Bulletin 700-SA Tube Base Relay

Product Overview


Click to enlarge - TOC-3-1


Bulletin 700-SA


Standards Compliance and Certifications


Product Selection

Build a Catalog Number


  Input-to-Output Isolation Method Zero Cross Function Status Indicator Output (Load) Max. Continuous Current and Rated Voltage Range Rated Input (Control) Voltage Cat. No.
Click to enlarge - TOC-3-1 Photocoupler Yes Yes 5 A @ 100…240V AC
(47…63 Hz)
5…24V DC 700-SAZY5Z25
Not Applicable 3 A @ 5…110V DC 700-SANY3Z25
  

Accessories

  Description Pkg. Quantity Cat. No.
Click to enlarge - 700SA-32-1 Screw Terminal Tube Base Socket — Panel or DIN Rail Mounting; Guarded Terminal Construction. 8-Pin for use with DPDT Bulletin 700-HA Relays. 10 700-HN100
Click to enlarge - 700-HN108a Specialty Socket
8-pin backwired socket with solder terminals
10 700-HN108
Click to enlarge - 700SA-32-3 Screw Terminal Tube Base Socket — Panel or DIN Rail Mounting; Open Style Construction. 8-Pin for use with DPDT Bulletin 700-HA Relays. No retainer clip required. 10 700-HN125
Click to enlarge - 700SA-32-4 DIN (#3) Symmetrical Rail
35 x 7.5 x 1 m
10 199-DR1
Click to enlarge - 700SA-32-5 Pre-Printed Identification Tags — contains 10 sheets of pre-printed and blank tags. Each sheet contains 13 sets of the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and 117 blank tags. Tags are peel-off with sticky backing for easy placement on relays. 10 700-N40
Blank Identification Tags — contains 10 sheets of blank identification tags for customer specialized printing. Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for easy placement on relays. 10 700-N41
Click to enlarge - 700SA-32-6 Retainer Clip for Sockets with 700-SA AND 700-HB Relays. Secures relay in socket. 10 700-HN158
Click to enlarge - 700_HN205 8-Pin Socket — Can Be Used With or Without Timing Module or Surge Suppressor. Screw Terminal Tube Base Sockets — panel or DIN Rail mounting. Guarded terminal construction. Used with DPDT Bulletin 700-HA Relays. 10 700-HN204
  

Specifications

Control/Input Ratings
Cat. No. Rated Control
Voltage
Max. Operating Control Voltage Range Max. Reverse Control Voltage Impedance Control Voltage Levels
Pick-up Voltage Drop-out Voltage
700-SAZY5Z25 5…24V DC 4…32V DC -32V DC 15 mA max.¬  4V DC max. 1V DC min.
700-SANY3Z25 4…30V DC -30V DC 1.5 kW (+20% -10%)
  

Load/Output Ratings
Cat. No. Rated Load Voltage Maximum Load
Voltage Range
Continuous Load Current (Resistive) [A] Max. Inrush Current‡ 
Min. MaxT 
700-SAZY5Z25 100…240V AC 75…264V AC 0.1 5.0 80 A, @ 50/60 Hz for 1 cycle
700-SANY3Z25 5…110V DC 3…125V DC 0.1 3.0 12 A (10 ms)
  
¬ If the SSR operation is continuous ON/OFF, this value should be reduced by 50%. Refer to "Inrush Current Resistivity§ " graphs below.
T Refer to the following graph "Load Current vs. Ambient Temperature Characteristics" for additional load current details.

Characteristics
Description Cat. No. 700-SAZY5Z25 Cat. No. 700-SANY3Z25
Load Switching Method/Device Triac Transistor
Pick-up Time 1/2 cycle of load power source cycle time§  + 1 ms max. 0.5 ms max.
Drop-out Time 1/2 cycle of load power source cycle time§  + 1 ms max. 2.5 ms max.
Output ON Voltage Drop 1.6V (RMS) max. 1.5V max.
Output Leakage Current 5 mA max. (at 100V AC); 10 mA max. (at 200V AC) 5 mA max. (at 125V DC)
Output VDRM VCEO (V) 600 150
Output di/dt (A/uS) 50
Output dv/dt (V/uS) 500
Output I2t (A2S) 41.6
Output Tj (ÂșC) Max. 125 150
Insulation Resistance 100 MW min. (at 500V DC)
Dielectric Strength 1500V AC, 50/60 Hz for 1 min
Vibration Resistance (Max.) 10…55 Hz, 1.5 mm double amplitude (10 G)
Shock Resistance (max.) 1000 m/s2 (100 G)
Ambient Temperature Operating –30…80 °C (–22…176 °F) with no icing or condensation
Storage –30…100 °C (–22…212 °F) with no icing or condensation
Ambient Humidity 45…85% (no condensation)
Standards Compliance UL 508, CSA C22.2 No. 14, EN 60947-1, -4-3
Certifications cURus Recognized (File No. E96956, Guide NMFT2/NMFT8), CE Marked, VDE Certified
Weight Approx. 70 g
  
¬ With constant current input system. SSR input impedance varies with a change in input (control) voltage.
T Refer to the following graph “Load Current Vs. Ambient Temperature Characteristics” for additional load current details.
‡ If the SSR operation is continuous ON/OFF, this value should be reduced by 50%. Refer to “Inrush Current Resistivity” graph below.
§ 60 Hz full cycle time = 16.6 ms, 50 Hz full cycle time = 20 ms

Load Current vs. Ambient Temperature Characteristics

Inrush Current Resistivity§ 

Click to enlarge - 700SA-34-1


§ Inrush current resistivity is the ability of an SSR to withstand a large surge current for a short period of time. Surges are considered non-repetitive (max. repeatability once every 5 seconds). Keep the inrush current to half the rated value if it occurs repetitively. Exceeding the non-repetitive inrush current will damage the SSR.


Terminal Arrangement (Bottom View)

Click to enlarge - 700SA-35-1


Basic Application Considerations

High Density Mounting of Multiple SSRs

If multiple SSRs are installed side by side be aware that the outer case wall of the SSR serves to dissipate heat. Install the relays so that they are adequately ventilated. If poor ventilation is unavoidable, reduce the load current to half.

Protective Component

When controlling AC inductive loads, connect an inrush/surge absorbing device (varistor) across the SSR load terminals. If the SSR has built-in surge suppression (Bulletins 700-SE and 700-SH) and additional surge suppression is required, connect the varistor across the terminals of the load device. Select a varistor that meets the conditions of the load voltage outlined in the table below.

Load Voltage Varistor Voltage [V] Varistor Surge Resistance
100…120V AC 240…270 1000 A min.
200…240V AC 440…470
380…480V AC 820…1000
  
Note:For additional details applying solid-state relays, refer to pub. 700-AT001_-EN-E, “Solid-State Relay Application Guide”.

For a DC inductive load, a diode should be connected parallel to the load to absorb the counter electromotive force (OFF) of the load.

Click to enlarge - 700SH-57-3


Note:For additional details when using Solid-State Relays, refer to pub. 700-AT001_-EN-E, “Solid-State Relay Application Guide".


Approximate Dimensions

Note:All units in millimeters unless otherwise indicated. To convert millimeters to inches multiply by 0.0394. Dimensions are not intended to be used for manufacturing purposes.


Bul. 700-SA¬ 

Click to enlarge - 700SA-36-1


¬ Bulletin 700-SA is compatible with Cat. Nos. 700-HN100, -108, -125, and -204 (sockets).