| Description
|
N.O.
|
N.C.
|
Connection Diagram
|
Cat. No.
|
|
Auxiliary Contact Blocks for side mounting with sequence terminal designations 1- and 2-pole Quick and easy mounting without tools One block per device only
|
1
|
0
|
|
|
|
|
150-CA10
|
| 2
|
0
|
150-CA20
|
| 0
|
1
|
150-CA01
|
| 1
|
1
|
150-CA11 (Form C)
|
|
|
| Description
|
For Use With
|
Pkg. Qty.
|
Cat. No.
|
|
Connecting modules to 140-M Electrical interconnection between SMC-Delta/SMC-3 and 140-M. Motor protector and SMC must be mounted separately.
|
Connects 140-M-C to 150-C3…25
|
1
|
150-CC25
|
Connects 140-M-D to 150-C3…25
|
1
|
150-CD25
|
Connects 140-M-F to 150-C3…37
|
1
|
150-CF45
|
|
Connecting modules to 100-C Electrical interconnection between SMC-Delta/SMC-3 and 100-C. Contactor and SMC must be mounted separately.
|
Connects 100-C09…23 to 150-C3…19
|
1
|
150-CI23
|
Connects 100-C30…37 to 150-C3…37
|
1
|
150-CI37
|
|
|
| Description
|
For Use With
|
Pkg. Qty.
|
Cat. No.
|
|
480V Protective Module
|
150-C3…37NB
|
1
|
150-C84
|
| 150-C43…85NB (line and/or load)
|
1
|
150-C84P
|
| 150-C108…480NB (line and/or load)
|
1
|
150-F84L
|
| 600V Protective Module
|
150-C3…37NC
|
1
|
150-C86
|
| 150-C43…85NC (line and/or load)
|
1
|
150-C86P
|
| 150-C108…480NC (line and/or load)
|
1
|
150-F86L
|
|
|
| Description
|
For Use With
|
Pkg. Qty.
|
Cat. No.
|
|
Terminal Cover IEC line or load terminal covers for 108…480 A devices. Dead front protection
|
150-C108…-C135
|
1
|
150-TC1
|
| 150-C201…-C251
|
1
|
150-TC2
|
| 150-C317…-C480
|
1
|
150-TC3
|
|
|
|
Current Rating (A) T
|
Wire Size
|
Total No. of Line Controller Terminal Lugs Possible Each Side
|
Pkg. Qty.
|
Cat. No.
|
| Line Side
|
Load Side
|
| 108…135§
|
#6…250 MCM AWG 16 mm2…120 mm2
|
3
|
3
|
3
|
199-LF1
|
| 201…251§
|
6
|
6
|
| 317…480§
|
#4…500 MCM AWG 25 mm2…240 mm2
|
6
|
6
|
199-LG1
|
|
|
| Line and Load terminals are provided as standard on enclosed SMCs.
|
| T 1…85 A units have box lugs standard. No additional lugs are required.
|
| § When a multi-conductor lug is required, refer to the Instruction Sheet for appropriate lug catalog number.
|
| Description
|
For Use With
|
Pkg. Qty.
|
Cat. No.
|
|
Marking Tag Sheet 160 perforated paper labels each, 6 x 17 mm, to be used with a transparent cover
|
150-C, 150-D
|
10
|
100-FMP
|
Transparent Cover To be used with marking tag sheets
|
150-C, 150-D
|
100
|
100-FMC
|
|
|
| Description
|
For Use With
|
Pkg. Qty.
|
Cat. No.
|
|
Remote Reset Solenoid for remote reset of electronic overload
|
193-T all, 150-C
|
1
|
193-ER1Ä
|
|
|
| Voltage
|
24
|
48
|
110
|
115
|
120
|
220
|
240
|
| 50 Hz
|
J
|
—
|
D
|
—
|
—
|
A
|
—
|
| 60 Hz
|
J
|
—
|
—
|
—
|
D
|
—
|
A
|
| DC
|
Z24
|
Z48
|
—
|
Z01
|
—
|
—
|
—
|
|
|
| Surcharge for special voltages up to 20 pcs. (no surcharge for quantities greater than 20 pcs.)
|