Soft Starters

Catalogs > Industrial Controls Catalog > Motor Control, Solid-State > Soft Starters > SMC™ Dialog Plus Smart Motor Controller

SMC™ Dialog Plus Smart Motor Controller

Introduction Standards Compliance and Certifications Modes of Operation Cat. No. Explanation Product Selection
Options Accessories Specifications Approximate Dimensions
Accessories

Protective Modules⋆ ∆ 

Click to enlarge - 150-7_23-1 Current Rating [A] Description Field Modification
Cat. No.
24…54 480 V Protective Module (Field Installed) 150-N84
600 V Protective Module (Field Installed) 150-N86
97…360 480 V Protective Module (Field Installed) 150-N84L
600 V Protective Module (Field Installed) 150-N86L
  
⋆ The same protective module mounts on the line or load side of the SMC Dialog Plus Controller. For applications requiring both line and load side protection, two protective modules must be ordered.
∆ Surge protection is provided as standard on 500…1000 A units

Terminal Lug Kits (97…1000 A)

Click to enlarge - 150-7_23-2 Current Rating [A] Wire Size Total No. of
Terminal Lugs
Possible Each Side
Pkg. Quantity Cat. No.
Line Side Load Side
97…135 #6…250 MCM AWG
16 mm2…120 mm2
3 3 3 199-LF1
180…360 6 6
500§  #4…500 MCM AWG
25 mm2…240 mm2
6 6 199-LG1
650…720§  9 9
850…1000§  (2) 1/0…500 MCM AWG
50 mm2…240 mm2
6 6 199-LJ1
  
§ Lugs are supplied with SMC.

IEC Terminal Covers

Click to enlarge - 150-7_23-3 Description Field Modification
Cat. No.
  
IEC line- or load-side terminal covers for 97…135 A devices (includes line and load termination covers)  
150-NT1
  
IEC line- or load-side terminal covers for 180…360 A devices (includes line and load termination covers)  
150-NT2
  

Description Degree of Protection Cat. No.
Click to enlarge - 150-7_39-1 Human Interface Module&  Door Mount Bezel Kit IP30 (Type 1) 1201-DMA
Cat. No. 1201-HAP Programmer Only IP30 (Type 1)∇  1201-HAP
Click to enlarge - 150-7_39-2 Programmer Only IP65 (Type 4/12) with Bezel 1201-HJP
Cat. No. 1201-HA1 Analog Control Panel♠  IP30 (Type 1)∇  1201-HA1
Click to enlarge - 150-7_39-3 Digital Control Panel♠  IP30 (Type 1)∇  1201-HA2
Cat. No. 1201-HA2 Digital Control Panel♠  IP65 (Type 4/12) with Bezel 1201-HJ2
Description For Use With Cat. No.
Click to enlarge - 150-7_39-4 Communication Cable Male-Male 0.3 m Human Interface Module and Communication Modules 1202-C03
1 m 1202-C10
3 m 1202-C30
Communication Cable
Cat. No. 1202-C10
9 m 1202-C90
  Communication Module&  RS-232/RS-422/RS-485/DF1, or DH485 (Series B) Bulletin 150 SMC Dialog Plus 1203-GD2
ControlNet 1203-CN1
Enhanced DeviceNet 1203-GU6
Click to enlarge - 150-7_39-6 Click to enlarge - 150-7_39-7 Flex I/O SCANport Module∆ 
Flex I/O Terminal Base
Bulletin 150 SMC Dialog Plus 1203-FB1
Cat. No. 1203-FM1 Cat No. 1203-SM1 Flex I/O Module♦  1203-FM1
Communication Option Kits SCANport Communication Module 1203-SM1
  
♠ Start, Stop, and Jog buttons are the only active controls when used with the SMC Dialog Plus Controller.
∇ Requires Type 1 Door Mount Bezel Kit.
& Separately powered 120/240V AC.
∆ Each Flex I/O SCANport Module requires (1) Cat. No. 1203-FB1 and (1) Cat. No. 1203-FM1.
♦ Requires a Communication Option Cable (Cat. No. 1202-C03/C10/C30/C90) to be functional. These units are not acceptable for NEMA Type 4 door mounting or UL Type 4X outdoor only.

Converter Modules⋆ 

  Motor Full Load
Current Range [A]
Cat. No.
Click to enlarge - 150-7_40-1 2.5…20 A 825-MCM20
Cat. No. 825-MCM180 20…180 A 825-MCM180
Click to enlarge - 150-7_40-2 160…434 A 825-MCM630
Cat. No. 825-MCM630
Connection Cable (Replacement) Bul. 825-P to Bul. 825-MCM Connection 825-MCA
  

  Description Cat. No.
Click to enlarge - 150-7_40-3 Fanning Strip for Bulletin 825 Converter Modules 150-NFS
Cat. No. 150-NFS
Click to enlarge - 150-7_40-4 M8 connections
Set of three
4 x 16 x 102 mm (1/8 x 5/8 x 4-1/64 in.) (125 A max.)
Universally applicable
Weight: 230 g
825-MVM
  
⋆ Must be used with fanning strip Cat. No. 150-NFS.