Bulletin 284 ArmorStart Distributed Motor Controller

Product Overview


Click to enlarge - 280_Armorstart_VFD_1hp_4c


Bulletin 284 ArmorStart Distributed Motor Controller


Standards Compliance and Certifications

Standards Compliance

UL 508C
CSA C22.2, No. 14
EN/IEC 60947-4-2, EN 50178, EN 61800-3
CE Marked per Low Voltage Directive 2006/95/EC and EMC Directive 2004/108/EC
CCC
ODVA for EtherNet/IP and DeviceNet


Certifications

cULus (File No. E207834, Guide NMMS, NMMS7)

Mode of Operation

Sensorless Vector Performance (SVP) - V/Hz

This method provides excellent speed regulation and high levels of torque across the entire speed range of the drive, and improved speed regulation even as loading increases. Basic control yields the most cost-effective performance when sensorless vector control is not required.

Click to enlarge - 284_SVP_hs_graph


  • Automatically provides auto boost (IR compensation) and slip compensation.


  • Sensorless Vector Control (SVC)

    Sensorless vector control provides exceptional speed regulation and very high levels of torque across the entire speed range of the drive.

    Click to enlarge - 284_SVC_sv_graph


  • The Autotune feature allows the Bulletin 284 (SVC) to adapt to individual motor characteristics.


  • Timer, Counter, Basic Logic and StepLogic™ functions can reduce hardware design costs and simplify control schemes.


  • Develops high torque over a wide speed range and adapts to individual motor characteristics.


  • Additional Features


    Overload Protection

    The Bulletin 284 ArmorStart Distributed Motor Controller incorporates, as standard, electronic motor overload protection. This overload protection is accomplished electronically with an I2t algorithm. The ArmorStart’s overload protection is programmable via the communication network providing the user with flexibility. The overload trip class allows for class 10 overload protection. Ambient insensitivity is inherent in the electronic design of the overload.

    Fault Diagnostics

    Fault diagnostics capabilities built into the Bulletin 284 ArmorStart Distributed Motor Controller help you pinpoint a problem for easy troubleshooting and quick re-starting.



    Local Logic via DeviceLogix

    Provides local control over the device’s discrete and network I/O. DeviceLogix consists of function blocks, inputs, outputs, and actual hardware data, including fault and status bits.

    Factory-Installed Options

    HOA Selector Keypad with Jog Function

    The HOA Selector Keypad with Jog Function allows for local start/stop control with capabilities to JOG and to Forward/Reverse motor direction.

    EMI Filter

    The EMI Filter is required to be CE compliant. When selected, a 3–meter shielded 4–conductor motor cordset is provided as standard. This is only available with sensorless vector control.

    Control Brake Connector

    An internal contactor is used to switch an electromechanical motor brake On/Off. The motor brake is powered from the control power circuit. The configuration of the R1 relay controls the function of the brake. A customer accessible 3 A fuse is provided to protect the brake cable. Included is a 3-meter 3-pin cordset for connection to the motor brake as standard.

    Source Brake Contactor

    An internal contactor is used to switch an electromechanical motor brake On/Off. The motor brake is powered from the line power circuit. The configuration of the R1 relay controls the function of the brake. A customer accessible 3 A fuse is provided to protect the brake cable. Included is a 3-meter 3-pin cordset for connection to the motor brake as standard.

    Shielded Motor Cable

    A 3-meter shielded 4-conductor cordset is provided instead of the 3-meter unshielded 4-conductor cordset, when the EMI Filter is selected.

    IP67 Dynamic Brake Connector

    The IP67 Dynamic Brake Resistor design offers simplicity in wiring and installation. The DB1 option must be selected in order to have the quick disconnect connectivity. See accessories for available IP67 Dynamic Brake Resistors.

    Output Contactor

    An internal contactor is sourced from control voltage to isolate the load side of the VFD. Control voltage or the at-motor disconnect controls the ON/OFF of the output contactor. A sequenced stop involving the output contact cannot be performed.

    Safety Monitor

    The Safety Monitor Option allows for independent monitoring of the output contactor status. The output contactor is provided as standard with this option. The function is implemented using the normally closed auxiliary contact which complies with
    IEC 60947-5-1 for mechanically linked contacts. Two terminal blocks are provided as inputs to an external device, such as a safety circuit.


    0…10V Analog Input Connector

    This provides 0…10V analog input as an external frequency command from the analog input or remote potentiometer. A 5-pin micro receptacle is provided for connectivity. A shielded 5-conductor cordset or patch cord is recommended.

    Catalog Number Explanation

    Sensorless Vector Performance (SVP), typical of Powerflex 4 Class Drive

    284   D F   H   D2P3   D 10 CR Option 1 Option 2 Option 3
    a    b    c    d    e    f    g    h    i    j    k

    a
    Bulletin Number
    Code Description
    284 VFD Starter

    b
    Communications
    Code Description
    D DeviceNet
    A ArmorPoint

    c
    Enclosure Type
    Code Description
    F Type 4 (IP67)
    S Type 4X

    d
    Torque Performance Mode
    Code Description
    H Volts per Hertz (Sensorless Vector Performance)

    e
    Output Current
    200…240V 380…480V
    Code Description Code Description
    B2P3 2.3 A, 0.4 kW, 0.5 Hp D1P4 1.4 A, 0.4 kW, 0.5 Hp
    B4P5 4.5 A, 0.75 kW, 1.0 Hp D2P3 2.3 A, 0.75 kW, 1.0 Hp
    B7P6 7.6 A, 1.5 kW, 2.0 Hp D4P0 4.0 A, 1.5 kW, 2.0 Hp
    D6P0 6.0 A, 2.2 kW, 3.0 Hp
    D7P6 7.6 A, 3.3 kW, 5.0 Hp

    f
    Control Voltage
    Code Description
    Z 24V DC
    D 120V AC
    B 240V AC

    g
    Short Circuit Protection
    (Motor Circuit Protector)
    Code Description
    10 10 A Rated Device
    25 25 A Rated Device

    h
    Control and 3-Phase Power Connections / Motor Cable Connection
    (CR: Conduit/Round Media) or (RR: Round/Round Media)

    Code
    Description
    Control Power 3-Phase Power Motor Cable
    CR blank Conduit Entrance Conduit Entrance 3 m, unshielded cordset male 90°
    CR N Conduit Entrance Conduit Entrance 3 m, shielded cordset male 90°
    CR W ⋆  Conduit Entrance Conduit Entrance No cable
    RR blank Round Media (Male Receptacle) Round Media (Male Receptacle) 3 m, unshielded cordset male 90°
    RR N Round Media (Male Receptacle) Round Media (Male Receptacle) 3 m, shielded cordset male 90°
    RR W ⋆  Round Media (Male Receptacle) Round Media (Male Receptacle) No cable

    i
    Option 1
    Code Description
    3 Hand/Off/Auto Selector Keypad with Jog Function

    j
    Option 2
    Code Description
    CB blank Control Brake Contactor
    CB W ⋆  No cable
    DB blank DB Brake Connector
    SB blank Source Brake Contactor
    SB W ⋆  No cable

    k
    Option 3
    Code Description
    OC Output Contactor
    SM ‡ §  Safety Monitor

    ⋆ See Accessories on Motor and Brake Cables for extended motor and brake cable lengths.
    ‡ The output contactor is included with the Safety Monitor option.
    § Not available with round media option (RR).


    Product Selection

    Build a Catalog Number


    DeviceNet Network Communication

    IP67/NEMA Type 4 with conduit entrance, Volts per Hertz (SVP) torque performance, Up to 480V AC

    Input Voltage 3-Phase kW Rating 3-Phase Hp Rating Output Current [A] 24V DC
    Control Voltage
    120V AC
    Control Voltage
    240V AC
    Control Voltage
    Cat. No. Cat. No. Cat. No.
    200...240V, 50/60 Hz
    3-Phase
    0.4 0.5 2.3 284D-FHB2P3Z-10-CR 284D-FHB2P3D-10-CR 284D-FHB2P3B-10-CR
    0.75 1 4.5 284D-FHB4P5Z-10-CR 284D-FHB4P5D-10-CR 284D-FHB4P5B-10-CR
    1.5 2 7.6 284D-FHB7P6Z-25-CR 284D-FHB7P6D-25-CR 284D-FHB7P6B-25-CR
    380...480V, 50/60 Hz
    3-Phase
    0.4 0.5 1.4 284D-FHD1P4Z-10-CR 284D-FHD1P4D-10-CR 284D-FHD1P4B-10-CR
    0.75 1 2.3 284D-FHD2P3Z-10-CR 284D-FHD2P3D-10-CR 284D-FHD2P3B-10-CR
    1.5 2 4 284D-FHD4P0Z-10-CR 284D-FHD4P0D-10-CR 284D-FHD4P0B-10-CR
    2.2 3 6 284D-FHD6P0Z-25-CR 284D-FHD6P0D-25-CR 284D-FHD6P0B-25-CR
    3 5 7.6 284D-FHD7P6Z-25-CR 284D-FHD7P6D-25-CR 284D-FHD7P6B-25-CR
      

    IP67/NEMA Type 4 with quick disconnects for ArmorConnect power media, Volts per Hertz (SVP) torque performance, Up to 480V AC

    Input Voltage 3-Phase kW Rating 3-Phase Hp Rating Output Current [A] 24V DC
    Control Voltage
    120V AC
    Control Voltage
    240V AC
    Control Voltage
    Cat. No. Cat. No. Cat. No.
    200…240V, 50/60 Hz
    3-Phase
    0.4 0.5 2.3 284D-FHB2P3Z-10-RR 284D-FHB2P3D-10-RR 284D-FHB2P3B-10-RR
    0.75 1 4.5 284D-FHB4P5Z-10-RR 284D-FHB4P5D-10-RR 284D-FHB4P5B-10-RR
    1.5 2 7.6 284D-FHB7P6Z-25-RR 284D-FHB7P6D-25-RR 284D-FHB7P6B-25-RR
    380…480V, 50/60 Hz
    3-Phase
    0.4 0.5 1.4 284D-FHD1P4Z-10-RR 284D-FHD1P4D-10-RR 284D-FHD1P4B-10-RR
    0.75 1 2.3 284D-FHD2P3Z-10-RR 284D-FHD2P3D-10-RR 284D-FHD2P3B-10-RR
    1.5 2 4 284D-FHD4P0Z-10-RR 284D-FHD4P0D-10-RR 284D-FHD4P0B-10-RR
    2.2 3 6 284D-FHD6P0Z-25-RR 284D-FHD6P0D-25-RR 284D-FHD6P0B-25-RR
    3 5 7.6 284D-FHD7P6Z-25-RR 284D-FHD7P6D-25-RR 284D-FHD7P6B-25-RR
      

    NEMA Type 4X with conduit entrance, Volts per Hertz (SVP) torque performance, Up to 480V AC

    Input Voltage 3-Phase kW Rating 3-Phase Hp Rating Output Current [A] 24V DC
    Control Voltage
    120V AC
    Control Voltage
    240V AC
    Control Voltage
    Cat. No. Cat. No. Cat. No.
    200…240V, 50/60 Hz
    3-Phase
    0.4 0.5 2.3 284D-SHB2P3Z-10-CR 284D-SHB2P3D-10-CR 284D-SHB2P3B-10-CR
    0.75 1 4.5 284D-SHB4P5Z-10-CR 284D-SHB4P5D-10-CR 284D-SHB4P5B-10-CR
    1.5 2 7.6 284D-SHB7P6Z-25-CR 284D-SHB7P6D-25-CR 284D-SHB7P6B-25-CR
    380…480V, 50/60 Hz
    3-Phase
    0.4 0.5 1.4 284D-SHD1P4Z-10-CR 284D-SHD1P4D-10-CR 284D-SHD1P4B-10-CR
    0.75 1 2.3 284D-SHD2P3Z-10-CR 284D-SHD2P3D-10-CR 284D-SHD2P3B-10-CR
    1.5 2 4 284D-SHD4P0Z-10-CR 284D-SHD4P0D-10-CR 284D-SHD4P0B-10-CR
    2.2 3 6 284D-SHD6P0Z-25-CR 284D-SHD6P0D-25-CR 284D-SHD6P0B-25-CR
    3 5 7.6 284D-SHD7P6Z-25-CR 284D-SHD7P6D-25-CR 284D-SHD7P6B-25-CR
      

    NEMA Type 4X with quick disconnects for ArmorConnect power media, Volts per Hertz (SVP) torque performance, Up to 480V AC

    Input Voltage 3-Phase kW Rating 3-Phase Hp Rating Output Current [A] 24V DC
    Control Voltage
    120V AC
    Control Voltage
    240V AC
    Control Voltage
    Cat. No. Cat. No. Cat. No.
    200…240V, 50/60 Hz
    3-Phase
    0.4 0.5 2.3 284D-SHB2P3Z-10-RR 284D-SHB2P3D-10-RR 284D-SHB2P3B-10-RR
    0.75 1 4.5 284D-SHB4P5Z-10-RR 284D-SHB4P5D-10-RR 284D-SHB4P5B-10-RR
    1.5 2 7.6 284D-SHB7P6Z-25-RR 284D-SHB7P6D-25-RR 284D-SHB7P6B-25-RR
    380…480V, 50/60 Hz
    3-Phase
    0.4 0.5 1.4 284D-SHD1P4Z-10-RR 284D-SHD1P4D-10-RR 284D-SHD1P4B-10-RR
    0.75 1 2.3 284D-SHD2P3Z-10-RR 284D-SHD2P3D-10-RR 284D-SHD2P3B-10-RR
    1.5 2 4 284D-SHD4P0Z-10-RR 284D-SHD4P0D-10-RR 284D-SHD4P0B-10-RR
    2.2 3 6 284D-SHD6P0Z-25-RR 284D-SHD6P0D-25-RR 284D-SHD6P0B-25-RR
    3 5 7.6 284D-SHD7P6Z-25-RR 284D-SHD7P6D-25-RR 284D-SHD7P6B-25-RR
      

    ArmorPoint Bus Network Communication

    IP67/NEMA Type 4 with conduit entrance, Volts per Hertz (SVP) torque performance, Up to 480V AC

    Input Voltage 3-Phase kW Rating 3-Phase Hp Rating Output Current [A] 24V DC
    Control Voltage
    120V AC
    Control Voltage
    240V AC
    Control Voltage
    Cat. No. Cat. No. Cat. No.
    200…240V, 50/60 Hz
    3-Phase
    0.4 0.5 2.3 284A-FHB2P3Z-10-CR 284A-FHB2P3D-10-CR 284A-FHB2P3B-10-CR
    0.75 1 5 284A-FHB4P5Z-10-CR 284A-FHB4P5D-10-CR 284A-FHB4P5B-10-CR
    1.5 2 7.6 284A-FHB7P6Z-25-CR 284A-FHB7P6D-25-CR 284A-FHB7P6B-25-CR
    380…480V, 50/60 Hz
    3-Phase
    0.4 0.5 1.4 284A-FHD1P4Z-10-CR 284A-FHD1P4D-10-CR 284A-FHD1P4B-10-CR
    0.75 1 2.3 284A-FHD2P3Z-10-CR 284A-FHD2P3D-10-CR 284A-FHD2P3B-10-CR
    1.5 2 4 284A-FHD4P0Z-10-CR 284A-FHD4P0D-10-CR 284A-FHD4P0B-10-CR
    2.2 3 6 284A-FHD6P0Z-25-CR 284A-FHD6P0D-25-CR 284A-FHD6P0B-25-CR
    3 5 7.6 284A-FHD7P6Z-25-CR 284A-FHD7P6D-25-CR 284A-FHD7P6B-25-CR
      

    IP67/NEMA Type 4 with quick disconnects for ArmorConnect power media, Volts per Hertz (SVP) torque performance, Up to 480V AC

    Input Voltage 3-Phase kW Rating 3-Phase Hp Rating Output Current [A] 24V DC
    Control Voltage
    120V AC
    Control Voltage
    240V AC
    Control Voltage
    Cat. No. Cat. No. Cat. No.
    200…240V, 50/60 Hz
    3-Phase
    0.4 0.5 2.3 284A-FHB2P3Z-10-RR 284A-FHB2P3D-10-RR 284A-FHB2P3B-10-RR
    0.75 1 4.5 284A-FHB4P5Z-10-RR 284A-FHB4P5D-10-RR 284A-FHB4P5B-10-RR
    1.5 2 7.6 284A-FHB7P6Z-25-RR 284A-FHB7P6D-25-RR 284A-FHB7P6B-25-RR
    380…480V, 50/60 Hz
    3-Phase
    0.4 0.5 1.4 284A-FHD1P4Z-10-RR 284A-FHD1P4D-10-RR 284A-FHD1P4B-10-RR
    0.75 1 2.3 284A-FHD2P3Z-10-RR 284A-FHD2P3D-10-RR 284A-FHD2P3B-10-RR
    1.5 2 4 284A-FHD4P0Z-10-RR 284A-FHD4P0D-10-RR 284A-FHD4P0B-10-RR
    2.2 3 6 284A-FHD6P0Z-25-RR 284A-FHD6P0D-25-RR 284A-FHD6P0B-25-RR
    3 5 7.6 284A-FHD7P6Z-25-RR 284A-FHD7P6D-25-RR 284A-FHD7P6B-25-RR
      

    Catalog Number Explanation

    Sensorless Vector Control (SVC), typical of Powerflex 40 Class Drive

    284 D F V D2P3 D 10 CR Option 1 Option 2 Option 3
    a b    c d e f    g    h    i    j    k

    a
    Bulletin Number
    Code Description
    284 VFD Starter

    b
    Communications
    Code Description
    E EtherNet/IP
    D DeviceNet
    A ArmorPoint

    c
    Enclosure Type
    Code Description
    F Type 4 (IP67)
    S‡  Type 4X

    d
    Torque Performance Mode
    Code Description
    V Sensorless Vector Control and Volts per Hertz

    e
    Output Current
    200…240V‡  380…480V 500…600V‡ 
    Code Description Code Description Code Description
    B2P3 2.3 A, 0.4 kW, 0.5 Hp D1P4 1.4 A, 0.4 kW, 0.5 Hp E1P7 1.7 A, 0.75 kW, 1.0 Hp
    B5P0 5.0 A, 0.75 kW, 1.0 Hp D2P3 2.3 A, 0.75 kW, 1.0 Hp E3P0 3.0 A, 1.5 kW, 2.0 Hp
    B7P6 7.6 A, 1.5 kW, 2.0 Hp D4P0 4.0 A, 1.5 kW, 2.0 Hp E4P2 4.2 A, 2.2 kW, 3.0 Hp
    D6P0 6.0 A, 2.2 kW, 3.0 Hp E6P6 6.6 A, 4.0 kW, 5.0 Hp
    D7P6 7.6 A, 3.3 kW, 5.0 Hp

    f
    Control Voltage
    Code Description
    Z 24V DC
    D‡  120V AC
    B‡  240V AC

    g
    Short Circuit Protection (Motor Circuit Protector)
    Code Description
    10 10 A Rated Device
    25 25 A Rated Device

    h
    Control and 3-Phase Power Connections / Motor Cable Connection
    (CR: Conduit/Round Media) or (RR: Round/Round Media)

    Code
    Description
    Control Power 3-Phase Power Motor Cable
    CR blank Conduit Entrance Conduit Entrance 3 m, unshielded cordset male 90°
    CR N Conduit Entrance Conduit Entrance 3 m, shielded cordset male 90°
    CR W ⋆  Conduit Entrance Conduit Entrance No cable
    RR blank Round Media (Male Receptacle) Round Media (Male Receptacle) 3 m, unshielded cordset male 90°
    RR N Round Media (Male Receptacle) Round Media (Male Receptacle) 3 m, shielded cordset male 90°
    RR W ⋆  Round Media (Male Receptacle) Round Media (Male Receptacle) No cable

    i
    Option 1
    Code Description
    3 Hand/Off/Auto Selector Keypad with Jog Function

    j
    Option 2
    Code Description
    CB‡  blank Control Brake Contactor
    CB‡  W ⋆  No cable
    DB blank DB Brake Connector
    SB blank Source Brake Contactor
    SB W ⋆  No cable

    k
    Option 3
    Code Description
    A10‡  0…10V Analog Input
    EMI EMI Filter
    OC Output Contactor
    SM‡ § ♣  Safety Monitor

    ⋆ See Accessories on Motor and Brake Cables for extended motor and brake cable lengths.
    ‡ Not available with EtherNet/IP.
    § Not available with round media option (RR).
    ♣ The output contactor is included with the Safety Monitor option.


    Product Selection

    Build a Catalog Number


    EtherNet/IP Network Communication

    IP67/NEMA Type 4 with conduit entrance, Sensorless Vector Control, and Volts per Hertz torque performance, Up to 480V AC

    Input Voltage 3-Phase kW Rating 3-Phase Hp Rating Output Current [A] 24V DC Control Voltage
    Cat. No.
    380...480V, 50/60 Hz
    3-Phase
    0.4 0.5 1.4 284E-FVD1P4Z-10-CR
    0.75 1 2.3 284E-FVD2P3Z-10-CR
    1.5 2 4 284E-FVD4P0Z-10-CR
    2.2 3 6 284E-FVD6P0Z-25-CR
    3 5 7.6 284E-FVD7P6Z-25-CR
      

    IP67/NEMA Type 4 with quick disconnects for ArmorConnect power media, Sensorless Vector Control, and Volts per Hertz torque performance, Up to 480V AC

    Input Voltage 3-Phase kW Rating 3-Phase Hp Rating Output Current [A] 24V DC Control Voltage
    Cat. No.
    380…480V, 50/60 Hz
    3-Phase
    0.4 0.5 1.4 284E-FVD1P4Z-10-RR
    0.75 1 2.3 284E-FVD2P3Z-10-RR
    1.5 2 4 284E-FVD4P0Z-10-RR
    2.2 3 6 284E-FVD6P0Z-25-RR
    3 5 7.6 284E-FVD7P6Z-25-RR
      

    DeviceNet Network Communication

    IP67/NEMA Type 4 with conduit entrance, Sensorless Vector Control, and Volts per Hertz torque performance, Up to 575V AC

    Input Voltage 3-Phase kW Rating 3-Phase Hp Rating Output Current [A] 24V DC
    Control Voltage
    120V AC
    Control Voltage
    240V AC
    Control Voltage
    Cat. No. Cat. No. Cat. No.
    200...240V, 50/60 Hz
    3-Phase
    0.4 0.5 2.3 284D-FVB2P3Z-10-CR 284D-FVB2P3D-10-CR 284D-FVB2P3B-10-CR
    0.75 1 5 284D-FVB5P0Z-10-CR 284D-FVB5P0D-10-CR 284D-FVB5P0B-10-CR
    1.5 2 7.6 284D-FVB7P6Z-25-CR 284D-FVB7P6D-25-CR 284D-FVB7P6B-25-CR
    380...480V, 50/60 Hz
    3-Phase
    0.4 0.5 1.4 284D-FVD1P4Z-10-CR 284D-FVD1P4D-10-CR 284D-FVD1P4B-10-CR
    0.75 1 2.3 284D-FVD2P3Z-10-CR 284D-FVD2P3D-10-CR 284D-FVD2P3B-10-CR
    1.5 2 4 284D-FVD4P0Z-10-CR 284D-FVD4P0D-10-CR 284D-FVD4P0B-10-CR
    2.2 3 6 284D-FVD6P0Z-25-CR 284D-FVD6P0D-25-CR 284D-FVD6P0B-25-CR
    3 5 7.6 284D-FVD7P6Z-25-CR 284D-FVD7P6D-25-CR 284D-FVD7P6B-25-CR
    460…600V, 50/60 Hz
    3-Phase
    0.75 1 1.7 284D-FVE1P7Z-10-CR 284D-FVE1P7D-10-CR 284D-FVE1P7B-10-CR
    1.5 2 3 284D-FVE3P0Z-10-CR 284D-FVE3P0D-10-CR 284D-FVE3P0B-10-CR
    2.2 3 4.2 284D-FVE4P2Z-10-CR 284D-FVE4P2D-10-CR 284D-FVE4P2B-10-CR
    4 5 6.1 284D-FVE6P6Z-25-CR 284D-FVE6P6D-25-CR 284D-FVE6P6B-25-CR
      

    IP67/NEMA Type 4 with quick disconnects for ArmorConnect power media, Sensorless Vector Control, and Volts per Hertz torque performance, Up to 575V AC

    Input Voltage 3-Phase kW Rating 3-Phase Hp Rating Output Current [A] 24V DC
    Control Voltage
    120V AC
    Control Voltage
    240V AC
    Control Voltage
    Cat. No. Cat. No. Cat. No.
    200…240V, 50/60 Hz
    3-Phase
    0.4 0.5 2.3 284D-FVB2P3Z-10-RR 284D-FVB2P3D-10-RR 284D-FVB2P3B-10-RR
    0.75 1 5 284D-FVB5P0Z-10-RR 284D-FVB5P0D-10-RR 284D-FVB5P0B-10-RR
    1.5 2 7.6 284D-FVB7P6Z-25-RR 284D-FVB7P6D-25-RR 284D-FVB7P6B-25-RR
    380…480V, 50/60 Hz
    3-Phase
    0.4 0.5 1.4 284D-FVD1P4Z-10-RR 284D-FVD1P4D-10-RR 284D-FVD1P4B-10-RR
    0.75 1 2.3 284D-FVD2P3Z-10-RR 284D-FVD2P3D-10-RR 284D-FVD2P3B-10-RR
    1.5 2 4 284D-FVD4P0Z-10-RR 284D-FVD4P0D-10-RR 284D-FVD4P0B-10-RR
    2.2 3 6 284D-FVD6P0Z-25-RR 284D-FVD6P0D-25-RR 284D-FVD6P0B-25-RR
    3 5 7.6 284D-FVD7P6Z-25-RR 284D-FVD7P6D-25-RR 284D-FVD7P6B-25-RR
    460…600V, 50/60 Hz
    3-Phase
    0.75 1 1.7 284D-FVE1P7Z-10-RR 284D-FVE1P7D-10-RR 284D-FVE1P7B-10-RR
    1.5 2 3 284D-FVE3P0Z-10-RR 284D-FVE3P0D-10-RR 284D-FVE3P0B-10-RR
    2.2 3 4.2 284D-FVE4P2Z-10-RR 284D-FVE4P2D-10-RR 284D-FVE4P2B-10-RR
    4 5 6.1 284D-FVE6P6Z-25-RR 284D-FVE6P6D-25-RR 284D-FVE6P6B-25-RR
      

    DeviceNet Network Communication, Continued

    NEMA Type 4X with conduit entrance, Sensorless Vector Control, and Volts per Hertz torque performance, Up to 575V AC

    Input Voltage 3-Phase kW Rating 3-Phase Hp Rating Output Current [A] 24V DC
    Control Voltage
    120V AC
    Control Voltage
    240V AC
    Control Voltage
    Cat. No. Cat. No. Cat. No.
    200…240V, 50/60 Hz
    3-Phase
    0.4 0.5 2.3 284D-SVB2P3Z-10-CR 284D-SVB2P3D-10-CR 284D-SVB2P3B-10-CR
    0.75 1 5 284D-SVB5P0Z-10-CR 284D-SVB5P0D-10-CR 284D-SVB5P0B-10-CR
    1.5 2 7.6 284D-SVB7P6Z-25-CR 284D-SVB7P6D-25-CR 284D-SVB7P6B-25-CR
    380…480V, 50/60 Hz
    3-Phase
    0.4 0.5 1.4 284D-SVD1P4Z-10-CR 284D-SVD1P4D-10-CR 284D-SVD1P4B-10-CR
    0.75 1 2.3 284D-SVD2P3Z-10-CR 284D-SVD2P3D-10-CR 284D-SVD2P3B-10-CR
    1.5 2 4 284D-SVD4P0Z-10-CR 284D-SVD4P0D-10-CR 284D-SVD4P0B-10-CR
    2.2 3 6 284D-SVD6P0Z-25-CR 284D-SVD6P0D-25-CR 284D-SVD6P0B-25-CR
    3 5 7.6 284D-SVD7P6Z-25-CR 284D-SVD7P6D-25-CR 284D-SVD7P6B-25-CR
    460…600V, 50/60 Hz
    3-Phase
    0.75 1 1.7 284D-SVE1P7Z-10-CR 284D-SVE1P7D-10-CR 284D-SVE1P7B-10-CR
    1.5 2 3 284D-SVE3P0Z-10-CR 284D-SVE3P0D-10-CR 284D-SVE3P0B-10-CR
    2.2 3 4.2 284D-SVE4P2Z-10-CR 284D-SVE4P2D-10-CR 284D-SVE4P2B-10-CR
    4 5 6.1 284D-SVE6P6Z-25-CR 284D-SVE6P6D-25-CR 284D-SVE6P6B-25-CR
      

    NEMA Type 4X with quick disconnects for ArmorConnect power media, Sensorless Vector Control, and Volts per Hertz torque performance, Up to 575V AC

    Input Voltage 3-Phase kW Rating 3-Phase Hp Rating Output Current [A] 24V DC
    Control Voltage
    120V AC
    Control Voltage
    240V AC
    Control Voltage
    Cat. No. Cat. No. Cat. No.
    200…240V, 50/60 Hz
    3-Phase
    0.4 0.5 2.3 284D-SVB2P3Z-10-RR 284D-SVB2P3D-10-RR 284D-SVB2P3B-10-RR
    0.75 1 5 284D-SVB5P0Z-10-RR 284D-SVB5P0D-10-RR 284D-SVB5P0B-10-RR
    1.5 2 7.6 284D-SVB7P6Z-25-RR 284D-SVB7P6D-25-RR 284D-SVB7P6B-25-RR
    380…480V, 50/60 Hz
    3-Phase
    0.4 0.5 1.4 284D-SVD1P4Z-10-RR 284D-SVD1P4D-10-RR 284D-SVD1P4B-10-RR
    0.75 1 2.3 284D-SVD2P3Z-10-RR 284D-SVD2P3D-10-RR 284D-SVD2P3B-10-RR
    1.5 2 4 284D-SVD4P0Z-10-RR 284D-SVD4P0D-10-RR 284D-SVD4P0B-10-RR
    2.2 3 6 284D-SVD6P0Z-25-RR 284D-SVD6P0D-25-RR 284D-SVD6P0B-25-RR
    3 5 7.6 284D-SVD7P6Z-25-RR 284D-SVD7P6D-25-RR 284D-SVD7P6B-25-RR
    460…600V, 50/60 Hz
    3-Phase
    0.75 1 1.7 284D-SVE1P7Z-10-RR 284D-SVE1P7D-10-RR 284D-SVE1P7B-10-RR
    1.5 2 3 284D-SVE3P0Z-10-RR 284D-SVE3P0D-10-RR 284D-SVE3P0B-10-RR
    2.2 3 4.2 284D-SVE4P2Z-10-RR 284D-SVE4P2D-10-RR 284D-SVE4P2B-10-RR
    4 5 6.1 284D-SVE6P6Z-25-RR 284D-SVE6P6D-25-RR 284D-SVE6P6B-25-RR
      

    ArmorPoint Bus Network Communication

    IP67/NEMA Type 4 with conduit entrance, Sensorless Vector Control, and Volts per Hertz torque performance, Up to 575V AC

    Input Voltage 3-Phase kW Rating 3-Phase Hp Rating Output Current [A] 24V DC
    Control Voltage
    120V AC
    Control Voltage
    240V AC
    Control Voltage
    Cat. No. Cat. No. Cat. No.
    200…240V, 50/60 Hz
    3-Phase
    0.4 0.5 2.3 284A-FVB2P3Z-10-CR 284A-FVB2P3D-10-CR 284A-FVB2P3B-10-CR
    0.75 1 5 284A-FVB5P0Z-10-CR 284A-FVB5P0D-10-CR 284A-FVB5P0B-10-CR
    1.5 2 7.6 284A-FVB7P6Z-25-CR 284A-FVB7P6D-25-CR 284A-FVB7P6B-25-CR
    380…480V, 50/60 Hz
    3-Phase
    0.4 0.5 1.4 284A-FVD1P4Z-10-CR 284A-FVD1P4D-10-CR 284A-FVD1P4B-10-CR
    0.75 1 2.3 284A-FVD2P3Z-10-CR 284A-FVD2P3D-10-CR 284A-FVD2P3B-10-CR
    1.5 2 4 284A-FVD4P0Z-10-CR 284A-FVD4P0D-10-CR 284A-FVD4P0B-10-CR
    2.2 3 6 284A-FVD6P0Z-25-CR 284A-FVD6P0D-25-CR 284A-FVD6P0B-25-CR
    3 5 7.6 284A-FVD7P6Z-25-CR 284A-FVD7P6D-25-CR 284A-FVD7P6B-25-CR
    460…600V, 50/60 Hz
    3-Phase
    0.75 1 1.7 284A-FVE1P7Z-10-CR 284A-FVE1P7D-10-CR 284A-FVE1P7B-10-CR
    1.5 2 3 284A-FVE3P0Z-10-CR 284A-FVE3P0D-10-CR 284A-FVE3P0B-10-CR
    2.2 3 4.2 284A-FVE4P2Z-10-CR 284A-FVE4P2D-10-CR 284A-FVE4P2B-10-CR
    4 5 6.1 284A-FVE6P6Z-25-CR 284A-FVE6P6D-25-CR 284A-FVE6P6B-25-CR
      

    IP67/NEMA Type 4 with quick disconnects for ArmorConnect power media, Sensorless Vector Control, and Volts per Hertz torque performance, Up to 575V AC

    Input Voltage 3-Phase kW Rating 3-Phase Hp Rating Output Current [A] 24V DC
    Control Voltage
    120V AC
    Control Voltage
    240V AC
    Control Voltage
    Cat. No. Cat. No. Cat. No.
    200…240V, 50/60 Hz
    3-Phase
    0.4 0.5 2.3 284A-FVB2P3Z-10-RR 284A-FVB2P3D-10-RR 284A-FVB2P3B-10-RR
    0.75 1 5 284A-FVB5P0Z-10-RR 284A-FVB5P0D-10-RR 284A-FVB5P0B-10-RR
    1.5 2 7.6 284A-FVB7P6Z-25-RR 284A-FVB7P6D-25-RR 284A-FVB7P6B-25-RR
    380…480V, 50/60 Hz
    3-Phase
    0.4 0.5 1.4 284A-FVD1P4Z-10-RR 284A-FVD1P4D-10-RR 284A-FVD1P4B-10-RR
    0.75 1 2.3 284A-FVD2P3Z-10-RR 284A-FVD2P3D-10-RR 284A-FVD2P3B-10-RR
    1.5 2 4 284A-FVD4P0Z-10-RR 284A-FVD4P0D-10-RR 284A-FVD4P0B-10-RR
    2.2 3 6 284A-FVD6P0Z-25-RR 284A-FVD6P0D-25-RR 284A-FVD6P0B-25-RR
    3 5 7.6 284A-FVD7P6Z-25-RR 284A-FVD7P6D-25-RR 284A-FVD7P6B-25-RR
    460…600V, 50/60 Hz
    3-Phase
    0.75 1 1.7 284A-FVE1P7Z-10-RR 284A-FVE1P7D-10-RR 284A-FVE1P7B-10-RR
    1.5 2 3 284A-FVE3P0Z-10-RR 284A-FVE3P0D-10-RR 284A-FVE3P0B-10-RR
    2.2 3 4.2 284A-FVE4P2Z-10-RR 284A-FVE4P2D-10-RR 284A-FVE4P2B-10-RR
    4 5 6.1 284A-FVE6P6Z-25-RR 284A-FVE6P6D-25-RR 284A-FVE6P6B-25-RR
      

    Options — Factory Installed

    Description Cat. No. Modification
    Click to enlarge - ArmorStart_284panel_007564_bw Hand/Off/Auto Selector and Jog Keypad -3
      Safety Monitor (includes output contactor)‡ §  -SM
      EMI Filter -EMI
      Output Contactor -OC
      Shielded motor cable -CRN
      Supplied without motor cable -CRW
      Control Brake supplied with cable‡  -CB
      Control Brake supplied without cable‡  -CBW
      Source brake supplied with cable -SB
      Source brake supplied without cable -SBW
      0…10 Analog Input‡  -A10
      Dynamic Brake Connector (IP20 brake) -DB
      Dynamic Brake Connector (IP67 brake) -DB1
      ArmorConnect Power Media Connectivity, ArmorStart supplied with shielded motor cable -RRN
      ArmorConnect Power Media Connectivity, ArmorStart supplied without motor cable -RRW
      
    ‡ Not available with EtherNet/IP communications.
    § Not available with round media option (RR).

    Accessories

    DeviceNet Media ∆ 

    Description Length [m (ft)] Cat. No.
          Sealed
    Click to enlarge - 280_281-13-1 KwikLink pigtail drops are Insulation Displacement Connector (IDC) with integral Class 1 round cables for interfacing devices or power supplies to flat cable 1 (3.3) 1485P-P1E4-B1-N5
    2 (6.5) 1485P-P1E4-B2-N5
    3 (9.8) 1485P-P1E4-B3-N5
    6 (19.8) 1485P-P1E4-B6-N5
    Click to enlarge - 1485P-P1N5-MN5KF_4c DeviceNet Mini- T-Port Tap Left Keyway 1485P-P1N5-MN5KM
    Right Keyway 1485P-P1N5-MN5NF
    Description Connector Cat. No.
    Click to enlarge - 1485G-P#M5-R5_Product_Iso_4C Gray PVC Thin Cable Mini Straight Female
    Mini Straight Male
    1485G-P‡ N5-M5
    Mini Straight Female
    Mini Right Angle Male
    1485G-P‡ W5-N5
    Mini Right Angle Female
    Mini Straight Male
    1485G-P‡ M5-Z5
    Mini Right Angle Female
    Mini Straight Male
    1485G-P‡ W5-Z5
    Click to enlarge - 1485C-P#N5-M5_Product_Iso_4C Thick Cable Mini Straight Female
    Mini Straight Male
    1485C-P§ N5-M5
    Mini Straight Female
    Mini Right Angle Male
    1485C-P§ W5-N5
    Mini Right Angle Female
    Mini Straight Male
    1485C-P§ M5-Z5
    Mini Right Angle Female
    Mini Straight Male
    1485C-P§ W5-Z5
    Description Length m (ft) Cat. No.
    Click to enlarge - 193DNCT_10_4c DeviceNet Configuration Terminal
    Used to interface with objects on a DeviceNet network. Includes 1 m communications cable.
    1 (3.3) 193-DNCT
    Communication cable, color-coded bare leads 1 (3.3) 193-CB1
    Communication cable, microconnector (male) 1 (3.3) 193-CM1
    Panel Mount Adapter/Door Mount Bezel Kit 193-DNCT-BZ1
      
    ∆ See On-Machine Connectivity Catalog for complete cable selection information.
    ‡ Replace symbol with desired length in meters (Example: 1485G-P1N5-M5 for a 1 m cable). Standard cable lengths: 1, 2, 3, 4, 5, and 6 m.
    § Replace symbol with desired length in meters (Example: 1485C-P1N5-M5 for a 1 m cable). Standard cable lengths: 1, 2, 3, 4, 5, 6, 8, 10, 12, 18, 24, and 30 m.

    Industrial EtherNet Media∆ 

    Description Connector Type Unshielded
    Cat. No.
    M12, D-Code Patchcords and Cordsets
    Click to enlarge - 1585D-M4TBDM Straight male to straight male 1585D-M4TBDM-⋆ 
    Click to enlarge - 1585D-M4TBDE Straight male to right angle male 1585D-M4TBDE-⋆ 
    Click to enlarge - 1585D-E4TBDE Right angle male to right angle male 1585D-E4TBDE-⋆ 
    Click to enlarge - 1585D-M4TBDF Straight male to straight female 1585D-M4TBDF-⋆ 
    Front Mount Receptacle
    Click to enlarge - 1585D_D4TBJM1_Right_4C Front mount female to RJ45 1585D-D4TBJM-⋆ 
    Transition Cable
    Click to enlarge - 1585D-M4TBJM Straight male to RJ45 1585D-M4TBJM-⋆ 
      

    Description Conductors Jacket Material Cable Type Jacket Color Cat. No.
    RJ45 Patchcords
    Click to enlarge - 1585J-M4_Product_4C 4-pair Riser PVC Unshielded twisted pair Teal 1585J-M8PBJM-⋆ 
    High-flex TPE Teal 1585J-M8TBJM-⋆ 
    M12 to RJ45 Bulkhead Adapter
    Click to enlarge - 1585A-DD4JD_Product_Iso_4C
  • Transition from IP20 environment to IP67 environment

  • In-cabinet connectivity with RJ45 connector providing On-Machine solution with M12 D Code connector

  • Differential 100 W terminators used for unused pairs

  • Cat 5e
  • 1585A-DD4JD
      
    ⋆ Lengths available in 0.3, 0.6, 1, 2, 5, 10, 15, and additional increments of 5 m, up to 75 m.
    ∆ See On-Machine Connectivity Catalog for complete cable selection information.

    ArmorPoint® Media ♣ 

    Description Length [m (ft)] Cat. No.
    ArmorPoint Bus Extension Cable including Terminating Resistor 1 (3.3) 280A-EXT1
    Extension Cable to connect two ArmorStart Distributed Motor Controllers to ArmorPoint communication protocol 1 (3.3) 280A-EXTCABLE
      
    ♣  ArmorPoint media is only available with an IP67/NEMA Type 4 rating.

    Sensor Media ♠ 

    DeviceNet/ArmorPoint Communications
    Description ArmorStart I/O Connection Pin Count Connector Cat. No.
    Click to enlarge - 280_281-13-4 DC Micro Patchcord Input 4-pin Straight Female
    Straight Male
    889D-F4ACDM-♦ 
    Straight Female
    Right Angle Male
    889D-F4ACDE-♦ 
    Click to enlarge - 280_281-13-5 DC Micro V-Cable Input 4-pin Straight Female 879D-F4ACDM-♦ 
    Right Angle Female 879D-R4ACM-♦ 
    Click to enlarge - 280_281-13-6 AC Micro Patchcord Output 3-pin Straight Female
    Straight Male
    889R-F3AERM-♦ 
    Straight Female
    Right Angle Male
    889R-F3AERE-♦ 
      

    EtherNet/IP Communications
    Description ArmorStart I/O Connection Pin Count Connector Cat. No.
    Click to enlarge - 280_281-13-4 DC Micro Patchcord Input/Output 4-pin Straight Female
    Straight Male
    889D-F4ACDM-♦ 
    Straight Female
    Right Angle Male
    889D-F4ACDE-♦ 
    Click to enlarge - 280_281-13-5 DC Micro V-Cable Input 4-pin Straight Female 879D-F4ACDM-♦ 
    Right Angle Male 879D-R4ACM-♦ 
      
    ♠ See On-Machine Connectivity Catalog for complete cable selection information.
    ♦ Replace symbol with desired length in meters (Example: 889D-F4ACDM-1 for a 1 m cable). Standard cable lengths: 1, 2, 5, and 10 m.

    Motor and Brake Cables

    Click to enlarge - 280 cordset 90 degree  
    Description Cable Rating Length [m (ft)] Cat. No.
    Motor Cable Cordsets 90° M22 Motor Cordset IP67/NEMA Type 4 3 (9.8) 280-MTR22-M3
    6 (19.6) 280-MTR22-M6
    10 (32.8) 280-MTR22-M10
    14 (45.9) 280-MTR22-M14
    20 (65.6) 280-MTR22-M20
    90° M35 Motor Cordset IP67/NEMA Type 4 3 (9.8) 280-MTR35-M3
    6 (19.6) 280-MTR35-M6
    10 (32.8) 280-MTR35-M10
    14 (45.9) 280-MTR35-M14
    20 (65.6) 280-MTR35-M20
    90° M22 Motor Cordset IP69K/NEMA 4X 3 (9.8) 280S-MTR22-M3
    6 (19.6) 280S-MTR22-M6
    14 (45.9) 280S-MTR22-M14
    90° M35 Motor Cordset IP69K/NEMA 4X 6 (19.6) 280S-MTR35-M6
    14 (45.9) 280S-MTR35-M14
    Motor Cable Cordsets, High Flex⋆  90° M22 Motor Cordset IP67/NEMA Type 4 3 (9.8) 280-MTRF22-M3
    6 (19.6) 280-MTRF22-M6
    8 (26.2) 280-MTRF22-M8
    10 (32.8) 280-MTRF22-M10
    14 (45.9) 280-MTRF22-M14
    20 (65.6) 280-MTRF22-M20
    Motor Cable Cordsets,
    Shielded (VFD)
    90° M22 Motor Cordset IP67/NEMA Type 4 3 (9.8) 284-MTRS22-M3
    6 (19.6) 284-MTRS22-M6
    14 (45.9) 284-MTRS22-M14
    90° M22 Motor Cordset IP69K/NEMA Type 4X 3 (9.8) 284S-MTRS22-M3
    6 (19.6) 284S-MTRS22-M6
    14 (45.9) 284S-MTRS22-M14
    Extended Source/Control Brake Cable Cordsets 90° M25 Source Brake Cable IP67/NEMA Type 4 6 (19.6) 285-BRC25-M6
    14 (45.9) 285-BRC25-M14
    IP69K 6 (19.6) 285S-BRC25-M6
    14 (45.9) 285S-BRC25-M14
    Extended Source/Control Brake Cable Cordsets, High Flex⋆  90° M25 Source Brake Cable IP67/NEMA Type 4 3 (9.8) 285-BRCF25-M3
    6 (19.6) 285-BRCF25-M6
    10 (32.8) 285-BRCF25-M10
    14 (45.9) 285-BRCF25-M14
    20 (65.6) 285-BRCF25-M20
    Dynamic Brake Cables M22 Dynamic Brake Cable (DB Option) IP67/NEMA Type 4 3 (9.8) 285-DBK22-M3
    IP69K 3 (9.8) 285S-DBK22-M3
    Click to enlarge - 280_patchcord_90_degree  
    Description Description Cable Rating Length [m (ft)] Cat. No.
    Motor Cable Patchcords 90° Male/Straight Female M22 IP67/NEMA Type 4 1 (3.3) 280-MTR22-M1D
    3 (9.8) 280-MTR22-M3D
    90° Male/Straight Female M35 IP67/NEMA Type 4 1 (3.3) 280-MTR35-M1D
    3 (9.8) 280-MTR35-M3D
    90° Male/Straight Female M22 IP69K/NEMA Type 4X 1 (3.3) 280S-MTR22-M1D
    3 (9.8) 280S-MTR22-M3D
    90° Male/Straight Female M35 IP69K/NEMA Type 4X 1 (3.3) 280S-MTR35-M1D
    3 (9.8) 280S-MTR35-M3D
    Motor Cable Patchcords, Shielded (VFD) 90° Male/Straight Female M22 IP67/NEMA Type 4 1 (3.3) 284-MTRS22-M1D
    3 (9.8) 284-MTRS22-M3D
    90° Male/Straight Female M22 IP69K/NEMA Type 4X 1 (3.3) 284S-MTRS22-M1D
    3 (9.8) 284S-MTRS22-M3D
      
    ⋆ 14 million flex cycles, bend radius is maximum 8X the cable diameter (0.362 in. OD).

    Sealing Caps

    Click to enlarge - 1485A-C_Product2_GS Click to enlarge - 889A_sealcaps

      ArmorPoint DeviceNet EtherNet/IP
    Input Output Input Output Input Output
    Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No.
    Plastic Sealing Cap (M12)⋆  1485A-M12 1485A-M12 1485A-M12 1485A-M12 1485A-M12
    AC Micro Aluminum Sealing Cap⋆  889A-RMCAP 889A-RMCAP
    Stainless Steel Sealing Cap§  889AS-RMCAP 1485AS-C3 889AS-RMCAP
    Motor Connector Aluminum Sealing Cap (M22) for 10 A protection⋆  1485A-C1 1485A-C1 1485A-C1
    Motor Connector Aluminum Sealing Cap (M35) for 25 A protection⋆  889A-QMCAP 889A-QMCAP 889A-QMCAP
    Dynamic Brake Connector (M22) 1485A-C1 1485A-C1 1485A-C1
    Source/Control Brake Cap (M25) ∆  ∆  ∆ 
     
    ⋆ To achieve IP67 rating, sealing caps must be installed on all unused I/O connections.
    § To achieve IP69K/NEMA 4X rating, sealing caps must be installed on all unused I/O connections.
    ∆ Contact your local Rockwell Automation sales office or Allen-Bradley distributor.

    Handle and Cord Accessories

      Description Cat. No.
    Click to enlarge - 140M-C-M3_C Locking Tag
  • Padlock attachment to the lockable handles

  • Up to three padlocks 4…8 mm (5/16 in.) Æ shackle
  • 140M-C-M3
    Click to enlarge - 280-DISHDL Replacement At-Motor Disconnect Handle Kit
    includes: (1) handle, (1) guard, and (3) screws
    280-DISHDL
    Cord grips for ArmorStart devices with 10 A short circuit protection rating
    Click to enlarge - 2931NM_ArmorStartCordgrip 3/4 in. Strain relief cord connector and 3/4 in. lock nut
    Cable range: 0.31…0.56 in.
    Used with control power media cordset -
    Example cat. no.: 889N-M65GF-M2
    Thomas & Betts Cord Grip Cat. No. 2931NM
    1 in. Strain relief cord connector and 1 in. lock nut
    Cable range: 0.31…0.56 in.
    Used with control power media cordset -
    Example cat. no.: 280-PWR22G-M
    Thomas & Betts Cord Grip Cat. No. 2940NM
    Cord grips for ArmorStart devices with 25 A short circuit protection rating
    Click to enlarge - 2931NM_ArmorStartCordgrip 3/4 in. Strain relief cord connector and 3/4 in. lock nut
    Cable range: 0.31…0.56 in.
    Used with control power media cordset -
    Example cat. no.: 889N-M65GF-M2
    Thomas & Betts Cord Grip Cat. No. 2931NM
    1 in. Strain relief cord connector and 1 in. lock nut
    Cable range: 0.70…0.95 in.
    Used with three-phase power media cordset -
    Example cat. no.: 280-PWR35G-M1
    Thomas & Betts Cord Grip Cat. No. 2942NM
      

    ArmorStart Bulletin 284 Option DB (IP20) Resistor Installation Dimensions

    Dimensions are in millimeters (inches) and weights are in kilograms (pounds). Dimensions are not intended to be used for manufacturing purposes.

    Click to enlarge - dbresdim


    Frame Cat. No. Weight
    [kg (lb)]
    A AK-R2-091P500, AK-R2-047P500, AK-R2-360P500 1.1 (2.5)
    B AK-R2-030P1K2, AK-R2-120P1K2 2.7 (6)
      

    Recommended thermostat control wiring to prevent dynamic brake overheating

    Click to enlarge - 284_DB_thermostat


    Click to enlarge - 284_DB_thermostat_powerdiag


    Click to enlarge - 284_DB_thermostat_wirediag


    Peer-to-Peer Communications

    Click to enlarge - armorstart3_ZIP ZONE diagram


    (ZIP) Zone interlocking Parameters

    The Zone Control capabilities of ArmorStart Distributed Motor Controller is ideal for large horsepower (0.5…10 Hp) motored conveyors. The ArmorStart Distributed Motor Controllers have built-in DeviceNet Communications, DeviceLogix technology, and the added Zone Interlocking Parameters (ZIP), which allow one ArmorStart to consume data directly from up to four other DeviceNet nodes without going through the network scanner. These direct communications between conveyor zones are beneficial in a merge, diverter, and accumulation conveyor applications.


    ArmorStart to ArmorPoint Connectivity - (Networks other than DeviceNet)

    Click to enlarge - armorstart1


    When connecting to the Bulletin 1738 ArmorPoint Distributed I/O product, a network adapter and at least one ArmorPoint Digital Output, Digital Input, Analog, AC and Relay product, or Specialty product must be selected. The ArmorPoint Distributed I/O can accomodate up to 63 modules per network node. The cable that connects the ArmorPoint Distributed I/O product to the ArmorStart Distributed Motor Controller is the Cat. No. 280A-EXT1. The Cat. No. 280A-EXT1 includes an ArmorPoint bus extension cable and a network terminating resistor.

    Note:Access to DeviceLogix programming is available with RSNetworx for DeviceNet.


    Click to enlarge - armorstart2


    If an additional ArmorStart Distributed Motor Controller is to be connected, the Cat. No. 280A-EXTCABLE will be required. A maximum of two ArmorStart Distributed Motor Controllers can be connected to the Bulletin 1738 Distributed I/O.

    I/O Expansion with DeviceNet

    If the I/O capability of the Bulletin 280/281D ArmorStart Distributed Motor Controller needs to be expanded beyond the standard four inputs and two outputs, the ArmorStart Distributed Motor Controller with the DeviceNet communication protocol can be configured to the ADNX Architecture, in which the ArmorStart is part of the DeviceNet subnet, using the Cat. No. 1738-ADNX ArmorPoint Distributed I/O product.

    Click to enlarge - armorpoint_1738_explogic


    Bulletin 1738 ArmorPoint Distributed I/O Products

    Digital Output Products

    Description Cat. No.
    Click to enlarge - armorpoint_1738_dig_out 24V DC, eight source output with eight M12 connectors 1738-OB8EM12
    24V DC, eight source output with eight M8 connectors 1738-OB8EM8
    24V DC, four source output with four M12 connectors 1738-OB4EM12
    24V DC, four source output with four M8 connectors 1738-OB4EM8
    24V DC, two source output with two M12 connectors 1738-OB2EM12
    24V DC, two source output, 2 A prot. with two M12 connectors 1738-OB2EPM12
    24V DC, four sink output with four M12 connectors 1738-OV4EM12
      

    Digital Input Products

    Description Cat. No.
    Click to enlarge - armorpoint_1738_dig_in 24V DC, eight sink input with four M12 connectors, two points per connector 1738-IB8M12
    24V DC, eight sink input with eight M8 connectors 1738-IB8M8
    24V DC, eight sink input with one M23 connector 1738-IB8M23
    24V DC, four sink input with four M12 connectors 1738-IB4M12
    24V DC, four sink input with four M8 connectors 1738-IB4M8
    24V DC, two sink input with two M12 connectors 1738-IB2M12
    24V DC, four source input with four M12 connectors 1738-IV4M12
      

    Analog Products

    Description Cat. No.
    Click to enlarge - armorpoint_1738_anlg 24V DC analog current input with two M12 connectors 1738-IE2CM12
    24V DC analog voltage input with two M12 connectors 1738-IE2VM12
    24V DC analog current output with two M12 connectors 1738-OE2CM12
    24V DC analog voltage output with two M12 connectors 1738-OE2VM12
    24V DC, two thermocouple input 1738-IT2IM12
    24V DC, two RTD input 1738-IR2M12
      

    Power Supply Products

    Description Cat. No.
    Click to enlarge - armorpoint_1738_ps ArmorPoint I/O Field Potential Distributor Module 1738-FPD
    24V DC Expansion Power Supply 1738-EP24DC
      

    AC and Relay Products

    Description Cat. No.
    Click to enlarge - armorpoint_1738_ac_and_relay 24V DC Coil, N.O. DPST relay with two M12 connectors 1738-OW4M12
    24V DC Coil, N.O. DPST relay with two AC M12 connectors 1738-OW4M12AC
    120V AC, two input with two AC 4-pin M12 connectors 1738-IA2M12AC4
    120V AC, two input with two AC 3-pin M12 connectors 1738-IA2M12AC3
    120/230V AC, two output with two AC 3-pin M12 connectors 1738-OA2M12AC3
      

    Specialty Products

    Description Cat. No.
    Click to enlarge - armorpoint_1738_specialty ArmorPoint I/O RS-232 ASCII Serial Interface Module 1738-232ASCM12
    ArmorPoint I/O RS-485 ASCII Serial Interface Module 1738-485ASCM12
    24V DC Very High Speed Counter Module 1738-VHSC24M23
    ArmorPoint 5V Encoder/Counter Module 1738-IJM23
    ArmorPoint Synchronous Serial Interface Module with Absolute Encoder 1738-SSIM23
      

    Adapter Products

    Description Cat. No.
    Click to enlarge - armorpoint_1738_adapters ArmorPoint DeviceNet Adapter Module, Drop or Pass-through, with male and female M12 connectors 1738-ADN12
    ArmorPoint DeviceNet Adapter Module, Drop only, with male M18 connector 1738-ADN18
    ArmorPoint DeviceNet Adapter Module, Drop or Pass-through, with male and female M18 connectors 1738-ADN18P
    ArmorPoint DeviceNet 24V DC Adapter Module with subnet expansion 1738-ADNX
    ArmorPoint Redundant ControlNet Adapter Module 1738-ACNR
    ArmorPoint Ethernet/IP 10/100 Mbps Adapter Module 1738-AENT
    ArmorPoint I/O 2-Port EtherNet/IP Adapter (star, tree, linear, or ring topology)⋆  1738-AENTR
      
    ⋆ Requires a 24V DC expansion power unit (cat. no. 1738-EP24DC) when two ArmorStarts are connected to point bus.

    Specifications

    Connections

    Bulletin 284E ArmorStart with EtherNet/IP Communications

    Click to enlarge - 284E_front_callouts


    Bulletin 284D ArmorStart with DeviceNet Communications

    Click to enlarge - 284D_front_callouts


    Bulletin 284A ArmorStart for the ArmorPoint Bus Backplane

    Click to enlarge - 284A_front_callouts


    ⋆ Only available with SVC.


    ArmorStart Receptacle Pin Outs

    Receptacle Connections for 0…10V Analog Input (M22)

    Click to enlarge - 280_pinout_AnalogIn Pin 1: 10V DC
    Pin 2: 0…10V input
    Pin 3: Analog common
    Pin 4: Analog output
    Pin 5: NC (no connection)

    Receptacle Connections for ArmorPoint Interface (OUT)

    Click to enlarge - 280_pinout_ArmorPointOut Pin 1: CAN high
    Pin 2: Common
    Pin 3: +5V
    Pin 4: CAN low
    Pin 5: Enable out
    Pin 7: Common
    Pin 8: NC (no connection)

    Receptacle Connections for ArmorPoint Interface (IN)

    Click to enlarge - 280_pinout_ArmorPointIn Pin 1: CAN high
    Pin 2: Common
    Pin 3: +5V
    Pin 4: CAN low
    Pin 5: Enable out
    Pin 7: Common
    Pin 8: PE

    Receptacle Connections for DeviceNet Connector

    Click to enlarge - 280_pinout_DNet Pin 1: Drain (no connection)
    Pin 2: +VDNET
    Pin 3: -VDNET
    Pin 4: CAN_H
    Pin 5: CAN_L

    Receptacle Connections for EtherNet/IP (M12)

    Click to enlarge - 280_pinout_ENet Pin 1: Tx+
    Pin 2: Rx+
    Pin 3: Tx-
    Pin 4: Rx-

    Receptacle Connections for Input (M12)

    Click to enlarge - 280_pinout_AnalogIn Pin 1: +24V (A3 or DNET)
    Pin 2: Input 0
    Pin 3: Common
    Pin 4: Input 1
    Pin 5: NC (no connection)

    Receptacle Connections for Output, EtherNet/IP Version (M12)

    Click to enlarge - 280_pinout_AnalogIn Pin 1: NC (no connection)
    Pin 2: NC (no connection)
    Pin 3: Common
    Pin 4: Output +24V DC (A1)
    Pin 5: NC (no connection)

    Receptacle Connections for Output, DeviceNet or ArmorPoint Version (M12)

    Click to enlarge - 280_pinout_DNetOutput Pin 1: PE
    Pin 2: Return
    Pin 3: Relay out

    Receptacle Connections for Dynamic Brake (M22)

    Click to enlarge - 280_pinout_DynBrake Pin 1: GND (green/yellow)
    Pin 2: BR+ (black)
    Pin 3: BR- (white)

    Receptacle Connections for Incoming Control Power (M22)

    Click to enlarge - 280_pinout_ControlPowerIn Pin 1: Unswitched (A3)(red)
    Pin 2: Common (A2)(black)
    Pin 3: PE (green)
    Pin 4: Not used (blank)
    Pin 5: Switched (A1)(blue)
    Pin 6: Not used (white)

    Receptacle Connections for Source or Control Brake (M25)

    Click to enlarge - 280_pinout_SourceContactor Pin 1: L1 (black)
    Pin 2: GND (green/yellow)
    Pin 3: L2 (white)

    Receptacle Connections for Motor Connector (M22)

    Click to enlarge - 280_pinout_Motor2HP Pin 1: T1 (black)
    Pin 2: T2 (white)
    Pin 3: T3 (red)
    Pin 4: Ground (green/yellow)

    Receptacle Connections for Incoming 3-phase Power -
    10 A Short Circuit Protection (M22)


    Click to enlarge - 280_pinout_3phPowerInM22 Pin 1: L1 (black)
    Pin 2: L2 (white)
    Pin 3: L3 (red)
    Pin 4: Ground (green/yellow)

    Receptacle Connections for Incoming 3-phase Power -
    25 A Short Circuit Protection (M35)


    Click to enlarge - 280_pinout_3phPowerInM35 Pin 1: L1 (black)
    Pin 2: Ground (green/yellow)
    Pin 3: L3 (red)
    Pin 4: L2 (white)

    Electrical Ratings UL/NEMA IEC
    Power Circuit Rated Operation Voltage 200…575V 200…500V
    Rate Insulation Voltage 600V 600V
    Rated Impulsed Voltage 6 kV 6 kV
    Dielectric Withstand 2200V AC 2500V AC
    Operating Frequency 50/60 Hz 50/60 Hz
    Utilization Category N/A AC-3
    Protection Against Shock N/A IP2X
    Rated Maximum Operating Current 2.5 A
    5.5 A
    16 A
    Control Circuit Rated Operation Voltage 24V DC (+10%, -15%) A2 (should be grounded at voltage source)
    120V AC (+10%, -15%) A2 (should be grounded at voltage source)
    240V AC (+10%, -15%) A2 (should be grounded at voltage source)
    Rate Insulation Voltage 250V 250V
    Rated Impulsed Voltage 4 kV
    Dielectric Withstand 1500V AC 2000V AC
    Overvoltage Category III
    Operating Frequency 50/60 Hz 50/60 Hz
    Short Circuit Protection SCPD Performance Type 1 Current Rating Voltage 480Y/277V 480Y/480V 600Y/347V 600V
    10 A Sym. Amps RMS 65 kA 65 kA 30 kA 30 kA
    25 A 30 kA 30 kA 30 kA 30 kA
    SCPD List Size per NFPA 70 (NEC) or NFPA 79 for Group Motor Applications
      

      UL/NEMA IEC
    Environmental Operating Temperature Range -20…+40 °C (-4…+104 °F)
    Storage and Transportation
    Temperature Range
    –25….+85 °C (–13…+185 °F)
    Altitude 1000 m
    Humidity 5…95% (non-condensing)
    Pollution Degree 3
    Enclosure Ratings NEMA 4/12/13 IP67
    NEMA 4X IP69K
    Approximate Shipping Weight 13.6 kg (30 lb)
    Mechanical Resistance to Shock
    Operational 15 G
    Non-Operational 30 G
    Resistance to Vibration
    Operational 1 G, 0.15 mm (0.006 in.) displacement
    Non-Operational 2.5 G, 0.38 mm (0.015 in.) displacement
    Wire Size Primary/Secondary terminal:
    (16 …10 AWG)
    Primary/Secondary terminal:
    1.5…4.0 mm2
    Tightening Torque Primary terminal:
    10.8 lb•in
    Secondary terminal:
    4.5 lb•in
    Primary terminal:
    (1.2 N•m)
    Secondary terminal:
    (0.5 N•m)
    Wire Strip Length 0.35 in. (9 mm)
    Control and Safety Monitor Inputs
    Wire Size (18…10 AWG) 1.0…4.0 mm2
    Tightening Torque 6.2 lb•in 0.7 N•m
    Wire Strip Length 0.35 in. (9 mm)
    Disconnect Lock Out Maximum of 5/16 in. (8 mm) lock shackle or hasp. The hasp should not exceed 5/16 in. (8 mm) when closed, or damage will occur to disconnect guard.
    EMC Emission Levels Conducted Radio Frequency Emissions 10V rms Communication cables
    10V rms (PE)
    150 kHz…80 MHz
    Radiated Emissions Class A
    EMC Immunity Levels Electrostatic Discharge 4 kV contact and 8 kV Air
    Radio Frequency Electromagnetic Field 10V/m, 80 KHz…1 GHz
    3V/m, 1.4 GHz…2.0 GHz
    1V/m, 2.0 GHz…2.7 GHz
    Fast Transient 2 kV (Power)
    2 kV (PE)
    1 kV (Communications and control)
    Surge Transient 1 kV (12) L-L, 2 kV (2) L-N (earth)
    Standards Compliance   UL 508C; CSA C22.2, No. 14; EN50178; EN61800-3; EN/IEC 60947-4-2; CE Marked per Low Voltage 2006/95/EC; EMC Directive 2004/108/EC; CCC; ODVA for EtherNet/IP; ODVA for DeviceNet
    Certifications   cULus (File No. E207834, Guide NMMS, NMMS7)
      

    ArmorPoint and DeviceNet Versions — Control and I/O Power Requirements
      Units No Options Brake or Output Contactor With Brake and Output Contactor
    Control Voltage Volts 24V DC 120V AC 240V AC 24V DC 120V AC 240V AC 24V DC 120V AC 240V AC
    Total Control VA
    (Pick Up)
    VA (W) (11 W) 16 24 (13 W) 38 46 (16 W) 60 68
    Total Control VA
    (Hold In)
    VA (W) (11 W) 16 24 (13 W) 20 28 (16 W) 24 32
    External Devices powered by Control Voltage
    Outputs (2)
    (1 A max. each)
    Amps 2 2 2 2 2 2 2 2 2
    Total Control VA (Pick Up) with max. outputs VA (W) (59 W) 256 504 (61 W) 278 548 (64 W) 300 548
    Total Control VA (Hold In) with max. outputs VA (W) (59 W) 256 504 (61 W) 261 512 (64 W) 264 512
      

      UL/NEMA IEC
    Input Ratings Rated Operation Voltage 24V DC
    Input On-State Voltage Range 10…26V DC
    Input On-State Current 3.0 mA @ 10V DC
    7.2 mA @ 24V DC
    Input Off-State Voltage Range 0…5V DC
    Input Off-State Current <1.5 mA
    Input Filter — Software Selectable
    Off to On Settable from 0…64 ms in 1 ms increments
    On to Off Settable from 0…64 ms in 1 ms increments
    Input Compatibility N/A IEC 1+
    Number of Inputs 4
    Sensor Source
    Voltage Status Only 11…25V DC from DeviceNet
    Current Available 50 mA max. per input, 200 mA total
    Output Ratings
    Sourced from control circuit - A1/A2
    Rated Operation Voltage 240V AC/30V DC 240V AC/30V DC
    Rate Insulation Voltage 250V 250V
    Dielectric Withstand 1500V AC 2000V AC
    Operating Frequency 50/60 Hz
    Type of Control Circuit Electromechanical relay
    Type of Current AC/DC
    Conventional Thermal Current Ith Total of both outputs £ 2 A
    Type of Contacts Normally open (N.O.)
    Number of Contacts 2
    DeviceNet Specifications DeviceNet Supply Voltage Rating Range 11…25V DC, 24V DC nominal
    DeviceNet Input Current 167 mA @ 24V DC - 4.0 W
    DeviceNet Input Current 364 mA @ 11V DC - 4.0 W
    External Devices powered by DeviceNet Sensors inputs 4 x 50 mA - total 200 mA
    Total w/max Sensor Inputs (4) 367 mA @ 24V DC - 8.8 W
    DeviceNet Input Current Surge 15 A for 250 ms
    DeviceNet Communications Baud Rates 125, 250, 500 kbps
    Distance Maximum 500 m (1630 ft) @ 125 kbps
    Distance Maximum 200 m (656 ft) @ 250 kbps
    Distance Maximum 100 m (328 ft) @ 500 kbps
    ArmorPoint Ratings Backplane Current Load 400 mA
     

    EtherNet/IP Version - Control and I/O Power Requirements
    Control Voltage Units A1/A2⋆  A3/A2‡  A3/A2§ 
    Volts 24V DC
    Current Amps 0.375 0.125 0.35
    Total Control Power (no options) Watts 9 3 8.4
    Total Control Power (with Dynamic Brake or Output Contactor option) Watts 12 3 8.4
    Total Control Power (with Dynamic Brake and Output Contactor option) Watts 15 3 8.4
      
    ⋆ Add power requirements for outputs (1 A max.) to A1/A2.
    ‡ Add power requirements for intputs (200 mA max.) to A3/A2.
    § If A1 power is disconnected.

      UL/NEMA IEC
    Input Ratings
    Sourced from control circuit - A3/A2
    Rated Operation Voltage 24V DC
    Input On-State Voltage Range 10…26V DC
    Input On-State Current 3.0 mA @ 10V DC
    7.2 mA @ 24V DC
    Input Off-State Voltage Range 0…5V DC
    Input Off-State Current <1.5 mA
    Input Filter — Software Selectable
    Off to On Settable from 0…64 ms in 1 ms increments
    On to Off Settable from 0…64 ms in 1 ms increments
    Input Compatibility N/A IEC 1+
    Number of Inputs 4
    Sensor Source
    Voltage Status Only 11…26.4V DC from DeviceNet
    Current Available 50 mA max. per input, 200 mA total
    Output Ratings
    Sourced from control circuit - A1/A2
    Rated Operation Voltage 26.4V DC
    Rate Insulation Voltage 250V
    Dielectric Withstand 1500V AC (UL) 2000V AC (IEC)
    Type of Control Circuit Solid state sourcing output
    Type of Current 24V DC
    Conventional Thermal Current Ith 0.5 A each, 1 A max. combined
    Type of Contacts Normally open (N.O.)
    Number of Contacts 2
    Load Types Resistive or light inductive
    Surge Suppression Integrated diode, clamps @ 35V DC
    Thermo-Protection Integrated short circuit and over current protection
    Maximum Cycle Rate 30 operations/minute capacitive and inductive loads
    Maximum Blocking Voltage 35V DC
    Maximum On-State Voltage @ Maximum Output 1.5V DC
    Maximum Off-State Leakage Current 10 mA
    Device Level Ring (DLR)   Beacon-based performance including IEEE 1588 end to end transparent clock
    Maximum Nodes 50
    Fault Recovery Ring recovery time is less than 3 ms for a 50 node network
    EtherNet Port   2 D-coded, 4-pin female M12 connecters
    Ports Embedded switch with 2 ports
    IP Address DHCP enabled by default
    DHCP Timeout 30 seconds
    Communication Rate 10/100 Mbs with auto negotiate half duplex and full duplex
    Data
  • Transported over both TCP and UDP

  • Min. of 500 I/O packets/second (pps)

  • Supports up to 150 concurrent TCP sockets
  • Web Server   Embedded web server
    Security Login and password configurable
    E-mail Support Simple Mail Transfer Protocol (SMTP)
    Configuration Status, diagnostics, and configuration tabs
    Device Connections Supports scheduled (Class 1) and unscheduled (Class 3 & UCMM) connections
    6 - Class 3 connections are supported simultaneously
    Minimum of 1 - Class 1 or maximum of 2 - Class 1, CIP connections (1 exclusive owner, 1 input only and 1 listen only) are supported
    Class 1 Connection API: 2…3200 ms
    Class 3 Connection API: 100…10 000 ms
    20 ms Request Packet Interval (RPI) default
    3 concurrent Encapsulation sessions
    TCP port supports 5 concurrent incoming connections
     

    Drive Characteristics Sensorless Vector Performance Sensorless Vector Control
    Maximum Hp (kW)/
    Input Voltage
    2 Hp (1.5 kW)/230V AC
    5 Hp (3.3 kW)/480V AC
    2 Hp (1.5 kW)/230V AC
    5 Hp (3.3 kW)/480V AC, 5 Hp (4.0 kW)/600V AC
    Overload Capacity 150% for 60 seconds, 200% for 3 seconds 150% for 60 seconds, 200% for 3 seconds
    Output Frequency (programmable) 0…400 Hz 0…400 Hz
    Efficiency (typical) 97.5% 97.5%
    Preset Speeds 4 8
    Carrier Frequency 2…16 kHz 2…16 kHz
    Skip Frequency ü
    Process Control Loop ü (PID)
    StepLogic Functionality ü
    Timer/Counter Functions ü
      

    Drive Ratings — VFD Output Current vs. Input Current
    Line Voltage Frequency [Hz] 3-Phase kW Rating 3-Phase Hp Rating Output Current [A] Input Current [A]
    Sensorless Vector Control Sensorless Vector Performance Sensorless Vector Control Sensorless Vector Performance
    200 50 0.4 2.3 3.65
    0.75 4.5 6.40
    1.5 7.6 10.65
    230 60 0.5 2.3 2.3 3.10 2.5
    1 4.5 4.5 5.70 5.2
    2 7.6 7.6 9.45 9.5
    380 50 0.4 1.4 2.15
    0.75 2.3 3.80
    1.5 4.0 6.40
    2.2 6.0 9.00
    3.0 7.6 12.40
    460 60 0.5 1.4 1.4 1.85 1.8
    1 2.3 2.3 3.45 3.2
    2 4.0 4.0 5.57 5.7
    3 6.0 6.0 8.20 7.5
    5 7.6 7.6 12.5 8.6
    575 60 1 1.7 2.78
    2 3.0 4.73
    3 4.2 6.64
    5 6.6 10.75
      

    Protective Specifications — Sensorless Vector Performance
    Motor Protection I2t overload protection — 150% for 60 seconds, 200% for 3 seconds (provides Class 10 protection)
    Overcurrent 200% hardware limit, 300% instantaneous fault
    Over Voltage 200…240V AC Input — Trip occurs @ 405V DC bus voltage (equivalent to 290V AC incoming line)
    380…460V AC Input — Trip occurs @ 810V DC bus voltage (equivalent to 575V AC incoming line)
    Under Voltage 200…240V AC Input — Trip occurs @ 210V DC bus voltage (equivalent to 150V AC incoming line)
    380…480V AC Input — Trip occurs @ 390V DC bus voltage (equivalent to 275V AC incoming line)
    Faultless Power Ride Through 100 milliseconds
      

    Control Specifications — Sensorless Vector Performance
    Carrier Frequency 2…16 kHz drive rating based on 4 kHz
    Frequency Accuracy — Digital Input within ±0.05% of set output frequency
    Speed Regulation (open loop with slip compensation) ±2% of base speed across a 40:1 speed range
    Stop Modes Multiple programmable stop modes including: Ramp, Coast, DC-Brake, Ramp-to-Hold, and S Curve
    Acceleration/Deceleration Two independently programmable acceleration and deceleration times: each time may be programmed from 0…600 seconds in 0.1 second increments
    Intermittent Overload 150% overload capability for up to 1 minute, 200% overload capability for up to 3 seconds
    Electronic Motor Overload Protection Class 10 protection with speed sensitive response and power-down overload retention function
      

    Sensorless Vector Performance (SVP) Minimum DB Resistance
    Input Voltage Drive Rating [kW] Drive Rating [Hp] Minimum DB Resistance [W]
    200…240V, 50/60 Hz,
    Three-Phase
    0.2 0.25 60
    0.4 0.5 60
    0.75 1 60
    1.5 2 60
    480V, 50/60 Hz,
    Three-Phase
    0.4 0.5 121
    0.75 1 121
    1.5 2 121
    2.2 3 97
    3.7 5 97
      

    Protective Specifications — Sensorless Vector Control
    Motor Protection I2t overload protection — 150% for 60 seconds, 200% for 3 seconds (provides Class 10 protection)
    Overcurrent 200% hardware limit, 300% instantaneous fault
    Over Voltage 200…240V AC Input – Trip occurs @ 405V DC bus voltage (equivalent to 290V AC incoming line)
    380…460V AC Input – Trip occurs @ 810V DC bus voltage (equivalent to 575V AC incoming line)
    460…600V AC Input – Trip occurs @ 1005V DC bus voltage (equivalent to 711V AC incoming line)
    Under Voltage 200…240V AC Input – Trip occurs @ 210V DC bus voltage (equivalent to 150V AC incoming line)
    380…480V AC Input – Trip occurs @ 390V DC bus voltage (equivalent to 275V AC incoming line)
    460…600V AC Input – If 600V rated trip occurs @ 487V DC bus voltage (344V AC incoming line);
    If 480V rated trip occurs @ 390V DC bus voltage (275V AC incoming line)
    Faultless Power Ride Through 100 milliseconds
      

    Control Specifications — Sensorless Vector Control
    Carrier Frequency 2…16 kHz drive rating based on 4 kHz
    Frequency Accuracy — Digital Input within ±0.05% of set output frequency
    Speed Regulation (open loop with slip compensation) ±1% of base speed across a 60:1 speed range
    Stop Modes Multiple programmable stop modes including: Ramp, Coast, DC-Brake, Ramp-to-Hold, and S Curve
    Acceleration/Deceleration Two independently programmable acceleration and deceleration times: each time may be programmed from 0…600 seconds in 0.1 second increments
    Intermittent Overload 150% overload capability for up to 1 minute, 200% overload capability for up to 3 seconds
    Electronic Motor Overload Protection Class 10 protection with speed sensitive response
      

    Sensorless Vector Control (SVC) Minimum DB Resistance
    Drive Rating Minimum DB Resistance
    Input Voltage [kW] [Hp] [W]
    240V, 50/60 Hz,
    Three-Phase
    0.4 0.5 48
    0.75 1 48
    1.5 2 48
    480V, 50/60 Hz,
    Three-Phase
    0.4 0.5 97
    0.75 1 97
    1.5 2 97
    2.2 3 97
    4.0 5 77
    600V, 50/60 Hz,
    Three-Phase
    0.75 1 120
    1.5 2 120
    2.2 3 82
    4.0 5 82
      

    Motor Overload Trip Curves

    Motor overload current parameter provides class 10 overload protection. Ambient insensitivity is inherent in the electronic design of the overload.

    Click to enlarge - mtrovrld

    Approximate Dimensions

    Dimensions for IP67/NEMA Type 4 with Conduit Entrance

    Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. All dimensions are subject to change.

    Click to enlarge - 284E_dims_typ4_conduit_1-3hp


    Dimensions for NEMA Type 4X with Conduit Entrance

    Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. All dimensions are subject to change.

    Click to enlarge - 284D_dims_typ4X_conduit_1-3hp


    Dimensions for IP67/NEMA Type 4 with ArmorConnect Connectivity

    Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. All dimensions are subject to change.

    Click to enlarge - 284E_dims_typ4_armorconnect_1-3hp


    Dimensions for NEMA Type 4X with ArmorConnect Connectivity (1 Hp or less @ 230V AC and 2 Hp or less @ 480…575V AC)

    Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. All dimensions are subject to change.

    Click to enlarge - 280 series c 4x 2hp sht2 lft


    Dimensions for NEMA Type 4X with ArmorConnect Connectivity (2 Hp or greater @ 230V AC and 3 Hp or greater @ 480…575V AC)

    Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. All dimensions are subject to change.

    Click to enlarge - 284_dims_typ4X_armorconnect_2-3hp