Soft Starters

Catalogs > Industrial Controls Catalog > Motor Control, Solid-State > Soft Starters > SMC™ Flex Smart Motor Controllers

SMC™ Flex Smart Motor Controllers

Introduction Standards Compliance and Certifications Modes of Operation Introduction Cat. No. Explanation
Product Selection Control Options (open and enclosed) Accessories Specifications Approximate Dimensions and Shipping Weights
Cat. No. Explanation

Open and Non-Combination

150 F135    F    B    D    B 8L
a    b    c    d    e    f    g

a
Bulletin Number
Code Description
150 Solid-State Controller

b
Controller Ratings
Code Description
F5 5 A, 3 Hp @ 460V AC
F25 25 A, 15 Hp @ 460V AC
F43 43 A, 30 Hp @ 460V AC
F60 60 A, 40 Hp @ 460V AC
F85 85 A, 60 Hp @ 460V AC
F108 108 A, 75 Hp @ 460V AC
F135 135 A, 100 Hp @ 460V AC
F201 201 A, 150 Hp @ 460V AC
F251 251 A, 200 Hp @ 460V AC
F317 317 A, 250 Hp @ 460V AC
F361 361 A, 300 Hp @ 460V AC
F480 480 A, 400 Hp @ 460V AC
F625 625 A, 500 Hp @ 460V AC
F780 780 A, 600 Hp @ 460V AC
F970 970 A, 800 Hp @ 460V AC
F1250 1250 A, 1000 Hp @ 460V AC

c
Enclosure Type
Code Description
F NEMA Type 4/12 (IP65) (Non-Combination Only)
N Open

d
Input Line Voltage
Open Type
Code Description
B 200…460V AC, 3-phase, 50 and 60 Hz
C 200…575V AC, 3-phase, 50 and 60 Hz
Z 230…690V AC, 3-phase, 50 and 60 Hz (Open Only)
Non-Combination Enclosed Only
H 200…208V AC, 3-phase, 50 and 60 Hz
A 230V AC, 3-phase, 50 and 60 Hz
B 400…460V AC, 3-phase, 50 and 60 Hz
C 500…575V AC, 3-phase, 50 and 60 Hz

e
Control Voltage
Code Description
D 100…240V AC (5…480 A units)
R 24V AC/DC (5…480 A units) (Open Only)
E 110/120V AC (625…1250 A units)
A 230/240V AC (625…1250 A units)

f
Options (Select Only One)
Code Description
Blank Standard
B Pump Control
D Braking Control

g
Options (Non-Combination only)
(see Control Options (open and enclosed) for a full listing)
Code Description
8L Line-Mounted Protective Module (enclosed only)
8M Load-Mounted Protective Module (enclosed only)
8B Line- and Load-Mounted Protective Modules (enclosed only)
Load-side MOVs are not available with Pump and Braking options, or on delta-connected motors. MOVs can be field installed for open type units.

Combination

152H F480    F    BD    B 59 8B
a    b    c    d    e    f    g

a
Bulletin Number
Code Description
152H Solid-State Controller with Fusible Disconnect
153H Solid-State Controller with Circuit Breaker

b
Controller Ratings
Code Description
F5 5 A, 3 Hp @ 460V AC
F25 25 A, 15 Hp @ 460V AC
F43 43 A, 30 Hp @ 460V AC
F60 60 A, 40 Hp @ 460V AC
F85 85 A, 60 Hp @ 460V AC
F108 108 A, 75 Hp @ 460V AC
F135 135 A, 100 Hp @ 460V AC
F201 201 A, 150 Hp @ 460V AC
F251 251 A, 200 Hp @ 460V AC
F317 317 A, 250 Hp @ 460V AC
F361 361 A, 300 Hp @ 460V AC
F480 480 A, 400 Hp @ 460V AC
F625 625 A, 500 Hp @ 460V AC
F780 780 A, 600 Hp @ 460V AC

c
Enclosure Type
Code Description
F NEMA Type 4/12 (IP65)

d
Line Voltage, 120V AC Control Voltage
Code Description
HD 200…208V AC, 3-phase, 50 and 60 Hz
AD 230V AC, 3-phase, 50 and 60 Hz
BD 400…460V AC, 3-phase, 50 and 60 Hz
CD 500…575V AC, 3-phase, 50 and 60 Hz

e
Control Options
Code Description
Blank Standard
B Pump Control
D Braking Control

f
Horsepower
Cat.
No.
Hp
Rating
Cat.
No.
Hp
Rating
Cat.
No.
Hp
Rating
Cat.
No.
Hp
Rating
Cat.
No.
Hp
Rating
33 0.5 39 5 46 40 52 150 60 450
34 0.75 40 7.5 47 50 54 200 61 500
35 1 41 10 48 60 56 250 62 600
36 1.5 42 15 49 75 57 300 63 700
37 2 43 20 50 100 58 350 65 800
38 3 44 25 51 125 59 400 67 1000
45 30

g
Options (see Enclosed Options for a full listing)
Code Description
8L Line-Mounted Protective Module
8M Load-Mounted Protective Module
8B Line- and Load-Mounted Protective Modules
Load-side MOVs are not available with Pump and Braking options, or when used with inside-the-delta connections.