Catalogs > Industrial Controls Catalog > Motor Control, IEC > Control and Load Switches > Bulletin 194E Load Switches > Bulletin 194E, 125…315 A
Bulletin 194E, 125…315 A
| Introduction | Standards Compliance and Certifications | Overview | Cat. No. Explanation |
| Product Selection | Accessories | Specifications | Approximate Dimensions |
IEC Performance Data for 194E
| 194E-125 | 194E-160 | 194E-250 | 194-315 | ||||
| Rated insulation voltage Ui: ¬ | [V] | 1000 | 1000 | 1000 | 1000 | ||
| Rated impulse withstand voltage Uimp | [kV] | 8 | 8 | 8 | 8 | ||
| Test voltage 1 min | [kV] | 3.5 | 3.5 | 3.5 | 3.5 | ||
| Rated voltage Ue ¬ T | [V] | 1000 | 1000 | 1000 | 1000 | ||
| Rated frequency | [Hz] | 50/60 | 50/60 | 50/60 | 50/60 | ||
| Rated thermal current Ith open | [A] | 125 | 160 | 250 | 315 | ||
| Rated thermal current Ithe enclosed | [A] | 125 | 160 | 250 | 315 | ||
| Rated current Ie | |||||||
| AC-1 / | Non-inductive or slightly induc. load | [A] | 125 | 160 | 250 | 315 | |
| AC-21A | Switching of resistive loads with slight overload |
||||||
| Rated power Pe | |||||||
| AC-23A | Occasional switching of motor and other highly inductive loads |
230V | [kW] | 30 | 30 | 37 | 55 |
| 400V | [kW] | 45 | 55 | 90 | 110 | ||
| 690V | [kW] | 37 | 37 | 45 | 45 | ||
| AC-3 | Squirrel-cage motors: starting and stopping of running motors |
230V | [kW] | 22 | 30 | 37 | 45 |
| 400V | [kW] | 37 | 45 | 55 | 75 | ||
| 690V | [kW] | 30 | 37 | 45 | 45 | ||
| Conditional rated short-circuit current | 400/415V | [kA] | 30 | 30 | 30 | 30 | |
| Max. fuse rating of circuit (type gG) | [A] | 125 | 160 | 250 | 315 | ||
| Rated short-time current Icw 1S | [A] | 2500 | 3000 | 4600 | 5800 | ||
| Rated breaking capacity | 230V | [A] | 800 | 900 | 1600 | 1800 | |
| AC-23A (cos f 0.45) | 400V | [A] | 750 | 850 | 1380 | 1650 | |
| 690V | [A] | 340 | 340 | 400 | 400 | ||
| ¬ Valid for line with grounded common neutral termination, overvoltage category III, pollution degree 3. Other values on request. | |||||||
| T Not suitable for load-switching applications (AC-20A) above 690V. | |||||||
IEC Performance Data for 194E, Continued
| DC Switching Capacity | |||||||
| 194E-125 | 194E-160 | 194E-250 | 194E-315 | ||||
| Rated current Ie | |||||||
| Rated voltage [V] | No. Poles in series | ||||||
| DC-21A | 60 | 3 | [A] | 125 | 160 | 250 | 315 |
| For resistive loads T£1 ms | 110 | 3 | [A] | 110 | 140 | 220 | 280 |
| 220 | 3 | [A] | 45 | 55 | 85 | 110 | |
| Rated voltage [V] | No. Poles in series | ||||||
| 110 | 4 | [A] | 125 | 160 | 250 | 315 | |
| 220 | 4 | [A] | 80 | 100 | 150 | 200 | |
| 440 | 4 | [A] | 16 | 20 | 32 | 40 | |
| Rated power Pe | |||||||
| Rated voltage [V] | No. Poles in series | ||||||
| DC-22A, DC-3 | 24 | 4 | [kW] | 3 | 3.8 | 6 | 7.5 |
| For Inductive loads T£2.5 ms | 48 | 4 | [kW] | 6 | 7.5 | 12 | 15 |
| 60 | 4 | [kW] | 7.5 | 9.5 | 15 | 19 | |
| 110 | 4 | [kW] | 10 | 12.5 | 20 | 25 | |
| 220 | 4 | [kW] | 4.5 | 5.5 | 8 | 10 | |
| Rated Power Pe | |||||||
| Rated voltage [V] | No. Poles in series | ||||||
| DC-23A, DC-5 | 24 | 4 | [kW] | 3 | 3.8 | 6 | 7.5 |
| For Inductive loads T£15 ms | 48 | 4 | [kW] | 6 | 7.5 | 12 | 15 |
| 60 | 4 | [kW] | 7.5 | 9.5 | 15 | 19 | |
| 110 | 4 | [kW] | 8.8 | 11 | 17.5 | 22 | |
| 220 | 4 | [kW] | 2.5 | 3.5 | 5.5 | 7 | |
UL CSA Performance Data for 194E
| 194E-125 | 194E-160 | 194E-250 | 194E-315 | |||
| Rated Insulation Voltage | [V] | 600 | 600 | 600 | 600 | |
| Rated voltage | [V] | 600 | 600 | 600 | 600 | |
| Continuous current | [A] | 150 | 200 | 250 | 300 | |
| Ampere rating for general use | [A] | 150 | 200 | 250 | 300 | |
| Heavy Pilot Duty | [AC] | |||||
| Standard Duty | [DC] | |||||
| Motor rating 60Hz | ||||||
| 1-phase (2 poles) | 120V, 1 P | [FLA] | 80 | 100 | 135 | 180 |
| [Hp] | 7.5 | 10 | 15 | 20 | ||
| 240V, 1 P | [FLA] | 88 | 110 | 136 | 155 | |
| [Hp] | 20 | 25 | 30 | 35 | ||
| 480V, 1 P | [FLA] | 78 | 88 | 99 | 108 | |
| [Hp] | 35 | 40 | 45 | 50 | ||
| 600V, 1 P | [FLA] | 62 | 70 | 86 | 104 | |
| [Hp] | 35 | 40 | 50 | 60 | ||
| 3-Phase | 120V, 3 P | [FLA] | 84 | 108 | 160 | 208 |
| [Hp] | 15 | 20 | 30 | 40 | ||
| 240V, 3 P | [FLA] | 8 | 104 | 154 | 192 | |
| [Hp] | 30 | 40 | 60 | 75 | ||
| 480V, 3 P | [FLA] | 77 | 77 | 96 | 124 | |
| [Hp] | 60 | 60 | 75 | 100 | ||
| 600V, 3 P | [FLA] | 62 | 62 | 77 | 99 | |
| [Hp] | 60 | 60 | 75 | 100 | ||
Mechanical Data
| 194E-125 | 194E-160 | 194E-250 | 194E-315 | ||||
| Handles | IP66 | IP66 | IP66 | IP66 | |||
| Protection class according to IEC 529 | — | — | — | — | |||
| Front side Front unit | IP66 | IP66 | IP66 | IP66 | |||
| Box lugs¬ | IP20 | IP20 | IP20 | IP20 | |||
| Bolt-on | straight version¬ | IP20 | IP20 | IP20 | IP20 | ||
| bent version | — | — | — | — | |||
| Mechanical life | [Million operations] | 0.1 | 0.1 | 0.075 | 0.075 | ||
| Box lugs — max. wire gauges | — | — | — | — | |||
| Terminal sizes according to IEC 947-1 | Gauge No. | B11 | B11 | B14 | B14 | ||
| Fine strands, 1 conductor | Max. | mm2 | 70 | 70 | 150 | 150 | |
| Min. | mm2 | 16 | 16 | 25 | 25 | ||
| Rigid wire, 1 conductor | Max. | mm2 | 95 | 95 | 185 | 185 | |
| Min. | mm2 | 10 | 10 | 16 | 16 | ||
| Wire gauges according to UL/CSA | Max. | AWG | 3/0 | 3/0 | — | — | |
| MCM | — | — | 350 | 350 | |||
| Min. | AWG | 8 | 8 | 4 | 4 | ||
| ¬ When provided with terminal covers. | |||||||
Certifications
| Catalog No. or Designation | UL-Listed (marked with UL) |
UR-Recognized (marked with UR) |
UL-Listed for Canada (marked with cUL) |
UR-Recognized for Canada (marked with cUR) |
CE | |
| 194E-A125 | 194E-E125 | A | — | A | — | A |
| 194E-A160 | 194E-E160 | A | — | A | — | A |
| 194E-A250 | 194E-E250 | A | — | A | — | A |
| 194E-A315 | 194E-E315 | A | — | A | — | A |
| 194E-B125 | 194E-F125 | — | A | — | A | A |
| 194E-B160 | 194E-F160 | — | A | — | A | A |
| 194E-B250 | 194E-F250 | — | A | — | A | A |
| 194E-B315 | 194E-F315 | — | A | — | A | A |
| Aux. switch blocks | Z | Z | Z | Z | Z | |
| Ground terminal | Z | Z | Z | Z | Z | |
| Neutral terminal | Z | Z | Z | Z | Z | |
| A = Certified | ||||||
| Z = accessories are covered by the approval for the switch | ||||||