Bulletin 900-CONV
| Product Overview |
|
Bulletin 900 — Interface Converter
- Enables RS-232 or USB ¬ (ser. B or later converter) to RS-485 Communications between a Personal Computer (PC) using 900BuilderLite™ (900-TC8/ 900-TC16) or 900Builder™ (900-TC32) Software and up to 31 Bulletin 900-TCx Controllers — ideal for industrial applications
- All signal lines have 1500V AC insulation at the RS-232C (USB: 500 V AC) and RS-485 sides using opto-couples; power supply lines have 1500V AC insulation using a transformer
- Diagnostic LEDs indicate power available and active data transmission
- On-Board wiring and data configuration diagrams simplify startup
- DIN Rail or panel mountable
¬ Use of the USB mode requires the download of free software onto your PC. This software can be found at the
Bulletin 900 Temperature Controller website:
Once at this site, go to "Get Software" (upper right of screen), click on "Virtual Communications Port USB Driver", and follow the instructions.
Standards Compliance and Certifications
Certifications
- cURus Listed (File No. E 113724, Guide No. NRAQ2, NRAQ8)
Product Selection
Standard Models
| Bulletin No. | Size | Power Supply Voltage | Cat. No. |
| 900-CONVT | 30 mm (W) x 80 mm (H) x 78 mm (D) | 100…240V AC | 900-CONVZ25 |
| 24V AC/DC | 900-CONVU25 | ||
| T Converts personal computer RS-232/USB communications to RS-485. Use for interface with a single Bulletin 900-TCx, or multiple (up to 31) controllers with RS-485 communications. | |||
Specifications
| Technical/Control Ratings | ||||
| Communications Method | Master Device (PC) | RS-232C | ||
| Slave Device (900-TCx Controller) | RS-485 (2-wire, half duplex) (selectable) | |||
| Synchronization Method | Start-stop synchronization | |||
| Master Device (PC) | RS-232C Interface | Max. transmission distance | 15 m | |
| Max. number of connectable units | 1 unit | |||
| USB Interface | Max. transmission distance | 5 m or when the total time (hub delay time plus the cable delay time) is less than or equal to 70 ns | ||
| Max. number of connectable slave units | 1 unit | |||
| USB Standard | V1.1 | |||
| Slave Device (900-TCx) RS-485 Interface | Max. transmission distance |
500 m | ||
| Max. number of connectable slave units |
31 units (for multi-drop connection) | |||
| Baud Rate | 1200/2400/4800/9600/19 200/38 400 bps (Default setting: 9600) | |||
| Data Bit Length | 7 or 8 bits (Default setting: 7) | |||
| Stop Bit Length | 1 or 2 bits (Default setting: 2) | |||
| Communications Parity | None, even, odd (Default setting: Even) | |||
| Echoback Selection | Echoback: With/without (Default setting: Without) | |||
| Selection Switch Response Delay | Approx. 30 ms | |||
| General/Environmental Ratings | ||||
| Supply Voltage | 100…240V AC, 50/60 Hz | 24 V AC, 50/60 Hz or 24 V DC | ||
| Operating Voltage Range | 85…110% of rated supply voltage | |||
| Power Consumption | 5 VA max. | 24 V AC: 3 VA max., 24 V DC: 3 W max. | ||
| Ambient Temperature | RS-232C | 10…+55 °C (with no icing) | ||
| USB | 0...+55 °C (with no icing) | |||
| Ambient Humidity | 25…85% (with no condensation) | |||
| Storage Temperature | 20…+65 °C | |||
Specifications, Continued
| General/Environmental Ratings | |||
| Insulation Resistance | 20 MW min. measured at 500V DC between the following: External terminals « casing RS-232C terminals « RS-485 terminals power supply terminals |
||
| Isolation Method | Communications | Phototransistor coupler | |
| Power supply | Isolating transformer | ||
| Dielectric Strength | 1,500 V AC for 1 min. between the external terminal and case, and between the RS-232C RS-485 block power supply terminal | ||
| Noise Immunity | 500 V AC for 1 min. between the RS-232C/USB block and RS-485 block | ||
| Vibration (Max.) | 10…55 Hz, 0.5 mm single amplitude for 10 min. each in X, Y, and Z directions (1 G) | ||
| Shock (Max.) | 98 m/s2 (10 G), 3 times each in X, Y, and Z directions | ||
| Weight | Approx. 150 g | ||
| Enclosure Rating | Front Panel Operation Parts | Conforms to IEC standards, equivalent to IP20 (when terminal cover mounted) ¬ | |
| Terminals | Equivalent to VDE 0106/100 (when terminal cover mounted) ¬ | ||
| Memory Protection | No protective functions (communications data is not protected for power interruptions during communications) | ||
| EMC | Radiated Emission | EN61326 class A | |
| Conducted Emission | EN61326 class A | ||
| Immunity ESD | EN61000-4-2: 4 kV contact discharge (level 2); 8 kV air discharge (level 3) | ||
| Immunity RF-Interference | EN61000-4-3: 10V/m (amplitude modulated, 80 MHz…1 GHz) (level 3) 10V/m (pulse modulated, 900 MHz) |
||
| Immunity Conducted Disturbance | EN61000-4-6: 10V (0.15…80 MHz) (level 3) | ||
| Immunity Burst | EN61000-4-3: 2 kV power-line (level 3); 2 kV I/O signal-line (level 4) | ||
| Conformity to Standards | UL508, CSA C22.2 No. 14-95 Conforms to EN50081-2, EN50082-2, EN61010-1 (IEC 61010-1) Conforms to VDE 0106/part 100 (Finger Protection), when the terminal cover is mounted. |
||
| ¬ When USB communication is used, the cover must be removed | |||
Approximate Dimensions
Approximate dimensions are shown in millimeters unless otherwise indicated. Dimensions are not to be used for manufacturing purposes.
Cat. No. 900-CONVZ25
|
External Connections
RS-485 Connection
|
¬ If RS-485 is selected as the communications method (i.e., pin 9 of the DIP switch is set to OFF), terminals 8 and 9, and terminals 11 and 12 are connected internally.
T A 100…240 V AC, 24 V AC, or 24 V DC (not polarity sensitive) input power supply is required.
| Function | Terminal Number | Name | Signal Direction | Explanation |
| For connecting the operating power supply | 1 and 4 | PWR | — | 100…240V AC or 24 V AC/DC model |
| Connection terminals for RS-232C communications with master device (DIP switch pin 8: OFF) | 3 | SG | — | Connect to signal ground. |
| 5 | SD | Input | Receives data from SD of the master device. | |
| 6 | RD | Output | Sends data to RD of the master device. | |
| Used for RS-485 communications with slave device (DIP switch pin 9: OFF) | 8 | RDA () | Input/ output |
SD and RD for RS-485 (cold side) Terminals 8 and 9 are connected internally when pin 9 of the DIP switch is set to OFF. |
| 9 | SDA () | |||
| 11 | RDB (+) | Input/ output |
SD and RD for RS-485 (hot side) Terminals 11 and 12 are connected internally when pin 9 of the DIP switch is set to OFF. |
|
| 12 | SDB (+) | |||
| Note:Terminals 2 and 10 are not used. | ||||
Connection to an RS-232C Master Device
Set the same communications conditions (baud rate, stop bits, data length, and parity) for the master device, the Interface Converter, and slave devices.
|
With RS-485 communications, connect a terminating resistance (120W, 1/2 W recommended) to both ends of the communications link/network.
§ The Bulletin 900-TCx communications number must be set.
§ A pre-fabricated 3 m RS-232 cable with a 9-pin female D-shell connector on one end and three flying leads at the other is available from Allen-Bradley (Cat. No. 900-CP1X).
Ø RS-485 allows connecting 32 devices.
z Use a commercially available USB cable
ª To use the USB mode requires the download of "free" software into your PC. This software can be found at the
Bulletin 900 Temperature Controller website:
Once at this site, go to "Get Software" (upper right of screen) and click on "Virtual Communications Port USB Driver" and follow the instructions.
Terminal Specifications
Make sure to check the input and output specifications for the signal pins of connected devices before connecting the terminals.
Bulletin 900-CONV Front Display/Operations
|
Caution: Make sure to use the Bulletin 900-CONV with the terminal cover mounted when using in machinery that must conform to EN/IEC standards.