| Control/Input Ratings | ||||||
| Cat. No. | Rated Control Voltage |
Max. Operating Control Voltage Range [V DC] | Max. Reverse Control Voltage [V] | Impedance | Control Voltage Levels | |
| Pick-up Voltage | Drop-out Voltage | |||||
| 700-SFZY3Z25 | 5…24V DC | 4…28V DC | 32 | 15 mA max.¬ | 4V DC max. | 1V DC min. |
| 700-SFTY3Z24 | 24V DC | 19.2…28.8V DC | 28.8 | 2 kW ± 20% | 19.2V DC max. | 1V DC min. |
| 700-SFNY3Z25 | 5…24V DC | 4…28V DC | 28.8 | 1.5 kW + 20%/10%T | 4V DC max. | 1V DC min. |
| ¬ With constant current input circuit system, SSR impedance varies with a change in input voltage. | ||||||
| T Input impedance reaches its maximum at the operating voltage. | ||||||
| Load/Output Ratings | |||||
| Cat. No. | Rated Load Voltage | Max. Load Voltage Range | Continuous Load Current (Resistive) [A] | Max. Inrush Current | |
| Min. | Max.§ | ||||
| 700-SFZY3Z25 | 100…240V AC | 75…264V AC | 0.1 | 3 | 45 A @ 50/60 Hz, 1 cycle |
| 700-SFTY3Z24 | 0.1 | 3 | |||
| 700-SFNY3Z25 | 4…48V DC | 3…52.8V DC | 0.1 | 3 | 18 A (10 ms) |
| If the SSR operation is continuous ON/OFF, this value should be reduced by 50%. Refer to the Inrush Current Resistivity graphs on page 50 for more details. | |||||
| § Refer to "Load Current vs. Ambient Temperature Characteristics" on page 50 for additional load current details. | |||||
| Characteristics | |||
| Description | Cat. No. 700-SFZY3Z25 | Cat. No. 700-SFTY3Z24 | Cat. No. 700-SFNY3Z25 |
| Load Switching Method/Device | Triac | Transistor | |
| Pick-up Time | 1/2 cycle of load power source cycle time § + 1 ms max. | 1 ms max. | 0.5 ms max. |
| Drop-out Time | 1/2 cycle of load power source cycle time§ + 1 ms max. | 2 ms max. | |
| Output ON Voltage Drop | 1.6V (RMS) max. | 1.5V max. | |
| Output Leakage Current | 5 mA max. (@ 100 V AC); 10 mA max. (@ 200 V AC) |
2.5 mA max. (@ 100V AC); 5 mA max. (@ 200V AC) |
5 mA max. (@ 50V DC) |
| Output VDRM, VCEO (V) | 600 | 600 | 80 |
| Output di/dt (A/uS) | 50 | 50 | — |
| Output dv/dt (V/uS) | 250 | 250 | — |
| Output I2t (A2S) | 18 | 18 | — |
| Output Tj (°C) Max. | 125 | 125 | 150 |
| Insulation Resistance | 100 MW min. (at 500V DC) | ||
| Dielectric Strength | 1,500V AC, 50/60 Hz for 1 min | ||
| Vibration Resistance (Max.) | 10…55 Hz, 1.5 mm double amplitude (10 G) | ||
| Shock Resistance (Max.) | 1000 m/s2 (100 G) | ||
| Ambient Temperature | Operating: 30…+80 °C (22…+176 °F) with no icing or condensation Storage: 30…+100 °C (22…=212 °F) with no icing or condensation |
||
| Ambient Humidity | 45…85% (no condensation) | ||
| Standards Compliance | UL 508, CSA C22.2 No. 14, EN/IEC 60947-1, -4-3, EN/IEC 60950 | ||
| Certifications | cURus Recognized (File No. E96956, Guide NMFT2/NMFT8), CE Marked, VDE Certified | ||
| Weight | Approx. 50 g | ||
| § 60 Hz full cycle time = 16.6 ms, 50 Hz full cycle time 20 ms | |||
Note:These data are non-repetitive. Keep the inrush current to half the rated value if it occurs repetitively. Inrush current resistivity is the ability of an SSR to withstand a large surge current for a short period of time. Surges are considered non-repetitive (max. repeatability once every 2…5 seconds). Keep the inrush current to half the rated value if it occurs repetitively. Exceeding the non-repetitive inrush current will damage the SSR.
Load Current vs. Ambient Temperature Characteristics
700-SF…
|
Inrush Current Resistivity¬
700-SFZ… 700SFT…
|
Inrush Current Resistivity¬
700-SFN…
|
¬ Inrush current resistivity is the ability of an SSR to withstand a large surge current for a short period of time. Surges are considered non-repetitive (max. repeatability once every 2…5 seconds). Keep the inrush current to half the rated value if it occurs repetitively. Exceeding the non-repetitive inrush current will damage the SSR.