Catalogs >
Industrial Controls Catalog >
Relays, Timers, and Temperature Controllers >
General Purpose Electronic Timers and Counters >
Bulletin 700-HS Timing Relay
Bulletin 700-HS Timing Relay
Product Selection
Single Range Timing Relay with Blade Style Quick Connect/Solder Terminations
|
|
Operating Mode
|
Wiring Diagrams
|
| U.S./Canada
|
International
|
|
On-Delay
|
|
|
| Socket
|
700-HN154 or 700-HN153
|
700-HN153
|
| Off-Delay
|
|
|
Bulletin 700-HS DPDT 2-Pole 2 Form C Contacts
|
Socket
|
700-HN154 or 700-HN153
|
700-HN153
|
|
|
| 700
|
|
HS
|
|
2
|
|
2
|
|
A
|
|
A1
|
|
|
|
a
|
|
b
|
|
c
|
|
d
|
|
e
|
| a
|
| Timer Type
|
| Code
|
Description
|
| HS
|
Square Base Adjustable Timing Relay
|
| b
|
| Mode Type
|
| Code
|
Mode
|
| 1
|
On-Delay
|
| 2
|
Off-Delay
|
| c
|
| Number of Poles
|
| Code
|
Description
|
| 2
|
2PDT
|
| d
|
| Timing Range
|
| Code
|
Adjustable Time — Type HS
|
| A
|
0.1…10 s
|
| B
|
1.0…100 s
|
| C
|
0.1…10 min
|
| D
|
1.0…100 min
|
| E
|
0.1…10 hr
|
| e
|
| Coil Voltage
|
| Code
|
Volts
|
| U12
|
12V AC/DC, 50/60 Hz
|
| U24
|
24V AC/DC, 50/60 Hz
|
| U120
|
120V AC/DC, 50/60 Hz
|
Fixed Timing Relays
|
|
Description
|
|
Bulletin 700-HSF fixed timing relays feature a plug-in square base with blade style terminations. Construction is the same as the Bulletin 700-HS timing relay except that the adjustment knob has been removed to help prevent unwanted tampering. The timing and output specifications are identical to those of the Bulletin 700-HS timing relay. Setting will be ±5% of the time ordered. Socket: Cat. No. 700-HN153 or 700-HN154
|
Bulletin 700-HSF DPDT 2 Pole 2 Form C Contacts
|
|
|
| 700
|
|
HSF
|
|
2
|
|
2
|
|
025
|
|
S
|
|
U24
|
|
|
|
a
|
|
b
|
|
c
|
|
d
|
|
e
|
|
f
|
| a
|
| Timer Type
|
| Code
|
Description
|
| HSF
|
Square Base Fixed Timing Relay
|
| b
|
| Mode Type
|
| Code
|
Mode
|
| 1
|
On-Delay
|
| 2
|
Off-Delay
|
| c
|
| Number of Poles
|
| Code
|
Description
|
| 2
|
2PDT
|
| d
|
| Timing Value ¬
|
| Code
|
Value
|
| 001…999
|
The three digit code represents a numeric value with one decimal place. For example: code 001 is 0.1, code 025 is 2.5, and code 999 is 99.9 The acceptable range for each time unit is listed below: Seconds - 001…999 Minutes - 001…999 Hours - 001…100
|
| e
|
| Timing Units ¬
|
| Code
|
Units
|
| S
|
Seconds
|
| M
|
Minutes
|
| H
|
Hours
|
| f
|
| Coil Voltage
|
| Code
|
Volts
|
| U12
|
12V AC/DC, 50/60 Hz
|
| U24
|
24V AC/DC, 50/60 Hz
|
| U120
|
120V AC/DC, 50/60 Hz
|
¬ Use both the Timing Value and Timing Units tables to properly select the desired fixed time relay.
For example: 700-HSF22025SU24 selects a timer value of 2.5 seconds and 700-HSF22025MU24 selects a timer value of 2.5 minutes.