Bulletin 700-HT Timing Relay
| Product Overview |
|
|
Bulletin 700-HT
- Timing Relay (On-Delay or Off-Delay)
- Rugged Pin Style Socket Mounting
- 10 A, DPDT Contact Ratings
- 0.1 s…30 min Fixed Timing Relay
- 0.1 s…3 min Single Adjustable Timing Relay
- Single or Fixed Timing
Standards Compliance and Certifications
See Specifications.
Product Selection
| Build a Catalog Number |
Single Range Timing Relay with Pin Style Terminations
| 700 | | HT | 2 | 2 | A | A2 | ||||
| a | b | c | d | e |
| a | |
| Timer Type | |
| Code | Description |
| HT | Tube Base Adjustable Timing Relay |
| b | |
| Mode Type | |
| Code | Mode |
| 1 | On-Delay |
| 2 | Off-Delay |
| c | |
| Number of Poles | |
| Code | Description |
| 2 | 2PDT |
| d | |
| Timing Range | |
| Code | Adjustable Time — Type HT |
| A | 0.1…10 s |
| B | 1.0…100 s |
| C | 0.1…10 min |
| D | 1.0…100 min |
| E | 0.1…10 hr |
| e | |
| Coil Voltage | |
| Code | Volts |
| U12 | 12V AC/DC, 50/60 Hz |
| U24 | 24V AC/DC, 50/60 Hz |
| U120 | 120V AC/DC, 50/60 Hz |
| A2 | 240V AC, 50/60 Hz |
Fixed Timing Relays
| 700 | | HTF | 2 | 2 | 025 | S | A2 | |||||
| a | b | c | d | e | f |
| a | |
| Timer Type | |
| Code | Description |
| HTF | Tube Base Fixed Timing Relay |
| b | |
| Mode Type | |
| Code | Mode |
| 1 | On-Delay |
| 2 | Off-Delay |
| c | |
| Number of Poles | |
| Code | Description |
| 2 | 2PDT |
| d | |
| Timing Value ¬ | |
| Code | Value |
| 001…999 | The three digit code represents a numeric value with one decimal place. For example: code 001 is 0.1, code 025 is 2.5, and code 999 is 99.9 The acceptable range for each time unit is listed below: Seconds - 001…999 Minutes - 001…999 Hours - 001…100 |
| e | |
| Timing Units ¬ | |
| Code | Units |
| S | Seconds |
| M | Minutes |
| H | Hours |
| f | |
| Coil Voltage | |
| Code | Volts |
| U12 | 12V AC/DC, 50/60 Hz |
| U24 | 24V AC/DC, 50/60 Hz |
| U120 | 120V AC/DC, 50/60 Hz |
| A2 | 240V AC, 50/60 Hz |
¬ Use both the Timing Value and Timing Units tables to properly select the desired fixed time relay.
For example: 700-HTF22025SU24 selects a timer value of 2.5 seconds and 700-HTF22025MU24 selects a timer value of 2.5 minutes.
Accessories
| Relay Type | Socket Cat. No. | Retainer Clip Cat. No. |
| 700-HT12 | 700-HN100 | 700-HN110 |
| 700-HN125 | Not RequiredT | |
| 700-HT22 | 700-HN101 | 700-HN110 |
| 700-HN126 | Not RequiredT | |
| T Design of these sockets holds the relays securely and does not require retainer clips. | ||
Specifications
| Cat. No. 700-HT… | Cat. No. 700-HTF… | |||||||
| Electrical Ratings | ||||||||
| Pilot Duty RatingT | NEMA B300 | |||||||
| Rated Thermal Current (Ith) | 10 A | |||||||
| Rated Insulation Voltage (Ui) | 250V IEC, 300V UL/CSA | |||||||
| Contacts | Inductive | Make | Break | HP | Make | Break | HP | |
|
|
|
|
|
|||||
| 120V AC | 30 A | 3 A | 1/2 N.O. 1/3 N.C | 30 A | 3 A | 1/3 | ||
| 240V AC | 15 A | 1.5 A | 1/2 N.O. 1/3 N.C | 15 A | 1.5 A | 1/2 | ||
| Resistive 28V DC | 10 A | 10 A | — | 10 A | 10 A | — | ||
| Permissible Coil Voltage Variation | 85…110% of Nominal Voltage at 50 Hz 85…110% of Nominal Voltage at 60 Hz 80…110% of Nominal Voltage at DC |
|||||||
| Power Consumption ±10% | AC | 24V AC | 2 VA | |||||
| 120V AC | 4 VA | |||||||
| 240V AC | 4 VA | |||||||
| DC | 1.3 W | |||||||
| Design Specification/Test Requirements | ||||||||
| Dielectric Withstand Voltage | Pole-to-Pole, same circuit (VRMS) | 1000V AC | ||||||
| Pole-to-Pole, different circuits (VRMS) | 2000V AC | |||||||
| Contact-to-Coil (VRMS) | 2000V AC | |||||||
| Electrical Life Operations | 100,000 minimum | |||||||
| Switching Frequency Operations | 1800/hr | |||||||
| Coil Voltages | See product selection | |||||||
| Mechanical | ||||||||
| Degree of Protection | Open Type (Guarded Terminal Sockets) | |||||||
| Mechanical Life Operations | 10 x 106 | |||||||
| Switching Frequency Operations | 18,000/hr | |||||||
| Timing | Duty Cycle | Continuous | ||||||
| Repeat Accuracy (constant voltage and temperature) |
±2% (Time Delay: 0.1…2 s) ±1% (Time Delay: >2 s) |
|||||||
| Repeat Accuracy (variable voltage and temperature) |
±10% | |||||||
| Fixed Time Setting Accuracy | — | ±5% (Time Delay: 0.1…2 s) ±1% (Time Delay: >2 s) |
||||||
| Scale Tolerance | High End of Range | +5% | — | |||||
| Low End of Range | -50% | — | ||||||
| Reset Time | ON Delay | 100 ms | ||||||
| OFF Delay | 40 ms | |||||||
| Environmental | ||||||||
| Temperature | Operating | 28…+65 °C (50 °C max., 240V AC coil) (18…+149 °F) (122 °F max., 240V AC coil) |
||||||
| Storage | 55…+85 °C (67…+185 °F) |
|||||||
| Altitude | 2000 m (6560 ft) | |||||||
| Construction | ||||||||
| Insulating Material | Molded High Dielectric Material | |||||||
| Enclosure | Impact Resistant Dust Cover | |||||||
| Contact Material | Silver Cadmium Oxide | |||||||
| Terminal Markings on Socket | In accordance with EN50 005 | |||||||
| Sockets | 8- or 11-Pin Socket (On = 8, Off = 11) 700-HN100, -HN125 700-HN101, -HN126 |
|||||||
| Certifications | CSA Certified, File 223833, UL Recognized, File E3125 Guide NLDX 2,UL Listed,whe used with 700-HN100, 700-HN101, 700-HN125, and 700-HN126 Sockets, File No. E3125 Guide NLDX, CE Marked | |||||||
| Standards | EN 61812-1, EN 60947-1,-5-1, CSA 22.2 No. 14, UL 508 | |||||||
| ¬ See Performance Data. | ||||||||
| T NEMA Rating Chart is on page 19 of publication 700-SG003B-EN-P. | ||||||||
Trigger Signal Cat. Nos. 700-HT / -HS
Contact closure provides signal to timer. A low energy signal is generated by the 700-HT / -HS timing relay. For optimum reliability, use contacts designed for low energy switching (10V, 1 mA) (Bul. 800F-X__V, 800T-X__V). No external voltage should be connected to the contact signal.
Timing Diagrams
|
|
Approximate Dimensions
Approximate Dimensions are shown in millimeters (inches). Approximate Dimensions are not intended to be used for manufacturing purposes.
|
|
|
|