Current Rating (A)
|
Description
|
Field Modification Cat. No.
|
|
24…54
|
480 V Protective Module (Field Installed)
|
150-N84
|
600 V Protective Module (Field Installed)
|
150-N86
|
| 97…360
|
480 V Protective Module (Field Installed)
|
150-N84L
|
600 V Protective Module (Field Installed)
|
150-N86L
|
|
|
| ¬ The same protective module mounts on the line or load side of the SMC Dialog Plus Controller. For applications requiring both line and load side protection, two protective modules must be ordered.
|
| § Surge protection is provided as standard on 500…1000 A units
|
|
|
Current Rating (A)
|
Wire Size
|
Total No. of Terminal Lugs Possible Each Side
|
Pkg. Quantity
|
Cat. No.
|
| Line Side
|
Load Side
|
|
97…135
|
#6…250 MCM AWG 16 mm2…120 mm2
|
3
|
3
|
3
|
199-LF1
|
| 180…360
|
6
|
6
|
| 500
|
#4…500 MCM AWG 25 mm2…240 mm2
|
6
|
6
|
199-LG1
|
| 650…720
|
9
|
9
|
| 850…1000
|
(2) 1/0…500 MCM AWG 50 mm2…240 mm2
|
6
|
6
|
199-LJ1
|
|
|
| Lugs are supplied with SMC.
|
|
|
Description
|
Field Modification Cat. No.
|
|
IEC line- or load-side terminal covers for 97…135 A devices (includes line and load termination covers)
|
150-NT1
|
IEC line- or load-side terminal covers for 180…360 A devices (includes line and load termination covers)
|
150-NT2
|
|
|
| Description
|
Degree of Protection
|
Cat. No.
|
|
Human Interface Modulev
|
Door Mount Bezel Kit
|
IP30 (Type 1)
|
1201-DMA
|
| Cat. No. 1201-HAP
|
Programmer Only
|
IP30 (Type 1)ª
|
1201-HAP
|
|
Programmer Only
|
IP65 (Type 4/12) with Bezel
|
1201-HJP
|
| Cat. No. 1201-HA1
|
Analog Control Panelz
|
IP30 (Type 1)ª
|
1201-HA1
|
|
Digital Control Panelz
|
IP30 (Type 1)ª
|
1201-HA2
|
| Cat. No. 1201-HA2
|
Digital Control Panelz
|
IP65 (Type 4/12) with Bezel
|
1201-HJ2
|
| Description
|
For Use With
|
Cat. No.
|
|
Communication Cable
|
Male-Male
|
0.3 m
|
Human Interface Module and Communication Modules
|
1202-C03
|
| 1 m
|
1202-C10
|
| 3 m
|
1202-C30
|
Communication Cable Cat. No. 1202-C10
|
9 m
|
1202-C90
|
|
Communication Modulev
|
Single Point Remote I/O
|
Bulletin 150 SMC Dialog Plus
|
1203-GD1
|
| RS-232/RS-422/RS-485/DF1, or DH485 (Series B)
|
1203-GD2
|
| ControlNet
|
1203-CN1
|
| DeviceNet Network
|
1203-GK5
|
Communication Module Cat. No. 1203-GD1
|
Enhanced DeviceNet
|
1203-GU6
|
|
|
Flex I/O SCANport Module§ Flex I/O Terminal Base
|
Bulletin 150 SMC Dialog Plus
|
1203-FB1
|
| Cat. No. 1203-FM1
|
Cat No. 1203-SM1
|
Flex I/O ModuleØ
|
1203-FM1
|
| Communication Option Kits
|
SLC Communication Module
|
1203-SM1
|
|
|
| z Start, Stop, and Jog buttons are the only active controls when used with the SMC Dialog Plus Controller.
|
| ª Requires Type 1 Door Mount Bezel Kit.
|
| v Separately powered 120/240V AC.
|
| § Each Flex I/O SCANport Module requires (1) Cat. No. 1203-FB1 and (1) Cat. No. 1203-FM1.
|
| Ø Requires a Communication Option Cable (Cat. No. 1202-C03/C10/C30/C90) to be functional. These units are not acceptable for NEMA Type 4 door mounting or UL Type 4X outdoor only.
|
|
|
Motor Full Load Current Range [A]
|
Cat. No.
|
|
2.5…20 A
|
825-MCM20
|
| Cat. No. 825-MCM180
|
9…100 A
|
825-MCM180
|
|
64…360 A
|
825-MCM630
|
| Cat. No. 825-MCM630
|
Connection Cable (Replacement) Bul. 825-P to Bul. 825-MCM connection
|
825-MCA
|
|
|
|
|
Description
|
Cat. No.
|
|
Fanning Strip for Bulletin 825 Converter Modules
|
150-NFS
|
| Cat. No. 150-NFS
|
|
M8 connections Set of three 4 x 16 x 102 mm (1/8 x 5/8 x 4-1/64 in.) (125 A max.) Universally applicable Weight: 230 g
|
825-MVM
|
|
|
| ¬ Must be used with fanning strip Cat. No. 150-NFS.
|