| Option
|
Description
|
Cat. No. Modification
|
| Pump Control
|
Provides smooth motor acceleration and deceleration, reducing surges caused by the starting and stopping of centrifugal pumps. Starting time is adjustable from 0…30 s, and stopping time is adjustable from 0…120 s.
|
B⋆
|
| Braking Control
|
Provides Smart Motor Braking (SMB), Accu-Stop, and Slow Speed with Braking.
|
D⋆
|
|
|
| Option
|
Description
|
Cat. No. Modification
|
| Push Buttons
|
Start-Stop Push Button
|
-1
|
| Start-Stop Push Button with H-O-A Selector Switch
|
-1F
|
| Soft Stop Push Button
|
1XA
|
| Pump Stop Push Button
|
1XB
|
| Slow Speed Push Button
|
1XC
|
| Brake Push Button
|
1XD
|
| Accu-Stop/Slow Speed Push Button
|
1XE
|
| Selector Switch
|
Hand-Off-Auto Selector Switch
|
-3
|
| SMC-Off-Bypass Selector Switch
|
-3B ∇
|
| Pilot Lights
|
Transformer Pilot Light - Green Power On Indicator
|
-4G
|
| Transformer Pilot Light - Red Run Indicator
|
-4R
|
| Push-to-Test Pilot Light - Red Run Indicator
|
-5R
|
| Control Circuit Transformer
|
Control Circuit Transformer (fused primary and secondary)
|
-6P
|
| Additional 100VA Control Circuit Transformer (fused primary and secondary)
|
-6PX
|
| 1000VA Control Circuit Transformer (fused primary and secondary)
|
-6PK
|
| 1600VA Control Circuit Transformer (fused primary and secondary)
|
-6PL
|
| 2000VA Control Circuit Transformer (fused primary and secondary)
|
-6PM
|
| Protective Modules
|
480V Line Side Protective Module
|
-8L
|
| 600V Line Side Protective Module
|
| 480V Load Side Protective Module
|
-8M
|
| 600V Load Side Protective Module
|
| 480V Both Line and Load Side Protective Modules
|
-8B
|
| 600V Both Line and Load Side Protective Modules
|
| Human Interface Module
|
Door-mounted, Full Numeric (Type 4/12)
|
-HC3
|
| Communication Module
|
RS-485
|
-20S
|
| Remote I/O
|
-20R
|
| DeviceNet
|
-20D
|
| Ethernet/IP
|
-20E
|
| Control Net
|
-20C
|
| ProfiBUS
|
-20P
|
| Disconnect Auxiliary
|
N.O. disconnect auxiliary mounted on operating mechanism
|
-98
|
| N.C. disconnect auxiliary mounted on operating mechanism
|
-99
|
| Circuit Breaker Auxiliary
|
Internal N.O. circuit breaker auxiliary
|
-98X
|
| Internal N.C. circuit breaker auxiliary
|
-99X
|
| Service Entrance Label
|
Service Entrance Label
|
-SEL
|
| Oil Pump Starter
|
Bulletin 509 NEMA Size 1starter and Bulletin 592 solid-state overload
|
-OPS
|
|
|
⋆ Add the designated letter to the end of the cat. no. Example: To add the Pump Control option: Cat. No. 150-F361NBDB or Cat. No. 152H-F361FBDB-57.
Option push buttons are available only when the corresponding option module is selected. Example: Cat. No. 150-F108FBDB-1XB.
∇ Bypass contactor and overload are not included with this option. A -NB or -BP needs to be added to the catalog string to add these devices.
| Option
|
Description
|
Cat. No. Modification
|
| NEMA Bypass Contactor and Overload Relay
|
5…43 A
|
-NB
|
| 60…85 A
|
| 108…135 A
|
| 201…251 A
|
| 317…361 A
|
| 480 A
|
| NEMA Isolation Contactor
|
5…43 A
|
-NI
|
| 60…85 A
|
| 108…135 A
|
| 201…251 A
|
| 317…361 A
|
| 480 A
|
| MCS Bypass Contactor and Overload Relay
|
5…43 A
|
-BP
|
| 60…85 A
|
| 108…135 A
|
| 201…251 A
|
| 317…361 A
|
| 480 A
|
|
|