Single Loop Temperature/Heater Controllers

Catalogs > Industrial Controls Catalog > Relays, Timers, and Temperature Controllers > Single Loop Temperature/Heater Controllers > Bulletin 900-TC

Bulletin 900-TC

Introduction Certifications Product Selection Accessories
Specifications §  Approximate Dimensions Wiring Terminals — General Guidelines Installation
Product Overview


Bulletin 900 — Temperature/Process Controllers


Product Line Overview

Bulletin 900-TC Temperature Controllers

  Click to enlarge - 900_TC8_4c Click to enlarge - 900_TC16_4c Click to enlarge - 900_TC32_4c
Item Bulletin No.
900-TC8 900-TC16 900-TC32
Dimensions 48 x 96 x 78 mm 48 x 48 x 78 mm 48 x 24 x 100 mm
Sample Rate 250 ms 500 ms
Indication Accuracy Thermocouple: ±0.3% of PV; RTD: ±0.2% of PV; Analog: ±0.2% of F.S. ±0.5% PV +1 digit max.
Heating/Cooling Control Mode Yes Yes Yes
Control Method ON/OFF or 2-PID (auto-tune and self-tune) with time proportioning ON/OFF outputs or Analog Output (900-TC8 & 900-TC16)
Inputs Thermocouple Input and 0...50 mV Yes Yes Yes
Platinum Resistance Temperature Sensor Yes Yes Yes
Analog Input 0...20 mA, 4...20 mA,
1...5V DC, 0...5V DC, 0...10V DC
Non-Contact Temperature Sensor Yes Yes Yes
Control
Output
1 Type
ON/OFF Relay Output (Electro-Mechanical) Yes Yes Yes
ON/OFF Voltage Output for Solid-State Relay Yes Yes Yes
ON/OFF Triac (AC Only) No Yes No
4…20 and 0...20 mA (DC) Analog Yes Yes No
Control
Output
2 Types
ON/OFF Relay No z  No z  No z 
ON/OFF Triac Yes Ø  No No
ON/OFF Voltage SSR Yes Ø  Yes ‡  No
Maximum Number of Alarms None T 
1 Point
2 Points
3 Points Yes Yes No
RS-232C Communications Function Yes §  No No
RS-485 Communications Function Yes §  Yes §  Yes Ø 
Event Input Yes §  Yes§  No
Run/Stop via Keypad or Interrupts Yes Yes Keypad
Multiple SP Selection via Keypad or Interrupts Yes §  Yes §  Keypad
Manual Output Control via Keypad or Interrupts Yes §  Yes §  No
Transfer Output Function (Requires Analog Output) Yes Yes No
Heater Burnout and Heater Short Alarm (Single or 3-Phase) Yesª  Yesª  No
  
T When RS-485 communication is required.
‡ Requires an option unit with an SSR output. Refer to the Options Units table.
§ Requires an option unit. Refer to Option Unit table.
§ Interrupts require an event input option unit. Refer to Option Unit table.
Ø Determined by controller catalog number.
z One of the controller alarm relays can be used as a second control output (e.g., a heating and cooling application).
ª  Requires addition of hardware. One current transformer (900-CT1 or 900-CT2) for single-phase and two current transformers for 3-phase detection. For the 900-TC16, the appropriate option unit must be purchased. Refer to Option Units in the Product Selection tab.