Catalogs > Industrial Controls Catalog > Motor Control, Solid-State > Distributed Starters (Networked) > Bulletin 284 ArmorStart Distributed Motor Controller
Bulletin 284 ArmorStart Distributed Motor Controller
| Introduction | Standards Compliance and Certifications | Description | Factory Installed Options | Cat. No. Explanation | Product Selection |
| Cat. No. Explanation | Product Selection | Options Factory Installed | Specifications | Approximate Dimensions |
| 284 | D | | F | V | D2P3 | D | | 10 | | CR | | Option 1 | | Option 2 | | Option 3 |
| a | b | c | d | e | f | g | h | i | j | k |
| a | |
| Bulletin Number | |
| Code | Description |
| 284 | UFD Starter |
| b | |
| Communications | |
| Code | Description |
| D | DeviceNet™ |
| A | ArmorPoint |
| c | |
| Enclosure Type | |
| Code | Description |
| F | Type 4 (IP67) |
| S | Type 4X |
| d | |
| Torque Performance Mode | |
| Code | Description |
| V | Sensorless Vector Control and Volts per Hertz |
| e | |||||
| Output Current | |||||
| 200…240V | 380…480V | 500…600V | |||
| Code | Description | Code | Description | Code | Description |
| B2P3 | 2.3 A, 0.4 kW, 0.5 Hp | D1P4 | 1.4 A, 0.4 kW, 0.5 Hp | E1P7 | 1.7 A, 0.75 kW, 1.0 Hp |
| B5P0 | 5.0 A, 0.75 kW, 1.0 Hp | D2P3 | 2.3 A, 0.75 kW, 1.0 Hp | E3P0 | 3.0 A, 1.5 kW, 2.0 Hp |
| B7P6 | 7.6 A, 1.5 kW, 2.0 Hp | D4P0 | 4.0 A, 1.5 kW, 2.0 Hp | E4P2 | 4.2 A, 2.2 kW, 3.0 Hp |
| — | — | D6P0 | 6.0 A, 2.2 kW, 3.0 Hp | E6P6 | 6.6 A, 4.0 kW, 5.0 Hp |
| — | — | D7P6 | 7.6 A, 3.3 kW, 5.0 Hp | — | — |
| f | |
| Control Voltage | |
| Code | Description |
| Z | 24V DC |
| D | 120V AC |
| B | 240V AC |
| g | |
| Short Circuit Protection (Motor Circuit Protector) | |
| Code | Description |
| 10 | 10 A Rated Device |
| 25 | 25 A Rated Device |
| h | ||||
| Control and 3-Phase Power Connections / Motor Cable Connection (CR: Conduit/Round Media) or (RR: Round/Round Media) |
||||
Code |
Description | |||
| Control Power | 3-Phase Power | Motor Cable | ||
| CR | blank | Conduit Entrance | Conduit Entrance | 3 m, unshielded cordset male 90° |
| CR | N | Conduit Entrance | Conduit Entrance | 3 m, shielded cordset male 90° |
| CR | W ¬ | Conduit Entrance | Conduit Entrance | No cable |
| RR | blank | Round Media (Male Receptacle) | Round Media (Male Receptacle) | 3 m, unshielded cordset male 90° |
| RR | N | Round Media (Male Receptacle) | Round Media (Male Receptacle) | 3 m, shielded cordset male 90° |
| RR | W ¬ | Round Media (Male Receptacle) | Round Media (Male Receptacle) | No cable |
| i | |
| Option 1 | |
| Code | Description |
| 3 | Hand/Off/Auto Selector Keypad with Jog Function |
| j | ||
| Option 2 | ||
| Code | Description | |
| CB | blank | Control Brake Contactor |
| CB | W ¬ | No cable |
| DB | blank | DB Brake Connector |
| SB | blank | Source Brake Contactor |
| SB | W ¬ | No cable |
| k | |
| Option 3 | |
| Code | Description |
| EMI | EMI Filter |
| OC | Output Contactor |
¬ See Accessories on Cables for extended motor and brake cable lengths.
T The output contactor is included with the Safety Monitor option.