Specifications

Ratings
Item  
Pilot Duty Rating NEMA B300
Rated Supply Voltage 24V AC; 12, 24V DC
Pin Type Plug-in
Operating Mode ON-delay, One Shot, Repeat Cycle OFF start, or Repeat Cycle ON start selectable with DIP switch.
Operating Voltage Range 85%…110% of rated supply voltage (12 VDC: 90%…110% of rated supply voltage)¬ 
Power Consumption 24V AC:Relay ON:approx. 0.8 VA (at 24 VAC, 60 Hz)
Relay OFF:0.5 VA (at 24V AC, 60 Hz)
12V DC:Relay ON:approx. 0.4 W (at 12V DC)
Relay OFF:0.1 W (at 12V DC)
24V DC:Relay ON:approx. 0.5 W (at 24V DC)
Relay OFF:0.2 W (at 24V DC)
Control Outputs 5 A at 250V AC, resistive load (cosf = 1)
The minimum applicable load is 10 mA at 5 VDC (P reference value).
Characteristics
Click to enlarge - 700HA-69-1 120V AC 30 A
Make 240V AC 15 A
Click to enlarge - 700HA-69-2 120V AC 3 A
Break 240V AC 1.5 A
Hp at 240V AC 1/6 Hp
Accuracy of Operating Time ±1% FS max. (1 s range: +1%±10 ms max.)
Setting Error ±15%+50 ms FS max.
Reset Time Min. power-opening time: 12, 24V DC: 0.1 s max. (including halfway reset)
24V AC: 0.5 s max. (including halfway reset)
Influence of Voltage ±2% FS max.
Influence of Temperature ±2% FS max.
Insulation Resistance 100 mW min. (at 500V DC)
Dielectric Strength 2000V AC, 50/60 Hz for 1 min (between operating circuit and control output, or contacts of different poles)
1000V AC, 50/60 Hz for 1 min (between non-continuous contacts)
Vibration Resistance Malfunction:10…55 Hz, 0.5 mm single amplitude
Shock Resistance Malfunction:100 m/s2 (approx. 10G)
Ambient Temperature Operating:-10 °C…50 °C (with no icing)
Storage:-25 °C…65 °C (with no icing)
Ambient Humidity Operating:35…85%
Life Expectancy Mechanical:10 000 000 operations min. (under no load at 1800 operations/hr)
Electrical:100 000 operations min. (3 A at 250V AC, resistive load at 1800 operations/hr)
Impulse Withstand Voltage Between power terminals: 1 kV
Noise Immunity ±1.5 kV, square-wave noise by noise simulator (pulse width: 100 ns/1 ms, 1-ns rise)
Static Immunity Destruction:8 kV
Malfunction:4 kV
Enclosure Rating IP20
Weight Approx. 18 g
EMC Emission Enclosure:EN55011 Group 1 class A
Emission AC Mains:EN55011 Group 1 class A
Immunity ESD:EN61000-4-2:4 kV contact discharge (level 2)
8 kV air discharge (level 3)
Immunity RF-interference:ENV50140:10 V/m (amplitude modulated, 80 MHz…1GHz) (level 3)
10 V/m (pulse modulated, 900 MHz)
Immunity Conducted Disturbance:ENV50141:10 V (0.15…80 MHz) (level 3)
Immunity Burst:EN61000-4-4:2 kV power-line (level 3)
2 kV I/O signal-line (level 4)
Standards UL508, CSA C22.2 No. 14, EN/IEC 60947-5-1, EN/IEC 61812-1
Certifications cURus Recognized Component (File No. E14843, Guide NRNTZ/NRNT8), CE Marked, C-Tick Marked
  
¬ When using 700-HNK timer in any place where the ambient temperature is more than 50 °C, supply 90…110% of the rated voltages
(12V DC: 95…11 % of the rated voltage).

Note: t: Set time
        Rt: Reset time


Operating Mode Timing Chart
700-HNK41… 700-HNK42…
Click to enlarge - 700HNK-135-1 Click to enlarge - 700HNK-135-2 Click to enlarge - 700HNK-135-3
Click to enlarge - 700HNK-135-4 Click to enlarge - 700HNK-135-5 Click to enlarge - 700HNK-135-6
Click to enlarge - 700HNK-135-7 Click to enlarge - 700HNK-135-8 Click to enlarge - 700HNK-135-9
Click to enlarge - 700HNK-135-10 Click to enlarge - 700HNK-135-11 Click to enlarge - 700HNK-135-12
  

Wiring Diagrams

Click to enlarge - 700HNK-135-13


Click to enlarge - 700HNK-135-14


A pulse output for a certain period can be obtained with a random external input signal. Use the 700-HNK in interval mode as shown in the following timing chart.

Click to enlarge - 700HNK-136-1


Click to enlarge - 700HNK-136-2


Note: t: Set time
        Rt: Reset time


Mode Terminals
Pulse Operation Power supply between 3 and 8
Short-circuit between 4 and 1
Input signal between 3 and 1
Operating mode; One shot and all other modes Power supply between 1 and 8
  

Time Ranges

Cat. No. Time Range Time Setting Range Setting Factory-Set
700-HNK41AZ12
700-HNK41AZ24
700-HNK41AA24
700-HNK42AZ12
700-HNK42AZ24
700-HNK42AA24
1 s 0.1…1 s Click to enlarge - 700HNK-137-1 Yes
10 s 1…10 s Click to enlarge - 700HNK-137-2 No
1 min 0.1 s…1 min Click to enlarge - 700HNK-137-3 No
10 min 1…10 min Click to enlarge - 700HNK-137-4 No
700-HNK41BZ12
700-HNK41BZ24
700-HNK41BA24
700-HNK42BZ12
700-HNK42BZ24
700-HNK42BA24
1 min 0.1…1 min Click to enlarge - 700HNK-137-1 Yes
10 min 1…10 min Click to enlarge - 700HNK-137-2 No
1 hr 0.1…1 hr Click to enlarge - 700HNK-137-3 No
10 hr 1…10 hr Click to enlarge - 700HNK-137-4 No
  
Note:The left two DIP switch pins are used to select the time ranges.

Click to enlarge - 700HNK-137-9


Operating Modes

Operating Mode Setting Factory-set
On-delay Click to enlarge - 700HNK-137-1 Yes
One Shot Click to enlarge - 700HNK-137-2 No
Repeat Cycle Off-start Click to enlarge - 700HNK-137-3 No
Repeat Cycle On-start Click to enlarge - 700HNK-137-4 No
  
Note:The right two DIP switch pins are used to select the operating modes.