Catalogs > Industrial Controls Catalog > Motor Control, Solid-State > Soft Starters > SMC™-3 Smart Motor Controllers
SMC™-3 Smart Motor Controllers
| Introduction | Standards Compliance and Certifications | Modes of Operation | Description of Features | Cat. No. Explanation | Product Selection |
| Typical Wiring Diagrams | Specifications | Approximate Dimensions | Enclosed Options | Accessories |
Open Type and Non-Combination Enclosed (IP65, NEMA 4/12) Controllers — For use with Line-Connected Motors
| Build a Catalog Number |
| Build a Catalog Number |
| Rated Voltage [V AC] |
Motor Current (A)T | Max. kW, 50Hz | Max. Hp, 60 Hz | Control Power | Open Type — Line-Connected Motors | IP65 (Type 4/12) Enclosed Non-Combination Controllers§ |
| Cat. No. | Cat. No. | |||||
| 200/208 | 1…3 | — | 0.5 | 100…240V AC, 50/60 Hz | 150-C3NBD | 150-C3FHD |
| — | 24V AC/DC | 150-C3NBR | — | |||
| 3…9 | — | 0.75…2 | 100…240V AC, 50/60 Hz | 150-C9NBD | 150-C9FHD | |
| — | 24V AC/DC | 150-C9NBR | — | |||
| 5.3…16 | — | 1.5…3 | 100…240V AC, 50/60 Hz | 150-C16NBD | 150-C16FHD | |
| — | 24V AC/DC | 150-C16NBR | — | |||
| 6.3…19 | — | 1.5…3 | 100…240V AC, 50/60 Hz | 150-C19NBD | 150-C25FHD | |
| — | 24V AC/DC | 150-C19NBR | — | |||
| 9.2…25 | — | 3…7.5 | 100…240V AC, 50/60 Hz | 150-C25NBD | 150-C25FHD | |
| — | 24V AC/DC | 150-C25NBR | — | |||
| 10…30 | — | 3…7.5 | 100…240V AC, 50/60 Hz | 150-C30NBD | 150-C30FHD | |
| — | 24V AC/DC | 150-C30NBR | — | |||
| 12.3…37 | — | 5…10 | 100…240V AC, 50/60 Hz | 150-C37NBD | 150-C37FHD | |
| — | 24V AC/DC | 150-C37NBR | — | |||
| 14.3…43 | — | 5…10 | 100…240V AC, 50/60 Hz | 150-C43NBD | 150-C43FHD | |
| — | 24V AC/DC | 150-C43NBR | — | |||
| 20…60 | — | 7.5…15 | 100…240V AC, 50/60 Hz | 150-C60NBD | 150-C60FHD | |
| — | 24V AC/DC | 150-C60NBR | — | |||
| 28.3…85 | — | 10…25 | 100…240V AC, 50/60 Hz | 150-C85NBD | 150-C85FHD | |
| — | 24V AC/DC | 150-C85NBR | — | |||
| 27…108 | — | 20…30 | 100…240V AC, 50/60 Hz | 150-C108NBD | 150-C108FHD | |
| — | 24V AC/DC§ | 150-C108NBR | — | |||
| 34…135 | — | 25…40 | 100…240V AC, 50/60 Hz | 150-C135NBD | 150-C135FHD | |
| — | 24V AC/DC§ | 150-C135NBR | — | |||
| 67…201 | — | 40…60 | 100…240V AC, 50/60 Hz | 150-C201NBD | 150-C201FHD | |
| — | 24V AC/DC§ | 150-C201NBR | — | |||
| 84…251 | — | 50…75 | 100…240V AC, 50/60 Hz | 150-C251NBD | 150-C251FHD | |
| — | 24V AC/DC§ | 150-C251NBR | — | |||
| 106…317 | — | 60…100 | 100…240V AC, 50/60 Hz | 150-C317NBD | 150-C317FHD | |
| — | 24V AC/DC§ | 150-C317NBR | — | |||
| 120…361 | — | 75…125 | 100…240V AC, 50/60 Hz | 150-C361NBD | 150-C361FHD | |
| — | 24V AC/DC§ | 150-C361NBR | — | |||
| 160…480 | — | 100…150 | 100…240V AC, 50/60 Hz | 150-C480NBD | 150-C480FHD | |
| — | 24V AC/DC§ | 150-C480NBR | — | |||
| T Motor FLA rating should fall within specified current range for unit to operate properly. | ||||||
| § These controllers require a separate 100…240V, 50/60 Hz single-phase control source. To add a control circuit transformer to the enclosure, add the appropriate option code to the catalog string. | ||||||
| § Separate 120V or 240V single phase is required for fan operation. | ||||||
| Rated Voltage [V AC] |
Motor Current (A)T | Max. kW, 50 Hz | Max. Hp, 60 Hz | Control Power | Open Type — Line-Connected Motors | IP65 (Type 4/12) Enclosed Non-Combination Controllers§ |
| Cat. No. | Cat. No. | |||||
| 230 | 1…3 | 0.55 | 0.5 | 100…240V AC, 50/60 Hz | 150-C3NBD | 150-C3FAD |
| 24V AC/DC | 150-C3NBR | — | ||||
| 3…9 | 2.2 | 0.75…2 | 100…240V AC, 50/60 Hz | 150-C9NBD | 150-C9FAD | |
| 24V AC/DC | 150-C9NBR | — | ||||
| 5.3…16 | 4 | 1.5…5 | 100…240V AC, 50/60 Hz | 150-C16NBD | 150-C16FAD | |
| 24V AC/DC | 150-C16NBR | — | ||||
| 6.3…19 | 4 | 2…5 | 100…240V AC, 50/60 Hz | 150-C19NBD | 150-C25FAD | |
| 24V AC/DC | 150-C19NBR | — | ||||
| 9.2…25 | 5.5 | 3…7.5 | 100…240V AC, 50/60 Hz | 150-C25NBD | 150-C25FAD | |
| 24V AC/DC | 150-C25NBR | — | ||||
| 10…30 | 7.5 | 5…10 | 100…240V AC, 50/60 Hz | 150-C30NBD | 150-C30FAD | |
| 24V AC/DC | 150-C30NBR | — | ||||
| 12.3…37 | 7.5 | 5…10 | 100…240V AC, 50/60 Hz | 150-C37NBD | 150-C37FAD | |
| 24V AC/DC | 150-C37NBR | — | ||||
| 14.3…43 | 11 | 5…15 | 100…240V AC, 50/60 Hz | 150-C43NBD | 150-C43FAD | |
| 24V AC/DC | 150-C43NBR | — | ||||
| 20…60 | 15 | 7.5…20 | 100…240V AC, 50/60 Hz | 150-C60NBD | 150-C60FAD | |
| 24V AC/DC | 150-C60NBR | — | ||||
| 28.3…85 | 22 | 15…30 | 100…240V AC, 50/60 Hz | 150-C85NBD | 150-C85FAD | |
| 24V AC/DC | 150-C85NBR | — | ||||
| 27…108 | 30 | 20…40 | 100…240V AC, 50/60 Hz | 150-C108NBD | 150-C108FAD | |
| 24V AC/DC§ | 150-C108NBR | — | ||||
| 34…135 | 37 | 25…50 | 100…240V AC, 50/60 Hz | 150-C135NBD | 150-C135FAD | |
| 24V AC/DC§ | 150-C135NBR | — | ||||
| 67…201 | 55 | 40…75 | 100…240V AC, 50/60 Hz | 150-C201NBD | 150-C201FAD | |
| 24V AC/DC§ | 150-C201NBR | — | ||||
| 84…251 | 75 | 50…100 | 100…240V AC, 50/60 Hz | 150-C251NBD | 150-C251FAD | |
| 24V AC/DC§ | 150-C251NBR | — | ||||
| 106…317 | 90 | 60…125 | 100…240V AC, 50/60 Hz | 150-C317NBD | 150-C317FAD | |
| 24V AC/DC§ | 150-C317NBR | — | ||||
| 120…361 | 110 | 75…150 | 100…240V AC, 50/60 Hz | 150-C361NBD | 150-C361FAD | |
| 24V AC/DC§ | 150-C361NBR | — | ||||
| 160…480 | 132 | 100…200 | 100…240V AC, 50/60 Hz | 150-C480NBD | 150-C480FAD | |
| 24V AC/DC§ | 150-C480NBR | — | ||||
| T Motor FLA rating should fall within specified current range for unit to operate properly. | ||||||
| § These controllers require a separate 100…240V, 50/60 Hz single-phase control source. To add a control circuit transformer to the enclosure, add the appropriate option code to the catalog string. | ||||||
| § Separate 120V or 240V single phase is required for fan operation. | ||||||
| Rated Voltage [V AC] |
Motor Current (A)T | Max. kW, 50 Hz | Max. Hp, 60 Hz | Control Power | Open Type — Line-Connected Motors | IP65 (Type 4/12) Enclosed Non-Combination Controllers§ |
| Cat. No. | Cat. No. | |||||
| 380/400/ 415/460 |
1…3 | 1.1 | 0.5…1.5 | 100…240V AC, 50/60 Hz | 150-C3NBD | 150-C3FBD |
| 24V AC/DC | 150-C3NBR | — | ||||
| 3…9 | 4 | 1.5…5 | 100…240V AC, 50/60 Hz | 150-C9NBD | 150-C9FBD | |
| 24V AC/DC | 150-C9NBR | — | ||||
| 5.3…16 | 7.5 | 5…10 | 100…240V AC, 50/60 Hz | 150-C16NBD | 150-C16FBD | |
| 24V AC/DC | 150-C16NBR | — | ||||
| 6.3…19 | 7.5 | 5…10 | 100…240V AC, 50/60 Hz | 150-C19NBD | 150-C19NBR | |
| 24V AC/DC | 150-C19NBR | — | ||||
| 9.2…25 | 11 | 7.5…15 | 100…240V AC, 50/60 Hz | 150-C25NBD | 150-C25NBR | |
| 24V AC/DC | 150-C25NBR | — | ||||
| 10…30 | 15 | 7.5…20 | 100…240V AC, 50/60 Hz | 150-C30NBD | 150-C30FBD | |
| 24V AC/DC | 150-C30NBR | — | ||||
| 12.3…37 | 18.5 | 10…25 | 100…240V AC, 50/60 Hz | 150-C37NBD | 150-C37FBD | |
| 24V AC/DC | 150-C37NBR | — | ||||
| 14.3…43 | 22 | 10…30 | 100…240V AC, 50/60 Hz | 150-C43NBD | 150-C43FBD | |
| 24V AC/DC | 150-C43NBR | — | ||||
| 20…60 | 30 | 15…40 | 100…240V AC, 50/60 Hz | 150-C60NBD | 150-C60FBD | |
| 24V AC/DC | 150-C60NBR | — | ||||
| 28.3…85 | 45 | 25…60 | 100…240V AC, 50/60 Hz | 150-C85NBD | 150-C85FBD | |
| 24V AC/DC | 150-C85NBR | — | ||||
| 27…108 | 55 | 50…75 | 100…240V AC, 50/60 Hz | 150-C108NBD | 150-C108FBD | |
| 24V AC/DC§ | 150-C108NBR | — | ||||
| 34…135 | 75 | 60…100 | 100…240V AC, 50/60 Hz | 150-C135NBD | 150-C135FBD | |
| 24V AC/DC§ | 150-C135NBR | — | ||||
| 67…201 | 95…110 | 75…150 | 100…240V AC, 50/60 Hz | 150-C201NBD | 150-C201FBD | |
| 24V AC/DC§ | 150-C201NBR | — | ||||
| 84…251 | 95…132 | 100…200 | 100…240V AC, 50/60 Hz | 150-C251NBD | 150-C251FBD | |
| 24V AC/DC§ | 150-C251NBR | — | ||||
| 106…317 | 95…160 | 125…250 | 100…240V AC, 50/60 Hz | 150-C317NBD | 150-C317FBD | |
| 24V AC/DC§ | 150-C317NBR | — | ||||
| 120…361 | 110…200 | 250…300 | 100…240V AC, 50/60 Hz | 150-C361NBD | 150-C361FBD | |
| 24V AC/DC§ | 150-C361NBR | — | ||||
| 160…480 | 160…250 | 300…400 | 100…240V AC, 50/60 Hz | 150-C480NBD | 150-C480FBD | |
| 24V AC/DC§ | 150-C480NBR | — | ||||
| T Motor FLA rating should fall within specified current range for unit to operate properly. | ||||||
| § These controllers require a separate 100…240V, 50/60 Hz single-phase control source. To add a control circuit transformer to the enclosure, add the appropriate option code to the catalog string. | ||||||
| § Separate 120V or 240V single phase is required for fan operation. | ||||||
| Rated Voltage [V AC] |
Motor Current (A)T | Max. kW, 50 Hz | Max. Hp, 60 Hz | Control Power | Open Type — Line-Connected Motors | IP65 (Type 4/12) Enclosed Non-Combination Controllers§ |
| Cat. No. | Cat. No. | |||||
| 500/575 | 1…3 | 1.5 | 0.75…2 | 100…240V AC, 50/60 Hz | 150-C3NCD | 150-C3FCD |
| 24V AC/DC | 150-C3NCR | — | ||||
| 3…9 | 5.5 | 3…7.5 | 100…240V AC, 50/60 Hz | 150-C9NCD | 150-C9FCD | |
| 24V AC/DC | 150-C9NCR | — | ||||
| 5.3…16 | 7.5 | 5…10 | 100…240V AC, 50/60 Hz | 150-C16NCD | 150-C16FCD | |
| 24V AC/DC | 150-C16NCR | — | ||||
| 6.3…19 | 11 | 7.5…15 | 100…240V AC, 50/60 Hz | 150-C19NCD | 150-C25FCD | |
| 24V AC/DC | 150-C19NCR | — | ||||
| 9.2…25 | 15 | 7.5…20 | 100…240V AC, 50/60 Hz | 150-C25NCD | 150-C25FCD | |
| 24V AC/DC | 150-C25NCR | — | ||||
| 10…30 | 18.5 | 10…25 | 100…240V AC, 50/60 Hz | 150-C30NCD | 150-C30FCD | |
| 24V AC/DC | 150-C30NCR | — | ||||
| 12.3…37 | 22 | 15…30 | 100…240V AC, 50/60 Hz | 150-C37NCD | 150-C37FCD | |
| 24V AC/DC | 150-C37NCR | — | ||||
| 14.3…43 | 22 | 15…40 | 100…240V AC, 50/60 Hz | 150-C43NCD | 150-C43FCD | |
| 24V AC/DC | 150-C43NCR | — | ||||
| 20…60 | 37 | 20…50 | 100…240V AC, 50/60 Hz | 150-C60NCD | 150-C60FCD | |
| 24V AC/DC | 150-C60NCR | — | ||||
| 28.3…85 | 55 | 30…75 | 100…240V AC, 50/60 Hz | 150-C85NCD | 150-C85FCD | |
| 24V AC/DC | 150-C85NCR | — | ||||
| 27…108 | 75 | 60…100 | 100…240V AC, 50/60 Hz | 150-C108NCD | 150-C108FCD | |
| 24V AC/DC§ | 150-C108NCR | — | ||||
| 34…135 | 90 | 75…125 | 100…240V AC, 50/60 Hz | 150-C135NCD | 150-C135FCD | |
| 24V AC/DC§ | 150-C135NCR | — | ||||
| 67…201 | 75…132 | 100…200 | 100…240V AC, 50/60 Hz | 150-C201NCD | 150-C201FCD | |
| 24V AC/DC§ | 150-C201NCR | — | ||||
| 84…251 | 90…160 | 125…250 | 100…240V AC, 50/60 Hz | 150-C251NCD | 150-C251FCD | |
| 24V AC/DC§ | 150-C251NCR | — | ||||
| 106…317 | 100…200 | 200…300 | 100…240V AC, 50/60 Hz | 150-C317NCD | 150-C317FCD | |
| 24V AC/DC§ | 150-C317NCR | — | ||||
| 120…361 | 132…250 | 200…350 | 100…240V AC, 50/60 Hz | 150-C361NCD | 150-C361FCD | |
| 24V AC/DC§ | 150-C361NCR | — | ||||
| 160…480 | 200…315 | 250…500 | 100…240V AC, 50/60 Hz | 150-C480NCD | 150-C480FCD | |
| 24V AC/DC§ | 150-C480NCR | — | ||||
| T Motor FLA rating should fall within specified current range for unit to operate properly. | ||||||
| § These controllers require a separate 100…240V, 50/60 Hz single-phase control source. To add a control circuit transformer to the enclosure, add the appropriate option code to the catalog string. | ||||||
| § Separate 120V or 240V single phase is required for fan operation. | ||||||
Open Type Controllers — For use with Delta-Connected Motors
| Rated Voltage [V AC] |
Motor Current (A)T | Max. kW, 50Hz | Max. Hp, 60 Hz | Control Power | Open Type |
| Cat. No. | |||||
| 200/208 | 1.7…5.1 | — | 1 | 100…240V AC, 50/60 Hz | 150-C3NBD |
| — | 24V AC/DC | 150-C3NBR | |||
| 5.1…16 | — | 1.5…3 | 100…240V AC, 50/60 Hz | 150-C9NBD | |
| — | 24V AC/DC | 150-C9NBR | |||
| 9.1…27.6 | — | 3…7.5 | 100…240V AC, 50/60 Hz | 150-C16NBD | |
| — | 24V AC/DC | 150-C16NBR | |||
| 10.9…32.8 | — | 3…10 | 100…240V AC, 50/60 Hz | 150-C19NBD | |
| — | 24V AC/DC | 150-C19NBR | |||
| 14.3…43 | — | 3…10 | 100…240V AC, 50/60 Hz | 150-C25NBD | |
| — | 24V AC/DC | 150-C25NBR | |||
| 17.3…52 | — | 5…10 | 100…240V AC, 50/60 Hz | 150-C30NBD | |
| — | 24V AC/DC | 150-C30NBR | |||
| 21…64 | — | 7.5…20 | 100…240V AC, 50/60 Hz | 150-C37NBD | |
| — | 24V AC/DC | 150-C37NBR | |||
| 25…74 | — | 7.5…20 | 100…240V AC, 50/60 Hz | 150-C43NBD | |
| — | 24V AC/DC | 150-C43NBR | |||
| 34.6…104 | — | 15…30 | 100…240V AC, 50/60 Hz | 150-C60NBD | |
| — | 24V AC/DC | 150-C60NBR | |||
| 50…147 | — | 15…40 | 100…240V AC, 50/60 Hz | 150-C85NBD | |
| — | 24V AC/DC | 150-C85NBR | |||
| 47…187 | — | 20…60 | 100…240V AC, 50/60 Hz | 150-C108NBD | |
| — | 24V AC/DC§ | 150-C108NBR | |||
| 59…234 | — | 20…75 | 100…240V AC, 50/60 Hz | 150-C135NBD | |
| — | 24V AC/DC§ | 150-C135NBR | |||
| 116…348 | — | 75…100 | 100…240V AC, 50/60 Hz | 150-C201NBD | |
| — | 24V AC/DC§ | 150-C201NBR | |||
| 145…435 | — | 100…150 | 100…240V AC, 50/60 Hz | 150-C251NBD | |
| — | 24V AC/DC§ | 150-C251NBR | |||
| 183…549 | — | 100…200 | 100…240V AC, 50/60 Hz | 150-C317NBD | |
| — | 24V AC/DC§ | 150-C317NBR | |||
| 208…625 | — | 125…200 | 100…240V AC, 50/60 Hz | 150-C361NBD | |
| — | 24V AC/DC§ | 150-C361NBR | |||
| 277…831 | — | 200…300 | 100…240V AC, 50/60 Hz | 150-C480NBD | |
| — | 24V AC/DC§ | 150-C480NBR | |||
| T Motor FLA rating should fall within specified current range for unit to operate properly. | |||||
| § Separate 120V or 240V single phase is required for fan operation. | |||||
| Rated Voltage [V AC] |
Motor Current (A)T | Max. kW, 50 Hz | Max. Hp, 60 Hz | Control Power | Open Type |
| Cat. No. | |||||
| 230 | 1.7…5.1 | 0.25…1.1 | 1 | 100…240V AC, 50/60 Hz | 150-C3NBD |
| 24V AC/DC | 150-C3NBR | ||||
| 5.1…16 | 1.1…4 | 1…5 | 100…240V AC, 50/60 Hz | 150-C9NBD | |
| 24V AC/DC | 150-C9NBR | ||||
| 9.1…27.6 | 2.2…7.5 | 3…7.5 | 100…240V AC, 50/60 Hz | 150-C16NBD | |
| 24V AC/DC | 150-C16NBR | ||||
| 10.9…32.8 | 2.2…7.5 | 3…10 | 100…240V AC, 50/60 Hz | 150-C19NBD | |
| 24V AC/DC | 150-C19NBR | ||||
| 14.3…43 | 4…11 | 3…15 | 100…240V AC, 50/60 Hz | 150-C25NBD | |
| 24V AC/DC | 150-C25NBR | ||||
| 17.3…52 | 4…15 | 5…15 | 100…240V AC, 50/60 Hz | 150-C30NBD | |
| 24V AC/DC | 150-C30NBR | ||||
| 21…64 | 5.5…18.5 | 7.5…20 | 100…240V AC, 50/60 Hz | 150-C37NBD | |
| 24V AC/DC | 150-C37NBR | ||||
| 25…74 | 5.5…22 | 7.5…25 | 100…240V AC, 50/60 Hz | 150-C43NBD | |
| 24V AC/DC | 150-C43NBR | ||||
| 34.6…104 | 7.5…30 | 15…40 | 100…240V AC, 50/60 Hz | 150-C60NBD | |
| 24V AC/DC | 150-C60NBR | ||||
| 50…147 | 15…45 | 20…50 | 100…240V AC, 50/60 Hz | 150-C85NBD | |
| 24V AC/DC | 150-C85NBR | ||||
| 47…187 | 55 | 20…60 | 100…240V AC, 50/60 Hz | 150-C108NBD | |
| 24V AC/DC§ | 150-C108NBR | ||||
| 59…234 | 75 | 25…75 | 100…240V AC, 50/60 Hz | 150-C135NBD | |
| 24V AC/DC§ | 150-C135NBR | ||||
| 116…348 | 110 | 75…125 | 100…240V AC, 50/60 Hz | 150-C201NBD | |
| 24V AC/DC§ | 150-C201NBR | ||||
| 145…435 | 132 | 100…150 | 100…240V AC, 50/60 Hz | 150-C251NBD | |
| 24V AC/DC§ | 150-C251NBR | ||||
| 183…549 | 160 | 125…200 | 100…240V AC, 50/60 Hz | 150-C317NBD | |
| 24V AC/DC§ | 150-C317NBR | ||||
| 208…625 | 200 | 150…250 | 100…240V AC, 50/60 Hz | 150-C361NBD | |
| 24V AC/DC§ | 150-C361NBR | ||||
| 277…831 | 250 | 200…300 | 100…240V AC, 50/60 Hz | 150-C480NBD | |
| 24V AC/DC§ | 150-C480NBR | ||||
| T Motor FLA rating should fall within specified current range for unit to operate properly. | |||||
| § Separate 120V or 240V single phase is required for fan operation. | |||||
| Rated Voltage [V AC] |
Motor Current (A)T | Max. kW, 50 Hz | Max. Hp, 60 Hz | Control Power | Open Type |
| Cat. No. | |||||
| 380/400/415/460 | 1.7…5.1 | 0.55…2.2 | 0.5…2 | 100…240V AC, 50/60 Hz | 150-C3NBD |
| 24V AC/DC | 150-C3NBR | ||||
| 5.1…16 | 2.2…7.5 | 2…7.5 | 100…240V AC, 50/60 Hz | 150-C9NBD | |
| 24V AC/DC | 150-C9NBR | ||||
| 9.1…27.6 | 4…11 | 5…15 | 100…240V AC, 50/60 Hz | 150-C16NBD | |
| 24V AC/DC | 150-C16NBR | ||||
| 10.9…32.8 | 4…15 | 5…15 | 100…240V AC, 50/60 Hz | 150-C19NBD | |
| 24V AC/DC | 150-C19NBR | ||||
| 14.3…43 | 5.5…22 | 7.5…20 | 100…240V AC, 50/60 Hz | 150-C25NBD | |
| 24V AC/DC | 150-C25NBR | ||||
| 17.3…52 | 7.5…22 | 7.5…30 | 100…240V AC, 50/60 Hz | 150-C30NBD | |
| 24V AC/DC | 150-C30NBR | ||||
| 21…64 | 7.5…30 | 10…40 | 100…240V AC, 50/60 Hz | 150-C37NBD | |
| 24V AC/DC | 150-C37NBR | ||||
| 25…74 | 11…37 | 10…50 | 100…240V AC, 50/60 Hz | 150-C43NBD | |
| 24V AC/DC | 150-C43NBR | ||||
| 34.6…104 | 15…55 | 20…75 | 100…240V AC, 50/60 Hz | 150-C60NBD | |
| 24V AC/DC | 150-C60NBR | ||||
| 50…147 | 22…75 | 25…100 | 100…240V AC, 50/60 Hz | 150-C85NBD | |
| 24V AC/DC | 150-C85NBR | ||||
| 47…187 | 90 | 40…150 | 100…240V AC, 50/60 Hz | 150-C108NBD | |
| 24V AC/DC§ | 150-C108NBR | ||||
| 59…234 | 132 | 50…150 | 100…240V AC, 50/60 Hz | 150-C135NBD | |
| 24V AC/DC§ | 150-C135NBR | ||||
| 116…348 | 160 | 150…250 | 100…240V AC, 50/60 Hz | 150-C201NBD | |
| 24V AC/DC§ | 150-C201NBR | ||||
| 145…435 | 250 | 200…350 | 100…240V AC, 50/60 Hz | 150-C251NBD | |
| 24V AC/DC§ | 150-C251NBR | ||||
| 183…549 | 315 | 250…450 | 100…240V AC, 50/60 Hz | 150-C317NBD | |
| 24V AC/DC§ | 150-C317NBR | ||||
| 208…625 | 355 | 300…500 | 100…240V AC, 50/60 Hz | 150-C361NBD | |
| 24V AC/DC§ | 150-C361NBR | ||||
| 277…831 | 450 | 350…700 | 100…240V AC, 50/60 Hz | 150-C480NBD | |
| 24V AC/DC§ | 150-C480NBR | ||||
| T Motor FLA rating should fall within specified current range for unit to operate properly. | |||||
| § Separate 120V or 240V single phase is required for fan operation. | |||||
| Rated Voltage [V AC] |
Motor Current (A)T | Max. kW, 50 Hz | Max. Hp, 60 Hz | Control Power | Open Type |
| Cat. No. | |||||
| 500/575 | 1.7…5.1 | 0.75…3 | 1…3 | 100…240V AC, 50/60 Hz | 150-C3NCD |
| 24V AC/DC | 150-C3NCR | ||||
| 5.1…16 | 3…7.5 | 3…10 | 100…240V AC, 50/60 Hz | 150-C9NCD | |
| 24V AC/DC | 150-C9NCR | ||||
| 9.1…27.6 | 5.5…15 | 7.5…20 | 100…240V AC, 50/60 Hz | 150-C16NCD | |
| 24V AC/DC | 150-C16NCR | ||||
| 10.9…32.8 | 5.5…22 | 7.5…30 | 100…240V AC, 50/60 Hz | 150-C19NCD | |
| 24V AC/DC | 150-C19NCR | ||||
| 14.3…43 | 7.5…22 | 10…40 | 100…240V AC, 50/60 Hz | 150-C25NCD | |
| 24V AC/DC | 150-C25NCR | ||||
| 17.3…52 | 11…30 | 15…50 | 100…240V AC, 50/60 Hz | 150-C30NCD | |
| 24V AC/DC | 150-C30NCR | ||||
| 21…64 | 11…37 | 15…60 | 100…240V AC, 50/60 Hz | 150-C37NCD | |
| 24V AC/DC | 150-C37NCR | ||||
| 25…74 | 15…45 | 20…60 | 100…240V AC, 50/60 Hz | 150-C43NCD | |
| 24V AC/DC | 150-C43NCR | ||||
| 34.6…104 | 22…55 | 30…100 | 100…240V AC, 50/60 Hz | 150-C60NCD | |
| 24V AC/DC | 150-C60NCR | ||||
| 50…147 | 30…90 | 40…150 | 100…240V AC, 50/60 Hz | 150-C85NCD | |
| 24V AC/DC | 150-C85NCR | ||||
| 47…187 | 132 | 50…150 | 100…240V AC, 50/60 Hz | 150-C108NCD | |
| 24V AC/DC§ | 150-C108NCR | ||||
| 59…234 | 160 | 60…200 | 100…240V AC, 50/60 Hz | 150-C135NCD | |
| 24V AC/DC§ | 150-C135NCR | ||||
| 116…348 | 250 | 250…300 | 100…240V AC, 50/60 Hz | 150-C201NCD | |
| 24V AC/DC§ | 150-C201NCR | ||||
| 145…435 | 315 | 250…400 | 100…240V AC, 50/60 Hz | 150-C251NCD | |
| 24V AC/DC§ | 150-C251NCR | ||||
| 183…549 | 400 | 300…500 | 100…240V AC, 50/60 Hz | 150-C317NCD | |
| 24V AC/DC§ | 150-C317NCR | ||||
| 208…625 | 450 | 350…600 | 100…240V AC, 50/60 Hz | 150-C361NCD | |
| 24V AC/DC§ | 150-C361NCR | ||||
| 277…831 | 560 | 400…900 | 100…240V AC, 50/60 Hz | 150-C480NCD | |
| 24V AC/DC§ | 150-C480NCR | ||||
| T Motor FLA rating should fall within specified current range for unit to operate properly. | |||||
| § Separate 120V or 240V single phase is required for fan operation. | |||||
Combination Enclosed (IP65, NEMA 4/12) Controllers with Fusible Disconnect or Circuit Breaker
| Build a Catalog Number |
| Rated Voltage [V AC] |
Current Rating (A) |
kW | Hp | IP65 (Type 4/12) Enclosed Combination Controllers with Fusible Disconnect T | IP65 (Type 4/12) Enclosed Combination Controllers with Circuit Breaker T |
| Cat. No. | Cat. No. | ||||
| 200/208 | 3 | — | 0.5 | 152H-C3FHD-33 | 153H-C3FHD-33 |
| 9 | — | 0.75 | 152H-C9FHD-34 | 153H-C9FHD-34 | |
| 9 | — | 1 | 152H-C9FHD-35 | 153H-C9FHD-35 | |
| 9 | — | 1.5 | 152H-C9FHD-36 | 153H-C9FHD-36 | |
| 16 | — | 2 | 152H-C16FHD-37 | 153H-C16FHD-37 | |
| 16 | — | 3 | 152H-C16FHD-38 | 153H-C16FHD-38 | |
| 25 | — | 5 | 152H-C25FHD-39 | 153H-C25FHD-39 | |
| 37 | — | 7.5 | 152H-C37FHD-40 | 153H-C37FHD-40 | |
| 43 | — | 10 | 152H-C43FHD-41 | 153H-C43FHD-41 | |
| 60 | — | 15 | 152H-C60FHD-42 | 153H-C60FHD-42 | |
| 85 | — | 20 | 152H-C85FHD-43 | 153H-C85FHD-43 | |
| 85 | — | 25 | 152H-C85FHD-44 | 153H-C85FHD-44 | |
| 108 | — | 30 | 152H-C108FHD-45 | 153H-C108FHD-45 | |
| 135 | — | 40 | 152H-C135FHD-46 | 153H-C135FHD-46 | |
| 201 | — | 60 | 152H-C201FHD-48 | 153H-C201FHD-48 | |
| 251 | — | 75 | 152H-C251FHD-49 | 153H-C251FHD-49 | |
| 317 | — | 100 | 152H-C317FHD-50 | 153H-C317FHD-50 | |
| 361 | — | 125 | 152H-C361FHD-51 | 153H-C361FHD-51 | |
| 480 | — | 150 | 152H-C480FHD-52 | 153H-C480FHD-52 | |
| 230 | 3 | 0.37 | 0.5 | 152H-C3FAD-33 | 153H-C3FAD-33 |
| 9 | 0.55 | 0.75 | 152H-C9FAD-34 | 153H-C9FAD-34 | |
| 9 | 0.75 | 1 | 152H-C9FAD-35 | 153H-C9FAD-35 | |
| 9 | 1.1 | 1.5 | 152H-C9FAD-36 | 153H-C9FAD-36 | |
| 9 | 1.5 | 2 | 152H-C9FAD-37 | 153H-C9FAD-37 | |
| 16 | 2.2 | 3 | 152H-C16FAD-38 | 153H-C16FAD-38 | |
| 25 | 3.7 | 5 | 152H-C25FAD-39 | 153H-C25FAD-39 | |
| 30 | 5.5 | 7.5 | 152H-C30FAD-40 | 153H-C30FAD-40 | |
| 37 | 7.5 | 10 | 152H-C37FAD-41 | 153H-C37FAD-41 | |
| 43 | 11 | 15 | 152H-C43FAD-42 | 153H-C43FAD-42 | |
| 60 | 15 | 20 | 152H-C60FAD-43 | 153H-C60FAD-43 | |
| 85 | 18.5 | 25 | 152H-C85FAD-44 | 153H-C85FAD-44 | |
| 85 | 22 | 30 | 152H-C85FAD-45 | 153H-C85FAD-45 | |
| 108 | 30 | 40 | 152H-C108FAD-46 | 153H-C108FAD-46 | |
| 135 | 37 | 50 | 152H-C135FAD-47 | 153H-C135FAD-47 | |
| 201 | 55 | 75 | 152H-C201FAD-49 | 153H-C201FAD-49 | |
| 251 | 75 | 100 | 152H-C251FAD-50 | 153H-C251FAD-50 | |
| 317 | 90 | 125 | 152H-C317FAD-51 | 153H-C317FAD-51 | |
| 361 | 110 | 150 | 152H-C361FAD-52 | 153H-C361FAD-52 | |
| 480 | 147 | 200 | 152H-C480FAD-54 | 153H-C480FAD-54 | |
| T These controllers require a separate 100…240V, 50/60 Hz single-phase control source. To add a control circuit transformer to the enclosure, add the appropriate option code to the catalog string. | |||||
| Rated Voltage [V AC] |
Current Rating (A) |
kW | Hp | IP65 (Type 4/12) Enclosed Combination Controllers with Fusible Disconnect T | IP65 (Type 4/12) Enclosed Combination Controllers with Circuit Breaker T |
| Cat. No. | Cat. No. | ||||
| 460 | 3 | 0.37 | 0.5 | 152H-C3FBD-33 | 153H-C3FBD-33 |
| 3 | 0.55 | 0.75 | 152H-C3FBD-34 | 153H-C3FBD-34 | |
| 3 | 0.75 | 1 | 152H-C3FBD-35 | 153H-C3FBD-35 | |
| 9 | 1.1 | 1.5 | 152H-C9FBD-36 | 153H-C9FBD-36 | |
| 9 | 1.5 | 2 | 152H-C9FBD-37 | 153H-C9FBD-37 | |
| 9 | 2.2 | 3 | 152H-C9FBD-38 | 153H-C9FBD-38 | |
| 16 | 3.7 | 5 | 152H-C16FBD-39 | 153H-C16FBD-39 | |
| 16 | 5.5 | 7.5 | 152H-C16FBD-40 | 153H-C16FBD-40 | |
| 25 | 7.5 | 10 | 152H-C25FBD-41 | 153H-C25FBD-41 | |
| 30 | 11 | 15 | 152H-C30FBD-42 | 153H-C30FBD-42 | |
| 37 | 15 | 20 | 152H-C37FBD-43 | 153H-C37FBD-43 | |
| 43 | 18.5 | 25 | 152H-C43FBD-44 | 153H-C43FBD-44 | |
| 43 | 22 | 30 | 152H-C43FBD-45 | 153H-C43FBD-45 | |
| 60 | 30 | 40 | 152H-C60FBD-46 | 153H-C60FBD-46 | |
| 85 | 37 | 50 | 152H-C85FBD-47 | 153H-C85FBD-47 | |
| 85 | 45 | 60 | 152H-C85FBD-48 | 153H-C85FBD-48 | |
| 108 | 55 | 75 | 152H-C108FBD-49 | 153H-C108FBD-49 | |
| 135 | 75 | 100 | 152H-C135FBD-50 | 153H-C135FBD-50 | |
| 201 | 110 | 150 | 152H-C201FBD-52 | 153H-C201FBD-52 | |
| 251 | 132 | 200 | 152H-C251FBD-54 | 153H-C251FBD-54 | |
| 317 | 160 | 250 | 152H-C317FBD-56 | 153H-C317FBD-56 | |
| 361 | 200 | 300 | 152H-C361FBD-57 | 153H-C361FBD-57 | |
| 480 | 250 | 400 | 152H-C480FBD-59 | 153H-C480FBD-59 | |
| 500/575 | 3 | 0.55 | 0.75 | 152H-C3FCD-34 | 153H-C3FCD-34 |
| 3 | 0.75 | 1 | 152H-C3FCD-35 | 153H-C3FCD-35 | |
| 9 | 1.1 | 1.5 | 152H-C9FCD-36 | 153H-C9FCD-36 | |
| 9 | 1.5 | 2 | 152H-C9FCD-37 | 153H-C9FCD-37 | |
| 9 | 2.2 | 3 | 152H-C9FCD-38 | 153H-C9FCD-38 | |
| 9 | 3.7 | 5 | 152H-C9FCD-39 | 153H-C9FCD-39 | |
| 16 | 5.5 | 7.5 | 152H-C16FCD-40 | 153H-C16FCD-40 | |
| 16 | 7.5 | 10 | 152H-C16FCD-41 | 153H-C16FCD-41 | |
| 25 | 11 | 15 | 152H-C25FCD-42 | 153H-C25FCD-42 | |
| 30 | 15 | 20 | 152H-C30FCD-43 | 153H-C30FCD-43 | |
| 37 | 18.5 | 25 | 152H-C37FCD-44 | 153H-C37FCD-44 | |
| 43 | 22 | 30 | 152H-C43FCD-45 | 153H-C43FCD-45 | |
| 43 | 30 | 40 | 152H-C43FCD-46 | 153H-C43FCD-46 | |
| 60 | 37 | 50 | 152H-C60FCD-47 | 153H-C60FCD-47 | |
| 85 | 45 | 60 | 152H-C85FCD-48 | 153H-C85FCD-48 | |
| 85 | 55 | 75 | 152H-C85FCD-49 | 153H-C85FCD-49 | |
| 108 | 75 | 100 | 152H-C108FCD-50 | 153H-C108FCD-50 | |
| 135 | 90 | 125 | 152H-C135FCD-51 | 153H-C135FCD-51 | |
| 201 | 132 | 200 | 152H-C201FCD-54 | 153H-C201FCD-54 | |
| 251 | 160 | 250 | 152H-C251FCD-56 | 153H-C251FCD-56 | |
| 317 | 200 | 300 | 152H-C317FCD-57 | 153H-C317FCD-57 | |
| 361 | 250 | 350 | 152H-C361FCD-58 | 153H-C361FCD-58 | |
| 480 | 315 | 500 | 152H-C480FCD-61 | 153H-C480FCD-61 | |