-CNÄ2-CC16C 191S-CNÄ3-CC16C
10.0…16.0 3...5 5 7-1/2…10 10...15 450 30 30 190S-DNÄ2-CC16C 191S-DNÄ3-CC16C
14.5…20.0 5 5...7-1/2 15 15 450 30 30 190S-DNÄ2-CC20C 191S-DNÄ3-CC20C
18.0…23.0 5 7-1/2 15 15 450 30 30 190S-DNÄ2-CC25C 191S-DNÄ3-CC25C
D-Frame with Bulletin 100-C/104-C Contactors
1.60…2.50 1/2 1/2...3/4 3/4…1-1/2 1…2 450 65 30 65 10 190S-ANÄ2-DB25C 191S-ANÄ3-DB25C
1.60…2.50 1/2 1/2...3/4 3/4…1-1/2 1…2 450 65 30 65 30 190S-DNÄ2-DB25C 191S-DNÄ3-DB25C
2.50…4.00 1/2…1 3/4...1 1-1/2…3 2…3 450 65 30 65 190S-ANÄ2-DB40C 191S-ANÄ3-DB40C
2.50…4.00 1/2…1 3/4...1 1-1/2…3 2…3 450 65 30 65 30 190S-DNÄ2-DB40C 191S-DNÄ3-DB40C
4.00…6.30 1…1-1/2 1…2 3…5 5 450 65 30 65 190S-ANÄ2-DB63C 191S-ANÄ3-DB63C
6.30…9.00 1-1/2…2 2 5 7-1/2 450 65 30 65 190S-ANÄ2-DC10C 191S-ANÄ3-DC10C
6.30…10.0 1-1/2…3 2...3 5…7-1/2 7-1/2…10 450 65 30 65 190S-BNÄ2-DC10C 191S-BNÄ3-DC10C
6.30…10.0 1-1/2…3 2...3 5…7-1/2 7-1/2…10 450 65 30 65 190S-CNÄ2-DC10C 191S-CNÄ3-DC10C
10.0…12.0 3 3 7-1/2 10 450 65 30 65 190S-BNÄ2-DC16C 191S-BNÄ3-DC16C
10.0…16.0 3…5 5 7-1/2…10 10 450 65 30 65 190S-CNÄ2-DC16C 191S-CNÄ3-DC16C
10.0…16.0 3…5 5 7-1/2…10 10…15 450 65 30 65 190S-DNÄ2-DC16C 191S-DNÄ3-DC16C
14.5…20.0 5 5...7-1/2 15 15 450 65 30 65 190S-DNÄ2-DC20C 191S-DNÄ3-DC20C
18.0…23.0 5 7-1/2 15 15 450 65 30 65 190S-DNÄ2-DC25C 191S-DNÄ3-DC25C
F-Frame with Bulletin 100-C/104-C Contactors
6.30…10.0 1-1/2…3 2...3 5…7-1/2 7-1/2…10 600 65 30 65 30 190S-ENÄ3-FC10C
10.0…16.0 3…5 5 7-1/2…10 10…15 600 65 30 65 30 190S-ENÄ3-FC16C
14.5…20.0 5 5…7-1/2 15 15…20 600 65 30 65 30 190S-ENÄ3-FC20C
18.0…25.0 7-1/2 7-1/2...10 15...20 20 600 65 30 65 30 190S-ENÄ3-FC25C
18.0…25.0 7-1/2 7-1/2...10 15...20 20...25 600 65 30 65 30 190S-GNÄ3-FC25C
23.0…30.0 7-1/2 10 20 25 600 65 30 65 30 190S-ENÄ3-FC32C
23.0…32.0 7-1/2...10 10 20...25 30 600 65 30 65 30 190S-FNÄ3-FC32C
23.0…32.0 7-1/2...10 10 20...25 30 600 65 30 65 30 190S-GNÄ3-FC32C
32.0…37.0 10 10 25 30 600 65 18 65 10 190S-FNÄ3-FC45C
32.0…43.0 10 15 30 30 600 65 18 65 10 190S-GNÄ3-FC45C
  
§ Hp ratings shown in the table are for reference. Final selection of the starter depends upon the actual motor full-load current.

ÄCoil voltage code—see Ä Coil Voltage Codes for AC Control


Product Selection and Coordination Ratings — UL/CSA as a UL508 Type F Combination Motor Controller

Motor Current Adjustment Range [A] UL/CSA Hp Ratings (60 Hz) Max. Short-Circuit Current [kA] DOL Starter Reversing Starter
Hp Ratings as a UL508 Type F Combination Motor Controller§  Type 1 Coordination Type 2 Coordination
200V 230V 460V 575V 480Y/277V 600Y/347V 480Y/277V 600Y/347V Cat. No. Cat. No.
C-Frame with Bulletin 100-C/104-C Contactors and Spacing Adapter
0.10…0.16 65 47 65 47 190S-ANÄ2-CA16C-TE 191S-ANÄ3-CA16C-TE
0.16…0.25 65 47 65 47 190S-ANÄ2-CA25C-TE 191S-ANÄ3-CA25C-TE
0.25…0.40 65 47 65 47 190S-ANÄ2-CA40C-TE 191S-ANÄ3-CA40C-TE
0.40…0.63 65 47 65 47 190S-ANÄ2-CA63C-TE 191S-ANÄ3-CA63C-TE
0.63…1.00 1/2 3/4 65 47 65 47 190S-ANÄ2-CB10C-TE 191S-ANÄ3-CB10C-TE
1.00…1.60 1/2…1 3/4...1 65 47 65 47 190S-ANÄ2-CB16C-TE 191S-ANÄ3-CB16C-TE
1.60…2.50 1/2 1/2...3/4 3/4…1-1/2 1…2 65 30 65 10 190S-ANÄ2-CB25C-TE 191S-ANÄ3-CB25C-TE
2.50…4.00 1/2…1 3/4...1 1-1/2…3 2…3 65 30 190S-ANÄ2-CB40C-TE 191S-ANÄ3-CB40C-TE
4.00…6.30 1...1-1/2 1…2 3...5 65 v  v  190S-ANÄ2-CB63C-TE 191S-ANÄ3-CB63C-TE
6.30…9.00 1-1/2…2 2 5 65 v  v  190S-ANÄ2-CC10C-TE 191S-ANÄ3-CC10C-TE
6.30…10.0 1-1/2…3 2...3 5...7-1/2 65 v  v  190S-BNÄ2-CC10C-TE 191S-BNÄ3-CC10C-TE
10.0…12.0 3 3 7-1/2 30 v  v  190S-BNÄ2-CC16C-TE 191S-BNÄ3-CC16C-TE
10.0…16.0 3...5 5 7-1/2…10 30 v  v  190S-CNÄ2-CC16C-TE 191S-CNÄ3-CC16C-TE
10.0…16.0 3...5 5 7-1/2…10 30 v  v  190S-DNÄ2-CC16C-TE 191S-DNÄ3-CC16C-TE
14.5…20.0 5 5...7-1/2 15 10 v  v  190S-DNÄ2-CC20C-TE 191S-DNÄ3-CC20C-TE
18.0…23.0 v  v  v  v  190S-DNÄ2-CC25C-TE 191S-DNÄ3-CC25C-TE
D-Frame with Bulletin 100-C/104-C Contactors and Spacing Adapter
1.60…2.50 1/2 1/2...3/4 3/4…1-1/2 1…2 65 30 65 10 190S-ANÄ2-DB25C-TE 191S-ANÄ3-DB25C-TE
1.60…2.50 1/2 1/2...3/4 3/4…1-1/2 1…2 65 30 65 30 190S-DNÄ2-DB25C-TE 191S-DNÄ3-DB25C-TE
2.50…4.00 1/2…1 3/4...1 1-1/2…3 2…3 65 30 65 190S-ANÄ2-DB40C-TE 191S-ANÄ3-DB40C-TE
2.50…4.00 1/2…1 3/4...1 1-1/2…3 2…3 65 30 65 30 190S-DNÄ2-DB40C-TE 191S-DNÄ3-DB40C-TE
4.00…6.30 1…1-1/2 1…2 3…5 5 65 30 65 190S-ANÄ2-DB63C-TE 191S-ANÄ3-DB63C-TE
6.30…9.00 1-1/2…2 2 5 7-1/2 65 30 65 190S-ANÄ2-DC10C-TE 191S-ANÄ3-DC10C-TE
6.30…10.0 1-1/2…3 2...3 5…7-1/2 7-1/2…10 65 30 65 190S-BNÄ2-DC10C-TE 191S-BNÄ3-DC10C-TE
6.30…10.0 1-1/2…3 2...3 5…7-1/2 7-1/2…10 65 30 65 190S-CNÄ2-DC10C-TE 191S-CNÄ3-DC10C-TE
10.0…12.0 3 3 7-1/2 10 65 30 65 190S-BNÄ2-DC16C-TE 191S-BNÄ3-DC16C-TE
10.0…16.0 3…5 5 7-1/2…10 10 65 30 65 190S-CNÄ2-DC16C-TE 191S-CNÄ3-DC16C-TE
10.0…16.0 3…5 5 7-1/2…10 10…15 65 30 65 190S-DNÄ2-DC16C-TE 191S-DNÄ3-DC16C-TE
14.5…20.0 5 5...7-1/2 15 65 v  65 v  190S-DNÄ2-DC20C-TE 191S-DNÄ3-DC20C-TE
18.0…23.0 5 7-1/2 15 65 v  65 v  190S-DNÄ2-DC25C-TE 191S-DNÄ3-DC25C-TE
F-Frame with Bulletin 100-C/104-C Contactors and Spacing Adapter
6.30…10.0 1-1/2…3 2...3 5…7-1/2 7-1/2…10 65 30 65 30 190S-ENÄ3-FC10C-TE
10.0…16.0 3…5 5 7-1/2…10 10…15 65 30 65 30 190S-ENÄ3-FC16C-TE
14.5…20.0 5 5…7-1/2 15 15…20 65 30 65 30 190S-ENÄ3-FC20C-TE
18.0…25.0 7-1/2 7-1/2...10 15...20 20 65 30 65 30 190S-ENÄ3-FC25C-TE
18.0…25.0 7-1/2 7-1/2...10 15...20 20...25 65 30 65 30 190S-GNÄ3-FC25C-TE
23.0…30.0 7-1/2 10 20 25 65 30 65 30 190S-ENÄ3-FC32C-TE
23.0…32.0 7-1/2...10 10 20...25 30 65 30 65 30 190S-FNÄ3-FC32C-TE
23.0…32.0 7-1/2...10 10 20...25 30 65 30 65 30 190S-GNÄ3-FC32C-TE
32.0…37.0 10 10 25 65 v  65 v  190S-FNÄ3-FC45C-TE
32.0…43.0 10 15 30 65 v  65 v  190S-GNÄ3-FC45C-TE
  
§ Hp ratings shown in the table are for reference. Final selection of the starter depends upon the actual motor full-load current.
v This starter is not valid for application at this horsepower and voltage.

ÄCoil voltage code—see Ä Coil Voltage Codes for AC Control


Product Selection and Coordination Ratings — UL/CSA as a UL508 Self-Protected Type E Combination Motor Controller

Motor Current Adjustment Range [A] UL/CSA Hp Ratings (60 Hz) Max. Short-Circuit Current [kA] DOL Starter Reversing Starter
Hp Ratings as a UL508 Self-Protected Type E Combination Motor Controller§ 
200V 230V 460V 575V 480Y/277V 600Y/347V Cat. No. Cat. No.
C-Frame with Bulletin 100-C/104-C Contactors and Spacing Adapter
0.10…0.16 65 47 190S-ANÄ2-CA16C-TE 191S-ANÄ3-CA16C-TE
0.16…0.25 65 47 190S-ANÄ2-CA25C-TE 191S-ANÄ3-CA25C-TE
0.25…0.40 65 47 190S-ANÄ2-CA40C-TE 191S-ANÄ3-CA40C-TE
0.40…0.63 65 47 190S-ANÄ2-CA63C-TE 191S-ANÄ3-CA63C-TE
0.63…1.00 1/2 3/4 65 47 190S-ANÄ2-CB10C-TE 191S-ANÄ3-CB10C-TE
1.00…1.60 1/2…1 3/4...1 65 47 190S-ANÄ2-CB16C-TE 191S-ANÄ3-CB16C-TE
1.60…2.50 1/2 1/2...3/4 3/4…1-1/2 65 v  190S-ANÄ2-CB25C-TE 191S-ANÄ3-CB25C-TE
2.50…4.00 v  v  190S-ANÄ2-CB40C-TE 191S-ANÄ3-CB40C-TE
4.00…6.30 v  v  190S-ANÄ2-CB63C-TE 191S-ANÄ3-CB63C-TE
6.30…9.00 v  v  190S-ANÄ2-CC10C-TE 191S-ANÄ3-CC10C-TE
6.30…10.0 v  v  190S-BNÄ2-CC10C-TE 191S-BNÄ3-CC10C-TE
10.0…12.0 v  v  190S-BNÄ2-CC16C-TE 191S-BNÄ3-CC16C-TE
10.0…16.0 v  v  190S-CNÄ2-CC16C-TE 191S-CNÄ3-CC16C-TE
10.0…16.0 v  v  190S-DNÄ2-CC16C-TE 191S-DNÄ3-CC16C-TE
14.5…20.0 v  v  190S-DNÄ2-CC20C-TE 191S-DNÄ3-CC20C-TE
18.0…23.0 v  v  190S-DNÄ2-CC25C-TE 191S-DNÄ3-CC25C-TE
D-Frame with Bulletin 100-C/104-C Contactors and Spacing Adapter
1.60…2.50 1/2 1/2...3/4 3/4…1-1/2 65 v  190S-ANÄ2-DB25C-TE 191S-ANÄ3-DB25C-TE
1.60…2.50 1/2 1/2...3/4 3/4…1-1/2 1…2 65 30 190S-DNÄ2-DB25C-TE 191S-DNÄ3-DB25C-TE
2.50…4.00 v  v  190S-ANÄ2-DB40C-TE 191S-ANÄ3-DB40C-TE
2.50…4.00 1/2…1 3/4...1 1-1/2…3 2…3 65 30 190S-DNÄ2-DB40C-TE 191S-DNÄ3-DB40C-TE
4.00…6.30 v  v  190S-ANÄ2-DB63C-TE 191S-ANÄ3-DB63C-TE
6.30…9.00 v  v  190S-ANÄ2-DC10C-TE 191S-ANÄ3-DC10C-TE
6.30…10.0 v  v  190S-BNÄ2-DC10C-TE 191S-BNÄ3-DC10C-TE
6.30…10.0 v  v  190S-CNÄ2-DC10C-TE 191S-CNÄ3-DC10C-TE
10.0…12.0 v  v  190S-BNÄ2-DC16C-TE 191S-BNÄ3-DC16C-TE
10.0…16.0 v  v  190S-CNÄ2-DC16C-TE 191S-CNÄ3-DC16C-TE
10.0…16.0 v  v  190S-DNÄ2-DC16C-TE 191S-DNÄ3-DC16C-TE
14.5…20.0 v  v  190S-DNÄ2-DC20C-TE 191S-DNÄ3-DC20C-TE
18.0…23.0 v  v  190S-DNÄ2-DC25C-TE 191S-DNÄ3-DC25C-TE
F-Frame with Bulletin 100-C/104-C Contactors and Spacing Adapter
6.30…10.0 1-1/2…3 2...3 5…7-1/2 7-1/2…10 65 30 190S-ENÄ3-FC10C-TE
10.0…16.0 3…5 5 7-1/2…10 10…15 65 30 190S-ENÄ3-FC16C-TE
14.5…20.0 5 5…7-1/2 15 15…20 65 30 190S-ENÄ3-FC20C-TE
18.0…25.0 7-1/2 7-1/2...10 15...20 20 65 30 190S-ENÄ3-FC25C-TE
18.0…25.0 7-1/2 7-1/2...10 15...20 20...25 65 30 190S-GNÄ3-FC25C-TE
23.0…30.0 7-1/2 10 20 25 65 30 190S-ENÄ3-FC32C-TE
23.0…32.0 7-1/2...10 10 20...25 30 65 30 190S-FNÄ3-FC32C-TE
23.0…32.0 7-1/2...10 10 20...25 30 65 30 190S-GNÄ3-FC32C-TE
32.0…37.0 10 10 25 65 v  190S-FNÄ3-FC45C-TE
32.0…43.0 10 15 30 65 v  190S-GNÄ3-FC45C-TE
  
§ Hp ratings shown in the table are for reference. Final selection of the starter depends upon the actual motor full-load current.
v This starter is not valid for application at this horsepower and voltage.

ÄCoil voltage code—see Ä Coil Voltage Codes for AC Control


Product Selection and Coordination Ratings—IEC Type 1 and Type 2 Short-Circuit Coordination

Motor Current Adjustment Range [A] IEC kW Ratings for Standard Motors, 1500 rpm Max. Short-Circuit Current [kA] DOL Starter Reversing Starter
Max. kW, 50 Hz§  Type 1 Coordination Type 2 Coordination
230V 400V 500V 690V 230V 400V 500V 690V 230V 400V 500V 690V Cat. No. Cat. No.
C-Frame with Bulletin 100-C/104-C Contactors
0.10…0.16 0.06 0.06 100 100 65 50 100 100 65 50 190S-ANÄ2-CA16C 191S-ANÄ3-CA16C
0.16…0.25 0.02 0.06 0.06 0.12 100 100 65 50 100 100 65 50 190S-ANÄ2-CA25C 191S-ANÄ3-CA25C
0.25…0.40 0.06 0.09 0.12 0.18 100 100 65 50 100 100 65 50 190S-ANÄ2-CA40C 191S-ANÄ3-CA40C
0.40…0.63 0.09 0.18 0.18 0.37 100 100 65 50 100 100 65 50 190S-ANÄ2-CA63C 191S-ANÄ3-CA63C
0.63…1.00 0.12 0.25 0.37 0.55 100 100 65 50 100 100 65 50 190S-ANÄ2-CB10C 191S-ANÄ3-CB10C
1.00…1.60 0.25 0.55 0.75 1.1 100 100 65 50 100 100 65 50 190S-ANÄ2-CB16C 191S-ANÄ3-CB16C
1.60…2.50 0.55 0.75 1.1 1.8 100 65 50 8 65 50 50 8 190S-ANÄ2-CB25C 191S-ANÄ3-CB25C
2.50…4.00 0.75 1.5 2.2 3 100 50 50 8 50 50 190S-ANÄ2-CB40C 191S-ANÄ3-CB40C
4.00…6.30 1.5 2.2 3 4 100 50 50 4 50 50 190S-ANÄ2-CB63C 191S-ANÄ3-CB63C
6.30…9.00 2.2 4 4 100 65 50 50 50 190S-ANÄ2-CC10C 191S-ANÄ3-CC10C
6.30…10.0 2.2 4 5.5 5.5 100 65 50 4 50 50 50 190S-BNÄ2-CC10C 191S-BNÄ3-CC10C
6.30…10.0 2.2 4 5.5 7.5 100 65 50 4 50 50 50 190S-CNÄ2-CC10C 191S-BNÄ3-CC10C
10.0…12.0 4 5.5 100 65 50 50 190S-BNÄ2-CC16C 191S-BNÄ3-CC16C
10.0…16.0 4 7.5 7.5 100 50 10 50 190S-CNÄ2-CC16C 191S-CNÄ3-CC16C
10.0…16.0 4 7.5 10 10 100 50 10 3 50 50 190S-DNÄ2-CC16C 191S-DNÄ3-CC16C
14.5…20.0 4 10 11 50 15 6 15 190S-DNÄ2-CC20C 191S-DNÄ3-CC20C
18.0…23.0 6.3 11 13 50 15 6 15 190S-DNÄ2-CC25C 191S-DNÄ3-CC25C
D-Frame with Bulletin 100-C/104-C Contactors
1.60…2.50 0.55 0.75 1.1 1.8 100 100 50 10 100 100 50 10 190S-ANÄ2-DB25C 191S-ANÄ3-DB25C
1.60…2.50 0.55 0.75 1.1 1.8 100 100 50 10 100 100 50 10 190S-DNÄ2-DB25C 191S-DNÄ3-DB25C
2.50…4.00 0.75 1.5 2.2 3 100 100 50 10 100 100 50 190S-ANÄ2-DB40C 191S-ANÄ3-DB40C
2.50…4.00 0.75 1.5 2.2 3 100 100 50 50 100 100 50 50 190S-DNÄ2-DB40C 191S-DNÄ3-DB40C
4.00…6.30 1.5 2.2 3 4 100 100 50 50 100 100 50 190S-ANÄ2-DB63C 191S-ANÄ3-DB63C
6.30…9.00 2.2 4 4 100 65 50 100 65 190S-ANÄ2-DC10C 191S-ANÄ3-DC10C
6.30…10.0 2.2 4 5.5 5.5 100 100 65 50 100 100 65 190S-BNÄ2-DC10C 191S-BNÄ3-DC10C
6.30…10.0 2.2 4 5.5 7.5 100 100 65 50 100 100 65 50 190S-CNÄ2-DC10C 191S-CNÄ3-DC10C
10.0…12.0 4 5.5 100 65 65 65 190S-BNÄ2-DC16C 191S-BNÄ3-DC16C
10.0…16.0 4 7.5 7.5 100 65 50 65 65 50 190S-CNÄ2-DC16C 191S-CNÄ3-DC16C
10.0…16.0 4 7.5 10 10 100 65 50 6 65 65 50 190S-DNÄ2-DC16C 191S-DNÄ3-DC16C
14.5…20.0 4 10 11 65 65 25 65 65 25 190S-DNÄ2-DC20C 191S-DNÄ3-DC20C
18.0…23.0 6.3 11 13 65 50 25 65 50 25 190S-DNÄ2-DC25C 191S-DNÄ3-DC25C
F-Frame with Bulletin 100-C/104-C Contactors
6.30…10.0 2.2 4 5.5 7.5 100 100 50 50 100 100 50 50 190S-ENÄ3-FC10C
10.0…16.0 4 7.5 10 13 100 100 50 50 100 100 50 50 190S-ENÄ3-FC16C
14.5…20.0 4 10 11 15 100 100 50 50 100 100 50 50 190S-ENÄ3-FC20C
18.0…25.0 6.3 11 15 100 100 50 100 100 50 190S-ENÄ3-FC25C
18.0…25.0 6.3 11 15 22 100 100 50 50 100 100 50 50 190S-GNÄ3-FC25C
23.0…30.0 7.5 15 15 100 100 50 100 100 50 190S-ENÄ3-FC32C
23.0…32.0 7.5 15 20 100 100 50 100 100 50 190S-FNÄ3-FC32C
23.0…32.0 7.5 15 20 22 100 100 50 50 100 100 50 50 190S-GNÄ3-FC32C
32.0…37.0 11 18.5 100 100 100 100 190S-FNÄ3-FC45C
32.0…43.0 13 22 25 100 100 50 100 100 50 190S-GNÄ3-FC45C
  
§ kW ratings shown in the table are for reference. Final selection of the starter depends upon the actual motor full-load current.

ÄCoil voltage code—see Ä Coil Voltage Codes for AC Control


Bulletin 190S/191S Compact Combination Starters

Ä Coil Voltage Codes for AC Control

[V] 12 24 32 36 42 48 100 100-
110
110 120 127 200 200-
220
200-
230
208 208-
240
AC, 50 Hz R K V W X Y KP D P S KG
AC, 60 Hz Q J V X KP D KG H L
AC, 50/60 Hz KJ KY KP KD KG KL
[V] 220-
230
230 230-
240
240 277 347 380 380-
400
400 400-
415
440 480 500 550 600  
AC, 50 Hz F VA T N G B M C  
AC, 60 Hz A T I E N B C  
AC, 50/60 Hz KF KA KN KB  
  

Ä Coil Voltage Codes for DC Control (Bulletin 190S only)

[V] 9 12 24 36 48 60 64 72 80 110 115 125 220 230 250
Standard DC ZR ZQ ZJ ZW ZY ZZ ZB ZG ZE ZD ZP ZS ZA ZF ZT
with Integrated Diode DJ
Electronic¬  EJ
  
¬ Also available for Bulletin 191S starters.