Dedicated Function Motor Protection Relays

Click to enlarge - Supp-5_1-1


MachineAlert Relays

The MachineAlert Relays family of dedicated function electronic motor protection relays offers state-of-the-art supplementary protective functions that are easily added and applied to motor control circuits. MachineAlert Relays are an economical choice for protecting equipment investments and minimizing production downtime. To meet specific application requirements, a full range of products allows selective addition of protective enhancing functions for both motors and equipment.


Product Overview

Description

Electronic Design


Enhanced Protection


Easy to Use


  Features Typical Applications
Product Overview
Bulletin 809S
Current Monitors
  • undercurrent, overcurrent, current imbalance, phase loss
  • Three versions available

  • Programmable relay trip and reset level settings

  • Programmable relay trip and reset delay settings

  • Automatic reset

  • Three-phase version includes current imbalance and phase loss
  • Conveyors

  • Cutting and drilling machines

  • Pumps

  • Mixers
  • Product Overview
    Bulletin 813S
    Phase Monitors
  • phase loss, under/overvoltage, phase imbalance, phase sequence
  • Independent programmable trip settings for undervoltage, overvoltage, and phase imbalance

  • Programmable relay trip and reset delay settings

  • RMS voltage monitoring up-to 690V AC

  • Pre-start as well as running protection

  • Automatic reset

  • 1 N.O. and 1 changeover contact
  • Pumps

  • Fans

  • Blowers

  • Compressors
  • Product Overview
    Bulletin 817
    Thermistor Monitors
  • overtemperature
  • Two versions available

  • Connection of up-to six PTC thermistors in series

  • Open and short circuit detection

  • Short circuit protected signal input

  • Automatic, manual and remote reset options available

  • Status indication LEDs
  • VFD Controlled Motors

  • Transformers

  • Bearings

  • Heating systems
  • Product Overview
    Bulletin 819
    Motor Rotation Monitors
  • zero speed detection
  • Zero speed monitoring through evaluation of the feedback voltage of a decelerating motor

  • Standstill monitoring by means of a pulse generator, tachometer, etc.

  • Frequency monitoring for signals of any curve form in the range of 16…100V
  • p-p
  • Programmable relay trip and reset settings

  • Programmable time delay settings
  • Conveyors

  • Centrifuges

  • Band saws

  • Grinders

  • Product Family Overview

    Features⋆  Bulletin 809S
    Current Monitors
    Bulletin 813S
    Phase
    Monitors
    Bulletin 817
    Thermistor Monitors
    Bulletin 819
    Motor Rotation Monitors
    E1 E2 E2 E1 E2 E1 E2
    Under- and overcurrent protection S S
    Under- and overvoltage protection S S
    Phase imbalance and phase loss protection voltage
    based
    Phase sequence protection S
    Overtemperature protection S S
    Speed detection via frequency input S  
    Speed detection evaluation of motor feedback voltage S S
    Operating Range 0.5…5 A
    1.0…24.9V
    10…249V
    2.0…15.0 A 500V AC
    or 690V AC
    IEC 400V AC
    CSA/UL 300V AC
    IEC 690V AC
    CSA/UL 600V AC
    Case size (mm) 22.5 45 45 22.5 22.5 22.5 45
    LCD / keypad S S S S S
    LED Status Indicator S S
    Automatic reset S S S S O S S
    Manual reset O
    Remote reset O
    Changeover contacts (SPDT) 1 1 1 1
    N.O. contacts 1 1 2 2
    (independent)
    2
    (independent)
    1
    No setting required S S
    Programmable trip level, reset level and time delay settings S S S S S
    Trip cause identification S S S
    Measuring Circuit Monitoring (open, short) S S S S
      
    ⋆ S= Standard
    O= Option

    Standards Compliance and Certifications

    Standards Compliance—Bulletins 809S/813S/819

    EN 60255-5, EN50263
    CSA C22.2, No.14
    UL 508


    CE
    cULus Listed


    Standards Compliance—Bulletin 817

    IEC 255-8, IEC 292-1
    IEC 255-4, IEC 69
    SEV, SEN 36 1503
    CSA C22.2, No. 14
    UL 508


    Certifications—Bulletins 809S/813S/819

    cULus Listed (File E14840, Guide NKCR, NKCR7)

    Certifications—Bulletin 817

    cURus Recognized (File 33916, Guide NKCR2, NKCR8)
    SEV
    NEMKO
    FI


    Product Selection

    Motor Protection Relay Type Description Cat. No.
    Bulletin 809S Current Monitors 0.5…5 A AC/DC (1-phase), 2.0…24.9V or 20…249V AC/DC 50/60 Hz 809S-E1Ä
    2.0…15 A AC/DC (1-phase) 809S-E2ĵ
    Bulletin 813S Phase Monitors Monitoring Range 150…500V AC 813S-E2Bĵ
    Monitoring Range 250…690V AC 813S-E2Cĵ
    Bulletin 817 Thermistor Monitors Automatic Reset 817-E1⋆ 
    Automatic, manual or remote reset, status storage 817-E2⋆ 
    Bulletin 819 Motor Speed Monitors Max. Monitored Voltage 400V AC max. (IEC), 300V AC max. (CSA/UL), or Frequency Monitoring for signals of any curve form in the range 16…100Vp-p 819-E1Ä
    Max. Monitored Voltage 690V AC max. (IEC), 600V AC max. (CSA/UL) 819-E2Ä
      
    Package Quantity = 1
    ⋆ Rated supply voltage of 24…240V AC/DC.

    Ä Supply Voltage Suffix Code

    The Cat. No. as listed is incomplete. Select a Supply Voltage Suffix Code from the table below to complete the Cat. No.
    Example: Cat. No. 809S-E1Ä becomes 809S-E1D.


    Voltage Rating 24V DC 115V AC 230V AC
      ZJ D A
      

    µ Frequency Code

    The Cat. No. as listed is incomplete. Select a Frequency Code from the table below to complete the Cat. No.
    Example: Cat. No. 813S-E2BDµ becomes 813S-E2BD60.


    Frequency Rating 50 Hz 60 Hz
      50 60
      

    Current Transformers

    Use only with Cat No. 809S-E1.

    Trip Current Range
    Continuous AC Amperes
    (5 A Secondary Winding)
    Maximum Current [A] Cat. No.
    Continuous Inrush
    4.2…50 75 350 809S-CT1
    17…200 300 1400 809S-CT2
    42…500 750 3500 809S-CT3
    100…1200 1800 8400 809S-CT4
      

    Specifications

    Programmable Settings
    Setting Recommended
    Adjustment Range
    809S-E1
    Actuation Value, Current 0.5…5.0 A
    Release Value, Current 0.5…5.0 A
    Actuation Value, Voltage 1.0…24.9V/10…249V
    Release Value, Voltage 1.0…24.9V/10…249V
    Delay 0.0…24.9 s
    809S-E2
    Actuation Value, Imbalance 5…35%
    Release Value, Imbalance 5…35%
    Delay, Relay Energize 0.0…24.9 s
    Delay, Relay De-energize 0.0…24.9 s
    813S-E2
    Overvoltage Level (E2B/E2C) 150…500V AC/250…700V AC
    Undervoltage Level (E2B/E2C) 150…500V AC/250…700V AC
    % Imbalance Level 5…19%
    Delay, Relay Energize 0.0…24.9 s
    Delay, Relay De-energize 0.0…24.9 s
    819-E1
    Actuation Value, Voltage 1.0…24.9V AC
    Release Value, Voltage 1.0…24.9V AC
    Actuation Value, Frequency 10…249 Hz
    Release Value, Frequency 10…249 Hz
    Delay 0.0…24.9 s
    819-E2
    Actuation Value, Voltage 1.0…24.9V AC
    Release Value, Voltage 1.0…24.9V AC
    Delay, Relay Energize 0.0…24.9 s
    Delay, Relay De-energize 0.0…24.9 s
      

    Bulletin 817 PTC Sensor Characteristics
    Type of control unit Mark A
    Sensor Characteristic per IEC 34-11-2
    Maximum number of sensors 6
    Maximum cold resistance of PTC sensor chain 1500 W
    Trip resistance 3600 W (±300 W)
    Reset resistance 1580 W (±60 W)
    Short circuit trip resistance <20 W (–5 W, +0 W)
    Short circuit reset resistance 24 W (–0 W, +6 W)
    Open circuit resistance >18000 W
    Bulletin 817 Power/Trip Idendification
    Power on Green
    Trip Overtemperature Red
    Trip open circuit (Sensor) Red 2 Hz
    Trip short circuit (sensor) Red “flashes”
    Bulletin 817 Measuring and Reset Lines
    Measuring Line Up to 200 parallel or twisted;
    >200 m shielded,
    shield connected with T1
    Minimum Cross Section (mm2) 0.5
    0.75
    1
    1.5
    Maximum Line length (m) 200
    300
    400
    600
    Remote reset Max 600 m;
    Up to 200 parallel or twisted;
    >200 m shielded,
    shield connected with r1
      

    Bulletin 817 Relay Configuration
      817-E1 817-E2
      Click to enlarge - 817_e1-relay-config Click to enlarge - 817_e2-relay-config
    Normal Click to enlarge - e1-normal Click to enlarge - e2-normal
    Tripped Click to enlarge - e1-tripped Click to enlarge - e2-tripped
    Power Off Click to enlarge - e1-power_off Click to enlarge - e2-power_off
      

    Dedicated Function Relays, 809S-E1 to 813S-E2

    Dedicated Function Relays
      809S-E1 809S-E2 813S-E2
    ELECTRICAL
    Main
    Rated Insulation Voltage (Ui) 250V AC 690V AC 690V AC
    Rated Operating Voltage (Ue) IEC: 250V AC
    CSA/UL: 250V AC
    IEC: 690V AC
    CSA/UL: 600V AC
    IEC: 690V AC
    CSA/UL: 600V AC
    Measurement Range 0.5...5 A AC/DC
    1…24.9V
    10...249V AC/DC
    1...15 A AC/DC E2B: 500V
    E2C: 690V
    Accuracy ±5% ±5% ±5%
    Number of Phases 1 1 3
    Supply
    Rated Supply Voltage (Us) 24V DC
    115V AC,
    230V AC
    24V DC
    115V AC,
    230V AC
    24V DC
    115V AC,
    230V AC
    Operating Range AC: 0.8…1.1 Us
    DC: 0.85…1.1 Us
    AC: 0.8…1.1 Us
    DC: 0.85…1.1 Us
    AC: 0.8…1.1 Us
    DC: 0.85…1.1 Us
    Maximum Power Consumption 1 VA 2 VA 2 VA
    Output Relay
    Type of Contacts (1) Form C (1) Form A
    (1) Form C
    (1) Form A
    (1) Form C
    Rated Operating Current 5 A @ 250V AC
    4 A @ 24V DC
    5 A @ 250V AC
    4 A @ 24V DC
    5 A @ 250V AC
    4 A @ 24V DC
    Utilization Category AC1, DC1 AC1, DC1 AC1, DC1
    MECHANICAL
    Environmental
    Ambient Temperature (storage) –20…+80 °C –20…+80 °C –20…+80 °C
    (operating) –5…+60 °C –5…+60 °C –5…+60 °C
    Humidity 5…95%
    non-condensing
    5…95%
    non-condensing
    5…95%
    non-condensing
    Maximum Altitude 2000 m 2000 m 2000 m
    Pollution Environment Pollution Degree 2 Pollution Degree 2 Pollution Degree 2
    Degree of Protection IP20 IP20 IP20
    Terminal Cross-Sections
    Terminal Screws M3 M3 M3
    Conductor Size 0.2…2.5 mm2
    26…14 AWG
    0.2…2.5 mm2
    22…12 AWG
    0.2…2.5 mm2
    22…12 AWG
      

    Dedicated Function Relays, 817-E1 to 819-E2

    Dedicated Function Relays
      817-E1 817-E2 819-E1 819-E2
    ELECTRICAL
    Main
    Rated Insulation Voltage (Ui) 250V AC 250V AC 400V AC 690V AC
    Rated Operating Voltage (Ue) IEC: 250V AC
    CSA/UL: 250V AC
    IEC: 250V AC
    CSA/UL: 250V AC
    IEC: 400V AC
    CSA/UL: 300V AC
    IEC: 690V AC
    CSA/UL: 600V AC
    Measurement Range Freq: 10…249 Hz
    (16…100Vp-p)
    Back-EMF: 1.0…24.9V
    Back-EMF: 1.0…24.9V
    Accuracy ±5% ±5%
    Number of Phases 1 1
    Supply
    Rated Supply Voltage (Us) 24…240V AC/DC 24…240V AC/DC 24V DC, 115V AC, 230V AC 24V DC, 115V AC, 230V AC
    Operating Range 0.8…1.1 Us 0.8…1.1 Us AC: 0.8…1.1 Us
    DC: 0.85…1.1 Us
    AC: 0.8…1.1 Us
    DC: 0.85…1.1 Us
    Maximum Power Consumption 1.5 VA 1.5 VA 1 VA 2 VA
    Output Relay
    Type of Contacts (2) Form A
    dependent
    (2) Form A
    independent
    (2) Form A
    independent
    (1) Form A
    (1) Form C
    Rated Operating Current 3 A @ 120V AC
    1.5 A @ 240V AC
    3 A @ 120V AC
    1.5 A @ 240V AC
    5 A @ 250V AC
    4 A @ 24V DC
    5 A @ 250V AC
    4 A @ 24V DC
    Utilization Category AC15, DC13 AC15, DC13 AC1, DC1 AC1, DC1
    MECHANICAL
    Environmental
    Ambient Temperature (storage) –40…+80 °C –40…+80 °C –20…+80 °C –20…+80 °C
    (operating) –25…+60 °C –25…+60 °C –5…+60 °C –5…+60 °C
    Humidity 5…95%
    non-condensing
    5…95%
    non-condensing
    5…95%
    non-condensing
    5…95%
    non-condensing
    Maximum Altitude 2000 m 2000 m 2000 m 2000 m
    Pollution Environment Pollution Degree 2 Pollution Degree 2 Pollution Degree 2 Pollution Degree 2
    Degree of Protection IP20 IP20 IP20 IP20
    Terminal Cross-Sections
    Terminal Screws     M3 M3
    Conductor Size 0.5…2.5 mm2
    20…12 AWG
    0.5…2.5 mm2
    20…12 AWG
    0.2…2.5 mm2
    26…14 AWG
    0.2…2.5 mm2
    22…12 AWG
      

    Function and Wiring Diagrams

    809S-E1 Wiring Diagram

    Click to enlarge - 41053-233_circt_diag


    809S-E1 Function Diagram

    Click to enlarge - 41053-233_fnct_diag_a


    Click to enlarge - 41053-233_fnct_diag_b


    819-E1 Wiring Diagram

    Click to enlarge - 41053-234_circt_diag


    819-E1 Function Diagram

    Click to enlarge - 41053-234_fnct_diag_a


    Click to enlarge - 41053-234_fnct_diag_b


    Click to enlarge - 41053-234_fnct_diag_c


    809S-E2 Wiring Diagram

    Click to enlarge - 41053-235_circt_diag


    809S-E2 Function Diagram

    Click to enlarge - 41053-235_fnct_diag_a


    Click to enlarge - 41053-235_fnct_diag_b


    819-E2 Wiring Diagram

    Click to enlarge - 41053-236_circt_diag


    819-E2 Function Diagram

    Click to enlarge - 41053-236_fnct_diag_a


    Click to enlarge - 41053-236_fnct_diag_b


    Click to enlarge - 41053-236_fnct_diag_c


    813S-E2 Wiring Diagram

    Click to enlarge - 41053-237_circt_diag


    813S-E2 Function Diagram

    Click to enlarge - 41053-237_fnct_diag

    Approximate Dimensions

    Dimensions shown are in millimeters (inches) Dimensions are not intended for manufacturing purposes.

    809S-E1, 819-E1

    Click to enlarge - 809S_813S_817_819-5_12-1


    809S-E2, 813S-E2, 819-E2

    Click to enlarge - 809S_813S_817_819-5_12-2


    Dimensions shown are in millimeters (inches) Dimensions are not intended for manufacturing purposes.

    817-E1, 817-E2

    Click to enlarge - 809S_813S_817_819-5_13-1


    809S-CT1, 809S-CT2, 809S-CT3, 809S-CT4

    Use only with Cat. Nos. 809S-E1 and 809S-E2

    Click to enlarge - 809S_813S_817_819-5_13-2


    Cat. No. A
    Min.
    B C D E F
    809S-CT1 32
    (1-1/4)
    102
    (4)
    117
    (4-5/8)
    95.5
    (3-3/4)
    32
    (1-1/4)
    6.4
    (1/4)
    809S-CT2
    809S-CT3 57
    (2-1/4)
    149
    (5-7/8)
    181
    (7-1/8)
    127
    (5)
    38
    (1-1/2)
    7.1
    (9/32)
    809S-CT4 95.5
    (3-3/4)
    171
    (6-3/4)
    198
    (7-25/32)
    165
    (6-1/2)
    41.5
    (1-5/8)
    7.1