Description
|
Contact Rating
|
Wiring Diagrams
|
Coil Voltage
|
Cat. No. ¬ T
|
| U.S./Canada
|
International
|
|
2PDT 2-Pole 2 Form C Contacts: 10 A = AgNi Contacts
|
10 A C300 R300 Low energy rating; (10V, 10 mA)
|
|
|
12V DC
|
700-HC22Z12
|
| 24V DC
|
700-HC22Z24
|
| 24V AC
|
700-HC22A24
|
| 120V AC
|
700-HC22A1
|
| 700-HN128
|
700-HN103 700-HN104
|
240V AC
|
700-HC22A2
|
4PDT 4-Pole 4 Form C Contacts:
7A = AgNiAu Gold Plated Contacts
|
7 A Low energy rating; (10V, 1 mA)
|
|
|
6V AC
|
700-HC14A06
|
| 12V AC
|
700-HC14A12
|
| 24V AC
|
700-HC14A24
|
| 120V AC
|
700-HC14A1
|
| 240V AC
|
700-HC14A2
|
| 6V DC
|
700-HC14Z06
|
| 12V DC
|
700-HC14Z12
|
| 24V DC
|
700-HC14Z24
|
| 48V DC
|
700-HC14Z48
|
| 110V DC
|
700-HC14Z1
|
4PDT 4-Pole 4 Form C Contacts:
7A = AgNi Silver Contacts
|
7 A C300 R300 Low energy rating; (10V, 10 mA)
|
6V AC
|
700-HC24A06
|
| 12V AC
|
700-HC24A12
|
| 24V AC
|
700-HC24A24
|
| 120V AC
|
700-HC24A1
|
| 240V AC
|
700-HC24A2
|
| 6V DC
|
700-HC24Z06
|
| 12V DC
|
700-HC24Z12
|
| 24V DC
|
700-HC24Z24
|
| 700-HN103
|
48V DC
|
700-HC24Z48
|
| 700-HN128
|
700-HN104
|
110V DC
|
700-HC24Z1
|
|
|
| ¬ LED Option: Add suffix (-4) to the selected Bulletin 700-HC Relay Cat. No. except for the 240V AC units, add (-4L).
|
| T Push-to-Test and LED Option: Add suffix (-3-4) to the selected Bulletin 700-HC Relay Cat. No., except for the 240V AC units, add (-3-4L).
|
|
|
Description
|
Pkg. Qty.
|
Cat. No.
|
|
Diode with LED Surge Suppressor Voltage Range: 6…24V DC used with 700-HN104 socket
|
10
|
700-ADL1
|
Diode with LED Surge Suppressor Voltage Range: 28…60V DC used with 700-HN104 socket
|
10
|
700-ADL2
|
Diode with LED Surge Suppressor Voltage Range: 110…220V DC used with 700-HN104 socket
|
10
|
700-ADL3
|
Varistor with LED Surge Suppressor Voltage Range: 6…24V AC used with 700-HN104 socket
|
10
|
700-AV1R
|
Varistor with LED Surge Suppressor Voltage Range: 110…240V AC used with 700-HN104 socket
|
10
|
700-AV3R
|
RC Surge Suppressor Voltage Range: 6…24V AC/DC used with 700-HN104 socket
|
10
|
700-AR1
|
RC Surge Suppressor Voltage Range: 110…240V AC/DC used with 700-HN104 socket
|
10
|
700-AR2
|
|
Timing Module On-Delay or One-Shot selectable voltage range: 12…24V AC/DC used with Bul. Nos. 700-HN104 socket.
|
|
1
|
700-AT3
|
|
| Cat. No. 700-AT3
|
|
Screw Terminal Socket — Panel or DIN Rail Mounting; Guarded Terminal Construction. Ith = 10 A per pole. 14-blade miniature socket for use with Bulletin 700-SC Relays.
|
10
|
700-HN103
|
| Cat. No. 700-HN103
|
|
Screw Terminal Socket — Panel or DIN Rail Mounting; Guarded Terminal Construction Ith = 10 A per pole. 14-blade miniature socket for use with Bulletin 700-SC relays. This socket has coil and contact separation as well as the ability to plug in optional plug in modules (700-A__ accessories: LED, Surge Suppression, Timing Modules)
|
10
|
700-HN104
|
| Cat. No. 700-HN104
|
|
Screw Terminal Base Socket — Panel or DIN Rail Mounting; Open-Style Construction Ith = 10 A per pole. 14-blade miniature socket for use with Bulletin 700-SC Relays.
|
10
|
700-HN128
|
| Cat. No. 700-HN128
|
|
DIN (#3) Symmetrical Rail 35 x 7.5 x 1 m
|
10
|
199-DR1
|
| Cat. No. 199-DR1
|
|
Retainer Clip for Cat. Nos. 700-HN103, -HN104 and -HN128 Sockets with 700-HC Relays. Secures relay in socket. ¬
|
10
|
700-HN114
|
Plastic Retainer and Ejection Lever For use with the 700-HN104 Sockets for 700-HC relays. Built-in ability to accept 1492 Snap-in Markers
|
10
|
700-HN124
|
| Sample Retainer Clips
|
|
|
| ¬ See Bulletin 700-HC Miniature Square Base Relay, Socket, and Retainer Clip Reference Chart
|
|
|
Description
|
Pkg. Qty.
|
Cat. No.
|
|
Relay Identification Snap-in Markers Snap-in markers fit on top of product covers. Squares slip into molded slot on top of product cover.
|
5
|
1492-MS5X12
|
| 5
|
1492-MS6X9
|
| 5
|
1492-MS6X12
|
| 5
|
1492-MS8X9
|
| 5
|
1492-MS8X12
|
| 100
|
1492-MP-Blank
|
| Snap-in markers
|
|
Pre-Printed Identification Tags — contains 10 sheets of pre-printed and blank tags. Each sheet contains 13 sets of the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and 117 blank tags. Tags are peel-off with sticky backing for easy placement on relays.
|
10
|
700-N40
|
| Markers — Used for terminal identification
|
50
|
700-N41
|
|
|
| Cat. No. 700-HC…
|
| Electrical Ratings
|
| Pilot Duty Rating T
|
NEMA C300, R300
|
Rated Thermal Current (Ith)
|
7 A and 10 A
|
| Rated Insulation Voltage (Ui)
|
250V IEC 300V UL/CSA
|
| Contacts
|
Inductive
|
700-HC_4
|
Hp
|
700-HC22
|
Hp
|
|
|
|
|
|
|
|
|
| 120V AC
|
15 A
|
1.5 A
|
1/8
|
15 A
|
1.5 A
|
1/3
|
| 240V AC
|
7.5 A
|
0.75 A
|
1/3
|
7.5 A
|
0.75 A
|
3/4
|
| General Purpose
|
7 A, 277V AC
|
10 A, 277V AC
|
| Resistive
|
7 A, 30V DC
|
10 A, 24V DC
|
| Min. Low Energy Permissible Load
|
5V, 5 mA (Gold) 10V 1 mA (Silver)
|
| Permissible Coil Voltage Variation
|
Pickup:
|
80…110% of Nominal Voltage at 50 Hz
|
Must Dropout Voltage:
|
20% of Nominal Voltage at AC
|
| 80…110% of Nominal Voltage at 60 Hz
|
10% of Nominal Voltage at DC
|
| 80…110% of Nominal Voltage at DC
|
|
|
|
50 Hz
|
60 Hz
|
| Coil Consumption ±10%
|
AC Coils
|
Inrush
|
2.2 VA
|
1.6 VA
|
| Sealed
|
1.3 VA
|
1.1 VA
|
| DC Coils
|
1.0 W
|
| Max. Allowable Leakage
|
20% of VA (AC)
|
| 10% of W (DC)
|
| Design Specification/Test Requirements
|
| Electrical
|
| Dielectric Withstand Voltage
|
Pole-to-Pole
|
1000V
|
| Contact to Coil
|
3600V
|
| Contact to Frame
|
3600V
|
| Electrical Life (Cycles)
|
100 000 minimum
|
| Mechanical
|
Degree of Protection (Open Type) IEC 529
|
IP 20 (Guarded Terminal Sockets)
|
| Mechanical Life Cycles
|
20 x 106 (AC) 50 x 106 (DC)
|
| Switching Frequency Operations
|
1800/HR
|
| Coil Voltages
|
See Product Selection
|
| Operating Time (ms)
|
Max. Pickup
|
10
|
| Max. Dropout
|
3
|
| Maximum Operating Rate
|
8 cycles/s
|
| Environmental
|
| Temperature
|
Operating
|
30…+55 °C
|
| (22…+131 °F)
|
| Storage
|
55…+85 °C
|
| (67…+185 °F)
|
| Altitude
|
2000 m (6560 ft)
|
| Insulating Material
|
Molded High Dielectric Material
|
| Enclosure
|
Transparent Dust Cover
|
| Contact Material
|
AgNi (700-HC2) AgNi + 5 mm All (700-HC1)
|
| Terminal Markings on Socket
|
In accordance with EN50 0005
|
| Sockets
|
700-HN103, -HN128, -HN104
|
| Certifications
|
cURus Recognized (File No. E14843, Guide NRNT2/NRNT8), cULus Listed when used with Bulletin 700-HN103, -HN104, and -HN128 sockets (File No. E14843, Guide NRNT/NRNT7), CE Marked, LR Certified
|
| Standards
|
UL 508, CSA 22.2 No. 14, EN/IEC 60947-4-1, EN/IEC 60947-5-1
|
|
|
| ¬ See Performance Data.
|
| T NEMA Rating Chart is in publication 700-SG003_-EN-P.
|