General Purpose Electronic Timers and Counters

Catalogs > Industrial Controls Catalog > Relays, Timers, and Temperature Controllers > General Purpose Electronic Timers and Counters > Bulletin 700-FF DIN Rail Timing Relay

Bulletin 700-FF DIN Rail Timing Relay

Introduction Standards Compliance and Certifications Catalog Number Explanation Accessories Connection Diagrams Specifications
Specifications

Time Characteristics (according to VDE 0435, Part 2021)
Setting Accuracy ±5% of full scale
Repeatability ±0.2% of the setting values
Tolerance Voltage: ±0.001%/%DU
Temperature: ±0.025%/°C
  

Supply
Supply Voltages 24V AC/DC and 110…240V AC, 50/60 Hz
Voltage Tolerance 80%...115% nominal supply voltage
Power Consumption 0.5 W at 24V DC, 9 VA at 240V AC
Time Energized 100%
Reset Time 150 ms
Voltage Interruption £20 ms without reset (supply voltage)
Input Impedance Relay ON: 3K-13K ohms
Relay OFF: 0.7K-4K ohms
Cable Length (Supply Voltage Control) Max. 250 m (490 ft)
  

Pulse Control (B1)
Pulse Duration ³50 ms (AC), ³30 ms (DC)
Input Voltage Supply voltage range
Input Current 1 mA
Max. Leakage Current 400 micro Amps
Cable Length Max. 250 m (800 ft) without parallel load between B1 and A2
Max. 50 m (160 ft) with load (<3 kW) between B1 and A2
  

Outputs
Contact Type Relay as changeover switch
Dielectric Coil to Contact
Withstand Voltage
5000 V
Switching Capacity Voltage: 400V AC
Current Ith (AC-12): 8 A
Power: 2500 VA (AC-12), 500 VA (AC-15)
According to IEC 6047-5-1:
3 A/400V AC (inductive load, AC 14)
3 A/240V AC (inductive load, AC 15)
1 A/24V DC (inductive load, DC 13)
According to UL 508:
1.5 A/240V AC (B300)
3 A/120V AC (B300)
Short-Circuit Resistance 10 A gL
Life Mechanical: 10 million operations
Electrical operations:
4 Mil. at 1 A/250V AC, cos f = 1
0.2 Mil. at 6 A/250V AC, cos f = 1
1.5 Mil. at 1 A/250V AC, cos f = 0.3
0.3 Mil. at 3 A/250V AC, cos f = 0.3
0.5 Mil. at 6 A/24V DC, resistive
2 Mil. at 4 A/24V DC, resistive
2 Mil. at 0.2 A/230V DC, resistive
1 Mil. at 0.4 A/24V DC, L/R = 20 ms
1 Mil. at 0.2 A/110V DC, L/R = 20 ms
1 Mil. at 0.1 A/230V DC, L/R = 20 ms
State Indicator 1 LED, combination signal
  

General Data
Insulation Characteristics 2 kVAC/50 Hz test voltage according to VDE 0435 and 6 kV 1.2/50 ms surge voltage according to IEC 60947-1 between all inputs and outputs
EMC/Interference Immunity Performance of following requirements: Surge capacity of the supply voltage according to IEC 61000-4-5: 4 kV 1.2/50 ms
Burst according to IEC 61000-4-4: 4 kV
ESD discharge according to IEC 61000-4-2: Contact 8 kV, air 8 kV
Immunity according to IEC 61000-4-6: 0.15...80 MHz 10V
Electromagnetic RF field according to IEC 61000-4-3: 80...1000 MHz 10 V/m
EMC/Emission Electromagnetic fields according to EN 55 022: 30 MHz...2 GHz class B
Safe Isolation According to VDE 106, part 101
Climatic Withstand 56 Cycles (24 hr) at 25…40 °C and 95% relative humidity according to IEC 600682-30 and IEC 60068-2-3
Vibration Resistance 4 g in 3three axes at 10…150 Hz, test FC according to IEC 60068-2-6
Shock Resistance 50 g according to IEC 60068-2-27
Protection Class Enclosure:IP 40


Terminal:IP 20 according to IEC 60947-1
Weight 100 g
Ambient Temperature Open: –25…+55 °C
Enclosed: –20…+45 °C
Storage: –40…+85 °C
Terminals Screw terminal M3.5 for Number 2 Posidrive, Philips, and slotted screws. Suitable for power screwdriver. Rated tightening torque 8.8 lb.-in. (0.8 N•m, max. 1.2 N•m).
Dual-chamber system for terminal cross-sections of 1 x 0.5 mm2…2 x 2.5 mm2 (solid) or stranded 2 x 2.5 mm2 (flexible with sleeve), #20…14 AWG. Finger protection according to VDE 0106.
Mounting Front mounting; For snap-on mounting on 35 mm DIN Rail or screw fixing by adapter and two screws (M4 type)
Disposal Synthetic material without dioxin according to EC/EFTA notification
Certifications cULus Listed, File E14840, Guide NKCR/NKCR7, CE Marked
Standards UL 508, CSA 22.2 No. 14, EN/IEC 60947-1, -5-1
  

¬ See Performance Data.