Bulletin 700-HTA Alternating Relay

Introduction Standards Compliance and Certifications Product Selection Accessories Specifications Approximate Dimensions
Specifications

  Cat. No. 700-HTA…
Electrical Ratings
Pilot Duty RatingT  NEMA B300 AC 15
Rated Thermal Current (Ith) 10 A
Rated Insulation Voltage (Ui) 250V IEC, 300V UL/CSA
Contacts Inductive Make Break HP
  Click to enlarge - 700HA-69-1 Click to enlarge - 700HA-69-2  
120V AC 30 A 3 A 1/3
240V AC 15 A 1.5 A 1/2
Resistive 30V DC 10 A 10 A
Permissible Coil Voltage Variation 85…110% of Nominal Voltage at 50 Hz
85…110% of Nominal Voltage at 60 Hz
Power Consumption ±10% AC 24V AC 2 VA
120V AC 4 VA
240V AC 4 VA
Design Specification/Test Requirements
Dielectric Withstand Voltage Pole-to-Pole, same circuit (VRMS) 1000V AC
Pole-to-Pole, different circuits (VRMS) 2000V AC
Contact-to-Coil (VRMS) 2000V AC
Electrical Life Operations 100,000 minimum
Switching Frequency Operations 1800/hr
Coil Voltages See product selection
Mechanical
Degree of Protection Open Type (Guarded Terminal Sockets)
Mechanical Life Operations 10 x 106
Switching Frequency Operations 18,000/hr
Start-up Time (max. time from power application until unit is timing) 0.05 sec
Max. Function Time (max. time power can drop out and unit continues timing) 0.01 sec
Min. Cycle Time 100 ms on release of the control switch
Environmental
Temperature Operating –28…+65 °C (50 °C max., 240V AC coil)
(–18…+149 °F) (122 °F max., 240V AC coil)
Storage –55…+85 °C
(–67…+185 °F)
Altitude 2000 m (6560 ft)
Construction
Insulating Material Molded High Dielectric Material
Enclosure Impact Resistant Dust Cover
Contact Material Silver Tin Oxide
Terminal Markings on Socket In accordance with EN50 005
Sockets 8- or 11-Pin Socket
700-HN100, -HN125
700-HN101, -HN126
Certifications CSA Certified, File 223833, UL Recognized (File E3125 Guide NLDX2/NLDX8), cULus Listed with 700-HN100, 700-HN101, 700-HN125, and 700-HN126 Sockets (File No. E3125 Guide NLDX/NLDX7), CE-Marked (per EU Low Voltage Directive)
Standards EN 61812-1, EN/IEC 60947-1, -5-1, CSA 22.2 No. 14, UL 508
  
¬ Performance Data — See Performance Data, this catalog.
T NEMA Rating Chart is in publication 700-SG003_-EN-P.

Trigger Signal Cat. Nos. 700-HTA

Contact closure provides signal to timer. A low energy signal is generated by the 700-HTA alternating relay. For optimum reliability, use contacts designed for low energy switching (10V, 1 mA) (Example: Bul. 800F-X__V, 800T-X__V). No external voltage should be connected to the contact signal.

Load Diagrams

Click to enlarge - 700-hTA_LoadDiag#1


Click to enlarge - 700-hTA_LoadDiag#2