| Features
|
SMC™ Flex
|
SMC™-3
|
SMC™ Dialog Plus
|
STC™
|
200…690V 1…1250 A
|
200…600V 1…480 A
|
200…600V 1…1000 A
|
100…240V 1Æ, 1…22 A
|
200…600V 3Æ, 1…22 A
|
| Soft Start
|
S
|
S
|
S
|
S
|
S
|
| Kickstart
|
S
|
S
|
S
|
—
|
—
|
| Current Limit
|
S
|
S
|
S
|
—
|
—
|
| Dual Ramp Start
|
S
|
—
|
S
|
—
|
—
|
| Full Voltage
|
S
|
—
|
S
|
—
|
—
|
| Energy Saver
|
—
|
—
|
S
|
—
|
—
|
| Soft Stop
|
S
|
S
|
O
|
—
|
—
|
| Pump Control
|
O
|
—
|
O
|
—
|
—
|
| Preset Slow Speed
|
S
|
—
|
O
|
—
|
—
|
| Linear Acceleration/Deceleration
|
S
|
—
|
—
|
—
|
—
|
| Torque Control
|
—
|
—
|
—
|
—
|
—
|
| SMB™ Smart Motor Braking
|
O
|
—
|
O
|
—
|
—
|
| Accu-Stop™
|
O
|
—
|
O
|
—
|
—
|
| Slow Speed with Braking
|
O
|
—
|
O
|
—
|
—
|
| Integrated Bypass Contactor
|
S
|
S
|
NA♠
|
—
|
—
|
| Integrated Motor Overload Protection
|
S
|
S
|
S
|
—
|
—
|
| Single-phase Operation
|
—
|
—
|
—
|
S
|
—
|
| DPI Communication
|
S
|
—
|
—
|
—
|
—
|
| Metering
|
S
|
—
|
S
|
—
|
—
|
| Real Time Clock
|
—
|
—
|
—
|
—
|
—
|
| Motor Winding Heater Function
|
|
—
|
—
|
—
|
—
|
| Diagnostic Faults and Alarms
|
S
|
—
|
—
|
—
|
—
|
| Motor and Starter
|
—
|
—
|
—
|
—
|
—
|
| Individual Bit Enable of Faults and Alarms
|
—
|
—
|
—
|
—
|
—
|
| Automatic Tuning of Motor Parameters
|
—
|
—
|
—
|
—
|
—
|
| Parameter Configuration/Programming
|
S
|
—
|
S
|
—
|
—
|
| Human Interface Module (HIM)
|
O
|
—
|
—
|
—
|
—
|
| Parameter Configruation Module
|
—
|
—
|
—
|
—
|
—
|
| Configuration Software: Drives Explorer and Drives Executive
|
O
|
—
|
—
|
—
|
—
|
| Digital I/O Expansion Module§ ♣
|
—
|
—
|
—
|
—
|
—
|
| Ground Fault/CT/PTC Module§
|
—
|
—
|
—
|
—
|
—
|
| Network Communications
|
O
|
—
|
—
|
—
|
—
|
| Inside Delta Connection
|
S
|
S
|
—
|
—
|
—
|
Standards Compliance: CE Marked per Low Voltage Directive 73/23/EEC, 93/68/EEC CSA Certified (File No. LR 1234) UL Listed (File No. E96956)
|
S
|
S
|
S
|
S
|
S
|
|
|
S = Standard Feature O = Optional Feature
|
| ⋆ Starter does not include a configuration device as standard.
|
| Option using a Bulletin 1410 motor winding heater.
|
| § With removable terminal block.
|
| ♣ Starter ships with 2 DC inputs and 2 relay outputs as standard.
|
| ♠ The starter is fully solid-state (no integral bypass). An external bypass contactor can be added as an option.
|
| & Note: Information for this product line is available on the Industrial Controls catalog web site: www.ab.com/catalogs.
|
| ∆ Note: Information for this product line is available in publication 150-SG010* or on the Industrial Controls catalog web site: www.ab.com/catalogs.
|