Catalogs > Industrial Controls Catalog > Motor Control, Solid-State > Soft Starters > SMC™ Flex Smart Motor Controllers
SMC™ Flex Smart Motor Controllers
| Introduction | Standards Compliance and Certifications | Modes of Operation | Description | Cat. No. Explanation |
| Product Selection | Modifications | Accessories | Specifications | Approximate Dimensions |
| Build a Catalog Number |
Enclosures other than those listed are available; consult your local Rockwell Automation sales office or Allen-Bradley distributor.
| Rated Voltage [V AC] |
Motor Current [A] | Max. kW, 50 Hz | Max. Hp, 60 Hz | Control Power | Open Type — Line-Connected Motors⋆ | IP65 (Type 4/12) Enclosed Non-Combination Controllers♣ ♦ |
|
| Cat. No. | Cat. No. | ||||||
| 200/208 | 1…5 | — | 1 | 100…240V AC, 50/60 Hz | 150-F5NBD | 150-F5FHD | |
| 24V AC/DC∆ | 150-F5NBR | — | |||||
| 5...25 | — | 5 | 100…240V AC, 50/60 Hz | 150-F25NBD | 150-F25FHD | ||
| 24V AC/DC∆ | 150-F25NBR | — | |||||
| 8.6...43 | — | 10 | 100…240V AC, 50/60 Hz | 150-F43NBD | 150-F43FHD | ||
| 24V AC/DC∆ | 150-F43NBR | — | |||||
| 12...60 | — | 15 | 100…240V AC, 50/60 Hz | 150-F60NBD | 150-F60FHD | ||
| 24V AC/DC∆ | 150-F60NBR | — | |||||
| 17...85 | — | 25 | 100…240V AC, 50/60 Hz | 150-F85NBD | 150-F85FHD | ||
| 24V AC/DC∆ | 150-F85NBR | — | |||||
| 27…108 | — | 30 | 100…240V AC, 50/60 Hz | 150-F108NBD | 150-F108FHD | ||
| 24V AC/DC∆ | 150-F108NBR | — | |||||
| 34…135 | — | 40 | 100…240V AC, 50/60 Hz | 150-F135NBD | 150-F135FHD | ||
| 24V AC/DC∆ | 150-F135NBR | — | |||||
| 67…201 | — | 60 | 100…240V AC, 50/60 Hz | 150-F201NBD | 150-F201FHD | ||
| 24V AC/DC∆ | 150-F201NBR | — | |||||
| 84…251 | — | 75 | 100…240V AC, 50/60 Hz | 150-F251NBD | 150-F251FHD | ||
| 24V AC/DC∆ | 150-F251NBR | — | |||||
| 106…317 | — | 100 | 100…240V AC, 50/60 Hz | 150-F317NBD | 150-F317FHD | ||
| 24V AC/DC∆ | 150-F317NBR | — | |||||
| 120…361 | — | 125 | 100…240V AC, 50/60 Hz | 150-F361NBD | 150-F361FHD | ||
| 24V AC/DC∆ | 150-F361NBR | — | |||||
| 160…480 | — | 150 | 100…240V AC, 50/60 Hz | 150-F480NBD | 150-F480FHD | ||
| 24V AC/DC∆ | 150-F480NBR | — | |||||
| 208…625 | — | 200 | 110/120V AC, 50/60 Hz | 150-F625NBE | ♠ | 150-F625JHE | |
| 230/240V AC, 50/60 Hz | 150-F625NBA | ♠ | 150-F625JHA | ||||
| 260…780 | — | 250 | 110/120V AC, 50/60 Hz | 150-F780NBE | ♠ | 150-F780JHE | |
| 230/240V AC, 50/60 Hz | 150-F780NBA | ♠ | 150-F780JHA | ||||
| 323…970 | — | 350 | 110/120V AC, 50/60 Hz | 150-F970NBE | — | ||
| 230/240V AC, 50/60 Hz | 150-F970NBA | — | |||||
| 416…1250 | — | 400 | 110/120V AC, 50/60 Hz | 150-F1250NBE | — | ||
| 230/240V AC, 50/60 Hz | 150-F1250NBA | — | |||||
| ⋆ Controllers rated 108 A and greater are not equipped with line and load terminal lugs. See Terminal Lug Kits (108…1250 A) for terminal lug kits. | |||||||
| Motor FLA rating should fall within specified current range for unit to operate properly. Special consideration should be given when using a motor with a potentially high starting current (greater than ten times motor FLA) with the SMC Flex in the "Full Voltage" starting mode. Contact Rockwell Automation technical support for further guidance. | |||||||
| ♣ These controllers require a separate 100…240V, 50/60 Hz single-phase control source. To add a control circuit transformer to the enclosure, add the appropriate option code to the catalog string. | |||||||
| ∆ Separate 120V or 240V single-phase power supply is required for fan operation. | |||||||
| ♦ Line and load termination are provided as standard. | |||||||
| ♠ Available in IP54 (Type 12) enclosure only. | |||||||
| Rated Voltage [V AC] |
Motor Current [A] | Max. kW, 50 Hz | Max. Hp, 60 Hz | Control Power | Open Type — Line-Connected Motors⋆ | IP65 (Type 4/12) Enclosed Non-Combination Controllers♣ ♦ |
|
| Cat. No. | Cat. No. | ||||||
| 230 | 1…5 | 1.1 | 1 | 100…240V AC, 50/60 Hz | 150-F5NBD | 150-F5FAD | |
| 24V AC/DC∆ | 150-F5NBR | — | |||||
| 5...25 | 5.5 | 7.5 | 100…240V AC, 50/60 Hz | 150-F25NBD | 150-F25FAD | ||
| 24V AC/DC∆ | 150-F25NBR | — | |||||
| 8.6...43 | 11 | 15 | 100…240V AC, 50/60 Hz | 150-F43NBD | 150-F43FAD | ||
| 24V AC/DC∆ | 150-F43NBR | — | |||||
| 12...60 | 15 | 20 | 100…240V AC, 50/60 Hz | 150-F60NBD | 150-F60FAD | ||
| 24V AC/DC∆ | 150-F60NBR | — | |||||
| 17...85 | 22 | 30 | 100…240V AC, 50/60 Hz | 150-F85NBD | 150-F85FAD | ||
| 24V AC/DC∆ | 150-F85NBR | — | |||||
| 27…108 | 30 | 40 | 100…240V AC, 50/60 Hz | 150-F108NBD | 150-F108FAD | ||
| 24V AC/DC∆ | 150-F108NBR | — | |||||
| 34…135 | 37 | 50 | 100…240V AC, 50/60 Hz | 150-F135NBD | 150-F135FAD | ||
| 24V AC/DC∆ | 150-F135NBR | — | |||||
| 67…201 | 55 | 75 | 100…240V AC, 50/60 Hz | 150-F201NBD | 150-F201FAD | ||
| 24V AC/DC∆ | 150-F201NBR | — | |||||
| 84…251 | 75 | 100 | 100…240V AC, 50/60 Hz | 150-F251NBD | 150-F251FAD | ||
| 24V AC/DC∆ | 150-F251NBR | — | |||||
| 106…317 | 90 | 125 | 100…240V AC, 50/60 Hz | 150-F317NBD | 150-F317FAD | ||
| 24V AC/DC∆ | 150-F317NBR | — | |||||
| 120…361 | 110 | 150 | 100…240V AC, 50/60 Hz | 150-F361NBD | 150-F361FAD | ||
| 24V AC/DC∆ | 150-F361NBR | — | |||||
| 160…480 | 132 | 200 | 100…240V AC, 50/60 Hz | 150-F480NBD | 150-F480FAD | ||
| 24V AC/DC∆ | 150-F480NBR | — | |||||
| 208…625 | 200 | 250 | 110/120V AC, 50/60 Hz | 150-F625NBE | ♠ | 150-F625JAE | |
| 230/240V AC, 50/60 Hz | 150-F625NBA | ♠ | 150-F625JAA | ||||
| 260…780 | 250 | 300 | 110/120V AC, 50/60 Hz | 150-F780NBE | ♠ | 150-F780JAE | |
| 230/240V AC, 50/60 Hz | 150-F780NBA | ♠ | 150-F780JAA | ||||
| 323…970 | 315 | 400 | 110/120V AC, 50/60 Hz | 150-F970NBE | — | ||
| 230/240V AC, 50/60 Hz | 150-F970NBA | — | |||||
| 416…1250 | 400 | 500 | 110/120V AC, 50/60 Hz | 150-F1250NBE | — | ||
| 230/240V AC, 50/60 Hz | 150-F1250NBA | — | |||||
| ⋆ Controllers rated 108 A and greater are not equipped with line and load terminal lugs. See Terminal Lug Kits (108…1250 A) for terminal lug kits. | |||||||
| Motor FLA rating should fall within specified current range for unit to operate properly. Special consideration should be given when using a motor with a potentially high starting current (greater than ten times motor FLA) with the SMC Flex in the "Full Voltage" starting mode. Contact Rockwell Automation technical support for further guidance. | |||||||
| ♣ These controllers require a separate 100…240V, 50/60 Hz single-phase control source. To add a control circuit transformer to the enclosure, add the appropriate option code to the catalog string. | |||||||
| ∆ Separate 120V or 240V single-phase power supply is required for fan operation. | |||||||
| ♦ Line and load termination are provided as standard. | |||||||
| ♠ Available in IP54 (Type 12) enclosure only. | |||||||
| Rated Voltage [V AC] |
Motor Current [A] | Max. kW, 50 Hz | Max. Hp, 60 Hz | Control Power | Open Type — Line-Connected Motors⋆ | IP65 (Type 4/12) Enclosed Non-Combination Controllers♣ ♦ |
|
| Cat. No. | Cat. No. | ||||||
| 400/415/460 | 1…5 | 2.2 | 3 | 100…240V AC, 50/60 Hz | 150-F5NBD | 150-F5FBD | |
| 24V AC/DC∆ | 150-F5NBR | — | |||||
| 5...25 | 11 | 15 | 100…240V AC, 50/60 Hz | 150-F25NBD | 150-F25FBD | ||
| 24V AC/DC∆ | 150-F25NBR | — | |||||
| 8.6...43 | 22 | 30 | 100…240V AC, 50/60 Hz | 150-F43NBD | 150-F43FBD | ||
| 24V AC/DC∆ | 150-F43NBR | — | |||||
| 12...60 | 30 | 40 | 100…240V AC, 50/60 Hz | 150-F60NBD | 150-F60FBD | ||
| 24V AC/DC∆ | 150-F60NBR | — | |||||
| 17...85 | 45 | 60 | 100…240V AC, 50/60 Hz | 150-F85NBD | 150-F85FBD | ||
| 24V AC/DC∆ | 150-F85NBR | — | |||||
| 27…108 | 55 | 75 | 100…240V AC, 50/60 Hz | 150-F108NBD | 150-F108FBD | ||
| 24V AC/DC∆ | 150-F108NBR | — | |||||
| 34…135 | 75 | 100 | 100…240V AC, 50/60 Hz | 150-F135NBD | 150-F135FBD | ||
| 24V AC/DC∆ | 150-F135NBR | — | |||||
| 67…201 | 110 | 150 | 100…240V AC, 50/60 Hz | 150-F201NBD | 150-F201FBD | ||
| 24V AC/DC∆ | 150-F201NBR | — | |||||
| 84…251 | 132 | 200 | 100…240V AC, 50/60 Hz | 150-F251NBD | 150-F251FBD | ||
| 24V AC/DC∆ | 150-F251NBR | — | |||||
| 106…317 | 160 | 250 | 100…240V AC, 50/60 Hz | 150-F317NBD | 150-F317FBD | ||
| 24V AC/DC∆ | 150-F317NBR | — | |||||
| 120…361 | 200 | 300 | 100…240V AC, 50/60 Hz | 150-F361NBD | 150-F361FBD | ||
| 24V AC/DC∆ | 150-F361NBR | — | |||||
| 160…480 | 250 | 400 | 100…240V AC, 50/60 Hz | 150-F480NBD | 150-F480FBD | ||
| 24V AC/DC∆ | 150-F480NBR | — | |||||
| 208…625 | 355 | 500 | 110/120V AC, 50/60 Hz | 150-F625NBE | ♠ | 150-F625JBE | |
| 230/240V AC, 50/60 Hz | 150-F625NBA | ♠ | 150-F625JBA | ||||
| 260…780 | 450 | 600 | 110/120V AC, 50/60 Hz | 150-F780NBE | ♠ | 150-F780JBE | |
| 230/240V AC, 50/60 Hz | 150-F780NBA | ♠ | 150-F780JBA | ||||
| 323…970 | 560 | 800 | 110/120V AC, 50/60 Hz | 150-F970NBE | — | ||
| 230/240V AC, 50/60 Hz | 150-F970NBA | — | |||||
| 416…1250 | 710 | 1000 | 110/120V AC, 50/60 Hz | 150-F1250NBE | — | ||
| 230/240V AC, 50/60 Hz | 150-F1250NBA | — | |||||
| ⋆ Controllers rated 108 A and greater are not equipped with line and load terminal lugs. See Terminal Lug Kits (108…1250 A) for terminal lug kits. | |||||||
| Motor FLA rating should fall within specified current range for unit to operate properly. Special consideration should be given when using a motor with a potentially high starting current (greater than ten times motor FLA) with the SMC Flex in the "Full Voltage" starting mode. Contact Rockwell Automation technical support for further guidance. | |||||||
| ♣ These controllers require a separate 100…240V, 50/60 Hz single-phase control source. To add a control circuit transformer to the enclosure, add the appropriate option code to the catalog string. | |||||||
| ∆ Separate 120V or 240V single-phase power supply is required for fan operation. | |||||||
| ♦ Line and load termination are provided as standard. | |||||||
| ♠ Available in IP54 (Type 12) enclosure only. | |||||||
| Rated Voltage [V AC] |
Motor Current [A] | Max. kW, 50 Hz | Max. Hp, 60 Hz | Control Power | Open Type — Line-Connected Motors⋆ | IP65 (Type 4/12) Enclosed Non-Combination Controllers♣ ♦ |
|
| Cat. No. | Cat. No. | ||||||
| 500/575 | 1...5 | 2.2 | 3 | 100…240V AC, 50/60 Hz | 150-F5NCD | 150-F5FCD | |
| 24V AC/DC∆ | 150-F5NCR | — | |||||
| 5...25 | 15 | 20 | 100…240V AC, 50/60 Hz | 150-F25NCD | 150-F25FCD | ||
| 24V AC/DC∆ | 150-F25NCR | — | |||||
| 8.6...43 | 22 | 40 | 100…240V AC, 50/60 Hz | 150-F43NCD | 150-F43FCD | ||
| 24V AC/DC∆ | 150-F43NCR | — | |||||
| 12...60 | 37 | 50 | 100…240V AC, 50/60 Hz | 150-F60NCD | 150-F60FCD | ||
| 24V AC/DC∆ | 150-F60NCR | — | |||||
| 17...85 | 55 | 75 | 100…240V AC, 50/60 Hz | 150-F85NCD | 150-F85FCD | ||
| 24V AC/DC∆ | 150-F85NCR | — | |||||
| 27…108 | 75 | 100 | 100…240V AC, 50/60 Hz | 150-F108NCD | 150-F108FCD | ||
| 24V AC/DC∆ | 150-F108NCR | — | |||||
| 34…135 | 90 | 125 | 100…240V AC, 50/60 Hz | 150-F135NCD | 150-F135FCD | ||
| 24V AC/DC∆ | 150-F135NCR | — | |||||
| 67…201 | 132 | 200 | 100…240V AC, 50/60 Hz | 150-F201NCD | 150-F201FCD | ||
| 24V AC/DC∆ | 150-F201NCR | — | |||||
| 84…251 | 160 | 250 | 100…240V AC, 50/60 Hz | 150-F251NCD | 150-F251FCD | ||
| 24V AC/DC∆ | 150-F251NCR | — | |||||
| 106…317 | 200 | 300 | 100…240V AC, 50/60 Hz | 150-F317NCD | 150-F317FCD | ||
| 24V AC/DC∆ | 150-F317NCR | — | |||||
| 120…361 | 250 | 350 | 100…240V AC, 50/60 Hz | 150-F361NCD | 150-F361FCD | ||
| 24V AC/DC∆ | 150-F361NCR | — | |||||
| 160…480 | 315 | 500 | 100…240V AC, 50/60 Hz | 150-F480NCD | 150-F480FCD | ||
| 24V AC/DC∆ | 150-F480NCR | — | |||||
| 208…625 | 450 | 600 | 110/120V AC, 50/60 Hz | 150-F625NCE | ♠ | 150-F625JCE | |
| 230/240V AC, 50/60 Hz | 150-F625NCA | ♠ | 150-F625JCA | ||||
| 260…780 | 560 | 800 | 110/120V AC, 50/60 Hz | 150-F780NCE | ♠ | 150-F780JCE | |
| 230/240V AC, 50/60 Hz | 150-F780NCA | ♠ | 150-F780JCA | ||||
| 323…970 | 710 | 1000 | 110/120V AC, 50/60 Hz | 150-F970NCE | — | ||
| 230/240V AC, 50/60 Hz | 150-F970NCA | — | |||||
| 416…1250 | 900 | 1300 | 110/120V AC, 50/60 Hz | 150-F1250NCE | — | ||
| 230/240V AC, 50/60 Hz | 150-F1250NCA | — | |||||
| ⋆ Controllers rated 108 A and greater are not equipped with line and load terminal lugs. See Terminal Lug Kits (108…1250 A) for terminal lug kits. | |||||||
| Motor FLA rating should fall within specified current range for unit to operate properly. Special consideration should be given when using a motor with a potentially high starting current (greater than ten times motor FLA) with the SMC Flex in the "Full Voltage" starting mode. Contact Rockwell Automation technical support for further guidance. | |||||||
| ♣ These controllers require a separate 100…240V, 50/60 Hz single-phase control source. To add a control circuit transformer to the enclosure, add the appropriate option code to the catalog string. | |||||||
| ∆ Separate 120V or 240V single-phase power supply is required for fan operation. | |||||||
| ♦ Line and load termination are provided as standard. | |||||||
| ♠ Available in IP54 (Type 12) enclosure only. | |||||||
| Rated Voltage [V AC] |
Motor Current [A] | Max. kW, 50 Hz | Max. Hp, 60 Hz | Control Power | Open Type — Line-Connected Motors⋆ |
| Cat. No. | |||||
| 690/Y§ | 27…108 | 90 | 100 | 100…240V AC, 50/60 Hz | 150-F108NZD |
| 34…135 | 132 | 175 | 100…240V AC, 50/60 Hz | 150-F135NZD | |
| 67…201 | 160 | 200 | 100…240V AC, 50/60 Hz | 150-F201NZD | |
| 84…251 | 200 | 250 | 100…240V AC, 50/60 Hz | 150-F251NZD | |
| 106…317 | 315 | 400 | 100…240V AC, 50/60 Hz | 150-F317NZD | |
| 120…361 | 355 | 450 | 100…240V AC, 50/60 Hz | 150-F361NZD | |
| 160…480 | 450 | 600 | 100…240V AC, 50/60 Hz | 150-F480NZD | |
| 208…625 | 630 | 800 | 110/120V AC, 50/60 Hz | 150-F625NZE | |
| 230/240V AC, 50/60 Hz | 150-F625NZA | ||||
| 260…780 | 800 | 1000 | 110/120V AC, 50/60 Hz | 150-F780NZE | |
| 230/240V AC, 50/60 Hz | 150-F780NZA | ||||
| 323…970 | 1000 | 1300 | 110/120V AC, 50/60 Hz | 150-F970NZE | |
| 230/240V AC, 50/60 Hz | 150-F970NZA | ||||
| 416…1250 | 1200 | 1600 | 110/120V AC, 50/60 Hz | 150-F1250NZE | |
| 230/240V AC, 50/60 Hz | 150-F1250NZA | ||||
| ⋆ Controllers rated 108 A and greater are not equipped with line and load terminal lugs. See Terminal Lug Kits (108…1250 A) for terminal lug kits. | |||||
| Motor FLA rating should fall within specified current range for unit to operate properly. Special consideration should be given when using a motor with a potentially high starting current (greater than ten times motor FLA) with the SMC Flex in the "Full Voltage" starting mode. Contact Rockwell Automation technical support for further guidance. | |||||
| ♣ These controllers require a separate 100…240V, 50/60 Hz single-phase control source. To add a control circuit transformer to the enclosure, add the appropriate option code to the catalog string. | |||||
| ∆ Separate 120V or 240V single-phase power supply is required for fan operation. | |||||
| ♦ Line and load termination are provided as standard. | |||||
| § To be used only in a Y-type system. | |||||
Open Type Controllers — For use with Delta-Connected Motors
| Rated Voltage [V AC] |
Motor Current [A] | Max. kW, 50 Hz | Max. Hp, 60 Hz | Control Power | Open Type⋆ |
| Cat. No. | |||||
| 200/208 | 1.7…8.7 | — | 2 | 100…240V AC, 50/60 Hz | 150-F5NBD |
| 24V AC/DC∆ | 150-F5NBR | ||||
| 8.7…43 | — | 10 | 100…240V AC, 50/60 Hz | 150-F25NBD | |
| 24V AC/DC∆ | 150-F25NBR | ||||
| 14.9…74 | — | 20 | 100…240V AC, 50/60 Hz | 150-F43NBD | |
| 24V AC/DC∆ | 150-F43NBR | ||||
| 20.8…104 | — | 30 | 100…240V AC, 50/60 Hz | 150-F60NBD | |
| 24V AC/DC∆ | 150-F60NBR | ||||
| 29.4…147 | — | 40 | 100…240V AC, 50/60 Hz | 150-F85NBD | |
| 24V AC/DC∆ | 150-F85NBR | ||||
| 47…187 | — | 60 | 100…240V AC, 50/60 Hz | 150-F108NBD | |
| 24V AC/DC∆ | 150-F108NBR | ||||
| 59…234 | — | 75 | 100…240V AC, 50/60 Hz | 150-F135NBD | |
| 24V AC/DC∆ | 150-F135NBR | ||||
| 116…348 | — | 100 | 100…240V AC, 50/60 Hz | 150-F201NBD | |
| 24V AC/DC∆ | 150-F201NBR | ||||
| 145…435 | — | 150 | 100…240V AC, 50/60 Hz | 150-F251NBD | |
| 24V AC/DC∆ | 150-F251NBR | ||||
| 183…549 | — | 200 | 100…240V AC, 50/60 Hz | 150-F317NBD | |
| 24V AC/DC∆ | 150-F317NBR | ||||
| 208…625 | — | 200 | 100…240V AC, 50/60 Hz | 150-F361NBD | |
| 24V AC/DC∆ | 150-F361NBR | ||||
| 277…831 | — | 300 | 100…240V AC, 50/60 Hz | 150-F480NBD | |
| 24V AC/DC∆ | 150-F480NBR | ||||
| 283…850 | — | 300 | 110/120V AC, 50/60 Hz | 150-F625NBE | |
| 230/240V AC, 50/60 Hz | 150-F625NBA | ||||
| 300…900 | — | 300 | 110/120V AC, 50/60 Hz | 150-F780NBE | |
| 230/240V AC, 50/60 Hz | 150-F780NBA | ||||
| 400…1200 | — | 400 | 110/120V AC, 50/60 Hz | 150-F970NBE | |
| 230/240V AC, 50/60 Hz | 150-F970NBA | ||||
| 533…1600 | — | 500 | 110/120V AC, 50/60 Hz | 150-F1250NBE | |
| 230/240V AC, 50/60 Hz | 150-F1250NBA | ||||
| ⋆ Controllers rated 108 A and greater are not equipped with line and load terminal lugs. See Terminal Lug Kits (108…1250 A) for terminal lug kits. | |||||
| Motor FLA rating should fall within specified current range for unit to operate properly. Special consideration should be given when using a motor with a potentially high starting current (greater than ten times motor FLA) with the SMC Flex in the "Full Voltage" starting mode. Contact Rockwell Automation technical support for further guidance. | |||||
| ∆ Separate 120V or 240V single-phase power supply is required for fan operation. | |||||
| Rated Voltage [V AC] |
Motor Current [A] | Max. kW, 50 Hz | Max. Hp, 60 Hz | Control Power | Open Type⋆ |
| Cat. No. | |||||
| 230 | 1.7…8.7 | 2.2 | 2 | 100…240V AC, 50/60 Hz | 150-F5NBD |
| 24V AC/DC∆ | 150-F5NBR | ||||
| 8.7…43 | 11 | 15 | 100…240V AC, 50/60 Hz | 150-F25NBD | |
| 24V AC/DC∆ | 150-F25NBR | ||||
| 14.9…74 | 22 | 25 | 100…240V AC, 50/60 Hz | 150-F43NBD | |
| 24V AC/DC∆ | 150-F43NBR | ||||
| 20.8…104 | 30 | 40 | 100…240V AC, 50/60 Hz | 150-F60NBD | |
| 24V AC/DC∆ | 150-F60NBR | ||||
| 29.4…147 | 45 | 50 | 100…240V AC, 50/60 Hz | 150-F85NBD | |
| 24V AC/DC∆ | 150-F85NBR | ||||
| 47…187 | 55 | 60 | 100…240V AC, 50/60 Hz | 150-F108NBD | |
| 24V AC/DC∆ | 150-F108NBR | ||||
| 59…234 | 75 | 75 | 100…240V AC, 50/60 Hz | 150-F135NBD | |
| 24V AC/DC∆ | 150-F135NBR | ||||
| 116…348 | 110 | 125 | 100…240V AC, 50/60 Hz | 150-F201NBD | |
| 24V AC/DC∆ | 150-F201NBR | ||||
| 145…435 | 132 | 150 | 100…240V AC, 50/60 Hz | 150-F251NBD | |
| 24V AC/DC∆ | 150-F251NBR | ||||
| 183…549 | 160 | 200 | 100…240V AC, 50/60 Hz | 150-F317NBD | |
| 24V AC/DC∆ | 150-F317NBR | ||||
| 208…625 | 200 | 250 | 100…240V AC, 50/60 Hz | 150-F361NBD | |
| 24V AC/DC∆ | 150-F361NBR | ||||
| 277…831 | 250 | 350 | 100…240V AC, 50/60 Hz | 150-F480NBD | |
| 24V AC/DC∆ | 150-F480NBR | ||||
| 283…850 | 250 | 350 | 110/120V AC, 50/60 Hz | 150-F625NBE | |
| 230/240V AC, 50/60 Hz | 150-F625NBA | ||||
| 300…900 | 250 | 350 | 110/120V AC, 50/60 Hz | 150-F780NBE | |
| 230/240V AC, 50/60 Hz | 150-F780NBA | ||||
| 400…1200 | 400 | 400 | 110/120V AC, 50/60 Hz | 150-F970NBE | |
| 230/240V AC, 50/60 Hz | 150-F970NBA | ||||
| 533…1600 | 500 | 600 | 110/120V AC, 50/60 Hz | 150-F1250NBE | |
| 230/240V AC, 50/60 Hz | 150-F1250NBA | ||||
| ⋆ Controllers rated 108 A and greater are not equipped with line and load terminal lugs. See Terminal Lug Kits (108…1250 A) for terminal lug kits. | |||||
| Motor FLA rating should fall within specified current range for unit to operate properly. Special consideration should be given when using a motor with a potentially high starting current (greater than ten times motor FLA) with the SMC Flex in the "Full Voltage" starting mode. Contact Rockwell Automation technical support for further guidance. | |||||
| ∆ Separate 120V or 240V single-phase power supply is required for fan operation. | |||||
| Rated Voltage [V AC] |
Motor Current [A] | Max. kW, 50 Hz | Max. Hp, 60 Hz | Control Power | Open Type⋆ |
| Cat. No. | |||||
| 400/415/460 | 1.7…8.7 | 4 | 5 | 100…240V AC, 50/60 Hz | 150-F5NBD |
| 24V AC/DC∆ | 150-F5NBR | ||||
| 8.7…43 | 22 | 30 | 100…240V AC, 50/60 Hz | 150-F25NBD | |
| 24V AC/DC∆ | 150-F25NBR | ||||
| 14.9…74 | 37 | 50 | 100…240V AC, 50/60 Hz | 150-F43NBD | |
| 24V AC/DC∆ | 150-F43NBR | ||||
| 20.8…104 | 55 | 75 | 100…240V AC, 50/60 Hz | 150-F60NBD | |
| 24V AC/DC∆ | 150-F60NBR | ||||
| 29.4…147 | 75 | 100 | 100…240V AC, 50/60 Hz | 150-F85NBD | |
| 24V AC/DC∆ | 150-F85NBR | ||||
| 47…187 | 90 | 150 | 100…240V AC, 50/60 Hz | 150-F108NBD | |
| 24V AC/DC∆ | 150-F108NBR | ||||
| 59…234 | 132 | 150 | 100…240V AC, 50/60 Hz | 150-F135NBD | |
| 24V AC/DC∆ | 150-F135NBR | ||||
| 116…348 | 160 | 250 | 100…240V AC, 50/60 Hz | 150-F201NBD | |
| 24V AC/DC∆ | 150-F201NBR | ||||
| 145…435 | 250 | 350 | 100…240V AC, 50/60 Hz | 150-F251NBD | |
| 24V AC/DC∆ | 150-F251NBR | ||||
| 183…549 | 315 | 450 | 100…240V AC, 50/60 Hz | 150-F317NBD | |
| 24V AC/DC∆ | 150-F317NBR | ||||
| 208…625 | 355 | 500 | 100…240V AC, 50/60 Hz | 150-F361NBD | |
| 24V AC/DC∆ | 150-F361NBR | ||||
| 277…831 | 450 | 700 | 100…240V AC, 50/60 Hz | 150-F480NBD | |
| 24V AC/DC∆ | 150-F480NBR | ||||
| 283…850 | 500 | 700 | 110/120V AC, 50/60 Hz | 150-F625NBE | |
| 230/240V AC, 50/60 Hz | 150-F625NBA | ||||
| 300…900 | 500 | 700 | 110/120V AC, 50/60 Hz | 150-F780NBE | |
| 230/240V AC, 50/60 Hz | 150-F780NBA | ||||
| 400…1200 | 710 | 1000 | 110/120V AC, 50/60 Hz | 150-F970NBE | |
| 230/240V AC, 50/60 Hz | 150-F970NBA | ||||
| 533…1600 | 900 | 1400 | 110/120V AC, 50/60 Hz | 150-F1250NBE | |
| 230/240V AC, 50/60 Hz | 150-F1250NBA | ||||
| ⋆ Controllers rated 108 A and greater are not equipped with line and load terminal lugs. See Terminal Lug Kits (108…1250 A) for terminal lug kits. | |||||
| Motor FLA rating should fall within specified current range for unit to operate properly. Special consideration should be given when using a motor with a potentially high starting current (greater than ten times motor FLA) with the SMC Flex in the "Full Voltage" starting mode. Contact Rockwell Automation technical support for further guidance. | |||||
| ∆ Separate 120V or 240V single-phase power supply is required for fan operation. | |||||
| Rated Voltage [V AC] |
Motor Current [A] | Max. kW, 50 Hz | Max. Hp, 60 Hz | Control Power | Open Type⋆ |
| Cat. No. | |||||
| 500/575 | 1.7…8.7 | 5.5 | 7.5 | 100…240V AC, 50/60 Hz | 150-F5NCD |
| 24V AC/DC∆ | 150-F5NCR | ||||
| 8.7…43 | 15 | 40 | 100…240V AC, 50/60 Hz | 150-F25NCD | |
| 24V AC/DC∆ | 150-F25NCR | ||||
| 14.9…74 | 45 | 60 | 100…240V AC, 50/60 Hz | 150-F43NCD | |
| 24V AC/DC∆ | 150-F43NCR | ||||
| 20.8…104 | 55 | 100 | 100…240V AC, 50/60 Hz | 150-F60NCD | |
| 24V AC/DC∆ | 150-F60NCR | ||||
| 29.4…147 | 90 | 150 | 100…240V AC, 50/60 Hz | 150-F85NCD | |
| 24V AC/DC∆ | 150-F85NCR | ||||
| 47…187 | 132 | 150 | 100…240V AC, 50/60 Hz | 150-F108NCD | |
| 24V AC/DC∆ | 150-F108NCR | ||||
| 59…234 | 160 | 200 | 100…240V AC, 50/60 Hz | 150-F135NCD | |
| 24V AC/DC∆ | 150-F135NCR | ||||
| 116…348 | 250 | 300 | 100…240V AC, 50/60 Hz | 150-F201NCD | |
| 24V AC/DC∆ | 150-F201NCR | ||||
| 145…435 | 315 | 400 | 100…240V AC, 50/60 Hz | 150-F251NCD | |
| 24V AC/DC∆ | 150-F251NCR | ||||
| 183…549 | 400 | 500 | 100…240V AC, 50/60 Hz | 150-F317NCD | |
| 24V AC/DC∆ | 150-F317NCR | ||||
| 208…625 | 450 | 600 | 100…240V AC, 50/60 Hz | 150-F361NCD | |
| 24V AC/DC∆ | 150-F361NCR | ||||
| 277…831 | 560 | 900 | 100…240V AC, 50/60 Hz | 150-F480NCD | |
| 24V AC/DC∆ | 150-F480NCR | ||||
| 283…850 | 560 | 900 | 110/120V AC, 50/60 Hz | 150-F625NCE | |
| 230/240V AC, 50/60 Hz | 150-F625NCA | ||||
| 300…900 | 630 | 900 | 110/120V AC, 50/60 Hz | 150-F780NCE | |
| 230/240V AC, 50/60 Hz | 150-F780NCA | ||||
| 400…1200 | 800 | 1300 | 110/120V AC, 50/60 Hz | 150-F970NCE | |
| 230/240V AC, 50/60 Hz | 150-F970NCA | ||||
| 533…1600 | 1100 | 1600 | 110/120V AC, 50/60 Hz | 150-F1250NCE | |
| 230/240V AC, 50/60 Hz | 150-F1250NCA | ||||
| ⋆ Controllers rated 108 A and greater are not equipped with line and load terminal lugs. See Terminal Lug Kits (108…1250 A) for terminal lug kits. | |||||
| Motor FLA rating should fall within specified current range for unit to operate properly. Special consideration should be given when using a motor with a potentially high starting current (greater than ten times motor FLA) with the SMC Flex in the "Full Voltage" starting mode. Contact Rockwell Automation technical support for further guidance. | |||||
| ∆ Separate 120V or 240V single-phase power supply is required for fan operation. | |||||
Combination Line-Connected Controllers — IP65 (Type 4/12) Enclosed with Fusible Disconnect or Circuit Breaker
| Build a Catalog Number |
These controllers include line and load terminations. Enclosures other than those listed are available; consult your local Rockwell Automation sales office or Allen-Bradley distributor. All 153 bulletin numbers are supplied with thermal magnetic circuit breakers.
The Fusible Disconnects do not come with fuses.
| Rated Voltage [V AC] |
kW, 50 Hz | Hp, 60 Hz | Controller Current Rating [A] |
IP65 (Type 4/12) Enclosed Combination Controllers with Fusible Disconnect⋆ | IP65 (Type 4/12) Enclosed Combination Controllers with Circuit Breaker⋆ | ||
| Cat. No.♣ | Cat. No. | ||||||
| 200 | — | 0.5 | 5 | 152H-F5FHD-33 | 153H-F5FHD-33 | ||
| — | 0.75 | 5 | 152H-F5FHD-34 | 153H-F5FHD-34 | |||
| — | 1 | 5 | 152H-F5FHD-35 | 153H-F5FHD-35 | |||
| — | 1.5 | 25 | 152H-F25FHD-36 | 153H-F25FHD-36 | |||
| — | 2 | 25 | 152H-F25FHD-37 | 153H-F25FHD-37 | |||
| — | 3 | 25 | 152H-F25FHD-38 | 153H-F25FHD-38 | |||
| — | 5 | 25 | 152H-F25FHD-39 | 153H-F25FHD-39 | |||
| — | 5 | 25 | 152H-F25FHD-40 | 153H-F25FHD-40 | |||
| — | 10 | 43 | 152H-F43FHD-41 | 153H-F43FHD-41 | |||
| — | 15 | 60 | 152H-F60FHD-42 | 153H-F60FHD-42 | |||
| — | 20 | 85 | 152H-F85FHD-43 | 153H-F85FHD-43 | |||
| — | 25 | 85 | 152H-F85FHD-44 | 153H-F85FHD-44 | |||
| — | 30 | 108 | 152H-F108FHD-45 | 153H-F108FHD-45 | |||
| — | 40 | 135 | 152H-F135FHD-46 | 153H-F135FHD-46 | |||
| — | 50 | 201 | 152H-F201FHD-47 | 153H-F201FHD-47 | |||
| — | 60 | 201 | 152H-F201FHD-48 | 153H-F201FHD-48 | |||
| — | 75 | 251 | 152H-F251FHD-49 | 153H-F251FHD-49 | |||
| — | 100 | 317 | 152H-F317FHD-50 | 153H-F317FHD-50 | |||
| — | 125 | 361 | 152H-F361FHD-51 | 153H-F361FHD-51 | |||
| — | 150 | 480 | 152H-F480FHD-52 | 153H-F480FHD-52 | |||
| — | 200 | 625 | ∆ | 152H-F625JHD-54 | ∆ | 153H-F625JHD-54 | |
| — | 250 | 780 | ∆ | 152H-F780JHD-56 | ∆ | 153H-F780JHD-56 | |
| 230 | 0.37 | 0.5 | 5 | 152H-F5FAD-33 | 153H-F5FAD-33 | ||
| 0.55 | 0.75 | 5 | 152H-F5FAD-34 | 153H-F5FAD-34 | |||
| 0.75 | 1 | 5 | 152H-F5FAD-35 | 153H-F5FAD-35 | |||
| 1.1 | 1.5 | 25 | 152H-F25FAD-36 | 153H-F25FAD-36 | |||
| 1.5 | 2 | 25 | 152H-F25FAD-37 | 153H-F25FAD-37 | |||
| 2.2 | 3 | 25 | 152H-F25FAD-38 | 153H-F25FAD-38 | |||
| 3.7 | 5 | 25 | 152H-F25FAD-39 | 153H-F25FAD-39 | |||
| 5.5 | 7.5 | 25 | 152H-F25FAD-40 | 153H-F25FAD-40 | |||
| 7.5 | 10 | 43 | 152H-F43FAD-41 | 153H-F43FAD-41 | |||
| 11 | 15 | 43 | 152H-F43FAD-42 | 153H-F43FAD-42 | |||
| 15 | 20 | 60 | 152H-F60FAD-43 | 153H-F60FAD-43 | |||
| 18.5 | 25 | 85 | 152H-F85FAD-44 | 153H-F85FAD-44 | |||
| 22 | 30 | 85 | 152H-F85FAD-45 | 153H-F85FAD-45 | |||
| 30 | 40 | 108 | 152H-F108FAD-46 | 153H-F108FAD-46 | |||
| 37 | 50 | 135 | 152H-F135FAD-47 | 153H-F135FAD-47 | |||
| 45 | 60 | 201 | 152H-F201FAD-48 | 153H-F201FAD-48 | |||
| 55 | 75 | 201 | 152H-F201FAD-49 | 153H-F201FAD-49 | |||
| 75 | 100 | 251 | 152H-F251FAD-50 | 153H-F251FAD-50 | |||
| 90 | 125 | 317 | 152H-F317FAD-51 | 153H-F317FAD-51 | |||
| 110 | 150 | 361 | 152H-F361FAD-52 | 153H-F361FAD-52 | |||
| 132 | 200 | 480 | ∆ | 152H-F480JAD-54 | 153H-F480FAD-54 | ||
| 185 | 250 | 625 | ∆ | 152H-F625JAD-56 | ∆ | 153H-F625JAD-56 | |
| 220 | 300 | 780 | ∆ | 152H-F780JAD-57 | ∆ | 153H-F780JAD-57 | |
| ⋆ These controllers require a separate 100…240V, 50/60 Hz single-phase control source. To add a control circuit transformer to the enclosure, add the appropriate option code to the catalog string. | |||||||
| The nominal current rating for the combination package may differ from the controller, based on the horsepower. Consult your local Rockwell Automation sales office or Allen-Bradley distributor. | |||||||
| ♣ Provided with Class J or L fuse clips as standard. | |||||||
| ∆ Available in IP54 (Type 12) enclosure only. | |||||||
| Rated Voltage [V AC] |
kW, 50 Hz | Hp, 60 Hz | Controller Current Rating [A] |
IP65 (Type 4/12) Enclosed Combination Controllers with Fusible Disconnect⋆ | IP65 (Type 4/12) Enclosed Combination Controllers with Circuit Breaker⋆ | ||
| Cat. No.♣ | Cat. No. | ||||||
| 400/460 | 0.37 | 0.5 | 5 | 152H-F5FBD-33 | 153H-F5FBD-33 | ||
| 0.55 | 0.75 | 5 | 152H-F5FBD-34 | 153H-F5FBD-34 | |||
| 0.75 | 1 | 5 | 152H-F5FBD-35 | 153H-F5FBD-35 | |||
| 1.1 | 1.5 | 5 | 152H-F5FBD-36 | 153H-F5FBD-36 | |||
| 1.5 | 2 | 5 | 152H-F5FBD-37 | 153H-F5FBD-37 | |||
| 2.2 | 3 | 5 | 152H-F5FBD-38 | 153H-F5FBD-38 | |||
| 3.7 | 5 | 25 | 152H-F25FBD-39 | 153H-F25FBD-39 | |||
| 5.5 | 7.5 | 25 | 152H-F25FBD-40 | 153H-F25FBD-40 | |||
| 7.5 | 10 | 25 | 152H-F25FBD-41 | 153H-F25FBD-41 | |||
| 11 | 15 | 25 | 152H-F25FBD-42 | 153H-F25FBD-42 | |||
| 15 | 20 | 43 | 152H-F43FBD-43 | 153H-F25FBD-43 | |||
| 18.5 | 25 | 43 | 152H-F43FBD-44 | 153H-F43FBD-44 | |||
| 22 | 30 | 43 | 152H-F43FBD-45 | 153H-F43FBD-45 | |||
| 30 | 40 | 60 | 152H-F60FBD-46 | 153H-F60FBD-46 | |||
| 37 | 50 | 85 | 152H-F85FBD-47 | 153H-F85FBD-47 | |||
| 45 | 60 | 85 | 152H-F85FBD-48 | 153H-F85FBD-48 | |||
| 55 | 75 | 108 | 152H-F108FBD-49 | 153H-F108FBD-49 | |||
| 75 | 100 | 135 | 152H-F135FBD-50 | 153H-F135FBD-50 | |||
| 90 | 125 | 201 | 152H-F201FBD-51 | 153H-F201FBD-51 | |||
| 110 | 150 | 201 | 152H-F201FBD-52 | 153H-F201FBD-52 | |||
| 132 | 200 | 251 | 152H-F251FBD-54 | 153H-F251FBD-54 | |||
| 160 | 250 | 317 | 152H-F317FBD-56 | 153H-F317FBD-56 | |||
| 200 | 300 | 361 | 152H-F361FBD-57 | 153H-F361FBD-57 | |||
| 250 | 350 | 480 | 152H-F480FBD-58 | 153H-F480FBD-58 | |||
| 250 | 400 | 480 | ∆ | 152H-F480JBD-59 | 153H-F480FBD-59 | ||
| 355 | 500 | 625 | ∆ | 152H-F625JBD-61 | ∆ | 153H-F625JBD-61 | |
| 450 | 600 | 780 | ∆ | 152H-F780JBD-62 | ∆ | 153H-F780JBD-62 | |
| 500/575 | 0.55 | 0.75 | 5 | 152H-F5FCD-34 | 153H-F5FCD-34 | ||
| 0.75 | 1 | 5 | 152H-F5FCD-35 | 153H-F5FCD-35 | |||
| 1.1 | 1.5 | 5 | 152H-F5FCD-36 | 153H-F5FCD-36 | |||
| 1.5 | 2 | 5 | 152H-F5FCD-37 | 153H-F5FCD-37 | |||
| 2.2 | 3 | 5 | 152H-F5FCD-38 | 153H-F5FCD-38 | |||
| 3.7 | 5 | 25 | 152H-F25FCD-39 | 153H-F25FCD-39 | |||
| 5.5 | 7.5 | 25 | 152H-F25FCD-40 | 153H-F25FCD-40 | |||
| 7.5 | 10 | 25 | 152H-F25FCD-41 | 153H-F25FCD-41 | |||
| 11 | 15 | 25 | 152H-F25FCD-42 | 153H-F25FCD-42 | |||
| 15 | 20 | 43 | 152H-F43FCD-43 | 153H-F43FCD-43 | |||
| 18.5 | 25 | 43 | 152H-F43FCD-44 | 153H-F43FCD-44 | |||
| 22 | 30 | 43 | 152H-F43FCD-45 | 153H-F43FCD-45 | |||
| 22 | 40 | 43 | 152H-F43FCD-46 | 153H-F43FCD-46 | |||
| 37 | 50 | 60 | 152H-F60FCD-47 | 153H-F60FCD-47 | |||
| 45 | 60 | 85 | 152H-F85FCD-48 | 153H-F85FCD-48 | |||
| 55 | 75 | 85 | 152H-F85FCD-49 | 153H-F85FCD-49 | |||
| 75 | 100 | 108 | 152H-F108FCD-50 | 153H-F108FCD-50 | |||
| 90 | 125 | 135 | 152H-F135FCD-51 | 153H-F135FCD-51 | |||
| 110 | 150 | 201 | 152H-F201FCD-52 | 153H-F201FCD-52 | |||
| 132 | 200 | 201 | 152H-F201FCD-54 | 153H-F201FCD-54 | |||
| 160 | 250 | 251 | 152H-F251FCD-56 | 153H-F251FCD-56 | |||
| 200 | 300 | 317 | 152H-F317FCD-57 | 153H-F317FCD-57 | |||
| 250 | 350 | 361 | 152H-F361FCD-58 | 153H-F361FCD-58 | |||
| 295 | 400 | 480 | ∆ | 152H-F480JCD-59 | 153H-F480FCD-59 | ||
| 315 | 450 | 480 | ∆ | 152H-F480JCD-60 | 153H-F480FCD-60 | ||
| 315 | 500 | 480 | ∆ | 152H-F480JCD-61 | 153H-F480FCD-61 | ||
| 450 | 600 | 625 | ∆ | 152H-F625JCD-62 | ∆ | 153H-F625JCD-62 | |
| 560 | 800 | 780 | ∆ | 152H-F780JCD-65 | ∆ | 153H-F780JCD-65 | |
| ⋆ These controllers require a separate 100…240V, 50/60 Hz single-phase control source. To add a control circuit transformer to the enclosure, add the appropriate option code to the catalog string. | |||||||
| The nominal current rating for the combination package may differ from the controller, based on the horsepower. Consult your local Rockwell Automation sales office or Allen-Bradley distributor. | |||||||
| ♣ Provided with Class J or L fuse clips as standard. | |||||||
| ∆ Available in IP54 (Type 12) enclosure only. | |||||||