Bulletin 700-HK Slim Line Relay

Product Overview


Click to enlarge - 700-HK32A1_4c


Click to enlarge - 700-HK36A1-4_4c


Bulletin 700-HK — “Slim Line” Relay


See Specifications

Build a Catalog Number


Slim Line Relay with Plug-in Quick Connect Terminations

  Description Contact Rating Wiring Diagrams Coil Voltage Cat. No.⋆ ‡ § 
U.S./Canada International
Click to enlarge - 700-HK36A1-4_4c SPDT
1-Pole
1 Form C
AgNi Contacts
16 A Click to enlarge - 700HK-98-4 Click to enlarge - 700HK-98-5 6V AC 700-HK36A06
12V AC 700-HK36A12
24V AC 700-HK36A24
120V AC ♣  700-HK36A1
240V AC ♣  700-HK36A2
6V DC 700-HK36Z06
12V DC 700-HK36Z12
24V DC ♣  700-HK36Z24
48V DC 700-HK36Z48
Bulletin 700-HK SPDT Socket 700-HN121, 700-HN221, 700-HN223 700-HN121, 700-HN221, 700-HN223 110V DC 700-HK36Z1
Click to enlarge - 700-HK32A1_4c DPDT
2-Pole
2 Form C
AgNi Contacts
8 A Click to enlarge - 700HK-98-7 Click to enlarge - 700HK-98-8 6V AC 700-HK32A06
12V AC 700-HK32A12
24V AC 700-HK32A24
120V AC 700-HK32A1
240V AC 700-HK32A2
6V DC 700-HK32Z06
12V DC 700-HK32Z12
24V DC 700-HK32Z24
48V DC 700-HK32Z48
Bulletin 700-HK DPDT Socket 700-HN122, 700-HN222, 700-HN224 700-HN122, 700-HN222, 700-HN224 110V DC 700-HK32Z1
  
⋆ LED Option: Add suffix (-4) to the selected Bulletin 700-HK relay Cat. No. except for the 240V AC units, add (-4L).
‡ For AgNi Contact with Gold Plating: Replace “3” with “X” in Cat. No. For example, if Cat. No. 700-HK36A1 is required with Gold Plating, the new catalog number is 700-HKX6A1.
§ Push-to-Test + Manual Override + LED Option: Add suffix (-3-4) to the selected 700-HK Relay catalog number, except for the 240V AC Units, add (-3-4L).
♣ For high inductive, Tungsten, or Capacitive load applications, replace the "3" with a "M" in the catalog number. Only available in a SPDT configuration and with 24V DC, 120V AC or 240V AC coil voltages.

  Description Pkg. Qty. Cat. No.
Click to enlarge - 700SK-59-1 Screw Terminal Socket — Panel or DIN Rail Mounting 5-blade miniature socket with 10 A rating for use with 1-pole, Bulletin 700-HK relays. Accepts forked lug conductors. Socket includes a retainer clip. 10 700-HN121
Cat. No. 700-HN121
Click to enlarge - 700-HN221_4c Screw Terminal Socket — Panel or DIN Rail Mounting 5-blade miniature socket with 16 A rating for use with 1-pole, Bulletin 700-HK relays. Retainer clips are packaged separately with socket. Guarded terminal construction and compatible with optional plug-in module accessories. 10 700-HN221
Cat. No. 700-HN221
  Spring Clamp Terminal Socket — Panel or DIN Rail Mounting
5-blade miniature socket for use with 1-pole, Bulletin 700-HX relays.
10 700-HN223
 
Click to enlarge - 700HK-99-2 Screw Terminal Socket — Panel or DIN Rail Mounting
8-blade miniature socket with 5 A rating for use with 2-pole, Bulletin 700-HK relays. Accepts forked lug conductors. This socket includes a retainer clip.
10 700-HN122
Cat. No. 700-HN122
Click to enlarge - 700-HN222_4c Screw Terminal Socket — Panel or DIN Rail Mounting
8-blade miniature socket with 8 A rating for use with 2-pole, Bulletin 700-HK relays. Retainer clips are packaged separately with socket. Guarded terminal construction and compatible with optional plug-in module accessories.
10 700-HN222
Cat. No. 700-HN222
  Spring Clamp Terminal Socket — Panel or DIN Rail Mounting
8-blade miniature socket for use with 2-pole Bulletin 700-HX relays.
10 700-HN224
 
Click to enlarge - 700-HN226_r_4c_withrelay Flange Mount Adapter
Used for panel-mounting bulletin 700-HK relays. Order must be for 10 adapters or multiples of 10.
10 700-HN226
Cat. No. 700-HN226
Click to enlarge - 700-HN227_r_4c_withrelay 35 mm Rail Mount Adapter
Mounts bulletin 700-HK relays to a 35 mm rail. Order must be for 10 adapters or multiples of 10.
10 700-HN227
Cat. No. 700-HN227
Click to enlarge - 700-HN229_r_4c Socket Retainer Clip and Ejection Lever
For use with 700-HN22, -HN222, -HN223, and -HN224 sockets. Orders must be for 10 clips or multiples of 10.
10 700-HN229
Cat. No. 700-HN229
  

  Description Pkg. Qty. Cat. No.
Click to enlarge - 700-AV1R (Right)_sm Diode Surge Suppressor
Voltage Range: 6…220V DC used with 700-HN221, 700-HN222 sockets
10 700-ADR
Diode with LED Surge Suppressor
Voltage Range: 6…24V DC used with 700-HN221, 700-HN222 sockets
10 700-ADL1R
Diode with LED Surge Suppressor
Voltage Range: 28…60V DC used with 700-HN221, 700-HN222 sockets
10 700-ADL2R
Diode with LED Surge Suppressor
Voltage Range: 110…220V DC used with 700-HN221, 700-HN222 sockets
10 700-ADL3R
Varistor with LED Surge Suppressor
Voltage Range: 6…24V AC used with 700-HN221, 700-HN222 sockets
10 700-AV1R
Varistor with LED Surge Suppressor
Voltage Range: 110…240V AC used
with 700-HN221, 700-HN222 sockets
10 700-AV3R
RC Surge Suppressor
Voltage Range: 6…24V AC/DC used
with 700-HN221, 700-HN222 sockets
10 700-AR1
RC Surge Suppressor
Voltage Range: 110…240V AC/DC used
with 700-HN221, 700-HN222 sockets
10 700-AR2
Click to enlarge - 700-AT3 (Right)_sm Timing Module
On-Delay or One-Shot selectable voltage range: 12…24V AC/DC used with sockets that accept plug-in accessory modules.
Click to enlarge - 700HC-86-3b 1 700-AT3
Timing Module
On-Delay or One-Shot selectable voltage range: 110…125V AC used with sockets that accept plug-in accessory modules.
700-AT3A1
Timing Module
On-Delay or One-Shot selectable voltage range: 230…240V AC used with sockets that accept plug-in accessory modules.
700-AT3A2
Click to enlarge - 700-HN180_L_4c 8-Way Jumper can be cut to required length. Rated 10 A – 250V. Used with 700-HN221, 700-HN222 sockets. Red 1 700-HN180R
Grey 700-HN180G
Blue 700-HN180B
Cat. No. 700-HN180
Click to enlarge - 700SA-32-4 DIN (#3) symmetrical hat rail
35 x 7.5 x 1 m
10 199-DR1
Cat. No. 199-DR1
  Relay Identification Snap-in Markers
Snap-in markers fit on top of product covers. The following are blank cards.
100 1492-MS6X9
1492-MS6X12
1492-MS8X12
  

Note:Spring clamp sockets are also available. Cat. No. 700-HN223 for Cat. No. 700-HK36 and Cat. No. 700-HN224 for 700-HK32.

Bulletin 700-HK Slim Line Relay, Socket, and Retainer Clip Reference Chart

Relay Type Socket Cat. No. Retainer Clip Cat. No.
700-HK32 700-HN122, 700-HN222, 700-HN224 Provided
700-HK36 700-HN121, 700-HN221, 700-HN223
  

  Cat. No. 700-HK…
Electrical Ratings
Rated Thermal Current ( Ith ) 1-Pole, 1 CO, SPDT — 16 A 2-Pole, 2 CO, DPDT — 8 A
Rated Insulation Voltage (Ui) 250V IEC, 300V UL/CSA
Contacts Inductive V AC 120V AC AC-15, 6.2 A
B300 Pilot Duty, 3 A
A300 (700-HKM_)
1/3 Hp (0.24 kW) 1-phase
120V AC AC-15, 2.9 A
B300 Pilot Duty, 3.0 A
1/4 Hp (0.18 kW), 1-phase
240V AC AC-15, 3.1 A
B300 Pilot Duty, 1.5 A
A300 (700-HKM_)
3/4 Hp (0.55 kW), 1-phase
240V AC AC-15, 1.4 A
B300 Pilot Duty, 1.5 A
1/2 Hp (0.37 kW), 1-phase
230V AC 0.55 kW, 1-phase 230V AC 0.37 kW, 1-phase
Inductive V DC 24V DC DC-13, 5.0 A 24V DC DC-13, 3.0 A
125V DC DC-13, 0.2 A
R300 Pilot Duty, 0.22 A
125V DC DC-13, 0.2 A
R300 Pilot Duty, 0.22 A
250V DC DC-13, 0.1 A
R300 Pilot Duty, 0.11 A
5 A, 250V AC DC-13, 0.1 A
R300 Pilot Duty, 0.11 A
Resisitive 230V AC AC-1, 16 A 230V AC AC-1, 8 A
277V AC 16 A, General Use 277V AC 8 A, General Use
Make, Break & Continuous 30V DC DC-1, 12 A
10 A, Resistive
30V DC DC-1, 6 A
6 A, Resistive
Min. Permissible Contact Ratings 300 mW (5V/60 mA or 60V/5 mA) for AgNi Contacts (700-HK3_)
50 mW (5V/10 mA or 25V/2 mA) for AgNi + Gold Contacts (700-HKX_)
500 mW (100V/5 mA or 5V/100 mA) for AgSnO2 Contacts (700-HKM_)
Permissible Coil Voltage Variation Pickup:
holding Voltage:
Must Dropout Voltage:
80…110% of Nominal Voltage at 50/60 Hz, 73...110% of Nominal Voltage at DC
80% of Nominal V AC at 50/60 Hz, 40% of Nominal V DC
20% of Nominal V AC at 50/60 Hz, 10% Nominal V DC
Power Consumption 1.2V A (V AC Coils), 0.5 W (V DC Coils)
Coil Voltages See Overview/Product Selection
Design Specification/Test Requirements
Dielectric Withstand Voltage Pole to Pole (VRMS) 2000V AC
Contact to Coil (VRMS) 4000V AC
Mechanical
Degree of Protection IP 20 (guarded terminal sockets), RT II — Flux-proof (Relay)
Mechanical Life Operations 10 x 106
Electrical Life Cycles 230V AC, 16 A Resistive: 100 000 min.
277V AC, 16 A Resistive: 30 000 min.
30V DC, 10 A Resisitive: 30 000 min.
B300, R300, Hp (kW): 6000 min.
A300 (700-HKM_): 100,000 min.
230V AC, 8 A Resistive: 100 000 min.
277V AC, 8 A Resistive: 30 000 min.
30V DC, 6 A Resistive: 30 000 min.
B300, R300, Hp (kW): 6000 min.
Switching Frequency Mechanical: 18,000 cycles/hr.
Electrical: 900 cycles/hr.
Operating Time at Nominal
Voltage at 20 °C (ms)
Pickup 15 ms max.
Dropout 5 ms max.
Vibration Operational 10…2000 Hz, 0.76 mm (0.03 in.) 2.5 G
10…2000 Hz, 0.76 mm (0.03 in.) 5.0 G
Non-Operational
Shock Operational 15 G
Non-Operational 50 G
Environmental
Temperature Operating –40…+70 °C
(–40…+158 °F)
Storage –40…+85 °C
(–40…+185 °F)
Altitude 2000 m (6560 ft)
Construction
Insulating Material Molded High Dielectric Material
Enclosure Transparent Dust Cover
Contact Material 700-HK3_: Silver nickel (AgNi); 700-HKX_: Silver Nickel + Gold Plating (AgNi + Au); 700-HKM_: Silver Tin Oxide (AgSnO2)
Terminal Markings on Socket In accordance with EN 50005
Sockets   1-Pole 2-Pole
Screw Terminal 700-HN121 (10 A @ 70 °C)
700-HN221 (16 A @ 50 °C, 12 A @ 70 °C)
700-HN122 (2 x 5 A @ 70 °C)
700-HN222 ( 2 x 8 A @ 70 °C)
Spring Clamp (Available September 2006) 700-HN223 (15 A @ 40 °C with 2 conductors per terminal)
(10 A @ 70 °C with 1 conductor per terminal)
700-HN224 (2 x 8 A@ 70 °C)
Approvals
Certifications CSA Certified, File 75088, UL Recognized, File E3125
Guide NLDX2/NLCX8, cULus Listed with Allen-Bradley sockets (File No. 3125 Guide NLDX/NLDX7), CE Marked
Standards EN61810-1, CSA 22.2 No. 14, UL 508
  

Approximate Dimensions are shown in millimeters (inches). Approximate Dimensions are not intended to be used for manufacturing purposes.

Click to enlarge - 700-HN223-229_dims


Click to enlarge - 700-HK_dims2


Cat. No. A B C D Approx.
Shipping Wt.
199-DR1 35
(1-3/8)
27
(1-1/16)
7.5
(19/64)
1.02
(1/64)
1.85 kg
(4.07 lb) (10/pkg)
199-DR4 35
(1-3/8)
27
(1-1/16)
15
(19/32)
2.3
(3/32)
3.68 kg
(8 lb) (5/pkg)
  

Click to enlarge - 700HK-101-3
Cat. No. 700-HN121
Wire Size: 2 x 2.5 mm2Single Wire – Up to #14 AWGDouble Wire – 2 x 2.5 mm2 (#2–14 AWG… #2–20 AWG)(Either Solid or Stranded)Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)


Click to enlarge - 700HK-101-4
Cat. No. 700-HN122
Wire Size: 2 x 2.5 mm2Single Wire – Up to #14 AWGDouble Wire – 2 x 2.5 mm2 (#2–14 AWG… #2–20 AWG)(Either Solid or Stranded)Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)


⋆ Holes required for mounting [3 mm (1/8 in.) diameter].