Soft Starters

Catalogs > Industrial Controls Catalog > Motor Control, Solid-State > Soft Starters > SMC™ Dialog Plus Smart Motor Controller

SMC™ Dialog Plus Smart Motor Controller

Introduction Standards Compliance and Certifications Modes of Operation Cat. No. Explanation Product Selection
Options Accessories Specifications Approximate Dimensions
Accessories

Protective Modules¬ § 

  Current Rating (A) Description Field Modification
Cat. No.
Click to enlarge - 150-7_23-1 24…54   

480 V Protective Module (Field Installed)  

150-N84
  

600 V Protective Module (Field Installed)  

150-N86
97…360   

480 V Protective Module (Field Installed)  

150-N84L
  

600 V Protective Module (Field Installed)  

150-N86L
  
¬ The same protective module mounts on the line or load side of the SMC Dialog Plus Controller. For applications requiring both line and load side protection, two protective modules must be ordered.
§ Surge protection is provided as standard on 500…1000 A units

Terminal Lug Kits (97…1000 A)

  Current
Rating (A)
Wire Size Total No. of
Terminal Lugs
Possible Each Side
Pkg. Quantity Cat. No.
Line Side Load Side
Click to enlarge - 150-7_23-2 97…135 #6…250 MCM AWG
16 mm2…120 mm2
  
3  
3 3 199-LF1
180…360   
6  
6
500‡  #4…500 MCM AWG
25 mm2…240 mm2
  
6  
6 199-LG1
650…720‡    
9  
9
850…1000‡  (2) 1/0…500 MCM AWG
50 mm2…240 mm2
  
6  
6 199-LJ1
  
‡ Lugs are supplied with SMC.

IEC Terminal Covers

  Description Field Modification
Cat. No.
Click to enlarge - 150-7_23-3   
IEC line- or load-side terminal covers for 97…135 A devices (includes line and load termination covers)  
150-NT1
  
IEC line- or load-side terminal covers for 180…360 A devices (includes line and load termination covers)  
150-NT2
  

Description Degree of Protection Cat. No.
Click to enlarge - 150-7_39-1 Human Interface Modulev  Door Mount Bezel Kit IP30 (Type 1) 1201-DMA
Cat. No. 1201-HAP Programmer Only IP30 (Type 1)ª  1201-HAP
Click to enlarge - 150-7_39-2 Programmer Only IP65 (Type 4/12) with Bezel 1201-HJP
Cat. No. 1201-HA1 Analog Control Panelz  IP30 (Type 1)ª  1201-HA1
Click to enlarge - 150-7_39-3 Digital Control Panelz  IP30 (Type 1)ª  1201-HA2
Cat. No. 1201-HA2 Digital Control Panelz  IP65 (Type 4/12) with Bezel 1201-HJ2
Description For Use With Cat. No.
Click to enlarge - 150-7_39-4 Communication Cable Male-Male 0.3 m Human Interface Module and Communication Modules 1202-C03
1 m 1202-C10
3 m 1202-C30
Communication Cable
Cat. No. 1202-C10
9 m 1202-C90
Click to enlarge - 150-7_39-5 Communication Modulev  Single Point Remote I/O Bulletin 150 SMC Dialog Plus 1203-GD1
RS-232/RS-422/RS-485/DF1, or DH485 (Series B) 1203-GD2
ControlNet 1203-CN1
DeviceNet Network 1203-GK5
Communication Module
Cat. No. 1203-GD1
Enhanced DeviceNet 1203-GU6
Click to enlarge - 150-7_39-6 Click to enlarge - 150-7_39-7 Flex I/O SCANport Module§ 
Flex I/O Terminal Base
Bulletin 150 SMC Dialog Plus 1203-FB1
Cat. No. 1203-FM1 Cat No. 1203-SM1 Flex I/O ModuleØ  1203-FM1
Communication Option Kits SLC Communication Module 1203-SM1
  
z Start, Stop, and Jog buttons are the only active controls when used with the SMC Dialog Plus Controller.
ª Requires Type 1 Door Mount Bezel Kit.
v Separately powered 120/240V AC.
§ Each Flex I/O SCANport Module requires (1) Cat. No. 1203-FB1 and (1) Cat. No. 1203-FM1.
Ø Requires a Communication Option Cable (Cat. No. 1202-C03/C10/C30/C90) to be functional. These units are not acceptable for NEMA Type 4 door mounting or UL Type 4X outdoor only.

Converter Modules¬ 

  Motor Full Load
Current Range [A]
Cat. No.
Click to enlarge - 150-7_40-1 2.5…20 A 825-MCM20
Cat. No. 825-MCM180 9…100 A 825-MCM180
Click to enlarge - 150-7_40-2 64…360 A 825-MCM630
Cat. No. 825-MCM630
Connection Cable (Replacement)
Bul. 825-P to Bul. 825-MCM connection
825-MCA
  

  Description Cat. No.
Click to enlarge - 150-7_40-3 Fanning Strip for Bulletin 825 Converter Modules 150-NFS
Cat. No. 150-NFS
Click to enlarge - 150-7_40-4 M8 connections
Set of three
4 x 16 x 102 mm (1/8 x 5/8 x 4-1/64 in.) (125 A max.)
Universally applicable
Weight: 230 g
825-MVM
  
¬ Must be used with fanning strip Cat. No. 150-NFS.