Single Loop Temperature/Heater Controllers

Catalogs > Industrial Controls Catalog > Relays, Timers, and Temperature Controllers > Single Loop Temperature/Heater Controllers > Bulletin 900-TC

Bulletin 900-TC

Introduction Certifications Product Selection Accessories
Specifications ♣  Approximate Dimensions Wiring Terminals — General Guidelines Installation
Product Selection

Build a Catalog Number


Bulletin 900-TC8 Controller Models

Bulletin
No.
DIN Size Sensor Input Type Power
Supply
Voltage
Max No. of
Auxiliary Outputs
Supported ♦ 
Control Output 1 Type Control Output 2 Type Supports Heater Burnout (Open) and Heater Short-Circuit Alarm Controller Cat. No.
900-TC8
⋆ ‡ 
1/8 DIN
48 mm (W) x 96 mm (H) x 78 mm (D)
Thermocouple or RTD 100…
240V AC
3 Relay No 900-TC8RGTZ25
Yes
(1-Phase)
900-TC8RGTH1Z25
Voltage (for driving SSR) No 900-TC8RVGTZ25
Yes
(3-Phase)
900-TC8RGTH3Z25
Voltage (for driving SSR) No 900-TC8VGTZ25
Yes
(1-Phase)
900-TC8VGTH1Z25
TRIAC ∆  No 900-TC8VYGTZ25
Voltage (for driving SSR) No 900-TC8VVGTZ25
Yes
(3-Phase)
900-TC8VGTH3Z25
0...20 or 4...20 mA Analog Output No 900-TC8ACGTZ25
TRIAC ∆  No 900-TC8ACYGTZ25
Voltage (for driving SSR) No 900-TC8ACVGTZ25
Thermocouple or RTD 24V AC/DC 3 Relay No 900-TC8RGTU25
Yes
(1-Phase)
900-TC8RGTH1U25
Voltage (for driving SSR) No 900-TC8VGTU25
Yes
(1-Phase)
900-TC8VGTH1U25
0...20 or 4...20 mA Analog Output No 900-TC8ACGTU25
Analog Current & Voltage 0...20 and 4...20 mA 0...5, 1...5, and 0...10V DC 100…
240V AC
3 Relay Yes
(1-Phase)
900-TC8RABH1Z25
Relay No 900-TC8RABZ25
Voltage (for driving SSR) Yes
(1-Phase)
900-TC8VABH1Z25
Voltage (for driving SSR) No 900-TC8VABZ25
Voltage (for driving SSR) TRIAC ∆  No 900-TC8VYABZ25
0...20 or 4...20 mA Analog Output No 900-TC8ACABZ25
  
⋆ A current transformer (CT) is not provided with the unit.
‡ When the heating and cooling function or the heater burnout alarm is used, one of the relay alarm outputs will be disabled for each function used.
∆ For AC voltage operation only
♦ Typically used for alarms or cooling output in a heat/cool application

Bulletin 900-TC16 Controller Models

Bulletin
No.
DIN Size Sensor Input Type Power
Supply
Voltage
Max No. of
Auxiliary Outputs
Supported ♦ 
Control Output Type ♣  Supports Heater Burnout (Open) and Heater Short-Circuit Alarm Controller Cat. No.
900-TC16
⋆ ‡ 
1/16 DIN
48 mm (W) x 48 mm
(H) x 78 mm (D)
Thermocouple or RTD 100…
240V AC
2 Relay Output Yes§  900-TC16RGTZ25
TRIAC ∆  Yes§  900-TC16YGTZ25
Voltage output (for driving SSR) Yes§  900-TC16VGTZ25
0...20 or 4...20 mA
Analog Output
No 900-TC16ACGTZ25
Thermocouple or RTD 24V AC/DC 2 Relay Output Yes§  900-TC16RGTU25
Voltage output (for driving SSR) Yes§  900-TC16VGTU25
0...20 or 4...20 mA
Analog Output
No 900-TC16ACGTU25
Analog Current & Voltage 0...20 and 4...20 mA 0...5, 1...5, and 0...10V DC 100…
240V AC
2 Relay Yes §  900-TC16RABZ25
TRIAC ∆  Yes §  900-TC16YABZ25
Voltage (for driving SSR) Yes §  900-TC16VABZ25
0...20 or 4...20 mA Analog Output No 900-TC16ACABZ25
24V AC/DC Relay Yes §  900-TC16RABU25
Voltage (for driving SSR) Yes §  900-TC16VABU25
0...20 or 4...20 mA Analog Output No 900-TC16ACABU25
  
⋆ A current transformer (CT) is not provided with the unit.
‡ When the heating and cooling function or the heater burnout alarm is used, one of the relay alarm outputs can be used as the heating or cooling output or heater burnout alarm.
§ To implement the single-phase or three-phase heater burnout and heater short alarm function, an option module must be inserted into the 900-TC16 controller. For a list of 900-TC16 option modules, refer to the Option Units table, Option Units (Bulletins 900-TC8 and 900-TC16 — Only One Option Unit per Controller) The heater burnout and heater short alarm is available by mounting the appropriate option module into any 900-TC16 controller that supports (yes) the heater burnout (open) or heater short-circuit feature.
♣ The Bulletin 900-TC16 can have a second ON/OFF control output (SSR) by adding an option unit to the controller. Refer to Option Units table on Option Units (Bulletins 900-TC8 and 900-TC16 — Only One Option Unit per Controller).
∆ For AC voltage operation only
♦ Typically used for alarms or cooling output in a heat/cool application

Bulletin 900-TC32 Controller Models

Bulletin
No.
DIN Size Power
Supply
Voltage
Max No. of
Alarms
Supported & 
Control Output Type Supports Heater Burnout (Open) and Heater Short-Circuit Alarm Controller Cat. No.with Thermocouple and Platinum RTD Support
900-TC32
♠ ∇ 
1/32 DIN
48 mm (W) x 24 mm (H) x 100 mm (D)
100…
240V AC
1 Relay Output No 900-TC32RGTZ25
Voltage output (for driving SSR) 900-TC32VGTZ25
24V AC/DC 1 Relay Output No 900-TC32RGTU25
Voltage output (for driving SSR) 900-TC32VGTU25
100…
240V AC
RS485 Relay Output No 900-TC32CRGTZ25
Voltage output (for driving SSR) 900-TC32CVGTZ25
24V AC/DC RS485 Relay Output No 900-TC32CRGTU25
Voltage output (for driving SSR) 900-TC32CVGTU25
  
♠ If the heating/cooling function is used, ALM1 will be used for the cooling control output and so the alarm output relay will not be available.
∇ Cat. Nos. with a C designator (e.g., Cat. No. 900-TC32C___) include RS-485 communications, but do not have an alarm (or cooling) output.
& Typically used for alarms or cooling output in a heat/cool application

Option Units (Bulletins 900-TC8 and 900-TC16 — Only One Option Unit per Controller)

The unit provides communications or event input functionality.

Bulletin No. Name Function Cat. No.
900-TC8 Communications Unit RS-232C communications§  900-TC8232(B)& 
RS-485 communications 900-TC8COM(B)& 
Event Input Unit Event input♠  900-TC8EIM
900-TC16 Communications and 1‑Phase Heater Burnout Unit and Heater Short RS-485 communications with single-phase heater burnout (open) and heater short-circuit failure detection∇  900-TC16NCOM(B)# ♣ 
Event Input Unit with 1‑Phase Heater Burnout and Heater Short Event Input with single-phase heater burnout (open) and heater short-circuit failure detection♠ ∇  900-TC16NEIM(B)# 
Event Input Unit Event Input♠  900-TC16NACEIM(B)# 
Communications Unit RS-485 communications 900-TC16NACCOM(B)# ♣ 
Communications and 3‑Phase Heater Burnout and Heater Short Unit RS-485 communications with 3-phase heater burnout (open) and heater short-circuit failure detection 900-TC16NCOMP3(B)# ♣ 
Communications and Second Voltage (SSR) Output Unit RS-485 communications and a second voltage (SSR) output 900-TC16NCOMV2(B)# ♣ 
1-Phase Heater Burnout and second voltage (SSR) output 1-Phase Heater burnout (open) and heater short-circuit failure detection with a second control voltage (SSR) output 900-TC16P1V2(B)# 
  
§ Enables direct RS-232 connection to personal computer using 900Builder™ Lite software. A Cat. No. 900-CP1X cable or equivalent is also required.
♠ Provides two event inputs. Allows selecting up to 4 different pre-configured set points, controller Run/Stop or Auto/Manual mode, from 2 external inputs.
∇ Heater burnout is not available for 0...20 or 4…20 mA analog output style 900-TC16 controllers such as the 900-TC16AC.
& To obtain 57.6 k baud rate, Series B communication units must be used with any 900-TC8 controller catalog number from the Product Selection table on the previous page.
# Series B option units must be used with Series B 900-TC16 controllers. Series A option units cannot be used with Series B controllers and vice versa.
♣ Series B provides 57.6 K baud rate.