Catalogs > Industrial Controls Catalog > Motor Control, Solid-State > Soft Starters > SMC™ Dialog Plus Smart Motor Controller
SMC™ Dialog Plus Smart Motor Controller
| Introduction | Standards Compliance and Certifications | Modes of Operation | Cat. No. Explanation | Product Selection |
| Options | Accessories | Specifications | Approximate Dimensions |
Open Type Controllers
| Build a Catalog Number |
Up to 460V AC
| Current¬ Rating (A) |
kWT | Hp | 100…240V AC 50/60 Hz Control Cat. No. |
24V AC/DC Control Cat. No. |
||||
| 230V AC 50 Hz |
400V AC 50 Hz |
200V AC 60 Hz |
230V AC 60 Hz |
460V AC 60 Hz |
||||
| 24 | 5.5 | 11 | 1…5 | 1…7.5 | 1…15 | 150-B24NBD | 150-B24NBR | |
| 35 | 10 | 18.5 | 1…10 | 1…10 | 1…25 | 150-B35NBD | 150-B35NBR | |
| 54 | 15 | 22 | 1…15 | 1…20 | 1…40 | 150-B54NBD | 150-B54NBR | |
| 97 | 25 | 45 | 5…30 | 5…30 | 5…75 | 150-B97NBD | § | 150-B97NBR |
| 135 | 37 | 75 | 5…40 | 5…50 | 5…100 | 150-B135NBD | § | 150-B135NBR |
| 180 | 51 | 90 | 5…60 | 5…60 | 5…150 | 150-B180NBD | § | 150-B180NBR |
| 240 | 75 | 132 | 5…75 | 5…75 | 5…200 | 150-B240NBD | § | 150-B240NBR |
| 360 | 110 | 200 | 5…125 | 5…150 | 5…300 | 150-B360NBD | § | 150-B360NBR |
| 500 | 150 | 257 | 5…150 | 5…200 | 5…400 | 150-B500NBD | § | 150-B500NBR |
| 650 | 200 | 355 | 5…200 | 5…250 | 5…500 | 150-B650NBD | § | 150-B650NBR |
| 720 | 220 | 400 | 5…250 | 5…300 | 5…600 | 150-B720NBD | § | 150-B720NBR |
| 850 | 257 | 475 | 10…300 | 10…350 | 10…700 | 150-B850NBD | § | 150-B850NBR |
| 1000 | 315 | 530 | 10…350 | 10…400 | 10…800 | 150-B1000NBD | § | 150-B1000NBR |
| ¬ Controllers rated 97…360 A are not equipped with line and load terminal lugs. See Accessories for terminal lug kits. | ||||||||
| T The minimum rating is: 0.7 kW for devices with current ratings of 54 A or less; 4 kW for devices rated 97…720 A; 7.5 kW for devices rated 850 A and greater. | ||||||||
| Hp ratings at motor terminal voltages for 208, 480, and 600 line volts, respectively. | ||||||||
| § 120V AC control is required for heatsink fan operation. | ||||||||
Up to 575V AC
| Current¬ Rating (A) |
kWT | Hp | 100…240V AC 50/60 Hz Control Cat. No. |
24V AC/DC Control Cat. No. |
||||||
| 230V AC 50 Hz |
400V AC 50 Hz |
500V AC 50 Hz |
200V AC 60 Hz |
230V AC 60 Hz |
460V AC 60 Hz |
575V AC 60 Hz |
||||
| 24 | 5.5 | 11 | 15 | 1…5 | 1…7.5 | 1…15 | 1…20 | 150-B24NCD | 150-B24NCR | |
| 35 | 10 | 18.5 | 22 | 1…10 | 1…10 | 1…25 | 1…30 | 150-B35NCD | 150-B35NCR | |
| 54 | 15 | 22 | 37 | 1…15 | 1…20 | 1…40 | 1…50 | 150-B54NCD | 150-B54NCR | |
| 97 | 25 | 45 | 63 | 5…30 | 5…30 | 5…75 | 5…75 | 150-B97NCD | § | 150-B97NCR |
| 135 | 37 | 75 | 90 | 5…40 | 5…50 | 5…100 | 5…125 | 150-B135NCD | § | 150-B135NCR |
| 180 | 51 | 90 | 132 | 5…60 | 5…60 | 5…150 | 5…150 | 150-B180NCD | § | 150-B180NCR |
| 240 | 75 | 132 | 160 | 5…75 | 5…75 | 5…200 | 5…250 | 150-B240NCD | § | 150-B240NCR |
| 360 | 110 | 200 | 250 | 5…125 | 5…150 | 5…300 | 5…350 | 150-B360NCD | § | 150-B360NCR |
| 500 | 150 | 257 | 355 | 5…150 | 5…200 | 5…400 | 5…500 | 150-B500NCD | § | 150-B500NCR |
| 650 | 200 | 355 | 475 | 5…200 | 5…250 | 5…500 | 5…600 | 150-B650NCD | § | 150-B650NCR |
| 720 | 220 | 400 | 500 | 5…250 | 5…300 | 5…600 | 5…700 | 150-B720NCD | § | 150-B720NCR |
| 850 | 257 | 475 | 600 | 10…300 | 10…350 | 10…700 | 10…800 | 150-B850NCD | § | 150-B850NCR |
| 1000 | 315 | 530 | 710 | 10…350 | 10…400 | 10…800 | 10…1000 | 150-B1000NCD | § | 150-B1000NCR |
| ¬ Controllers rated 97…360 A are not equipped with line and load terminal lugs. See Accessories for terminal lug kits. | ||||||||||
| T The minimum rating is: 0.7 kW for devices with current ratings of 54 A or less; 4 kW for devices rated 97…720 A; 7.5 kW for devices rated 850 A and greater. | ||||||||||
| Hp ratings at motor terminal voltages for 208, 480, and 600 line volts, respectively. | ||||||||||
| § 120V AC control is required for heatsink fan operation. | ||||||||||
Non-Combination Controllers — IP30 (Type 1) Vented Enclosed, IP65 (Type 4) Enclosed, and IP54 (Type 12) Enclosed
| Build a Catalog Number |
Require a separate 100…240V, 50/60 Hz single-phase control source. Line and load terminations are provided as standard. The IP65 (Type 4) Enclosed Non-Combination, and IP54 (Type 12) Enclosed Non-Combination 97…1000 A controllers include a bypass contactor and a Bulletin 825 converter module. Enclosures other than those listed are available; consult your local Rockwell Automation sales office or Allen-Bradley distributor.
208V AC
| Current Rating | Hp | IP30 (Type 1) Vented Enclosed Non-Combination Controllers |
IP65 (Type 4) Enclosed Non-Combination Controllers |
IP54 (Type 12) Enclosed Non-Combination Controllers |
|||
| 200V AC 60 Hz | Cat. No. | Cat. No. | Cat. No. | ||||
| 24 | 1…5 | § | 150-B24AHD | Ø | 150-B24FHD | Ø | 150-B24JHD |
| 35 | 1…10 | § | 150-B35AHD | Ø | 150-B35FHD | Ø | 150-B35JHD |
| 54 | 1…15 | § | 150-B54AHD | Ø | 150-B54FHD | Ø | 150-B54JHD |
| 97 | 5…30 | 150-B97AHD | 150-B97FHD | 150-B97JHD | |||
| 135 | 5…40 | 150-B135AHD | 150-B135FHD | 150-B135JHD | |||
| 180 | 5…60 | 150-B180AHD | 150-B180FHD | 150-B180JHD | |||
| 240 | 5…75 | 150-B240AHD | 150-B240FHD | 150-B240JHD | |||
| 360 | 5…125 | 150-B360AHD | 150-B360FHD | 150-B360JHD | |||
| 500 | 5…150 | 150-B500AHD | 150-B500FHD | 150-B500JHD | |||
| 650 | 5…200 | 150-B650AHD | 150-B650FHD | 150-B650JHD | |||
| 720 | 5…250 | 150-B720AHD | 150-B720FHD | 150-B720JHD | |||
| 850 | 10…300 | 150-B850AHD | 150-B850FHD | 150-B850JHD | |||
| 1000 | 10…350 | 150-B1000AHD | 150-B1000FHD | 150-B1000JHD | |||
| § Includes internal circulating fan rather than enclosure ventilation. | |||||||
| Ø Includes an internal circulating fan instead of a bypass contactor. | |||||||
230V AC
| Current Rating | kWT | Hp | IP30 (Type 1) Vented Enclosed Non-Combination Controllers |
IP65 (Type 4) Enclosed Non-Combination Controllers |
IP54 (Type 12) Enclosed Non-Combination Controllers |
|||
| 230V AC 50 Hz | 230V AC 60 Hz | Cat. No. | Cat. No. | Cat. No. | ||||
| 24 | 5.5 | 1…5 | § | 150-B24AAD | Ø | 150-B24FAD | Ø | 150-B24JAD |
| 35 | 10 | 1…10 | § | 150-B35AAD | Ø | 150-B35FAD | Ø | 150-B35JAD |
| 54 | 15 | 1…15 | § | 150-B54AAD | Ø | 150-B54FAD | Ø | 150-B54JAD |
| 97 | 25 | 5…30 | 150-B97AAD | 150-B97FAD | 150-B97JAD | |||
| 135 | 37 | 5…40 | 150-B135AAD | 150-B135FAD | 150-B135JAD | |||
| 180 | 51 | 5…60 | 150-B180AAD | 150-B180FAD | 150-B180JAD | |||
| 240 | 75 | 5…75 | 150-B240AAD | 150-B240FAD | 150-B240JAD | |||
| 360 | 110 | 5…125 | 150-B360AAD | 150-B360FAD | 150-B360JAD | |||
| 500 | 150 | 5…150 | 150-B500AAD | 150-B500FAD | 150-B500JAD | |||
| 650 | 200 | 5…200 | 150-B650AAD | 150-B650FAD | 150-B650JAD | |||
| 720 | 220 | 5…250 | 150-B720AAD | 150-B720FAD | 150-B720JAD | |||
| 850 | 257 | 10…300 | 150-B850AAD | 150-B850FAD | 150-B850JAD | |||
| 1000 | 315 | 10…350 | 150-B1000AAD | 150-B1000FAD | 150-B1000JAD | |||
| T The minimum rating is 0.7 kW for devices with current ratings of 54 A or less; 4 kW for devices rated 97…720 A; 7.5 kW for devices 850 A and greater. | ||||||||
| § Includes internal circulating fan rather than enclosure ventilation. | ||||||||
| Ø Includes an internal circulating fan instead of a bypass contactor. | ||||||||
460V AC
| Current Rating | kWT | Hp | IP30 (Type 1) Vented Enclosed Non-Combination Controllers |
IP65 (Type 4) Enclosed Non-Combination Controllers |
IP54 (Type 12) Enclosed Non-Combination Controllers |
|||
| 400V AC 50 Hz | 460V AC 60 Hz | Cat. No. | Cat. No. | Cat. No. | ||||
| 24 | 11 | 1…15 | § | 150-B24ABD | Ø | 150-B24FBD | Ø | 150-B24JBD |
| 35 | 18.5 | 1…25 | § | 150-B35ABD | Ø | 150-B35FBD | Ø | 150-B35JBD |
| 54 | 22 | 1…40 | § | 150-B54ABD | Ø | 150-B54FBD | Ø | 150-B54JBD |
| 97 | 45 | 5…75 | 150-B97ABD | 150-B97FBD | 150-B97JBD | |||
| 135 | 75 | 5…100 | 150-B135ABD | 150-B135FBD | 150-B135JBD | |||
| 180 | 90 | 5…150 | 150-B180ABD | 150-B180FBD | 150-B180JBD | |||
| 240 | 132 | 5…200 | 150-B240ABD | 150-B240FBD | 150-B240JBD | |||
| 360 | 200 | 5…300 | 150-B360ABD | 150-B360FBD | 150-B360JBD | |||
| 500 | 257 | 5…400 | 150-B500ABD | 150-B500FBD | 150-B500JBD | |||
| 650 | 355 | 5…500 | 150-B650ABD | 150-B650FBD | 150-B650JBD | |||
| 720 | 400 | 5…600 | 150-B720ABD | 150-B720FBD | 150-B720JBD | |||
| 850 | 475 | 10…700 | 150-B850ABD | 150-B850FBD | 150-B850JBD | |||
| 1000 | 530 | 10…800 | 150-B1000ABD | 150-B1000FBD | 150-B1000JBD | |||
| T The minimum rating is 0.7 kW for devices with current ratings of 54 A or less; 4 kW for devices rated 97…720 A; 7.5 kW for devices 850 A and greater. | ||||||||
| § Includes internal circulating fan rather than enclosure ventilation. | ||||||||
| Ø Includes an internal circulating fan instead of a bypass contactor. | ||||||||
575V AC
| Current Rating (A) |
kWT | Hp | IP30 (Type 1) Vented Enclosed Non-Combination Controllers |
IP65 (Type 4) Enclosed Non-Combination Controllers |
IP54 (Type 12) Enclosed Non-Combination Controllers |
|||
| 500V AC 50 Hz | 575V AC 60 Hz | Cat. No. | Cat. No. | Cat. No. | ||||
| 24 | 15 | 1…20 | § | 150-B24ACD | Ø | 150-B24FCD | Ø | 150-B24JCD |
| 35 | 22 | 1…30 | § | 150-B35ACD | Ø | 150-B35FCD | Ø | 150-B35JCD |
| 54 | 37 | 1…50 | § | 150-B54ACD | Ø | 150-B54FCD | Ø | 150-B54JCD |
| 97 | 63 | 5…75 | 150-B97ACD | 150-B97FCD | 150-B97JCD | |||
| 135 | 90 | 5…125 | 150-B135ACD | 150-B135FCD | 150-B135JCD | |||
| 180 | 132 | 5…150 | 150-B180ACD | 150-B180FCD | 150-B180JCD | |||
| 240 | 160 | 5…250 | 150-B240ACD | 150-B240FCD | 150-B240JCD | |||
| 360 | 250 | 5…350 | 150-B360ACD | 150-B360FCD | 150-B360JCD | |||
| 500 | 355 | 5…500 | 150-B500ACD | 150-B500FCD | 150-B500JCD | |||
| 650 | 475 | 5…600 | 150-B650ACD | 150-B650FCD | 150-B650JCD | |||
| 720 | 500 | 5…700 | 150-B720ACD | 150-B720FCD | 150-B720JCD | |||
| 850 | 600 | 10…800 | 150-B850ACD | 150-B850FCD | 150-B850JCD | |||
| 1000 | 710 | 10…1000 | 150-B1000ACD | 150-B1000FCD | 150-B1000JCD | |||
| T The minimum rating is 0.7 kW for devices with current ratings of 54 A or less; 4 kW for devices rated 97…720 A; 7.5 kW for devices 850 A and greater. | ||||||||
| § Includes internal circulating fan rather than enclosure ventilation. | ||||||||
| Ø Includes an internal circulating fan instead of a bypass contactor. | ||||||||
Combination Controllers — IP30 (Type 1) Vented Enclosed with Fusible Disconnect, IP54 (Type 12) Enclosed with Fusible Disconnect, IP30 (Type 1) Vented Enclosed with Circuit Breaker, IP54 (Type 12) Enclosed with Circuit Breaker
| Build a Catalog Number |
Includes a 120V control transformer and line and load terminations. The IP54 (Type 12) Enclosed Combination with Fusible Disconnect and IP54 (Type 12) Enclosed Combination with Circuit Breaker 97…1000 A controllers include a bypass contactor and a Bulletin 825 converter module. Enclosures other than those listed are available; consult your local Rockwell Automation sales office or Allen-Bradley distributor.
All Bulletin 153 numbers are supplied with thermal magnetic circuit breakers.
208V AC, 60 Hz
| Hp Range |
Controller Current Rating (A)z |
IP30 (Type 1) Vented Enclosed Combination Controllers with Fusible Disconnect |
IP54 (Type 12) Enclosed Combination Controllers with Fusible Disconnect |
IP30 (Type 1) Vented Enclosed Combination Controllers with Circuit Breaker |
IP54 (Type 12) Enclosed Combination Controllers with Circuit Breaker |
||||
| Cat. No. | Cat. No. | Cat. No. | Cat. No. | ||||||
| 1…5 | 24 | § | 152H-B24AHD-39 | ª | 152H-B24JHD-39 | § | 153H-B24AHD-39 | ª | 153H-B24JHD-39 |
| 7-1/2 | 35 | § | 152H-B35AHD-40 | ª | 152H-B35JHD-40 | § | 153H-B35AHD-40 | ª | 153H-B35JHD-40 |
| 10 | 35 | § | 152H-B35AHD-41 | ª | 152H-B35JHD-41 | § | 153H-B35AHD-41 | ª | 153H-B35JHD-41 |
| 15 | 54 | § | 152H-B54AHD-42 | ª | 152H-B54JHD-42 | § | 153H-B54AHD-42 | ª | 153H-B54JHD-42 |
| 20 | 97 | 152H-B97AHD-43 | 152H-B97JHD-43 | 153H-B97AHD-43 | 153H-B97JHD-43 | ||||
| 25 | 97 | 152H-B97AHD-44 | 152H-B97JHD-44 | 153H-B97AHD-44 | 153H-B97JHD-44 | ||||
| 30 | 97 | 152H-B97AHD-45 | 152H-B97JHD-45 | 153H-B97AHD-45 | 153H-B97JHD-45 | ||||
| 40 | 135 | 152H-B135AHD-46 | 152H-B135JHD-46 | 153H-B135AHD-46 | 153H-B135JHD-46 | ||||
| 50 | 180 | 152H-B180AHD-47 | 152H-B180JHD-47 | 153H-B180AHD-47 | 153H-B180JHD-47 | ||||
| 60 | 180 | 152H-B180AHD-48 | 152H-B180JHD-48 | 153H-B180AHD-48 | 153H-B180JHD-48 | ||||
| 75 | 240 | 152H-B240AHD-49 | 152H-B240JHD-49 | 153H-B240AHD-49 | 153H-B240JHD-49 | ||||
| 100 | 360 | 152H-B360AHD-50 | 152H-B360JHD-50 | 153H-B360AHD-50 | 153H-B360JHD-50 | ||||
| 125 | 360 | 152H-B360AHD-51 | 152H-B360JHD-51 | 153H-B360AHD-51 | 153H-B360JHD-51 | ||||
| 150 | 500 | 152H-B500AHD-52 | 152H-B500JHD-52 | 153H-B500AHD-52 | 153H-B500JHD-52 | ||||
| 200 | 650 | 152H-B650AHD-54 | 152H-B650JHD-54 | 153H-B650AHD-54 | 153H-B650JHD-54 | ||||
| 250 | 720 | 152H-B720AHD-56 | 152H-B720JHD-56 | 153H-B720AHD-56 | 153H-B720JHD-56 | ||||
| 300 | 850 | 152H-B850AHD-57 | 152H-B850JHD-57 | 153H-B850AHD-57 | 153H-B850JHD-57 | ||||
| 350 | 1000 | 152H-B1000AHD-58 | 152H-B1000JHD-58 | 153H-B1000AHD-58 | 153H-B1000JHD-58 | ||||
| z The nominal current rating for the combination package may differ from the controller, based on the horsepower. Consult your local Rockwell Automation sales office or Allen-Bradley distributor. | |||||||||
| § Includes internal circulating fan rather than enclosure ventilation. | |||||||||
| ª Supplied without bypass contactor or converter module. | |||||||||
230V AC, 60 Hz
| Hp Range |
Controller Current Rating (A)z |
IP30 (Type 1) Vented Enclosed Combination Controllers with Fusible Disconnect |
IP54 (Type 12) Enclosed Combination Controllers with Fusible Disconnect |
IP30 (Type 1) Vented Enclosed Combination Controllers with Circuit Breaker |
IP54 (Type 12) Enclosed Combination Controllers with Circuit Breaker |
||||
| Cat. No. | Cat. No. | Cat. No. | Cat. No. | ||||||
| 1…7-1/2 | 24 | § | 152H-B24AAD-40 | ª | 152H-B24JAD-40 | § | 153H-B24AAD-40 | ª | 153H-B24JAD-40 |
| 10 | 35 | § | 152H-B35AAD-41 | ª | 152H-B35JAD-41 | § | 153H-B35AAD-41 | ª | 153H-B35JAD-41 |
| 15 | 54 | § | 152H-B54AAD-42 | ª | 152H-B54JAD-42 | § | 153H-B54AAD-42 | ª | 153H-B54JAD-42 |
| 20 | 54 | § | 152H-B54AAD-43 | ª | 152H-B54JAD-43 | § | 153H-B54AAD-43 | ª | 153H-B54JAD-43 |
| 25 | 97 | 152H-B97AAD-44 | 152H-B97JAD-44 | 153H-B97AAD-44 | 153H-B97JAD-44 | ||||
| 30 | 97 | 152H-B97AAD-45 | 152H-B97JAD-45 | 153H-B97AAD-45 | 153H-B97JAD-45 | ||||
| 40 | 135 | 152H-B135AAD-46 | 152H-B135JAD-46 | 153H-B135AAD-46 | 153H-B135JAD-46 | ||||
| 50 | 135 | 152H-B135AAD-47 | 152H-B135JAD-47 | 153H-B135AAD-47 | 153H-B135JAD-47 | ||||
| 60 | 180 | 152H-B180AAD-48 | 152H-B180JAD-48 | 153H-B180AAD-48 | 153H-B180JAD-48 | ||||
| 75 | 240 | 152H-B240AAD-49 | 152H-B240JAD-49 | 153H-B240AAD-49 | 153H-B240JAD-49 | ||||
| 100 | 360 | 152H-B360AAD-50 | 152H-B360JAD-50 | 153H-B360AAD-50 | 153H-B360JAD-50 | ||||
| 125 | 360 | 152H-B360AAD-51 | 152H-B360JAD-51 | 153H-B360AAD-51 | 153H-B360JAD-51 | ||||
| 150 | 360 | 152H-B360AAD-52 | 152H-B360JAD-52 | 153H-B360AAD-52 | 153H-B360JAD-52 | ||||
| 200 | 500 | 152H-B500AAD-54 | 152H-B500JAD-54 | 153H-B500AAD-54 | 153H-B500JAD-54 | ||||
| 250 | 650 | 152H-B650AAD-56 | 152H-B650JAD-56 | 153H-B650AAD-56 | 153H-B650JAD-56 | ||||
| 300 | 720 | 152H-B720AAD-57 | 152H-B720JAD-57 | 153H-B720AAD-57 | 153H-B720JAD-57 | ||||
| 350 | 850 | 152H-B850AAD-58 | 152H-B850JAD-58 | 153H-B850AAD-58 | 153H-B850JAD-58 | ||||
| 400 | 1000 | 152H-B1000AAD-59 | 152H-B1000JAD-59 | 153H-B1000AAD-59 | 153H-B1000JAD-59 | ||||
| z The nominal current rating for the combination package may differ from the controller, based on the horsepower. Consult your local Rockwell Automation sales office or Allen-Bradley distributor. | |||||||||
| § Includes internal circulating fan rather than enclosure ventilation. | |||||||||
| ª Supplied without bypass contactor or converter module. | |||||||||
460V AC, 60 Hz
| Hp Range |
Controller Current Rating (A)z |
IP30 (Type 1) Vented Enclosed Combination Controllers with Fusible Disconnect |
IP54 (Type 12) Enclosed Combination Controllers with Fusible Disconnect |
IP30 (Type 1) Vented Enclosed Combination Controllers with Circuit Breaker |
IP54 (Type 12) Enclosed Combination Controllers with Circuit Breaker |
||||
| Cat. No. | Cat. No. | Cat. No. | Cat. No. | ||||||
| 1…15 | 24 | § | 152H-B24ABD-42 | ª | 152H-B24JBD-42 | § | 153H-B24ABD-42 | ª | 153H-B24JBD-42 |
| 20 | 35 | § | 152H-B35ABD-43 | ª | 152H-B35JBD-43 | § | 153H-B35ABD-43 | ª | 153H-B35JBD-43 |
| 25 | 35 | § | 152H-B35ABD-44 | ª | 152H-B35JBD-44 | § | 153H-B35ABD-44 | ª | 153H-B35JBD-44 |
| 30 | 54 | § | 152H-B54ABD-45 | ª | 152H-B54JBD-45 | § | 153H-B54ABD-45 | ª | 153H-B54JBD-45 |
| 40 | 54 | § | 152H-B54ABD-46 | ª | 152H-B54JBD-46 | § | 153H-B54ABD-46 | ª | 153H-B54JBD-46 |
| 50 | 97 | 152H-B97ABD-47 | 152H-B97JBD-47 | 153H-B97ABD-47 | 153H-B97JBD-47 | ||||
| 60 | 97 | 152H-B97ABD-48 | 152H-B97JBD-48 | 153H-B97ABD-48 | 153H-B97JBD-48 | ||||
| 75 | 97 | 152H-B97ABD-49 | 152H-B97JBD-49 | 153H-B97ABD-49 | 153H-B97JBD-49 | ||||
| 100 | 135 | 152H-B135ABD-50 | 152H-B135JBD-50 | 153H-B135ABD-50 | 153H-B135JBD-50 | ||||
| 125 | 180 | 152H-B180ABD-51 | 152H-B180JBD-51 | 153H-B180ABD-51 | 153H-B180JBD-51 | ||||
| 150 | 180 | 152H-B180ABD-52 | 152H-B180JBD-52 | 153H-B180ABD-52 | 153H-B180JBD-52 | ||||
| 200 | 240 | 152H-B240ABD-54 | 152H-B240JBD-54 | 153H-B240ABD-54 | 153H-B240JBD-54 | ||||
| 250 | 360 | 152H-B360ABD-56 | 152H-B360JBD-56 | 153H-B360ABD-56 | 153H-B360JBD-56 | ||||
| 300 | 360 | 152H-B360ABD-57 | 152H-B360JBD-57 | 153H-B360ABD-57 | 153H-B360JBD-57 | ||||
| 350 | 500 | 152H-B500ABD-58 | 152H-B500JBD-58 | 153H-B500ABD-58 | 153H-B500JBD-58 | ||||
| 400 | 500 | 152H-B500ABD-59 | 152H-B500JBD-59 | 153H-B500ABD-59 | 153H-B500JBD-59 | ||||
| 450 | 650 | 152H-B650ABD-60 | 152H-B650JBD-60 | 153H-B650ABD-60 | 153H-B650JBD-60 | ||||
| 500 | 650 | 152H-B650ABD-61 | 152H-B650JBD-61 | 153H-B650ABD-61 | 153H-B650JBD-61 | ||||
| 600 | 720 | 152H-B720ABD-62 | 152H-B720JBD-62 | 153H-B720ABD-62 | 153H-B720JBD-62 | ||||
| 700 | 850 | 152H-B850ABD-63 | 152H-B850JBD-63 | 153H-B850ABD-63 | 153H-B850JBD-63 | ||||
| 800 | 1000 | 152H-B1000ABD-65 | 152H-B1000JBD-65 | 153H-B1000ABD-65 | 153H-B1000JBD-65 | ||||
| z The nominal current rating for the combination package may differ from the controller, based on the horsepower. Consult your local Allen-Bradley distributor. | |||||||||
| § Includes internal circulating fan rather than enclosure ventilation. | |||||||||
| ª Supplied without bypass contactor or converter module. | |||||||||
575V AC, 60 Hz
| Hp Range |
Controller Current Rating (A)z |
IP30 (Type 1) Vented Enclosed Combination Controllers with Fusible Disconnect |
IP54 (Type 12) Enclosed Combination Controllers with Fusible Disconnect |
IP30 (Type 1) Vented Enclosed Combination Controllers with Circuit Breaker |
IP54 (Type 12) Enclosed Combination Controllers with Circuit Breaker |
||||
| Cat. No. | Cat. No. | Cat. No. | Cat. No. | ||||||
| 1…20 | 24 | § | 152H-B24ACD-43 | ª | 152H-B24JCD-43 | § | 153H-B24ACD-43 | ª | 153H-B24JCD-43 |
| 25 | 35 | § | 152H-B35ACD-44 | ª | 152H-B35JCD-44 | § | 153H-B35ACD-44 | ª | 153H-B35JCD-44 |
| 30 | 35 | § | 152H-B35ACD-45 | ª | 152H-B35JCD-45 | § | 153H-B35ACD-45 | ª | 153H-B35JCD-45 |
| 40 | 54 | § | 152H-B54ACD-46 | ª | 152H-B54JCD-46 | § | 153H-B54ACD-46 | ª | 153H-B54JCD-46 |
| 50 | 54 | § | 152H-B54ACD-47 | ª | 152H-B54JCD-47 | 153H-B54ACD-47 | ª | 153H-B54JCD-47 | |
| 60 | 97 | 152H-B97ACD-48 | 152H-B97JCD-48 | 153H-B97ACD-48 | 153H-B97JCD-48 | ||||
| 75 | 97 | 152H-B97ACD-49 | 152H-B97JCD-49 | 153H-B97ACD-49 | 153H-B97JCD-49 | ||||
| 100 | 135 | 152H-B135ACD-50 | 152H-B135JCD-50 | 153H-B135ACD-50 | 153H-B135JCD-50 | ||||
| 125 | 135 | 152H-B135ACD-51 | 152H-B135JCD-51 | 153H-B135ACD-51 | 153H-B135JCD-51 | ||||
| 150 | 180 | 152H-B180ACD-52 | 152H-B180JCD-52 | 153H-B180ACD-52 | 153H-B180JCD-52 | ||||
| 200 | 240 | 152H-B240ACD-54 | 152H-B240JCD-54 | 153H-B240ACD-54 | 153H-B240JCD-54 | ||||
| 250 | 240 | 152H-B240ACD-56 | 152H-B240JCD-56 | 153H-B240ACD-56 | 153H-B240JCD-56 | ||||
| 300 | 360 | 152H-B360ACD-57 | 152H-B360JCD-57 | 153H-B360ACD-57 | 153H-B360JCD-57 | ||||
| 350 | 360 | 152H-B360ACD-58 | 152H-B360JCD-58 | 153H-B360ACD-58 | 153H-B360JCD-58 | ||||
| 400 | 500 | 152H-B500ACD-59 | 152H-B500JCD-59 | 153H-B500ACD-59 | 153H-B500JCD-59 | ||||
| 450 | 500 | 152H-B500ACD-60 | 152H-B500JCD-60 | 153H-B500ACD-60 | 153H-B500JCD-60 | ||||
| 500 | 500 | 152H-B500ACD-61 | 152H-B500JCD-61 | 153H-B500ACD-61 | 153H-B500JCD-61 | ||||
| 600 | 650 | 152H-B650ACD-62 | 152H-B650JCD-62 | 153H-B650ACD-62 | 153H-B650JCD-62 | ||||
| 700 | 720 | 152H-B720ACD-63 | 152H-B720JCD-63 | 153H-B720ACD-63 | 153H-B720JCD-63 | ||||
| 800 | 850 | 152H-B850ACD-65 | 152H-B850JCD-65 | 153H-B850ACD-65 | 153H-B850JCD-65 | ||||
| 1000 | 1000 | 152H-B1000ACD-67 | 152H-B1000JCD-67 | 153H-B1000ACD-67 | 153H-B1000JCD-67 | ||||
| z The nominal current rating for the combination package may differ from the controller, based on the horsepower. Consult your local Rockwell Automation sales office or Allen-Bradley distributor. | |||||||||
| § Includes internal circulating fan rather than enclosure ventilation. | |||||||||
| ª Supplied without bypass contactor or converter module. | |||||||||