700-HR, -HRS, -HRV
|
700-HRP
|
700-HRC
|
700-HRM
|
700-HRF
|
700-HRY
|
700-HRQ
|
700-HRT (Transistor Outputs)
|
| Electrical Ratings
|
| Pilot Duty Rating
|
NEMA B300
|
—
|
| Thermal Current (Ith)
|
5 A
|
100 mA @ 30V DC max.
|
|
120V AC
|
30 A
|
—
|
| Make
|
240V AC
|
15 A
|
—
|
|
120V AC
|
3 A
|
—
|
| Break
|
240V AC
|
1.5 A
|
—
|
| Hp at 120V
|
1/6 Hp (0.12 kW)
|
1/4 Hp (0.18 kW)
|
1/6 Hp (0.12 kW)
|
1/4 Hp (0.18 kW)
|
1/6 Hp (0.12 kW)
|
—
|
| Hp at 240V
|
1/3 Hp (0.25 kW)
|
—
|
| Resistive Load
|
5 A at 250V AC/30V DC
|
| Inductive Load
|
AC-15 @ 250V AC, 3 A/DC-13 @ 30V DC, 0.5 A
|
| Accuracy of Operating Time
|
±0.2 % FS max. (±0.2 % ±10 ms max. in a range of 1.2 s)
|
| Setting Error
|
±5 % FS ±50 ms (The value is ±5 % FS +100 ms to -0 ms max. when the C or D mode signal of the 700-HRVs are OFF.)
|
| Influence of Voltage
|
±0.2 % FS max. (±0.2 % ±10 ms max. in a range of 1.2 s)
|
| Influence of Temperature
|
±1 % FS max. (±1 % ±10 ms max. in a range of 1.2 s)
|
| Permissible Leakage Current
|
|
| Power Consumption
|
-HR52, -HRS
|
-HRV
|
-HRP, -HRC
|
-HRM
|
-HRF
|
-HRY
|
-HRQ
|
-HRT
|
| 240V AC, Output ON
|
2.1 VA
|
2.5 VA
|
2.0 VA
|
2.1 VA
|
10 VA
|
12 VA
|
0.4 VA
|
—
|
| 240V AC, Output OFF
|
1.3 VA
|
1.8 VA
|
2.0 VA
|
1.3 VA
|
10 VA
|
12 VA
|
0.4 VA
|
—
|
| 24V DC, Output ON
|
0.8 W
|
0.9 W
|
0.9 W
|
0.8 W
|
1.0 W
|
—
|
0.2 W
|
0.3 W
|
| 24V DC, Output OFF
|
0.2 W
|
0.3 W
|
0.9 W
|
0.2 W
|
1.0 W
|
—
|
0.2 W
|
0.2 W
|
| Design Specifications
|
| Dielectric Strength
|
2000V AC (1000V AC for 700-HRT), 50/60 Hz for 1 min (contact to frame) 2000V AC (1000V AC for 700-HRT), 50/60 Hz for 1 min (between control output terminals and operating circuit) 2000V AC, 50/60 Hz for 1 min (pole-to-pole) 1000V AC, 50/60 Hz for 1 min (between contacts not located next to each other) 2000V AC, 50/60 Hz for 1 min (contact to coil)
|
| Mechanical
|
| Vibration Resistance
|
Malfunction: 10…55 Hz with 0.5 mm double amplitude each in three directions for ten minutes each
|
| Shock Resistance
|
Malfunction: 100 m/s2 (10 G)
|
98 m/s2 (10 G)
|
294 m/s2 (10 G)
|
98 m/s2 (10 G)
|
100 m/s2 (10 G)
|
| Environmental
|
| Noise Immunity
|
±1.5 kV for ±600V DC
|
±400V for 12V DC
|
±1kV for 48V DC
|
±1.5 kV for ±600V DC
|
| Static Immunity
|
Malfunction: 8 kV
|
| Ambient Temperature
|
Operating: -10…55 °C (with no icing) Storage: -25…65 °C (with no icing)
|
| Ambient Humidity
|
Operating: 35…85 %
|
| Construction
|
Life Rxpectancy (Min. Operations)
|
Mechanical:20 000 000. (under no load at 1800 operations/h) Electrical: 100 000 (5 A at 250V AC, resistive load at 1800 operations/h)
|
Mech: 107 Electrical: 104
|
| EMC
|
(EMI) EN50081-2 Emission Enclosure:EN55011 Group 1 class A Emission AC Mains: EN55011 Group 1 class A (EMS) EN50082-2 Immunity ESD:EN61000-4-2:4 kV contact discharge (level 2) 8 kV air discharge (level 3) Immunity RF-interference from AM Radio Waves: ENV50140:10 V/m (80 MHz…1 GHz) (level 3) Immunity RF-interference from Pulse-modulated Radio Waves:ENV50204:10 V/m (900 ±5 MHz) (level 3) Immunity Conducted Disturbance:ENV50141:10 V (0.15…80 MHz) (level 3) Immunity Burst:EN61000-4-4:2 kV power-line (level 3) Immunity Surge:EN61000-4-52 kV I/O signal-line (level 4) 1 kV line to line 2 kV line to ground (level 3)
|
| Degree of Protection
|
IP40 (panel surface)
|
| Weight
|
Approx. 90 g
|
| Certifications
|
CSA Certified (File No. 70751), UL Recognized (File No. E14840 Guide No. NKCR2), CE Marked, C-Tick Marked
|
| Standards
|
UL 508, CSA C22.2 No. 14, EN 61812-1, EN 61000-6-2, -6-4
|
|
|