Bulletin 700-HXM Preset Counter/Timing Relay
| Product Overview |
Bulletin 700-HXM
- One of the worlds smallest preset digital timers
- Panel-mounted (1/32 DIN cut out)
- Built-in prescaling for counter operation
- Finger protection terminal block (VDE0106/P100)
- NEMA 4/ IP66
- User Manual 700-UM001_-EN-D available at Literature Library
Standards Compliance and Certifications
See Specifications.
Product Selection
| Build a Catalog Number |
| Model | Operating Modes | Counter Modes¬ | Timing Range | Counter Range | Input Voltage | Cat. No. | |
| Input | Output | ||||||
|
A mode: Signal ON-delay B mode: Repeat Cycle D mode: Signal OFF-delay E mode: One Shot F mode: Accumulative Z mode: ON/OFF-duty Adjustable Repeat Cycle |
Increment Decrement Individual Quadrature |
N, F, C, K | 0.000…9999 hr | -999…9999 | 24V DC | 700-HXM66SZ24 |
| Cat. No 700-HXM... | |||||||
| ¬ For counter mode explanation, see Input/Output Modes and Count Values. | |||||||
General Timer Functions
|
Accessories
| Description | Pkg. Quantity | Cat. No. | |
|
Replacement Flush Mounting Adapter (One shipped with each 700-HXM66Z24) |
1 | 700-HN141 |
| Cat. No. 700-HN141 | |||
Specifications
| Characteristics | ||
| Timer Function | Signal start: ±0.03% ±30 ms max. Power-ON start: ±0.03% ±50 ms max. |
|
| Insulation Resistance | 100 mW min. (at 500V DC) | |
| Dielectric Strength | 1500V AC, 50/60 Hz for 1 min between output terminals and non-current-carrying metal parts 510V AC, 50/60 Hz for 1 min between current-carrying terminals (except output terminals) and non-current-carrying metal parts 1500V AC, 50/60 Hz for 1 min between output terminals and current-carrying terminals (except output terminals) 500V AC, 50/60 Hz for 1 min between communications terminals and current-carrying terminals (except output terminals) 1000V AC, 50/60 Hz for 1 min between contacts not located next to each other |
|
| Noise Immunity | Square-wave noise by noise simulator; ±480V (between power terminals), ±600 V (between input terminals) |
|
| Static Immunity | ±8 kV (malfunction), ±15 kV (destruction) | |
| Vibration Resistance | Malfunction | 10…55 Hz with 0.35 mm single amplitude each in three directions for 10 min. |
| Shock Resistance | Malfunction | 100 m/s2 (approx. 10 G), 3 times each in six directions |
| Life Expectancy | Mechanical | 10 million operations |
| Electrical | 100 000 operations min (3 A at 250V AC, resistive load) | |
| Ambient Temperature | Operating | -10…55 °C (with no icing or condensation) |
| Storage | -25…65 °C (with no icing or condensation) | |
| Ambient humidity | 25…85% | |
| EMC | (EMI): Emission Enclosure: EN61326 Class A (EMS): EN61326 Immunity ESD:EN61000-4-2:4 kV contact discharge (level 2) 8 kV air discharge (level 3) Immunity RF-interference:EN61000-4-3:10 V/m (Amplitude-modulated, 80 MHz…1 GHz) (level 3); 10 V/m (Pulse-modulated, 900 MHz ±5 MHz) (level 3) Immunity Conducted Disturbance:EN61000-4-6:3 V (0.15…80 MHz) (level 2) Immunity Burst:EN61000-4-4:2 kV power-line (level 3); 1 kV I/O signal-line (level 4); 1 kV communications-line (level 3) Immunity Surge:EN61000-4-5:1 kV between lines (power and output lines) (level 3); 2 kV between grounds (power and output lines) (level 3) |
|
| Enclosure Ratings | Panel surface: IP66 and NEMA Type 4 (indoors) Rear case: IP20 Terminal block: IP20 |
|
| Weight | Approx. 80 g | |
| Certifications | cURus Recognized Component (File No. E14843, Guide NRNT2/NRNT8), CE Marked, C-Tick Marked | |
| Standards | EN61010-1, EN 61326, UL 508, CSA C22.2 No. 14 | |
Input/Output Modes and Count Values
| Up (Increment) Mode ¬ | Down (Decrement) Mode ¬ | ||
| I n p u t e d g e |
U P |
|
|
| D O W N |
|
|
|
Input/Output Mode Settings
Counter Function
If there is a power failure during output ON, output will turn ON again when the power supply has recovered. For one-shot output, an output will be made again for the duration of the output time setting once the power supply has resumed. Output timing restarted during one-shot outputs is ignored.
| Input Mode | ||||
| Up | Down | Up/Down B.C | ||
| Output mode |
N |
|
|
|
| F |
|
|
|
|
| C |
|
|
|
|
| K |
|
|
|
|
| Note:t-a: Less than the output time t: Output time |
||||
Totalizing Counter Operation
|
- Totalizing counter continues to count the present value, regardless of whether an reset input (by the reset key) has been made to reset the PV.
- When totalizing count value has reset, the PV is reset at the same time.
- The totalizing count range is 0…99999999. If the totalizing count exceeds 99999999, the count returns to 0. If the count drops below 0, it becomes 99999999.
Timer Function
| A Mode: Signal ON-Delay¬ | B Mode: Repeat Cycle¬ |
|
|
| D Mode: Signal OFF-Delay | E Mode: One Shot |
|
|
| F Mode: Accumulative | Z Mode: ON/OFF-Duty Adjustable Repeat Cycle |
|
|
Z Mode
Output quantity can be adjusted by changing the cycle time set in the adjustment level to 1 and by changing the ON duty (%) set value.
The set value shows the ON duty (%) and can be set to a value between 0 and 100 (%). When the cycle time is 0, the output will always be OFF. When the cycle time is not 0 and when ON duty has been set to 0 (%), the output will always be OFF. When ON duty has been set to 100 (%), the output will always be ON.
|
¬ One-shot output or HOLD output can be selected for output:
|
Approximate Dimensions
Approximate Dimensions are shown in millimeters (inches). Approximate Dimensions are not intended to be used for manufacturing purposes.
|
Terminal Arrangement
|